| Sl No | Description | Qty | Unit | Devraj Enterprises L1 | Raj Engineering Co. L2 |
|---|---|---|---|---|---|
| 1.00 | S/o Double flanged G.I pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with G.I flange on both ends having the slot for sub cable. Make: - Tata/Jindal | 55 | Nos. | 1,76,000 ₹2,07,680 Lowest | 1,78,750 ₹2,10,925 |
| 2.00 | Supply of MCCB 63 Amp, 4 Pole, Breaking capacity at 415 V: 35-36 KA, adjustable thermal setting (70- 100%) and fixed magnetic settings. Make: - Havells/C&S/DJB Approved. | 2 | Nos. | 3,300 ₹3,894 Lowest | 3,400 ₹4,012 |
| 3.00 | Providing & fixing of indicating lamps RYB along with complete wiring of above Electrical components and with suitable size copper conductor wire (6sq mm, 4 sq mm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. Job i/c Testing & commissioning of complete panel board on load as per site requirement. | 5 | Jobs. | 62,500 ₹73,750 Lowest | 65,000 ₹76,700 |
| 4.00 | Supply of fully automatic oil immersed Star Delta Starter upto 15 HP , 3 Phase 415 Volts, 50 HZ AC. Make:- Bentex/BCH/DJB Approved. | 2 | Nos. | 15,000 ₹17,700 Lowest | 15,400 ₹18,172 |
| 5.00 | S/o PVC insulated PVC sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (Each roll of 100 mtrs.) Make: - Grandlay/Havells/gloster/DJB approved | 4 | Rolls | 72,000 ₹84,960 Lowest | 74,800 ₹88,264 |
| 6.00 | S/o MS nut bolts off size as per requirement. | 25 | Kg. | 3,000 ₹3,540 Lowest | 3,250 ₹3,835 |
| 7.00 | S/o Rubber packing 50 mm dia. flange. | 55 | Nos. | 2,200 ₹2,596 Lowest | 2,530 ₹2,985.4 |
| 8.00 | Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nutsand boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nutsbolts and rubber packing etc. The job includeshiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required will be arranged by the firm as per site requirement. The other material required during execution will be provided by department. | 5 | Jobs. | 1,19,000 ₹1,40,420 Lowest | 1,22,500 ₹1,44,550 |
Tender Value
Refer Docs
EMD Value
₹10,800
Closing Date
5 Jan 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Improvement of water supply by replacement of damaged E/M equipments of various tube wells installed at Near JSC and Murga Market Badarpur under Badrpur Constituency AC-53.
2025_DJB_283549_22
NIT No. 21/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹10,800
Yes
12 Mar 2026
24 Dec 2025
5 Jan 2026
24 Dec 2025
5 Jan 2026
24 Dec 2025
S/o Double flanged G.I pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with G.I flange on both ends having the slot for sub cable. Make: - Tata/Jindal
Supply of MCCB 63 Amp, 4 Pole, Breaking capacity at 415 V: 35-36 KA, adjustable thermal setting (70- 100%) and fixed magnetic settings. Make: - Havells/C&S/DJB Approved.
Providing & fixing of indicating lamps RYB along with complete wiring of above Electrical components and with suitable size copper conductor wire (6sq mm, 4 sq mm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. Job i/c Testing & commissioning of complete panel board on load as per site requirement.
Supply of fully automatic oil immersed Star Delta Starter upto 15 HP , 3 Phase 415 Volts, 50 HZ AC. Make:- Bentex/BCH/DJB Approved.
S/o PVC insulated PVC sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (Each roll of 100 mtrs.) Make: - Grandlay/Havells/gloster/DJB approved
S/o MS nut bolts off size as per requirement.
S/o Rubber packing 50 mm dia. flange.
Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nutsand boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nutsbolts and rubber packing etc. The job includeshiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required will be arranged by the firm as per site requirement. The other material required during execution will be provided by department.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
BOQ_374918.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .