| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC | L1 | Accepted-AOC Award of contract | |
| 2 | L2₹49.9 L+₹53,615.40 (1.09%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹51.0 L+₹1.6 L (3.25%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹62.7 L+₹13.3 L (27.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹66.8 L+₹17.4 L (35.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
4 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (08) of E/M nature under GE (N) Ahmednagar
2021_MES_492081_1
8584 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹86,000
Yes
14 Jan 2022
3 Dec 2021
6 Jan 2022
3 Dec 2021
4 Jan 2022
22 Dec 2021
60 days
Amount
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 120 sqmm 3.5 core after removing old unserviceable cable etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 70 sqmm 3.5 core after removing old unserviceable cable etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 95 sqmm 3.5 core after removing old unserviceable cable etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 25 sqmm 3.5 core after removing old unserviceable cable etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 16 sqmm 4 core after removing old unserviceable cable etc complete all as specified and directed by Engineer-in-Charge
Supplying, laying & testing in replacement LT UG, XLPE insulated,screened pvc bedded galvanised steel strip or wired armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 4 Core in trenches/drawn through pipe or fixed on wall/poles etc complete all as specified and as directed by Engineer-in-Charge
Supply and laying cable XLPE Insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional are 10 Sq mm 4 core etc complete all as specified and directed by Engineer-in-Charge
M&L for replacement earthing of poles/system with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to GI strip 32x6 mm by means of nuts, bolts and washers and encased in and including 15 dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion etc complete all as specified and directed by Engineer-in-Charge
Supply ,Installing, commissioning and testing in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 1000amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories etc complete all as specified and directed by Engineer-in-Charge (a)MCCB 630 Amp four pole with Breaking Cap 50 KA-01 No (Incoming)
(b) MCCB TPN 400 AmpsTPN with breaking cap 36KA - 04 Nos (For Out Going) (c) MCCB 200 Amps (TP) with breaking capacity 35 KA -04 Nos (For Out Going) (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e ) Ammeter (digital type) with Cts 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes:- 1.All busbar connected with all MCCB (Incoming/outgoing) panel size 1 mtr 2150(H)x2550(W)x750(D)mm The Panel Should be approved by CPRI. 2. The rates quoted shall include for plinth protection around panel 75mm thick and 75 cm vide in PCC 1:3:6 using graded stone aggregate ,earth work and excavation for angle iron frame for foundation / of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 using graded stone aggregade, filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCB shall be hand operated.
Supply ,Installing, commissioning and testing in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories etc complete all as specified and directed by Engineer-in-Charge (a) MCCB 200 Amp four pole with Breaking Cap 35 KA-01 No (Incoming)
(b) MCCB TPN 63 Amps TPN with breaking cap 25KA - 04 Nos (For Out Going) (c) MCCB 100 Amps (TP) with breaking capacity 25 KA -04 Nos (For Out Going) (d) All busbar connected with all MCCB (Incoming/outgoing) panel sizee 2150(H)x2550(W)x750(D)mm (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e) Ammeter (digital type) with Cts 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes:- 1. The Panel Should be approved by CPRI. 2. The rates quoted shall include for plinth protection around panel 75mm thick and 75 cm vide in PCC 1:3:6 using graded stone aggregate ,earth work and excavation for angle iron frame for foundation / of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 using graded stone aggregade, filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCB shall be hand operated
Supply ,Installing, commissioning and testing in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories etc complete all as specified and directed by Engineer-in-Charge (a)MCCB 250 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) MCCB TPN 63 AmpsTPN with breaking cap 25KA - 04 Nos (For Out Going)
(c) MCCB 100 Amps (TP) with breaking capacity 25 KA -02 Nos (For Out Going) (d) All busbar connected with all MCCB (Incoming/outgoing) panel size e 2150(H)x2550(W)x750 (D)mm (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e ) Ammeter (digital type) with Cts 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three)
Notes:- 1. The Panel Should be approved by CPRI. 2. The rates quoted shall include for plinth protection around panel 75mm thick and 75 cm vide in PCC 1:3:6 using graded stone aggregate ,earth work and excavation for angle iron frame for foundation / of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 using graded stone aggregade, filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCB shall be hand operated.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes, laying of cable etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil etc complete all as specified and directed by Engineer-in-Charge
All as per ser item No 15 (here-in-before) but hard/ dense soil
Returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25cm of any soil etc complete all as specified and directed by Engineer-in-Charge
Supply and laying and replacement of PCC covers, class LV type-2 flat size 300 x 180 x 40 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and spread unwahsed dry river sand cushining and covering the under ground cable in trench etc complete all as specified and directed by Engineer-in-Charge
Supply and Lay HDPE pipe 63 mm dia light weight with 0.95 gm/cm2 IS: 4984(1995) PN 6 for laying of LT cables etc complete with all accessores all as specified and directed. Make: Vectus Industries/ Supreme/Infra/Astron Plastic etc complete all as specified and directed by Engineer-in-Charge
Supply and Lay HDPE pipe 75 mm dia for laying of LT cables etc complete with all accessores all as specified and directed by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for the 50 bore pipe etc complete all as specified and directed by Engineer-in-Charge
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for up to 50 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge
Dismantaling old valve chamber & M & L for Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the following internal size as under : (a)100 mm thick hard core, (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggergate) (c) 200 mm thick block masonary graded C-5 built in cement and sand mortar (1:6), (d)15 mm internal and external plaster in cement and sand mortar (1:4), (e) 3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over a coat of red oxide primer on all exposed surface including locking arrangments etc complete all as specified and directed by Engineer-in-Charge
(a) 1500 mm x 1200 mm x 1000 mm
Drilling and tapping cast iron / ductile iron water mains, in position, for branch connections of the internal dia 20 to 50 mm etc complete all as specified and directed by Engineer-in-Charge
M & L for steel tubular poles, swan neck type ,modular or design approved by engr in charge complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Mtrs Long) including taking down existing pole complete etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing of MS clamps of size 25x3 mm with nut, bolt and washers duly painted with two coats of aluminium paint over a coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing FRLS PVC insulated cables aluminium conductor, stranded 4 Sqmm 2 Core, etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing sintex box of size 200x175x100mm for street ligt control box including 10 Amps SP, MCB etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC(1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC (1:2:4) type B-2 using 40mm grade stone aggregates for coping and similar work etc complete all as specified and directed by Engineer-in-Charge
Supply & Fixing street light fitting (LED) type 60 watt pressure die cast aluminium housing with beat resistant tougened glass & IP66 protection and wired with all accessories etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing GI pipe (light grade) Bracket for street light dia 50mm bore including making bends as required etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep BEE 5 star rated etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing exhaust fans PVC body AC single phase 230/ 240 V of size 250 mm sweep with louver etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One fan point controlled by switch 5 Amp single pole one way
All as per Item No 41 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
Supply & fix Fan regulator step up type etc complete all as specified and directed by Engineer-in-Charge
Supply & fix replacemnt industrial type switch socket for Geyser/heater with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge
Taking down existing ACSR of any size etc complete all as specified and directed by Engineer-in-Charge
S&F High galvanize mast light 20 mtr height including 08 LED flood light 200 Watt symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation, etc complete all as specified and direced by Engineer-in-Charge. (Note : (i) Cost of excavation, RCC foundation is included in the quotated rate Model of flood light - 200 W Bajaj - Cat Part No BJFL200W or equivalent in list of makes in Appendix `C' Make of Pole : Cat part No.BHMRL20A or equivalent in Jindal & Surya Notes : Eraction/installation and commissioning of the High Mast system comprising of foundation, mast and its accessories, avation warning lamps, earthing, luminaires, control panel etc with the help of suitable equipments. 3 sets of wiring/connection diagram, O&M manual to be supplied along with the high mast. The type and make of the luminaire and lamp to be furnished in the offer. Technical leaflet giving the dimensions, features to be attached with the offer. The fitting and control gear boxes offered should be suitable for outdoor application and properly sealed to prevent rain water entry.
General Features : Winch The winch shall be of completely self sustaining type, without the need for brake shoe, springs or clutches. Each driving spindle of the which shall be positively locked when not in use. Individual drum also should be operated for fine adjustment of lantern carriage. the capacity operating speed safe working load, recommended lubrication and serial number of the winch shall be clearly marked on each winch. The winch drums shall be grooved to ensure perfect seat for stable and tidy rope lay with nochances of rpe slippage. The rope terminaation in the winch shall be such that distortion or twisting is eliminated and at least 5 to turns of rope remains on the drum even when the lantern carriage is fully lowered and rested on the rest pads. It should be possible to operated the winch manually by a suitable handle by an integral power tool.
Head Frame The head frame, which is to be designed as a capping unit of the mast, shall be of welded steel construction, galvanised both internally and externally after assembly. The top pulley shall be of appropriate diameter, large enough to acommodate the stainless steel wire ropes and the multicore electric cable. The pulley block shall be made of non corrodable material, and shall be of die cast aluminium alloy. Pulleys made of synthetic materials such as Plastic or PVC are not acceptable. Self lubricating bearings and stainless steel shaft shall be provided to facilitate smooth and maintenance free operation for a long period. The pulley assembly shall be fully protected by a canopy galvanised internally and externally. Close fitting guides and sleeves shall be provided to ensure that the ropes and cables do not get dislodged from their respective positions in the grooves. The head frame shall be provide with guide and stops with PVC buffer for docking the lantern carriage.
Stainless steel Wire Ropes : The suspension system shall essentially be without any internmediate joint and shall consist of only non corrodable stainless steel of AISI 316 or better grade. The stainless steel wire ropes shall be of suitable size the central core being of the same material. The overall diameter of the rope shall not be less than 6mm. The thimbles shall be secured on ropes by compression splices. Two continuous lengths of stainless steel wire ropes shall be used in the system and no intermediate joints are acceptable in view of the required safety.No intermediate joints/terminations, either bolted or else shall be provided on the wire ropes between winch and lantern carriage.
Electrical System, Cable and Cable connections A suitable terminal box shall be provided as part of the contract at the base compartment of the high mast for terminating the incoming cable. the electrical connections from the bottom to the top shall be made by special trailing cable. Size of the cable shall be minimu 5 core 2.5 sqmm copper. At the top there shall be weather proof junction box to terminate the trailing cable connections from the top junction box to the individual luminaries shall be made by using 3 core 1.5 sqmm copper flexible PVC cables of reputed make. The syestem shall be in built facilities for testing the luminaries while in lowered position, Also suitable provision shall be made at the base compartment of the mast ot facilitate the operation of internally mounted, electrically operated power tool for raising and lowering of the lantern carriage assembly. The trailing cables of the lantern carriage rings shall be terminated by means of metal clad, multipin plug and socket provided in the base compartment to enable easy disconnection when required.
Power Tool for the Winch: A suitable high powered electrically driven internally mounted power tool with manual over ride shall be supplied for the raising and lowering of the lantern carriage for maintenance purposes. The speed of the poser tool shall be to suit the system. The power tool shall be single speed, provided with a motor of the required rating. The power tool shall be supplied complete with suitable control. The capacity and speed of the electric motor used in the power tool shall be suitable for the lifting of the design load installed on the lantern carraige. The power tool mounting shall be so designed that it will be not only self supporting but also aligns the power tool perfectly with respect to the winch spindle during the operations. Also a handle for the namual operation of the winches in case of problems with the electrically operated tool shall be provided. Lightning Finial : One number heavy duty not dip galvanised lighting finial shall be provided for each mast. the lightning finial shall be minio=mum 1.2 M in length and shall be provided at the centre of the head frame. It shall be bolted solidly to the head frame to get a direct conducting path to the earth through the mast. Aviation obstruction Light : set of two Aviation obstruction lights of reliable design and reputed manufacturer shall be provide on top of each mast. Make : Cat part No. 110731 Lumnare type BGAV302 LED of Bajaj or equivelent in make mentioned in list of makes in Appendix `C'.
Feeder Pillar: Supply , installing , commissioning and testing of panel board out door Kisko Type , Cubical type , factory made vermin protected, dust proof, water proof made out of MS sheet 14 SWG thick with Cts suitable size including locking arrangements including following:- (a) Copper busbar suitable for 100 Amps capacity TPN with insulators-01 Set. (b ) MCCB 63 Amp TP 16 KA-01 Nos (c) Timer switch (Analog)-01 No (d) Contactor 63 Amps, 3 pole 415 Volt -01 No (e) Digital Voltmeter 0 to 500Volt) -01 No (f) Digital Ameter 0 to 100 Amp with CT's -01 No Power Cable : A cable of size 4 x10 sqmm aluminium conductor armoured cables for power supply and 4 x 1.5 sqmm copper conductor armaoured cable for motor supply shall be provided from feeder pillar to the base compartment of the highmast. Cable shall be taken to the base compartment of the highmast through the provision made in the foundation.
Fixing only LT bulk head metre etc complete all as specified and directed by Engineer-in-Charge Note : Meter will issued under Schedule `B'
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body etc complete all as speccified and directed by Engineer-in-Charge
An amount of Rs 97,693.00 shall be deducted from BOQ on account of schedule of credit
metro electrical services
M/s. N D Karande
AZAD SERVICES
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .