| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 CrAdmitted-Finance | ₹33.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹35.6 CrAdmitted-Finance NOT SPECIFIED | ₹35.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹37.7 CrAdmitted-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹37.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹39.3 CrAdmitted-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹39.3 Cr | L4 | Admitted-Finance |
| 5 | L5₹48.7 CrAdmitted-Finance VILL AZARA BHARALIPARA PO PS AZARA DIST KAMRUP M ASSAM PIN 781017 | KAMRUP METRO | ASSAM | 781017 | ₹48.7 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Singh enterprises L3 | United Sales Corporation L2 | M/S PRASANTA MAHANTA L5 | Shree Shyam Enterprise L1 | ms singh construction L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE "A" Part - I
(BUILDINGS/STRUCTURES WORK)
Details of Buildings are given here-in-before:- | 1 | Lump sum | 33,31,46,520 ₹33.3 Cr | 32,00,00,000 ₹32 Cr | 34,11,22,200 ₹34.1 Cr | 29,00,00,000 ₹29 Cr | 35,00,00,000 ₹35 Cr |
| 2.00 | SCHEDULE "A" PART- II
( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 13,41,966 ₹13.4 L | 13,41,966.05 ₹13.4 L | 14,01,300 ₹14.0 L | 13,40,000 ₹13.4 L | 13,00,000 ₹13 L |
| 3.00 | SCHEDULE "A" PART- III
( INTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 91,08,539 ₹91.1 L | 90,00,000 ₹90 L | 1,20,67,000 ₹1.2 Cr | 90,00,000 ₹90 L | 1,00,00,000 ₹1 Cr |
| 4.00 | SCHEDULE "A" PART-IV
( INTERNAL WATER SUPPLY )
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 24,23,405 ₹24.2 L | 20,00,000 ₹20 L | 21,51,300 ₹21.5 L | 16,00,000 ₹16 L | 18,00,000 ₹18 L |
| 5.00 | SCHEDULE "A" PART- V
(ROAD/PATH)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 1,38,59,078 ₹1.4 Cr | 95,00,000 ₹95 L | 1,26,51,390 ₹1.3 Cr | 87,50,000 ₹87.5 L | 1,00,00,000 ₹1 Cr |
| 6.00 | SCHEDULE "A" PART- VI
(AREA DRAINAGE)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 8,58,531 ₹8.6 L | 5,75,000 ₹5.8 L | 6,93,200 ₹6.9 L | 5,36,580 ₹5.4 L | 10,00,000 ₹10 L |
| 7.00 | SCHEDULE "A" PART- VII
(SEWAGE DISPOSAL)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 5,95,092 ₹6.0 L | 4,25,000 ₹4.3 L | 8,42,100 ₹8.4 L | 3,60,000 ₹3.6 L | 7,00,000 ₹7 L |
| 8.00 | SCHEDULE "A" PART- VIII
(FENCING AND GATE )
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | 8,83,934 ₹8.8 L | 9,25,000 ₹9.3 L | 9,18,627 ₹9.2 L | 8,80,000 ₹8.8 L | 12,00,000 ₹12 L |
| 9.00 | SCHEDULE "A" PART- IX
(EXTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | - | - | - | 15,50,000 ₹15.5 L | - |
| 10.00 | SCHEDULE "A" PART- X
(EXTERNAL ELECTRIC SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 18,81,766 ₹18.8 L | 15,00,000 ₹15 L | 21,01,900 ₹21.0 L | 14,25,000 ₹14.3 L | 20,00,000 ₹20 L |
Tender Value
₹20.5 Cr
EMD Value
₹13.5 L
Closing Date
4 Jun 2025, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF DEFICIENT MD ACCN FOR OFFICERS AND AIRMEN AT AF STN DINJAN (PH-I)
2025_MES_694139_1
88663/DIN/E8
Open Tender
Civil Works
545 days
Dinjan
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (AF) Mohanbari
₹13.5 L
Yes
16 Jun 2025
21 Jan 2025
6 Jun 2025
25 Mar 2025
4 Jun 2025
21 May 2025
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (ROAD/PATH) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (FENCING AND GATE ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XI (MISCELLANEOUS ITEMS) Note:- Srl Item No. 9.00 and this schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION Supply and fixing Modular metal flush box with modular white cover plate with frame 8 module complete all as directed and specified.
Supply and Fixing LED decorative light fitting 10W, 220 V, AC including LED light connecting up wih three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED security light fitting not less than1X35 watt with integral reflector made of alluminium alloy LM6 with LED dirver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5 meter long bend to shape of dia 25/40 mm GI medium grade pipe with MS clamp all as specified and directed.
S&F TV socket single moudle, polycarbonate type complete with box all as specified & directed.
S&F wall mounted fan plastic body, single phase, 230 volts, 50 Hz of size 400 mm sweep, heavy duty type with flexible three core copper conductor cable of suitable size and 5 Amp plug all as specified and directed (for officer quarters)
M&L, testing,installation,commissiong of Kitchen Exhaust System (Chimney), Filter Less and Dry Heat Clean Technology / Matt Black Finish, Hassle free and dry Heat Auto Clean Technology, Thermostatic Touch Control Panel with 3 speed Gesture Motion, including Matt Black Finish, Black Metal Oil Collector, Motor with Copper Winding, Black Glass Clad Hood with LED Insignia, Front Panel with Black Glass, Energy Saving LED Light,Metal Blower+ Metal Housing,Designed Air Flow (max),: 1250Nm3/h, Noise level :58 dBA (max), 5 years Warranty, Size:90Cm complete all Civil work for fixing system,including fixing of Duct and complete Electrical wiring upto the socket point as required for system running complete all as specified and directed. (only for officer quarters)
Supply and fix MCCB 415 Volts, 4 Pole, 100 Amps, 50 Hz, 25 KA with thermal magnetic release type complete all as specified and directed.
Supply and fix MCCB 415 Volts, 4 Pole, 63 Amps, 50 Hz, 25 KA with thermal magnetic release type complete all as specified and directed.
Supply and fix MCB 230 Volts, 50 Hz, SPN, 16 Amps, 10 KA with "C" curve complete all as specified and directed.
Supply and fix MCB 230 Volts, 50 Hz, Single Pole, 63 Amps, 10 KA with "C" curve complete all as specified and directed.
M&L for Single Phase sub main wiring with 4 run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm alongwith two run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm as earth continuity conductor drawn through and including concealed PVC conduit non metalic type rigid medium grade complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. (For Internal and External Electric Supply)
INTERNAL WATER SUPPLY S&F brass angle stop cock CP high pressure with capstan head long shank and cup fancy type, screwed down 15mm dia. bore complete all as specified and directed.
S&F pillar tap (Hot & cold) of 15mm bore, chromium plated, cast copper alloy with capstan head chromium plated screwed down high pressure fancy type, with or without lettered 'Hot' or 'Cold' with long screwd shank and fly nuts long neck, screwd for iron pipe, complete all as specified and directed.
S&F 2-way bib taps of bore 15mm, chromium plated, cast copper alloy with cruth or butterfly handle, chromium plated with long shank and wall flange, cup, concealed type screwd down for iron pipe, complete all as specified and directed.
SEWAGE DISPOSAL M&L for RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc. with vent shaft, manhole openings with cover connection etc. for 150 users as per shown in drawing complete all as specified and directed.
M&L for RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc. with vent shaft, manhole openings with cover connection etc. for 50 users as per shown in drawing complete all as specified and directed.
M&L for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC of for 150 users of size 3.0m dia.X 4.5m effective depth as per shown in drawing complete all as specified and directed.
M&L for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC of for 50 users and size 2.4m dia.X 3.0m effective depth as per shown in drawing complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply and laying 110mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
Supply and laying 90mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
Supply and laying 63mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
Supply and laying 32mm outer dia., 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked and bearing specification as per IS-15801, PP-R pipes, SDR 11 (PN-10) with PP-R plain fittings laid in trenches/walls/cellings or laying in floors complete all as specified and directed.
Supply and fix of CI Sluice valve of 100 mm dia. with steel spindle bronze gate & seating rings conforming to IS 14846-2000 class 1.0 PN with ISI marked including jointing materials such as rubber insertion gaskets, suitable size of nuts, bolts, washers etc. complete all as specified and directed.
Supply and fix of CI Sluice valve of 80 mm dia. With steel spindle bronze gate & seating rings conforming to IS 14846-2000 class 1.0 PN with ISI marked including jointing materials such as rubber insertion gaskets, suitable size of nuts, bolts, washers etc. complete all as specified and directed.
Supply and fixing PP-R Gate Valves (Brass Insert) of 32 mm bore of outer dia. complete including all fittings, complete all as specified and directed.
Supply and fixing PP-R Gate Valves (Brass Insert) of 63 mm bore of outer dia. complete including all fittings, complete all as specified and directed.
Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 100 mm dia. complete all as specified and directed
Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 80 mm dia. complete all as specified and directed
Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 50 mm dia. complete all as specified and directed
Construction of brick masonry valve pit of size 90cm x 90cm x 90cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 40 x 40 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast 150mm long made out of flat iron 40 x 6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 3mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm dia pad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Serial Item No. 48.00 (Contd....) Outgoing :- (a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 63 Amps with Fixed thermal and Fixed magnetic setting- 03 No (02 Outgoing for two Building+01 Spare) (b) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 32 Amps with Fixed thermal and Fixed magnetic setting- 01 No for street light (c) Supply and fixing Astronomical Timer switch along with contactor 3P 32Amps, 415V, 50Hz for street light controlling (d) Supply and fixing MCB SPN 16 AMps-02 Nos for parking sheds.
Serial Item No. 50.00 (Contd....) Outgoing :- (a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 25 KA of 160 Amps with fixed thermal and fixed magnetic setting- 03 No (For LT Sub Panel 1 and 2 Outgoing + 01 spare) (b) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 63 Amps with fixed thermal and fixed magnetic setting- 02 No (For Building 9 Outgoing + 01 spare) (c) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 32 Amps with fixed thermal and fixed magnetic setting- 01 No (d) Supply and fixing MCB SPN 16 Amps - 01 Nos (for parking sheds)
Serial Item No. 52.00 (Contd....) Outgoing :- (a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 63 Amps with fixed thermal and fixed magnetic setting- 05 No (For Building 1,2,3,4 Outgoing + 01 spare) & (For Building No 5,6,7,8 and 01 spare) (b) Supply and fixing MCB SPN 16 Amps - 05 Nos (for parking sheds)
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
M&L for earthing complete with copper plate 600mm x 600mm x 3mm thick electrode and 20mm x 3mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
Supply and fix LED street light 45 W with minimum lumen of 4500Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole including bracket for street light fitting of any size made out of GI pipe light grade 40 mm dia, 1.5 mtr length bend to required size and shape including provisiob of clamps and fitting in position and including two coat of aluminum paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix cable junction boxes IP 66 "halogen free and weather proof" for outdoor installation (with metric knockouts for cable entry) of minimum size 225 x 295 x 125 mm for 16/25 sq.mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 kA, 10 Amps and including minium 200 Amps aluminium busbar (04 Nos) with nuts, bolts & washers, complete all as specified and as directed.
Supply and fixing PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, three core of copper conductor for connection of street light fittings on pole / wall / pillar from junction box including termination clip etc complete in all respect including through GI tubing of size 20mm dia or all as specified or directed.
Supply, installation, testing and commissioning smart RF/Cellular/Hybrid (RF+Cellular) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facility with self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including SMC Meter Box of minimum size 250 X 250 X 160 mm or as suitable for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . The communication system shall support: (a) On demand energy transfer (b) Two way communication with DCU/HES (c) Clock Synchronisation facility with HES (Head End System) (d) Communication including different makes of meter shall be such that it should communicate with same DCU directly or via Mesh Network. (e) Meter Protocol shall be open interface system in accordance of transmission control protocol/internet protocol. (f) The cost of the meter would include 2 years recurring sim charges during the defect liability period. and DCU/RF communication/Repeter Meter cost as applicable for the AMI infrastructure.It will also include cost of integrating the meters with existing/proposed AMI.
Serial Item No. 59.00 (Contd....) Notes: (a) It would be possible to run the meter in both prepaid and postpaid mode (b) The meters would carry 5 year warranty. (c) The OEM would need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. The department would need complete support of the OEM to be able to integrate the meter with any software of the department choice.
All as per Item No. 59.00 above but for three phase, four wire, tamper proof , 415 V AC smart prepaid meter with SMC Meter Box of 350X270X200mm, complete all as specified and directed.
Serial Item No. 61.00 (Contd....) All as per Item No. (a) Remote smart meter data reading at configurable intervals (upto 1500 meters) (b) Acquisition of meter data on demand. (c) Two way communication with meter/DCU/MDMS. (d) Command for connect and disconnect the smart meter. (e) Audit report and event alarm logging. (f) Encryption of data for source communication. (g) Mantain time sync with DCU/meter. (h) Store raw data for duration of one week. (j) Setting of smart meter configurable parameter. (k) Communication device status and history. (l) Critical and non critical meter event like temer/power failure etc.
Supply and Setup of Meter Data Management (MDM) system including supply and configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be deemed for collecting the data from the meter to DCU and server and vice versa, make the data available in bidirectional mode ton the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise KVA allocation/tripping, tariff regulations, software customisations etc all as directed by the Engr-in-Charge. (ii) Secure Mobile App/PC Based/Swipe Machine/Online Payment Gateway for all users assigned by the BSO/GE. (a) 30 min instantenous data from all the meters for minimum seven parameters- Cumulative Energy, Power, Current, Voltage, Power Factor and Frequency. (b) Abstract Download for Monthly and quarterly billing survey data for cumulative energy and max demand and tampering features. (iii) Billing Module: The billing module capable to create data sheet for currency recharges, recharge history, maximum demand individually, user complaint registers, cheque/payment reconcillations, fixed charges, energy bill details etc. (iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.
Serial Item No. 62.00 (Contd....) (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export: The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Make of MDMS: Elmeasure/HPL/Secure or any Techno Commercially equivalent make approved by GE
Serial Item No. 62.00 (Contd....) Notes: The additional functional requirements of MDMS are as follows: (a) Asset Management: i) Meter Location (Apartment, shop, industry/address etc). ii) Consumer Information (Name, Account, ID etc) iii) Meter details (Meter No. 1 phase/3 phase, with or without relay etc). iv) Meter Configuration (Demand integration period, load profile capture period etc). v) GIS information (connection, feeder/transformer/pole etc). (b) Meter data: i) Accept meter data from HES process, store 1500 meter data at least for 6 month and analyze. ii) Schedule and on demand meter reads and pinging of meter. iii) Storage of all connected meter events and alarm. (storing of 5 years data or more via archiving) iv) Provide complete history and audit trail for all data for 30 days (configurable period) v) Handle net metering/meters at the same premises. vi) Manage at a minimum 15 mint interval data (c) Exceptions: i) Capture and log data exceptions, problems and failures and send emails/SMS.
Serial Item No. 62.00 (Contd....) (f) Reporting: i) Daily data collection report. ii) Usage exceptions iii) VEE validations failures. iv) Physical meter events (install, remove, connect, disconnect) and meter resent report. v) Meter flags. vi) Meter inventory. vii) Defective meters. viii) Interface exception reports between MDM and other subsystems eg. billing, outage etc. Integration of different devices of different makes/ equipment/software as per functional requirements including water charges, furiture charges and license fee.Software Note: (a) The software would be hosted either on GCC Server or on NIC Server. (b) The software would contain two year defect liability. (c) Rates deemed to include all operating expenses such as GPRS charges, hosting charges etc. (d) GE Bank account and one payment gateway would be provided by MES. The payment gateway would be integrated with the software in that situation.. (e) The software would be scalable and expandable for meters and system of different make complying with IS16444. The software would be able to consumer web services of the future projects if required.
Serial Item No. 62.00 (Contd....) (f) The software would enable the features of refund calculation in case of quarter vacation. (g) The software sample approval would be based in integration demontstraining of at least four makes of the meters (2 RF at least and 2 cellular at least) (h) The software would support other charges such as water charges, lices fee, furniture charges and other allied charges. (i) The software would allow supporting both prepaid and postpaid billing plans. Separate groups can be created for the same. (j) Meters should be capable of integration with existing AMI infrastructure if any as per IS:16444
Provision for comprehensive operation including maintenance including repairs/ replacement of defective meters/DCU and other associated components (software/hardware) required to make the system functional at all times including periodic charges of telecom operator, smart meter billing from completion of work till the completion of defect liability period of 2 years.They would include the following items: (a) Software AMC: This would include necessary up gradations in the software such as support to the chrome browser charges, android version charges, iOS version charges. These charges happen on frequent basis and the software would support all the charges. (b) Charges in the Government tariff structure: The Government tariff charges may require software upgrade. The same would be included in the AMC scope of work. (c) Recurring sim charges for DCU and meter as required. (d) Ensuring adequate database backup, up-gradations in the operating system, antivirus updates, data base upgrade etc in liaison with GCC service provider. (e) Reports development: The additional reports as needed for the success of the project would be developed. (f) The communication network monitoring and support. (g) Configuration of the repaired/replaced hardware (meter/dcu/repeater) in the system. (h) Trouble shooting and necessary actions to run the system as required. (j) Software bug fixing as and when required.
Hosting the system to Government Community Cloud in place of server for hosting and management of Supplied Software application with stanby server during the defect liability period of 2 years after completion of Phase-I Hosting the web based software GCC location cloud Note: The GCC location would be as per the approved MEITY list. In case a CSP is removed from the panel, the contractor would migrate to a new supplier.
Supply and fixing of all-in-one solar street light of 30watt including monocrystaline solar panel of 60Wp, new age lithium ferro phospate battary of capacity 12.8V/3.6Ah ,silicon encapsulated high effiicency MPPT charge controler, aluminium housing for battary box and mounting bracket mounted on 5mtr GI pole of medium grade complete including errection and foundation work all as specified and directed.
United Sales Corporation (BID ID -3312133)
M/s Singh enterprises (BID ID -3305114)
ms singh construction (BID ID -3311733)
M/S PRASANTA MAHANTA (BID ID -3313244)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid