| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAdmitted-Finance 17 18 NAVKETAN INDUSTRIAL ESTATE MAHAKALI CAVES ROAD OPP ONIDA ANDHERI EAST MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | ₹4.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.7 Cr+₹1.2 Cr (25.4%)Admitted-Finance 210 211 RAJRATAN IND ESTATE OPPOSITE SNDT COLLEGE EXTN RAMCHANDRA LA MALAD W MUMBAI 400064 KANCHPADA MALAD WEST MUMBAI MAHARASHTRA 400064 MUMBAI CITY MAHARASHTRA 400064 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | ₹5.7 Cr+₹1.2 Cr (25.4%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Insight Business Machines Pvt Ltd L2 | MICROPOINT COMPUTERS PVT. LTD. L1 |
|---|---|---|---|---|---|
| 1.00 | Part - A : Smart Rack, IT and Associated works. | 1 | Nos | 2,40,48,907.25 ₹2,40,48,907.25 | 2,09,48,240 ₹2,09,48,240 Lowest |
| 2.00 | Part - B : Civil Works | 1 | Nos | 10,20,760 ₹10,20,760 | 4,61,500 ₹4,61,500 Lowest |
| 3.00 | Part - C : AMC | 1 | Nos | 35,22,540 ₹35,22,540 | 13,98,000 ₹13,98,000 Lowest |
Tender Value
₹2.6 Cr
EMD Value
₹5.3 L
Closing Date
13 Aug 2024, 5:00 pmClosed
Chief Engineer (ESG)
DCSEM, 3rd Floor, V.S. Bhavan, Anushaktinagar, Mumbai - 400094.
Design, Supply, Installation, Testing and Commissioning of Integrated Smart Rack Modular infrastructure system at OYC, Apollo Bunder, Mumbai
2024_DCSEM_813287_1
DCSEM/CQD/QSC/ OYC-Rack/NIT/13/24-25 dt 24.06.2024
Open Tender
Job Works
Works
1170 days
OYC, fort
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹5.3 L
1 Oct 2024
27 Jun 2024
16 Aug 2024
27 Jun 2024
13 Aug 2024
27 Jun 2024
27 Jun 2024 - 12 Jul 2024
Amount
Part - A : Smart Rack, IT and Associated works.
Part - B : Civil Works
Part - C : AMC
Description of Work / Item(s)
Amount
PART A : Smart Rack, IT and associated works Design, Supply, Installation, Testing and Commissioning of Integrated Smart Rack Modular infrastructure system with precision Air conditioning, UPS, smoke detector, fire alarm & fire supression, rodent repalant, environment monotoring, remote monitoring, alarms & logging,access control, power distribution etc. as per relavant standards, specifications and instruction of Engineer in charge. NOTE:- Entire work specified in this tender should be carried out complete in all respect and scope includes all accessories and materials for sucessful installation and commisioning of modular smart rack system
42U Racks (800mm X 1200mm) with mounting hardware, copper earthing strips etc as per specifications along with all accessories.
PAC system in N+1(with max N=4) configuration with copper pipings and accessories as per specifications.
40 kW modular UPS with Li-Ion battery pack for 15 mins backup with all elctrical works and accessories as per specifications
Fire alarm and fire supression system for above smart racks
Fire supression system for UPS and battery room. To be integrated with above fire alarm system.
Fire supression system for UPS and Li-ion battery room. To be commisioned at VS Bhavan of similar size and specification and to be integrated with existing fire alarm system.
Environmental monitoing
Remote monitoriong
Alarms and logging
Access control and biometric reader
Rodent repellent system
Metered PDU with min 24 nos. of C13 Sockets & min 6 nos. of C19 socket with 32A MCB.
1-phase rack mountable horizontal (1U) Switched PDU as per specifications.
HMI display and intergration with monitoring, alarms and logging system
Power distribution Electrical Distribution Board, cables, tray and load transfer switch
C13-C14 rated for 10 amps female to male power cords of 2 mtr. Length.
C19-C20 rated for 20 amps female to male power cords of 2 mtr. Length.
Cable and accessories Note:Unused qty (Except fusion spling) shall be kept as spares for future use.
Supply, Installation, Testing and Commissioning of LSZH CAT 6 UTP cable in existing PVC trunkung/ conduit/on wall/column/Ceiling/beam/surgace/false ceiling/as per latest EIA/TIA standards all as per instructions of Engineer in Charge.
Supply, installation, crimping, testing and Commissioning of CAT 6 RJ 45 plugs/connectors as per latest EIA/TIA standards all as per instructions of Engineer in Charge.
Supply, Installation, Testing and Commissioning of 24 port, 19" rack mountable, CAT 6 UTP Patch pannel
Supply and Installation of 24 port, duplex, fully loaded with SC adapters and pig tails, spool and splice trays, 19" rack mountable, LIU suitable fo single mode OFC
Supply and installation of single mode SC-LC, duplex OFC patch cords of 30m length
Supply and installation of single mode LC-LC, duplex OFC patch cords of 5m length
Supply and installation of single mode SC-LC, duplex OFC patch cords of 3m length
Supply and installation of single mode SC-SC, duplex OFC patch cords of 3m length
Supply and installation of single mode SC-SC, duplex OFC patch cords of 15m length
Fusion splicing
Supply and testing of Micro scanner for CAT 6 cable with feature of indicating fault distance, cable length, wiremap, ca short circuit, open crcuit, split pair etc.
Shifting of existing IT infrastructure including racks, servers, switches, routers, desktops, KVM switches, firewall, cables rerouting and retermination including OFC etc. to nearby new location on same floor, establishment of connections at new location using above cabling items, whereever required, commissioning (Restoration of all services) all as per instructions of Engineer in Charge. Further, Installing back of the infrastructure except racks in original room after completion of work at item number 1 above all as per instructions of Engineer in Charge. Scope includes restoration of all services as original or as instructed by Engineer in charge. Note: 1. For completion of this item, envisaged work includes supply, installation and removal all the material/consumables which may not be specifically mentioned but required for completion. 2. Scope includes disposal of unused old items at designated place in the premises as per instructions of Engineer in charge.
Supply, Installation, Testing and Commissioning of layer 3 Ethernet switch with a) 24 numbers of SFP+ ports supporting 10G BASE SFP+ / 1G BASE SFP modules and SFP+10G BASE-T Transceiver Copper RJ45 Module, 10G BASE SFP+ / 1G BASE SFP modules- 12 Nos, SFP+10GBASE-T Transceiver Copper RJ45 Module- 12 Nos., 4 numbers of 40Gigabit QSFP+ ports supporting 40G Base-LR4 modules. Equiped with 1) SFP+ module (10G base-LR) with 10 Gigabit speed, 10 Km 12 Nos. 2) SFP+10GBASE-T Transceiver Copper RJ45 Module - 12 Nos. 3) Equiped with QSFP+ module (40G BASE-LR4)- 04 Nos. b) The switching engine (Back plane) should have a switching speed of at least 800Gbps All as per specifications, standards and instructions of Engineer in charge. Note: The port capacity should be obtained without stacking
Supply, Installation, Testing and Commissioning of 2 nos UTM (Firewall) in high availability all as per specifications, standards and instructions of Engineer in charge.
Description of Work / Item(s)
Amount
PART B : Civil works Providing and laying scratch resistant, easy to clean, maintenance free vinyl flooring including skirting of appropriate size and 2 mm thick of M/s Stilex or equivalent make and approved pattern and shade including necessary adhesive over the IPS / Mosaic flooring / skirting including cutting to the required size and shape on edge including wastage, removal of existing damaged PVC or other flooring and disposing of debris / unserviceable material etc., cleaning the floor before and after the completion of works all as per manufacturer's specifications and as per drawing and as directed by the Engineer-In-Charge.
Painting of old painted cement plastered/wood /steel surface as mentioned below using enamel paint, acrylic emulsion paint of 1st quality of approved make & shade applying a coat of approved cement/steel /wood primer, filling up the cracks with approved crack filling compound, applying approved stucco putty to entire surface to fill up crevices, mild depression etc. thoroughly scrapping the surface, apply two coats of following paint including necessary covering material and removal of splashing & droppings from floors, walls including scaffolding, ladder as required & disposing of debris from site etc. complete all as directed by the Engineer-in-Charge. Note: Scope includes providing & applying cement based wall care putty in one coat of Birla wall care putty of M/s Birla or stucco putty of M/s Jotun or Champion putty of M/s Saint Gobain Gyproe India or other approved equivalent make over entire surface including preparing old painting surfaces by thoroughly scrapping oil bond distemper / acrylic emulsion paint / white washing including scaffolding, sand papering, removal of debris and disposing off the same to the MCGM dumping ground or at a nearby dumping ground etc. complete all as directed by the Engineer-in-Charge.
On wooden surfaces in two coats of synthetic enamel paint without primer
On cement plaster surfaces with two coats of 1st quality acrylic emulsion paint excluding cement primer
On cement plaster surfaces with two coats of 1st quality acrylic emulsion paint over a one coat of approved primer
Supplying, fabricating and fixing in position at all floors and levels aluminium section in partition, doors etc. with rivit joint of specified size, made of integrated bronze anodised matt finished (15micron thick) aluminium section (extruded) ,handles of specified size etc., of approved manufactures for following types with extruded sections of Jindal / Indal / Aluminax or other approved equivalent make of approved sections with size and weights as directed for frames and shutters(including wastages if any) confirming to relevant IS specifications including necessary bronze anodised screws, grouting the gap with sealant etc all complete generally as per specifications etc, all as directed by Engineer in charge.
Providing & fixing of 5.0 mm thick Titanium blue (performance glass) toughened glass for existing MS openable/louvers or aluminium sliding windows, glass doors, vision panels etc of approved make in various sizes as required at site, using first class glass oil putty of approved quality and make including supplying & fixing glazing pins, teak wood or aluminium beading, EPDM gasket etc. with necessary screws, nails etc. (as required) including cutting the glass to required size, removing the existing broken / damaged glass panes from windows / doors / partitions etc. along with its old oil putty/gasket /beading etc. carefully and disposing off the un-serviceable material at a designated place within in the premises including wastage in cutting, transportation etc. complete all as directed by the Engineer-in-Charge.
Providing and fixing of Hydraulic (universal) heavy duty door closer conforming to IS:3564 of M/s Everite/M/s Garnish/M/s Hyper to the existing door shutter / new door shutters including removing and refixing the shutters carefully and cutting, fixing door closer with all fittings, screws, tools, labour etc. complete all as directed by the Engineer-In-Charge.
Providing and fixing floor springs of Rolex brand or other approved equivalent to the existing door shutter /new door shutters including removing and refixing the shutters carefully and cutting the niche at top one corner to accommodate door closer with all fittings, screws, tools, labour etc complete all as directed by the Engineer-In-Charge.
Providing and fixing superior quality vertical blinds of M/s. VISTA or approved equivalent manufacturer with approved best quality fabric of required shade and colour, all accessories required for fixing in position all as per approved sample, design, pattern complete all as directed by the Engineer-In-Charge. Note: Mode of measurement shall be length of aluminium top runner x height from top of channel and up to bottom of blind.
Providing and fixing of Vista or approved make Roller Blinds at locations including material, labour, tools and plants etc. complete as per instruction of Engineer-In-Charge. Note: Mode of measurement shall be length of aluminium top runner x height from top of channel and up to bottom of blind.
Providing and applying approved quality and approved colour silicon sealant through pressure gun on aluminium joints / gaps between wall and sections as per specification in position all as per approved sample, design, and pattern complete all as directed by the Engineer-In-Charge.
Demolishing existing brick work including plaster in cement mortar at all levels including scaffolding, stacking of serviceable material within 300 m lead and disposal of unserviceable marital outside of OYC / AnushaktiBhavan premises etc. complete all as directed by the Engineer-In-Charges.
Providing and fixing in position at all floors, levels / heights 18 mm thick mirror polished natural stones slab for windowdoor frame in two overlapping layers one piece full length / height of approved shade, finished sizes as directed including machine cut / hand cut, final cleaning, moulding and polishing of exposed edges, in line, level, plumb and fixing the stone with cm 1:3, 20mm backing & overlapping of 20 mm shall be fixed with Araldite adhesive, with best workmanship, finishing, curing, including removing existing door frame, shutter & fittings etc. and depositing the same at dept. store etc. complete all as per specifications, drawings & as directed by the Engineer-in-Charge
Film on glass window pane of 3M make (3M Sun Control Window Films, Night Vision Series, Night Vision 15) or equivalent approved make with protection from Sun light, UV and IR in data centres at Anushakti Bhavan and V S Bhavan.
Description of Work / Item(s)
Amount
PART C: AMC Comprehensive Annual Maintenance contract (CAMC) of the above facility for 3 years after defect liability period (DLP) of 1 year. Quarterly PM to be carried out during the AMC period. Repair, replacement, refilling, top up etc of the required items including consumables without any additional cost. On call maintenance person/engineer site visit to resolve the problem.
CAMC for 1st Year
CAMC for 2nd Year
CAMC for 3rd Year
Insight Business Machines Pvt Ltd
Insight Business Machines Pvt Ltd
Insight Business Machines Pvt Ltd
Insight Business Machines Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.91 MB
TechdatasheetOYCRack.xls
Tender Documents • 0.08 MB
BOQ_854696.xls
BOQ • 0.34 MB
DetailedNITOYCRack.pdf
Tender Documents • 0.89 MB
TechBidSGFOYCRack.pdf
Tender Documents • 1.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .