| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹13.0 L
EMD Value
₹14,000
Closing Date
12 Mar 2026, 3:00 pmClosed
Project Director
Project Director DRDA-Ranipet
Construction of DRCPs Building at Collectorate Campus, Additional Items in Ranipet District under District Panchayat General Fund scheme
2026_RDTN_671643_1
A11/6103/2024
Open Tender
Civil Works
Item Rate
90 days
DRDA-Ranipet
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹14,000
12 Mar 2026
6 Mar 2026
12 Mar 2026
6 Mar 2026
12 Mar 2026
6 Mar 2026
DRCP Building
Construction of DRCPs Building at Collectorate Campus, Additional Items in Ranipet District under District Panchayat General Fund scheme in Ranipet District.
Manufacturing,supplying and fixing of stainless steel hand rails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete.
Temple Pattern Ornamental Doors with high quality Burma Teakwood with 2” minimum to 7” maximum thick ornamental frames, 2” thick to 5” thick Kamala (Flower Planks), Creeper, Birds, Animal Figures, Sculptures, etc. Backside 1” thick to 3” plank incuding necessary carving, shaping, wastage, etc., as per approved plan and design. Teak wood Scantings over 2M and below 3M
Weathering Course Concrete using best quality broken brick jellyof 20 mm uniform guage in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jaggery water etc. complete complying with standard specifications and as directed.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Electrification
Wiring with 2 x 1.5 sq.m (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light point/fan point(for electronic regulator) - S.D.No: 21
Wiring with 2 x 1.5 sq.m (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with 150 x 100 x 113 TW switch box for 5A 3pin non inter locking CS plug with painting of suitable colour with continuos earth wire connection of 14 SWG TC wire for open PVC plug - S.D.No: 36
Supply and Fixing of CFL bulb 11w including cost and conveyance of all materials and labour charges etc complete. SD 80
Supply and fixing of 1200mm (48") AC ceiling fan with stepped electronic 300 W regulator with 1 meter down rod on the existing clamp. - S.D.no: 106
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting - S.D.No: 88
Supply and fixing of single box type 4'40 W Twins Street light flu fitting complete with copper choke and condensor with 32mm GI pipe (class B) with 1 no 32mm GI bendcomplete on existing post wall with 16Amps aerial fuse unit on MS plate with PVC unsheathed copper leads MS clamps and aluminium painting with flu tubes - S.D.No: 95
Supply and Fixing of CFL bulb 40w including cost and conveyance of all materials and labour charges etc complete. For Bulk head fitting SD 83
Supply and Fixing of 6 way SPDB of 16 Amps per way with 16 Amps DPIC switch of 500W with F and N (Front handle on suitable angle and Frame work with Box MS cable entry with Earth connection only.. SD 154
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End (SD 509)
Supply and fixing of 63A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD 632)
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with earth connection only. (SD 618)
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32 A 4 P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End (SD 529)
Supply and fixing of brass cable gland for 3 1/2 X 35 Sqmm PVC armoured LT UG cable with earth connection. (SD 201)
EarthingaspertheISIspecificationwithanearthelectrodeof2.10metreClass'B'GIpipeofdianotlessthan40mmwithcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnelingarrangementswithnecessarymasonry work and with 38mm RCC cover slab for the brick masonry (SD 211)
Main Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, cluster LED type indicators, in the incoming feeders, complete with electrolytic grade aluminium bus bars, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. (LOCAL RATE)
Provision for Signages (Directional signages for ramp - 2,toilet - 3
GST Amount for providing service to Government contract works for the above construction works. { GST amount is the Total GST amount for total overall quoted amount above this row in column "BB" for all works in this package}
stage.html
html • 0.02 MB
finance_807138.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_807138.xls
BOQ • 0.24 MB
Technicalbid.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .