Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹18.0 L Quoted ₹18.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹23.6 L+₹5.4 L (29.5%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹23.6 L+₹5.4 L (29.5%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹24.5 L+₹6.3 L (34.5%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹24.5 L+₹6.3 L (34.5%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹28.1 L+₹9.9 L (54.5%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹28.1 L+₹9.9 L (54.5%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹34.5 L+₹16.3 L (89.5%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹34.5 L+₹16.3 L (89.5%) | L5 | Rejected-Finance Rejected |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
17 Aug 2020, 6:00 pmClosed
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Special repairs to five BER 3 Ton split ACs in kautilya hall (Bldg No P-1) and three air handling unit (AHUs) AHU rooms, cooling tower and connected items of central AC plant at NDC under GE New Delhi, Delhi cantt
2020_MES_334951_1
CWE-ND/74/2019-20
Open Tender
Miscellaneous Works
Item Rate
90 days
Delhi Cantt
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE New Delhi
₹48,000
Yes
24 Sept 2020
18 May 2020
19 Aug 2020
18 May 2020
17 Aug 2020
3 Aug 2020
Amount
Supply, installation, testing and commissioning of Double Skin Floor Mounted Horizontal, Air Handling Unit for Dinning Hall having following accessories including dismantling of existing Air Handling Unit complete all as specified & directed. Make:-Zeco model No. ZDS-80 or equivalent in Trane /flakt woods group. (a) One AHU having Air quantity 8800 CFM ZDS-80 Model , GI coil casing/blank offs coil section with 4 row deep chilled water cooling coil having copper tube distributors with 12.7 mm tube dia 27 SWG thickness of tube ,4RD cooling copper header material and .15 mm plain alluminium fins with No. of fins per inch 11/12 along with connected fixing brackets etc. complete all as specified and directed . (b) One FC type fan having 560 mm diameter with fan speed 655 RPM, fan outlet velocity 8.15 m/s and shaft absorbing power of 3.59 KW, motor rating 5.5 KW, coil area 17.6 Sqft complete all as specified and directed . (c) The AHU consists of 50 mm thick box type (EU-4) pre filter synthetic type (non woven type) area of filter suitable to fit at AHU ,efficiency 90% down to 10 micron. (d) 4 Nos of cooling coil RD having 20 Sqft Filter Area of dimension 1810 mm X 1800 mm x 1400 mm complete al as specified and directed . Note:- Old AHU shall be deposited to MES store yard as directed by Engr-in-charge.
Supply, installation, testing and commissioning of Double Skin Floor Mounted Horizontal, Air Handling Unit for Lecture Hall having following accessories including dismantling of existing Air Handling Unit complete all as specified & directed. Make:-Zeco model No. ZDS-100 or equivalent in Trane /flakt woods group. (a) One AHU having Air quantity 9900 CFM ZDS-100 Model GI coil casing/blank offs coil section with 4 row deep chilled water cooling coil having copper tube distributors with 12.7 mm tube dia 27 SWG thickness of tube ,4RD cooling copper header material and .15 mm plain alluminium fins with No. of fins per inch 11/12 along with connected fixing brackets etc complete all as specified and directed . (b) One FC type fan having 560 mm diameter with fan speed 646 RPM, fan outlet velocity 9.17 m/s and shaft absorbing power of 3.93 KW, motor rating 5.5 kw coil area 19.8 sift complete all as specified and directed . (c) The AHU consists of 50 mm thick box type (EU-4) pre filter synthetic type (non woven type) area of filter suitable to fit at AHU ,efficiency 90% down to 10 micron. (d) 4 Nos of cooling coil RD having 20 Sqft Filter Area of dimension 1810 mm X 1800 mm x 1400 mm complete al as specified and directed by Engr-in-charge. Note:- Old AHU shall be deposited to MES store yard as directed by Engr-in-charge.
Supply, installation, testing and commissioning of induced draught cross flow type cooling tower of dimension 2526 mm X 5100 mm X 3305 mm upto 2.675 meter Pumping Head 1780 Kg shipping weight and 5570 Operating weight to cool 1080 USGPM of water from 97.5 degree Fahrenheit to 90 Degree Fahrenheit Temp at a designed wet bulb temperature of 83 degree Fahrenheit having 0.75% Evaporation Loss, 0.005% Drift Loss, 0.37% Blow-down Loss and 1.125% Make up Water Quantity with following accessories including dismantling of existing cooling tower complete all as specified & directed. Make:- 6.1 KF series Model 6122(TB) of PAHARPUR COOLING TOWERS or equivalent in BALTIMORE AIRCOIL CO. / MARLEY. (a) One H-3-6 type Gear drive Fan per tower of 72" diameter having Fan speed of 535 RPM with PVC Louvers and cast alluminium alloy Fan Blade, fan should be driven by Gearbox complete all as specified and directed . (b) One spiral Bevel type 20T series Gear Reducer having Ratio 2.71:1 and service factor 7.64 complete all as specified and directed . Note:- Old cooling tower shall be deposited to MES store yard as directed by Engr-in-charge.
Taking out of MS Tubing of any dia including all fittings such as elbow, socket nipple, union Tee Reducer of medium Grade laying on walls/ceiling/surfaces complete all as specified and directed.
Supply & laying MS tubing 100 mm bore medium grade including all fittings such as elbow, socket nipple, union Tee Reducer of medium grade laying on walls/ ceiling/ surface complete all as specified and directed.
Supply & laying MS tubing 150 mm bore medium grade including all fittings such as elbow, socket nipple, union Tee Reducer of medium grade laying on walls/ceiling/surface complete all as specified and directed.
S & F butterfly Valve, conforming to IS 13095, 150 mm(6") complete all as specified and directed . Make:-Zoloto/Kilroskar/Castle.
S & F butterfly Valve conforming to IS 13095, 100 mm(4") complete all as specified and directed . Make:-Zoloto/Kilroskar/Castle
M&L for compound girder made of steel plates to withhold the AHU vibration and balance the counter weight of Machine suitable to mount the AHU of above size 18010 mm x 1800 mm x 1400 mm complete all as specified and directed .
S&F energy efficient split type Aces inverter type cooling capacity 3 Ton with suitable compressor thermo sensor temp control air conditioner auto air swing with multi function remote control (cord less) rated power supply 230 Volts 50 Hz, having HFC refrigerant R-410a all as directed. Make: FAQ100CVEA OF DAIKIN / ASGA36FUTC of O GENERAL / Superio Extreme Mega of CARRIER
M&L for fixing copper tubing for delivery pipe with insulation, heavy duty inner dia 9 mm (3/8") for refrigerant for ACs complete all as specified and directed.
M&L for fixing copper tubing for delivery pipe with insulation, heavy duty inner dia 13 mm (5/8") for refrigerant for ACs complete all as specified and directed .
M&L for fixing of PVC pipe 25 mm dia with fittings for drainage of water from ACs complete all as specified and directed .
RUCHIKA ENGG.WORKS
SNOWY ENGINEERING INC
Flint India
RefAir Technical Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .