Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.5 CrRejected-Finance | ₹3.5 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹3.6 CrRejected-Finance | ₹3.6 Cr | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualify |
Tender Value
₹3.5 Cr
EMD Value
₹7.0 L
Closing Date
31 Dec 2025, 3:00 pmClosed
General Manager Zone-3 UPPCL Lucknow
Office of the General Manager Zone-3 UPPCL Lucknow
Construction of Morden Workshop and Training Room Option (B) at Govt ITI, Harraiya Distt. Basti.
2025_UPPRC_1101616_1
55/GM-3/UPPCL/2025-26 DATE-18.12.2025
Open Tender
Civil Works - Buildings
270 days
Basti
As per bid documents
2 documents required · 2 mandatory
₹17,700
₹7.0 L
20 Jan 2026
24 Dec 2025
31 Dec 2025
24 Dec 2025
31 Dec 2025
24 Dec 2025
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenchesor drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam clay or sand) including lift upto 1.5 m. lead upto 50m and dressing of sides and rammings of bottom and disposal of surplus exdavated earth as directed by the Engineer I/C within a lead of 30 m. (All kind of soil)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):
550 mm dia single reamed pile
Ground floor
Local Sand filling in plinth including supply of neccasary quantity of sand from the site of work 8km and including watering dessing etc. including cost of all materials labour and T&P etc . Required for proper completion of the work.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (3) Treatment of top surface of plinth filling 5 liters/sqm
With Chlorpriphos EC 20% with 1% concentration
Providing and laying Cement Concret 1:4:8 (1cement :4coarse sand :8 stone aggregate 40mm including supply of all material ,labour and t&p etc.required for completion of work.
Providing and laying in position machine battched and machine mixed design mix M- 25 grade cement concrete for RCC work using cement content as per approved design mix. Including pumping of concrete to site of laying but including the cost of centreing, shuttering, finishing and Excluding reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impaaining strenght and durability as per direction of Engineer - In - Charge
All works upto plinth level
Footing
column
Grade beam
Slab on floor
All works above plinth level upto floor V level
column
Lintle
Slab/Chhajja
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work. FE 500 TMT BARS
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying damp proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 12.5mm nominal size)
Providing and applying a coat of residual petroleum bitumen of grade of VG - 10 of approved quality using 1.7 kg per sqm. On DPC after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work with common burnt clay (non moduler) brick of class -150 in super structure above plith lvl upto floor v lvl. In all shape and size in 1:4 (1: cement 4: coarse and mortar in one brick wall (230mm Thick )
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Extra for providing and placing in position 5 Nos 10mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Size of Tile 600x600 mm
Providing and laying Homogeneous VINYL floor (armstrong) simpurity with diamond 10 coating . Thickness 2mm & 2 mtr. Wide thickness of wear layer would be 2mm & single layered. Operation complete as per direction of Engineer - In - Charge.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm. Including grouting the joints with white cement and matching pigments etc, complete.
Granite stone slab colour black, Cherry/Ruby red
Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge.
Granite work
12 mm thik plaster with 1:6(cement :Coarse sand )2.25 F.M. over brick work minimum thickness not to be less than 1 cm .including supply of all material labour and T&P etc.required for proper completion of the work.Add for extra labour &materials for plaster over rough face of one brick wall .outer wall
12 mm thik plaster with 1:6(cement :Coarse sand )2.25 F.M. over brick work minimum thickness not to be less than 1 cm .including supply of all material labour and T&P etc.required for proper completion of the work.Add for extra labour &materials for plaster over rough face of one brick wall .Inner wall
Engraving line in the plaster of the outer face wall vertically and horizontally to display the surface as s directed by the engineer -in-charges including labour and T&P etc. required for completion of work in the proportion recommended by the manufacture.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint(APEX) of required shade : New work (Two or more coat applied @ 1.25 ltr/10 sqm over and including priming coat of exterior primer applied @.75 LTR/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work.Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Painting with synthetic enamel paint or approved band and manufacture of required colour to give an even shade.
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
With float glass panes of 5.5 mm thicness
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing ISI marked S.S.. Tower bolt black finish, (Barrel type) with necessary screws etc. complete
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-incharge..
Providing and fixing tiled false ceiling of specified maerials of size 595x595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanised @120 grms/sqm, both side inclusive) consisting of maijn T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T"
12.5mm thick square edge PVC laminated Gypsum Tile of size 595x595mm made of Gypsum plastterboard, manufactured from natural gypsum as per IS 2095 part 1 and laminated with while 0.16mm thick fire etardand PVC film on the face side and 12 micron metalized polyester on the back side with all edges seated with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Cement concrete flooring 1:2:4 ( 1 Cement : 2 Coarse sand : 4 gradede stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete (25 mm thick)
Appron Drain (150x150 ) size with M-150 Class brick work in 1:3 cement and coarse sand mortar F.M.2.5 along appron including supply of all materials labour and t&Petc.required for proper completion of work.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
S/o Hand rail and balustarde modular systom passive ss-304 grade decorative railing system comprising of hand rail 50mm and 1.5 mm thick and 3 no .horizontal steel pipe of 19 mm dia and 1.5 mm thick of equal spacing with balustrade fo ss pipe of 38nn and 1.5mm thick @ 1200mm c/c of passivated ss304 rade and fix duly on the floor with spacially rivet expansion bolt and finish the surface food and covering with steel shoe ,with all visible stainless metal of 304 grade in satin finish hight of railing is 900 mm as per detailed speicification.
50 mm thick
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.
Group of two or more piles upto 50 tonne Safe capacity
Cost of Earth filling (dsr-2.25a)
DEMOLITION
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge DSR (15.2.1)
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
2 Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
Cost of Internal Sanitry and Water Supply Work
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and
Range of two urinal basins with 10litre white P.V.C. automatic flushing cistern.
Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth
Granite stone of approved shade
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:
Kitchen sink without drain board
510x1040 mm bowl depth 250 mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.
Flexible pipe
i) 32 mm dia
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 1500x450 mm
Providing and fixing toilet paper holder :
C.P. brass
Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Shoe (Plain)
75 mm Shoe
110 mm Shoe
Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall
20 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.
15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
25mm dia, nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
15mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
15mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
15 mm nominal bore
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
160/150 mm diameter pipe
Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :
(a) Inside size 900 x 800mm and 500mm deep including C.I. Cover frame.
(b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame.
(b) Size 1200 x 900mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Cost of External sewage and water supply pipe line system
SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE &WASTE SYSTEM - I
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design
150 mm diameter S.W. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
150 mm dia. R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
150x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix
(1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4
(1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
a) Inside size 90x80 cm & 500cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
EXTERNAL WATER SUPPLY SYSTEM -II
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
32 mm dia nominal bore
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design
With common burnt clay M-150.(non modular) bricks of class designation.
Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.
In all kind of soil upto 1.5m depth
In all kind of soil upto 1.5m to 3.0m. depth
In all kind of soil upto 3.0m to 4.5m. depth
Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size)
Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
Suspended floors, roofs, landings, balconies and access platform.
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand)
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
Providing and fixing C.I. tee at the inlet and outlet of septic tank.
Providing & fixing 75mm dia vent pipes.
Providing & fixing of 75mm dia cast iron terminal guard.
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
M.D. -2.5- Circular shape 450mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.
With F.P.S. bricks
Cost of Electrical Work
Point Wiring :
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for group controlled(looped) light point/fan point/exhaust fan point/call bell point(without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Submains :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Installation ,Testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLSH PVC insulated , copper conductor , single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (for A.C. Point/MCB Point)
Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
4 way (4 + 36), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door(VERTICAL)
12 way (4 + 36), Double door(VERTICAL)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
double pole
triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A,30KA,FPMCCB
Supply and fixing of 40 Amp. 4 pole MCB (10 KA) C Curve. CAT A
Supply and fixing of 63 Amp. 4 pole MCB (10 KA) C Curve. CAT A
ELCB/RCCB Switches :
Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4 way double pole
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 30 A "C"curve, TPMCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 63 A "C"curve, TPMCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Earthing Work :
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.
100 mm dia
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
L.T. Switch Panel Board :
Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.
The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type
Main LT Panel :
Incoming -
1250 AMP ACB EDO TYPE 2NO 56 KA
1250 AMP ACB EDO TYPE 1NO 56 KA (BUS COUPLER)
BUS BAR 2500 AMP 4 P
Outgoing -
630 Amp MCCB MDO 25 KA 400 KVAR ( CAPASTER BANK 2NO. )
63 Amp 4P MCB - 4 No. ( LIFT,PUMP,EXTERNAL LIGHT,BASEMENT DP )
200 Amp 4P MCCB - 35KA-6 No. ( VTPN DP)
Spare 63,Amp MCB,200 AMP MCCB without MCB - 2 No.
(Complete as per requirment directed by Project Manager.)
Lighting Fixtures (Lights/Fans) :
Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA)
Supply and fixing of 12 Watt to 15 Watt indoor surface mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA)
Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA
Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 10 watt suitable for upto 15 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA
Armoured Cables (Cable/Gland/Lug) :
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size
size 35 sq mm x 3.5 core
size 50 sq mm x 3.5 core
size 70 sq mm x 3.5 core
size 185 sq mm x 3.5 core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer-incharge. for cable
size 35 sq mm x 3.5 core
size 50 sq mm x 3.5 core
size 70 sq mm x 3.5 core
size 185 sq mm x 3.5 core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
size 35 sq mm x 3.5 core
size 50 sq mm x 3.5 core
size 70 sq mm x 3.5 core
size 185 sq mm x 3.5 core
Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules.
Non-Schedule Items
Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect.
Supply of400mm size Wall fan suitable for 230V, 50 Hz AC including modifying and connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC Conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
Supplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mm x 75mm)
FIRE FIGHTING
CO2 type fire existinguisher capacity : 4.5 k.g.
SIGNAGE
3mm acrylic backlit letters with 1.5inch raising (Letters Height:9inch)
Instalation charge
RAIN WATER HARVESTING WITH
RECHARGE PITS
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
In all kind of soil upto 1.5m depth
In all kind of soil upto 1.5m to 3.0m. depth
In all kind of soil upto 3.0m to 4.5m. depth
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.
Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: .
Cement mortar 1:4 (1 cement : 4 coarse sand)
Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources).
R.C.C. work in Slab
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
thermo-mechnically treated bars
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
With 20x20mm square bar
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
Drilling of 300mm dia bore hole manually.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
DESILTING CHAMBER
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
In all kind of soil upto 1.5m depth
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: .
Cement mortar 1:4 (1 cement : 4 coarse sand)
Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources).
R.C.C. work in Slab
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
thermo-mechnically treated bars
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
With 20x20mm square bar
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
M.D. -10- Circular shape 500mm internal diameter
DRAINAGE NETWORK
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
Pipes 80 mm to 300 mm diameter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
150 mm. dia.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5
Centering and shuttering including strutting, propping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform
CC ROAD
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width aswell as 10 sqm on plan) including disposal of excavated earth, leadupto 50m and lift upto 1.5m, disposed earth to be levelled and neatlyy
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).
Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation M-150
Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads/ pavements all complete as per directionof the Engineer-In-Charge.
12 MM thick plaster (1:3) with coarse sand
ADD COST FOR 1.5 Tr Split AC
Supply & installation of split direct expansion Air conditioners suitable for operation on A/C Supply single phase 50 HZ 230 Volts with hermetically sealed compressor with air cooled condenser ,motor capacitor and startrun capacitor .relay and over load protector internal unit ,with one indoor and one outdoor unit.The condenser unit will be placed outside the room on the terrace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube .(hIGH WALL CHORDED /CORDLESS ) SUITABLE CAPACITY 3 CORE SHEATHED /PVC COPPER CABLE AND A BATTERY OPERATED WIRELESS REMOTE.VOLTAS /HITACHI /SAMSUNG ETC.
Bee star rated :5 star ,EER3.4
CC CAMEARA
IP 4MPX Colour night vision cameras
Networking of cameras
Power on eathernet Full Gygabit switch
Gygabit switch 8+2
Cat-6 Wire Dlink
Network Video Recorder 64 Channel 2 hdd
Surveillance Harddrive 6/4 Tb
Wiring Charges
Wiring Clips/Clamps and all Accessories
Installation/commissionning of ip cameras
POE Box
U6 Networking Rack
Camera Housing
Cat-6 Connectors
43' Monitor for viewing
Internet setup router and Networking
GST Extra As per Applicable
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.55 MB
BID_DOC.pdf
Tender Documents • 13.63 MB
BOQ_2030593.xls
BOQ • 0.89 MB
Download all tender documents and submit your bid