PRAMESH Kumar
ED - Hisar
Construction of EVM and VVPATs Warehouse (4000 Unit) in the Campus of Mini Secretairt Complex at Hisar (Pdg. Spare Cable for 11 KV Substation )(Balance work)
2026_HRY_500083_1
2026795F999D 58B1 4E8F AFC1 7DD9B009C913666BAR
Open Tender
Electrical Works
Works
30 days
Hisar
2 documents required · 2 mandatory
₹500
₹8,019
Yes
9 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
[24.16.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 core [Through Rate]
[24.16.9]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 9. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 300 Sq mm 3 core [Through Rate]
[24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate]
[24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm [Through Rate]
[24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate]
NS Item -DSR No 8.17 ,LED Flood Light, powder coatedpressure die cast aluminium (System lumen efficacy )135lm/Watt) Supplying, Installation, Testing and Commissioningof Flood Light, powder coated pressure die cast aluminiumbody with built in or separate driver as per the requirementwith Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0Cto 50 0C, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC61000-3-2, P. F.=0.95, IP-66,IK-10, CRI )70,under voltageand over voltage protection EMI-EMC as per CISPR-15,lenses for beam angle 30 deg-120deg as perthe applicationand the project requirement., suitable tilt able fitting, life time(LED, Driver and electrical circuitry) of minimum50000Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-2111report, CCT3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM (Standard Deviation Colour Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output. LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C DSR No. 8.17.6 ( 200 W Flood Light ) Make :- Phillips , Wipro , surya,bajaj Rates Are exclusive Gst
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_578685.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .