Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.9 L+₹8,170 (0.69%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹12.8 L+₹92,969 (7.84%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹13.3 L+₹1.4 L (11.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹14.7 L+₹2.8 L (23.9%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR208008
COMPREHENSIVE MAINT REPAIR OF CHLORINATION PLANT AND OTHER ALLIED WORKS INCLUDING REPAIR TO GEYSER IN DOMESTIC AREA AT AF STATION CHAKERI KANPUR
2021_MES_476127_1
8525/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹40,000
Yes
4 Dec 2021
18 Sept 2021
26 Oct 2021
18 Sept 2021
21 Oct 2021
7 Oct 2021
60 days
Amount
Taking down carefully geyser (storage type) of any make of capacity 25/35/50 Ltrs at any height disconnecting electrically and mechanically from all existing line opening complete including back plate, inner copper tank etc. de-scaling of copper tank , heating element and cleaning with Sulphuric Acid / de-scaling compound and reassembling and fixing in same position after necessary repair / replacement including replacement of old nuts & bolts and rubber gasket etc in side the geyser complete all as specified and directed. Note :- (i) Replacement of unserviceable spares shall be measured and paid separately under appropriate items of Schedule 'A' . (ii) Inspection of electric geyser any capacity, any type, any make for minor defect tightening of nut and bolts, connecting wire, pipe lines and rectifying the defects.
Supply only heating element 2000 watt capacity push / screw type with 'O' ring including making electrical connection complete all as specified and directed. Make:- Theeta/ Bajaj or any make approved by GE
Supply only thermostat switches ISI marked including making connections complete all as specified and directed. Make:- Theeta/ Bajaj/Racold
Supply only indicating lamp round/triangular red/green 220 volt AC as required at site including electrical connections complete all as specified and directed.
S&F in repair PVC connection 600 mm long with two nos nut adopter ISI marked for hot/cold water complete all as specified and directed. Make:- Paras/ Prayag or any make approved by GE
S&F in repair PVC connection 750 mm long with two nos nut adopter ISI marked for hot/cold water complete all as specified and directed. Make:- Paras/ Prayag or any make approved by GE
S&F in repair door assembly with element push type with 'O' ring and square ring for 25 ltrs capacities geysers complete all as specified and directed. Make:- Bajaj/Summer cool or any make approved by GE
M&L in repair for soldering/brazing of inner tank of geyser of any type & capacity as required to make its functional complete all as specified and direected
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe 15 mm dia bore complete all as specified and directed.
All as per serial item No. 9.00 above but cast copper alloy chromium plated complete all as specified.
M&L in repair 3 core PVC sheathed copper conductor flexible cable of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Paragaon/Havells
S&F inner steel tank of capacity 25 litre Geysers complete all as specified and directed. Make: - Bajaj/Summer cool or any make approved by GE
S&F in repair single pole and neutral enclosure 20 Amp with a two pin and earth plug and socket with one single pole MCB 20 Amp complete all as specified and directed. Make:- Legrand/L&T/Seimens
S&F in repair single pole MCB 16 Amp 10 KA, C curve complete all as specified and directed. Make:- Legrand/L&T/Seimens
S&F in repair pressure release valve of suitable size in geyser complete all as specified and directed.
S&F in repair fastener of suitable size complete all as specified and directed.
S&F plug top 5 Amp 3 pin 230 volt complete all as specified and directed. Make:- Anchor/Plaza/SSK
Repair / maintenance of chlorine granuals based dosing plant comprising dosing pump, agitator and 100 ltr FRP tank (Make- Declibac ) and connected pipe lines as per manufacturers recommendation which include the following complete all as specified and directed:- (i) Cleaning of chlorine plant room once in a week. (ii) Daily Checking of all Chlorination plants /testing of complete system for serviceability of plant. (iii) Daily Testing of chlorine at consumer end with medical authority and maintained chlorine test record . (iv) Minor repair/cleaning of PVC pipe line /NRV to make plant functional. (v) Routine maintenance and servicing of agitator of by using necessary lubricant, replacement of bush/bearing, aligning the shaft , key etc. Notes : (a) Any other spares required for replacement shall be measured and paid under relevant item of BOQ. (b) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfect the contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day.
Supply only gear motor 230 volt,50 Hz for chlorine dosing pump complete all as specified and directed.
Supply only roller assembly complete all as specified and directed.
Supply only PVC pump tube as per sample complete all as specified and directed.
Supply only injection check valve 3/8" size complete all as specified and directed.
Supply only weighted suction line strainer 3/8" size complete all as specified and directed.
Supply only white suction /discharge tubing 3/8" size complete all as specified and directed.
Supply only agitator motor with suitable capacity alongwith agitator shaft & impeller made poly propylene rigid 32 mm dia and 500 mm length complete all as specified and directed.
Supply only pump head complete all as specified and directed.
Supply only check valve duck bill complete all as specified and directed.
Supply only dosing tank complete all as specified and directed. Make:- Declibac Technologies (P) Ltd. / Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts
Supply only chlorine tablet feeder with proportion dosing arrangement by differential pressure complete all as specified and directed. Make:- Bharti Water/ Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts/ Declibac Technologies (P) Ltd.
Supply only chlorine tablets of size 50.80 mm in diameter packed in plastic sealed in disposable packet with arrangement for appropriate water contact with the tablets and circulation through the plastic packet ,suitable for operation through suitable feeder for disinfection of water pressurised line complete all as specified and directed.. Make:- Bharti Water/ Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts/ Declibac Technologies (P) Ltd.
Supply only calcium based high strength granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution , free of foreign matter , the chlorination chemical should contain appropriate quantities of dispersants, corrosion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminants in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. Make:- Bharti Water/ Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts/ Declibac Technologies (P) Ltd.
M&L for rewinding of agitator motor of capacity 120 watts, 960 RPM single phase 230 V and using copper winding wire of existing gauge with necessary insulation material including testing after repair and refixing of the same complete all as specified and directed.
M&L for cleaning of RCC over head tanks inside dome i.e. bottom & wall of dome 17 m to 26 m staging by de-watering through wash out pipe line, scrapping sludge and removal the same through washout pipe line and applying two coats of white wash on internal surfaces and writing date of cleaning of tank with white paint on black base complete all as specified and directed for capacity 100000 Gallons Capacity Tank.
All as per item No 33.00 above but 70000 Gallons Capacity Tank.
All as per Item No 33.00 above but 50000 Gallons Capacity Tank.
All as per Item No 33.00 above but 20000 Gallons Capacity Tank.
M&L for cleaning of RCC underground sump inside by Mechanised de-watering by using submersible pump, scrapping sludge and removal by using industrial sludge pumping, cleaning of all dust particle, sterilization of sump by using chlorination chemical on internal surfaces of wall including preperation of surfaces and applying two coats of white wash on internal surfaces and writing date of cleaning of sump with white paint on black base complete all as specified and directed for capacity 375000 ltrs capacity tank.
All as per item No 37.00 above but 200000 ltrs capacity tank
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .