| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical C 1256 1257 JJ COLONY TIGRI SOUTH DELHI 110062 | SOUTH | DELHI | 110062 | Rejected-Technical Technically not Qualified |
Tender Value
₹8.2 L
Closing Date
27 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Supplying and Laying cable and E.I. work at Plasma Pyrolysis Plant Building in Academic area at IIT Delhi.
2022_IIT_684632_1
IITD/WORKS(SP- 3853)/2022
Open Tender
Miscellaneous Works
Works
30 days
Indian Institute of Technology Delhi
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
Exempted
9 May 2022
20 Apr 2022
28 Apr 2022
20 Apr 2022
27 Apr 2022
20 Apr 2022
60 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 16 kA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (MCCB as a incomer)
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
S/I/T/C of 18 watt,1200mm led tube light batten, surface mounted power coated housing made of exttuded aluminium profiles , suitable for operating voltage 100-270volt A.C, lumion output not less than 100Lum/watt,IP-20 protection,power factor > 0.95,6500K including chain,hook etc as required. Make Havells / Philips / Wipro
Supplying/installation/Testing and commissioning of 40Watt Post-top (Landscape Light-Clear PC Diffuser) LED luminaire with energy efficient electronic driver with following features:- Suitable for operating voltage and frequency: 100-270 Va.c, 50-60 Hz.; wattage not more than 40 Watts;Output lumens not less than 100 lm/watt; CCT 6500K; Nominal surge protection 2.5 kV;Power factor not less than 0.95; Minimum IP protection 65 etc including S/I/T/C of suitable G.I Pipe for installation of light etc as required. Make Havells / Philips / Wipro
S/I/T/C of 80wat/75watt LED high bay fixture at 8.0 Mtr height equiped with pressure die cast aluminium houising,power coated with weather proof gasket ensuring IP66,heat esistant with PC/PMMA highbay lences toughened glass suitable for surface /suspended / ceiling mounting arrangment and excellent heat dissipation for long life, inbuilt surge protection protection 4kV,power factor > 0.95 toughened glass with silicon gasket for IP66 protection. Suitable for operation 230 volt,50Hz and output lumens not less than 100lm/watt on existing angle / bracket i/c connections etc as required. Make Havells / Philips / Wipro
S/I/T/C of 1200 mm size sweep, BEE 5 star rated ceiling fan with Brush less Direct Current (BLDC) motor, class of insulation : b, 3 nos blades, 30cm long down rod, 2 no canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service value (CMM/W) minimum 6.85 Air delivery minimum 215 CMM, 350 RPM (tolarance as per IS : 374-2019), THD less than 10%,remote or electronic regulator unit speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 volt,50 Hz single phase AC supply system, earthing etc complete as required. Make havells/Atomberg/Orient/Crompton.
S/I/T/C of 10"(250mm) size,copper wound, ventiling fresh air fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required. make Crompton / havells / Bajaj
S/I/T/C of 24"(600mm) size,900rpm,copper wound, heavy duty metalic Exhaust Fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton / GE / havells
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 160A,25kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in cubicle panel board suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system fabricated CRCA sheet steel of 2mm thick including cleaning & finishing complete with powder coating in approved shade including drilling holes in cubicle panel, making connections, etc. as required.
Making Trenchless under the road (without cutting road) with mechanical bokies etc for 100mm dia G.I pipe/HDPVC pipe including dressing/remming including protective covering and refilling the trench etc as required.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying in position cement oncrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost).
Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 185 sq.mm)
Supplying and Laying of one number additional PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 95 sq. mm and upto 185 sq. mm (3.5C x 95 sq.mm)
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm (3.5C x 35 sq.mm)
Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 185 sq.mm)
Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle) (3.5C x 35 Sq.mm)
Supplying,Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 185 sq.mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 35 sq. mm (32mm)
3½ X 95 sq. mm (45mm)
3½ X 185 sq. mm (57mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
100 mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying, Installation, Testing & Commissioning i/c making solid foundation of brick,cement concrete (0.50Mtr above the ground level) of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.
INCOMER 1 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS TPN aluminium bus bars of minimum of 500 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS 2 Nos. 250 Amps. FP MCCB of 36 KA with inbuilt protection.
1 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
SUPER MOTOR WINDING & REFRIGERATION WORK
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .