dc power supply Dc Power Supply ( 25 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values FUNCTIONAL Maximum Power (Watt) 120 watts * DC Current Output Rating (Ampere) 0 to 4 * DC Voltage Output Rating (Volt) 0 to 30 * Load Regulation (Voltage) ± (% of output + offset) less than 0.01 +2 (milli volt) * Load Regulation (Current) ± (% of output + offset) less than 0.05 + 1.5 mA * Line Regulation (Voltage) ± (% of output + offset) less than 0.01 + 1 mV * Line Regulation (Current) ± (% of output + offset) less than 0.05 + 0.1 mA * Over Voltage Protection Accuracy +- 0.5 + 0.5 V * Over Voltage Protection Response Time (milli less than 10 milli second * 1/3 sec) Ripple and Noise Voltage (20 Hz to 20 MHz) less than 1 mVrms less than 4 mVpp * . Ripple and Noise Current (20 Hz to 20 MHz) less than 4 milli amps rms * Readback Voltage Accuracy 0.05 + 10 mV * Readback Current Accuracy 0.15 + 5 mA * Read back Voltage Resolution (mV) 1 * Readback Current Resolution (mA) 0.1 * CONSTRUCTIONAL PC Interface USB/GPIB/RS232/LXI * Weight (gms) less than 12 kg * Warranty (Year) 1 1
2 CERTIFICATIONS Operating Temperature (Degree C) 50 * Gperating Humidity (RH) (%) 0 * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification including environmental tests as under : (a) Dry Heat : For 16 hrs. at a temp. of 55 degree C in accordance with IS:900 0/part-3/section-5/1977 (reaffirmed in 2007). (b) Cold Test : For 4 hrs. at a temp. of -20 degree C in accordance with IS:9000/part-2/sec tion-4/1977 (reaffirmed in 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles of 24 h each at a temp. of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 (reaffirmed in 2007). After environmental conditioning sequence Yes * 2/3 as above and a recovery period of two hours
the instrument shall be checked for complete functional parameters
which should be with in limits.(Test reports are to be furnished when demanded by buyer) Test Report No. RLLPC/Test/SGPX887 * Test Report Date 3/2/2018 * Name and address of the Lab Shreeg LED Raipur Chhattisgarh * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Shukla 492001
O/o Executive Engineer
(E&M) Public Works Department Sirpur Bhawan Parisar
Raipur. (C.G.) 25 15
503031
GEM/2018/B/71184
dc power supply
15 days
Chhattisgarh; Raipur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| dc power supply Dc Power Supply ( 25 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values FUNCTIONAL Maximum Power (Watt) 120 watts * DC Current Output Rating (Ampere) 0 to 4 * DC Voltage Output Rating (Volt) 0 to 30 * Load Regulation (Voltage) ± (% of output + offset) less than 0.01 +2 (milli volt) * Load Regulation (Current) ± (% of output + offset) less than 0.05 + 1.5 mA * Line Regulation (Voltage) ± (% of output + offset) less than 0.01 + 1 mV * Line Regulation (Current) ± (% of output + offset) less than 0.05 + 0.1 mA * Over Voltage Protection Accuracy +- 0.5 + 0.5 V * Over Voltage Protection Response Time (milli less than 10 milli second * 1/3 sec) Ripple and Noise Voltage (20 Hz to 20 MHz) less than 1 mVrms less than 4 mVpp * . Ripple and Noise Current (20 Hz to 20 MHz) less than 4 milli amps rms * Readback Voltage Accuracy 0.05 + 10 mV * Readback Current Accuracy 0.15 + 5 mA * Read back Voltage Resolution (mV) 1 * Readback Current Resolution (mA) 0.1 * CONSTRUCTIONAL PC Interface USB/GPIB/RS232/LXI * Weight (gms) less than 12 kg * Warranty (Year) 1 1 | - | - | - |
| 2 CERTIFICATIONS Operating Temperature (Degree C) 50 * Gperating Humidity (RH) (%) 0 * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification including environmental tests as under : (a) Dry Heat : For 16 hrs. at a temp. of 55 degree C in accordance with IS:900 0/part-3/section-5/1977 (reaffirmed in 2007). (b) Cold Test : For 4 hrs. at a temp. of -20 degree C in accordance with IS:9000/part-2/sec tion-4/1977 (reaffirmed in 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles of 24 h each at a temp. of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 (reaffirmed in 2007). After environmental conditioning sequence Yes * 2/3 as above and a recovery period of two hours | - | - | - |
| the instrument shall be checked for complete functional parameters | - | - | - |
| which should be with in limits.(Test reports are to be furnished when demanded by buyer) Test Report No. RLLPC/Test/SGPX887 * Test Report Date 3/2/2018 * Name and address of the Lab Shreeg LED Raipur Chhattisgarh * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mukesh Shukla 492001 | - | - | - |
| O/o Executive Engineer | - | - | - |
| (E&M) Public Works Department Sirpur Bhawan Parisar | - | - | - |
| Raipur. (C.G.) 25 15 | - | - | - |
Exempted
25 Aug 2018
21 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_503031.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .