Loading…
Loading…
Tender Value
₹67.5 L
EMD Value
₹1.4 L
Closing Date
6 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
15 conditions · 3 needing a document upload
For works costing more than Rs.50 Lakhs:The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; where V = Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB in GCC APRIL 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non submission of the above, the offer will be summarily rejected. (Ref : Advance Correction Slip No.1 dt:14/07/2022 to IRSGCC- 2022 ).
Option for Payment: An option is available that the Supplier/Contractor to take payment from Railways through Letter of Credit (LC) arrangement, having the estimated value of Rs.10 Lakhs and above. All the suppliers/contractors are requested to make use of this facility from Railways.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
"The Similar work is defined as, "Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HASSDAC) or Automatic signalling"
17 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit Earnest Money Deposit (EMD) & Tender Document Cost (TDC), in respect of e- tendering, should be accepted through net banking or payment gateway only. Fixed Deposit Receipt (FDR) will not be accepted as EMD for tenders invited on IREPS (e-tender portal). When submitted in physical form, the Tenderer shall upload scanned copies of financial instruments such as EMD, Tender form cost, mandatory credentials such as experience, turn over certificates and any other documents as applicable. All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded at the time of submission of bid S&T/SA failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We have read the various conditions to tender attached hereto and agree to abide by the said conditions
I/We also agree to keep this tender open for acceptance for a period of 60days from the date fixed for opening the same
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
I/We have read the various conditions attached/ referred to in this tender document, and agree to abide by the said conditions.
Deployment Of Qualified Engineers At Work Sites By The Contractor. The contractor shall also employ Qualified Graduate Engineer or Qualified Diploma Holder Engineer, based on value of contract, as may be prescribed by the Ministry of Railways through separate instructions from time to time.(As per RB ltr no.2012/CE-I/CT/O/20 dt:10.05.2013)
One qualified Graduate Engineer when the cost of the work is Rs. 200 lakhs and above.
One qualified Diploma holder Engineer when the cost of the work 9.1.1 to be executed is more than Rs.25 lakhs but less than Rs.200 lakhs.
In case the contractor fails to employ the technical staff as aforesaid, he shall be liable to pay a an amount of Rs.40,000/ (Rupees Forty thousand) for each month or part thereof for the 9.1.2 default incase of Graduate Engineer and Rs.25,000/- (Rupees Twenty five thousand) for each month or part thereof for the default in case of Diploma holder (Engineer)
In case of more than one L-1 bidders, tender may be awarded to tenderer having higher Bid Capacity. In case Bid Capacity is also the same, tenderer having done more value of similar work in last three previous financial years and the current financial year upto the date of opening of the tender, may be selected for the award. Instructions with respect to Bid Capacity will follow.
All the contracts on works/goods/services will be subject to the new GST act as applicable from time to time. Contractors have to register themselves with GST authorities and to furnish the GST registration number in order to process the bills from 01.7.2017
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/WE also hereby agree to abide by the INDIAN RAILWAY GENERAL CONDITIONS OF CONTRACT- APRIL 2022, with all correction slips up to date and to carry out the works accordingly.
In the e-tendering process, it is mandatory that every tenderer/contractor/firm registered with WWW.IREPS.GOV.IN to submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number
Salem Division: Augmentation of Good shed lines (Rd.6&7) to full length with CC unloading pavement between Rd.6&7 for about 300m at PLMD station.
SA-SG-120-I-OT-35-2025
SA-SG-120-I-OT-35-2025
Open
Works - General
12 Months
Salem, Tamil Nadu
₹0
₹1.4 L
6 Apr 2026
13 Mar 2026
23 Mar 2026
120 items across 2 schedules · ₹61,94,425.82 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Testing and commissioning the RRI/PI signalling i n s t a l l a t i o n s j o i n t l y w i t h the Railway representative a t site a t the stations/ L C gates covered under various schedules of the Contract and ensuring that all t h e signalling gears are installed and adjusted as per the existing rules. The work also involves s u p p l y o f required number of bound registers w i t h g o o d quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, r e l a y r o o m k e y e n t r i e s , block instrument k e y , e a r t h resistance e t c . , and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of stations (more than 5 roads) | Station | 1.00 | 67,941.71 | 67,941.71 |
| 2 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as- made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 150.00 | 382.12 | 57,318 |
| 3 | Wiring of Relay Inputs to Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 50.00 | 285.86 | 14,293 |
| 4 | Wiring of Analog Voltages from IPS Room to Datalogger. N e c e s s a r y W a g o s r e q u i r e d is included as per schedule | Numbers | 20.00 | 285.86 | 5,717.2 |
| 5 | Supply o f earth electrodes (G I) a s p e r Drg no SG/CN/02/13 | Numbers | 15.00 | 1,618.75 | 24,281.25 |
| 6 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 15.00 | 1,707.55 | 25,613.25 |
| 7 | "Full Location: Supply and fixing of GI Flat of size 1050x25x3mm a s given i n enclosed drawing to connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 10.00 | 1,370.66 | 13,706.6 |
| 8 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm as given in enclosed drawing to connect all cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 6.00 | 846.75 | 5,080.5 |
| 9 | Supply o f L o w maintenance secondary cells of t h e f o l l o w i n g c a p a c i t i e s w i t h necessary i n s p e c t i o n a s p e r specificatio n/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 45.00 | 3,379.2 | 1,52,064 |
| 10 | Supply of track feed battery charger IRS:S 89- 2013 | Numbers | 15.00 | 4,375.25 | 65,628.75 |
| 11 | Supply of 'B type choke IRS:S 65-83 | Numbers | 30.00 | 2,855.6 | 85,668 |
| 12 | Supply of Modular Terminal Block of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s per R D S O Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 200.00 | 194.95 | 38,990 |
| 13 | " S u p p l y o f F U S E terminals b l o c k w i t h LED indication upto 2.5sq.mm screw type 1 IN 1 OUT ( Suitable 400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest." | Numbers | 50.00 | 219.87 | 10,993.5 |
| 14 | Supply of DIN channel for the terminal | Metre | 25.00 | 344.87 | 8,621.75 |
| 15 | Supply of END plates for modular terminal block | Numbers | 10.00 | 36.86 | 368.6 |
| 16 | Supply of END clamp for modular terminal block | Numbers | 10.00 | 26.35 | 263.5 |
| 17 | Supply of Shorting Link insulated Grey in color | Numbers | 10.00 | 21.2 | 212 |
| 18 | Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) | Numbers | 50.00 | 61.74 | 3,087 |
| 19 | Fixing of Modular terminal block/fuse block along with accessories with provision of fixing holes on hylam sheet/side angles of Location B o x and fi x i n g b y Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 250.00 | 28.97 | 7,242.5 |
| 20 | S u p p l y a n d provision o f n o r m a l j o i n t using T h e r m o s h r i n k jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e i n s t r u c t i o n o f Railway representative at site. | Numbers | 8.00 | 4,628.91 | 37,031.28 |
| 21 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.) as per drawing enclosed | Numbers | 50.00 | 262.65 | 13,132.5 |
| 22 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & Laying in position c e m e n t c o n c r e t e o f specified proportion i n c l u d i n g c o s t o f cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and a l l other misc materials required f o r the work should be supplied by Contractor). | cum | 10.00 | 9,361.46 | 93,614.6 |
| 23 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 2000.00 | 64.1 | 1,28,200 |
| 24 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 100.00 | 314.41 | 31,441 |
| 25 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by r a m m i n g a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / R C C p i p e s . During excavation o f trench, i t has t o b e ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e from t h e b o t t o m o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 180.00 | 385.45 | 69,381 |
| 26 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 30.00 | 501.03 | 15,030.9 |
| 27 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 120.00 | 208.54 | 25,024.8 |
| 28 | Provision o f G I pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out a s per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Metre | 60.00 | 182.87 | 10,972.2 |
| 29 | Laying o f signaling/power/ telecommunication cables a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 6500.00 | 18.18 | 1,18,170 |
| 30 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." | Metre | 2000.00 | 15.4 | 30,800 |
| 31 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. T h e cable markers s h a l l b e provided a t an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also a t every track/road crossing." | Numbers | 50.00 | 123.35 | 6,167.5 |
| 32 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling t h e underground cables and placing closely one layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 5.00 | 949.05 | 4,745.25 |
| 33 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 t o 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe o r any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 30.00 | 1,351.45 | 40,543.5 |
| 34 | Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 2.00 | 10,030 | 20,060 |
| 35 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 8.00 | 8,850 | 70,800 |
| 36 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 8.00 | 9,233.5 | 73,868 |
| 37 | Supply o f subsidiary Signal Aspect - Route LED a s per RDSO Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 30.00 | 5,703.33 | 1,71,099.9 |
| 38 | Supply o f subsidiary Signal Aspect - Shunt LED a s p e r R DSO Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 25.00 | 5,740.7 | 1,43,517.5 |
| 39 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 2.00 | 5,841 | 11,682 |
| 40 | Supply o f Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 6.00 | 4,737.7 | 28,426.2 |
| 41 | Supply o f surface base t o suit C L S Signal pole 140mm d i a w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 6,814.5 | 54,516 |
| 42 | Supply of ladder with platform and shoes to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. a)Supply o f l a d d e r w i t h p l a t f o r m ( 4 . 6 m ) for CLS(Galvanised) | Numbers | 2.00 | 5,698 | 11,396 |
| 43 | Supply of ladder with platform and shoes to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. b)Supply o f l a d d e r w i t h p l a t f o r m ( 3 . 6 m ) for CLS(Galvanised) | Numbers | 6.00 | 5,494.5 | 32,967 |
| 44 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 5,087.5 | 40,700 |
| 45 | Supply o f Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 4.00 | 7,463.5 | 29,854 |
| 46 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting s o c k e t , w i t h n e c e s s a r y inspectio n a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 2.00 | 16,874 | 33,748 |
| 47 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting s o c k e t , w i t h n e c e s s a r y inspectio n a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 6.00 | 14,278 | 85,668 |
| 48 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers | 1.00 | 22,260.7 | 22,260.7 |
| 49 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. e) Supply of Junction type route indicator - 5 way | Numbers | 1.00 | 29,529.5 | 29,529.5 |
| 50 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 2.00 | 3,569.5 | 7,139 |
| 51 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 2.00 | 2,645.5 | 5,291 |
| 52 | Supply of cable termination box (FRP type) with n e c e s s a r y i n s p e c t i o n a s per specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 7,788 | 62,304 |
| 53 | Supply o f KLCR relays 24V, A C I (Supply of Key Lock Checking Relay (KLCR) with one number K- 50 neutral Relay to work on 24V DC n o n AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 4.00 | 10,722.72 | 42,890.88 |
| 54 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 30.00 | 5,901.5 | 1,77,045 |
| 55 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 2.00 | 4,945.51 | 9,891.02 |
| 56 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ LC control circuit (up to 8 relays/plug in type) | Set | 6.00 | 8,786.26 | 52,717.56 |
| 57 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 6.00 | 11,355.02 | 68,130.12 |
| 58 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ LC control circuit (up to 20 relays/Plug in type) | Set | 4.00 | 13,597.41 | 54,389.64 |
| 59 | Supply of Electric key transmitter - rotary type of required w ard N os. w ith keys, with necessary inspection as per specification/ drawing/ | Numbers | 2.00 | 6,344.8 | 12,689.6 |
| 60 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 1.00 | 15,009.6 | 15,009.6 |
| 61 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 100.00 | 167.99 | 16,799 |
| 62 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g P B T f u s e b l o c k i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 20.00 | 201.27 | 4,025.4 |
| 63 | Fi x i n g o f additional p l u g b o a r d s , 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided w h e r e v e r required. Alterations t o Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining c l i p s a n d 5 0 way terminal boards is not covered in this schedule). [Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors a n d condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made o f PVC, paint, v a r n i s h a n d a l l other miscellaneousmaterials required f o r t h e work shall be supplied by the Contractor ] | Per Relay | 50.00 | 726.5 | 36,325 |
| 64 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w o r k includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 125.00 | 695.67 | 86,958.75 |
| 65 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6 m o f pipe as per Technical specification | Metre | 150.00 | 365.19 | 54,778.5 |
| 66 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 120.00 | 1,119.16 | 1,34,299.2 |
| 67 | Supply and laying o f P V C Warning Tape colour Orange, width o f 250mm (10") by printing with black letters 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 2000.00 | 46.15 | 92,300 |
| 68 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary i n s p e c t i o n a s p e r specificatio n/ drawing/ description enclosed in this document. | Numbers | 40.00 | 1,622.5 | 64,900 |
| 69 | Supply of Track Feed Resistance | Numbers | 15.00 | 287.77 | 4,316.55 |
| 70 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 1000.00 | 61.44 | 61,440 |
| 71 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 50.00 | 93.02 | 4,651 |
| 72 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 50.00 | 103.84 | 5,192 |
| 73 | Supply of E-Type Locks | Numbers | 5.00 | 1,234.88 | 6,174.4 |
| 74 | Supply and wiring of LEDs with resistance and fixing on the cable termination rack for indicating "FUSE BLOWN OUT" for each circuit. The LEDs and resistances shall be fixed on a phynolic sheet 50mm width and 3mm thick. The phynolic sheet shall be fixed by the side of the corresponding Fuse Blocks. Separate switch shall be provided for each circuit.[LEDs 10mm, holders, resistance, switch, phynolic sheet, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 10.00 | 60.68 | 606.8 |
| 75 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 50.00 | 37.74 | 1,887 |
| 76 | Excavation o f pit, erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires f o r Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e coat of red- oxide and two coats of aluminium paints. | Numbers | 8.00 | 5,029.69 | 40,237.52 |
| 77 | Installation of combined type point machine-IRS t y p e a n d connecting a l l ground connections including wiring and termination in point machine a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm c o p p e r w i r e and p a i n t i n g . This work i n c l u d e s p r o v i s i o n of insulation to stretcher bars, throw b a r l u g and "D" bracket w h e r e v e r r e q u ir e d , c u t t i n g of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Numbers | 8.00 | 16,383.88 | 1,31,071.04 |
| 78 | Fi l l i n g e a r t h a r o u n d l o c a t i o n boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming.The e a r t h s h a l l b e t a k e n from Railway premises as instructed by Railway representative at site. | cum | 5.00 | 231.3 | 1,156.5 |
| 79 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection o f colour light signals up to 4 aspects.[Foundation b o l t s , c e m e n t , M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 8.00 | 9,213.28 | 73,706.24 |
| 80 | "Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED / filament b u l b s ) with lenses, t r i p l e p o l e l a m p holder, filament switching u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting o f l a d d e r s h o e , fi x i n g o f number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring o f signal unit with P V C wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole i n the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints PVC/Nylon sleeves, enameled n u m b e r plates. enameled marker boards, E W S locks, a n d all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 8.00 | 8,287.08 | 66,296.64 |
| 81 | "Excavation o f p i t a n d c a s t i n g concrete foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone j e l l y o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 4.00 | 4,645.17 | 18,580.68 |
| 82 | "Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/ l e n s e s , b u l b s w i t h holders (whichever is applicable), fixing of lens guards, number plate, termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two c o a t s o f Aluminium/ enamel paint. (Supply o f Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule).[Wire PVC 3/0.75mm c o p p e r , lens guards, E W S locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 4.00 | 3,170.44 | 12,681.76 |
| 83 | Fixing of Offset brackets using 'U' bolts and nuts, erection of Post type shunt Signals, termination o f t a i l c a b l e s a n d w i r i n g using wire PVC 3/0.75mm copper, provision of EWS l o c k and painting of one coat of red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S post a n d provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 8.00 | 2,306.03 | 18,448.24 |
| 84 | Fixing of junction type route indicators - 1 way to 6 ways - complete/ fixing of additional limb to the existing route indicators, termination o f tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f j u n c t i o n t y p e Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e mesh, P V C / N y l o n sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing and wiring o f direction type route indicator - 3 way | Numbers | 1.00 | 2,679.26 | 2,679.26 |
| 85 | Fixing of junction type route indicators - 1 way to 6 ways - complete/ fixing of additional limb to the existing route indicators, termination o f tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f j u n c t i o n t y p e Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e mesh, P V C / N y l o n sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. e)Fixing and wiring of direction type route indicator - 5 way | Numbers | 1.00 | 4,582.91 | 4,582.91 |
| 86 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 4.00 | 8,914.5 | 35,658 |
| 87 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 6.00 | 7,145.44 | 42,872.64 |
| 88 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 5.00 | 4,234.65 | 21,173.25 |
| 89 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 5.00 | 3,850.31 | 19,251.55 |
| 90 | Excavation o f pit, casting concrete foundation and erection o f apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for t h e bac k door, fixing o f o n e h a r d w o o d shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation b o l t s & n u t s , ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 12.00 | 11,333.1 | 1,35,997.2 |
| 91 | "Excavation o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & n u t s a n d a l l o t h e r miscellaneous materials required f o r t h e work shall b e supplied by the Contractor]""" | Numbers | 8.00 | 8,787.04 | 70,296.32 |
| 92 | Termination o f n e w main/tail c a b l e s o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r a p p r o v e d circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry o f n e w cables in the apparatus cases w ith masonry brick work and sealing the bottom o f the apparatus cases/ cable termination racks w ith cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied b y the contractor]. (Per Unit = Per Terminal block) | Per Unit | 250.00 | 73.59 | 18,397.5 |
| 93 | Termination o f main, tail, Signaling and power cables a n d internal w i r i n g on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 1250.00 | 172.14 | 2,15,175 |
| 94 | Termination o f main, tail, Signaling and power cables a n d internal w i r i n g on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination o n PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 100.00 | 209.93 | 20,993 |
| 95 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 100.00 | 151.09 | 15,109 |
| 96 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. b)Termination of cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 10.00 | 188.86 | 1,888.6 |
| 97 | Installation of charged secondary cells of the f o l l o w i n g c a p a c i t i e s i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit | 45.00 | 491.59 | 22,121.55 |
| 98 | Provision of signaling arrangement during Non- Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station | 1.00 | 33,631.06 | 33,631.06 |
| 99 | Provision o f PA system a n d Magneto telephone communication a t stations/ tents as p e r the instructions o f Railway representative a t site. The PA system and magneto telephones will be returned to the contractor after t h e completion of NI working. Signalling cables available may be used for the communication.(Hiring of PA system equipments and magneto telephones shall be done by the Contractor)[All other miscellaneous materials required for the work shall be supplied by the Contractor]. (Per Unit= Per set per day) | Per Unit | 3.00 | 1,637.25 | 4,911.75 |
| 100 | Hiring of tarpaulin tents and providing the same at places as instructed by Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided w ith a t a b l e , c h a i r , t u b e lights and p e d e s t a l fan. Drinking water i n cans.The tents shall be fixed firmly t o withstand rain, strong wind etc.(Per Unit = Per tent per day) | Per Unit | 3.00 | 1,328.3 | 3,984.9 |
| 101 | Fixing of EKT instrument with (or) without crank handle o r o n s u i t a b l e fi x t u r e s at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire P V C 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting.(Supply of electric key transmitter and crank handles is not covered i n this schedule). [wire P V C 16/0.2mm copper, w i r e wound resistance, d e c o l u m covered terminal box with locking facility by using 25mm thick teakwood, bolts a n d n u t s , paints, push switches, padlocks a n d other miscellaneous materials required for this work shall be supplied by the contractor]. | Numbers | 2.00 | 5,445.94 | 10,891.88 |
| 102 | Provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides | Numbers | 5.00 | 697.45 | 3,487.25 |
| 103 | Releasing of existing Route Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 2.00 | 1,541.51 | 3,083.02 |
| 104 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing the s h e l f p l a n k s , Terminal blocks, F u s e Blocks, Terminal Boards, Relays o f a l l t y p e s EKTs, Secondary Cells, power equipments, ' E ' type l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The r e l e a s e d m a t e r i a l s s h a l l be accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers | 20.00 | 3,006.71 | 60,134.2 |
| 105 | Breaking of concrete and releasing the existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal B o a r d s , c u t rails, pipes, e t c . , c l o s i n g the resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 9.00 | 2,004.94 | 18,044.46 |
| 106 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Ro u t e Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing the resultant pit and resurfacing it by ramming and levelling. | Numbers | 9.00 | 3,083.03 | 27,747.27 |
| 107 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections a n d o t h e r accessories available complete without a n y damage t o the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 9.00 | 2,698.69 | 24,288.21 |
| 108 | "Releasing of existing ground type shunt signals along with surface base, signal post etc carefully without a n y damage, accounting a n d stacking them neatly at a place as instructed b y Railway representative a t site. T h e w ork also includes breaking a n d removal o f concrete foundation and refilling of the resultant pit by ramming and levelling." | Numbers | 5.00 | 2,196.41 | 10,982.05 |
| 109 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 30.00 | 159.29 | 4,778.7 |
| 110 | Provision of one skilled and 2 unskilled staff round the clock to attend the teething trouble of the installation along with SSE/JE after the i n s t a l l a t i o n h a s b e e n b r o u g h t into commissioning. T h e w o r k i n c l u d e s routine maintenance, failure restoration a s p e r the direction of the SSE/JE | Month | 1.00 | 73,903.01 | 73,903.01 |
| 111 | Providing the services of Computer oriented technical manpower t o carryout w o r k s like D r a w i n g , computation, w r i t e u p e t c . , using computer, using software like AUTOCAD, MS O ffi c e e t c . , f o r 0 8 . 0 0 h r s i n a d a y w i t h all expenses of transportation, accommodation, f o o d , consumables e t c . , w i t h a l l ascents, descents, taxes, octroi, cess, fees, duties, duties w i t h contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall b e c o n v e r g e n t w i t h computer working knowledge in above software. | Man- Days | 10.00 | 913.28 | 9,132.8 |
| 112 | Protection adjustments a n d re-instating of S&T gears by deputation of Helpers/Unskilled Labour f o r executing additional S & T portio n o f the works. The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 60.00 | 847.59 | 50,855.4 |
| 113 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work c a n involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting b r i c k w o r k , wiring alterations, cable jointing etc a s per instruction of Railway representatives at size. | Man- Days | 30.00 | 1,073.45 | 32,203.5 |
| 114 | Transportation of Signalling materials by road as per the instructions of Railway representative at s i t e . T h e w o r k also includes l o a d i n g and unloading o f the materials a)Transportation of Signalling materials upto 100kms | MT-Km | 1000.00 | 22.75 | 22,750 |
| 115 | Transportation of Signalling materials more than 100km | MT-Km | 500.00 | 13.91 | 6,955 |
| 116 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction of Railway representative at site. | Hour | 5.00 | 1,202.5 | 6,012.5 |
| Schedule total | ₹45,49,740.82 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPODETAILS_compressed1.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
PLMDOT35TenderDocument1.pdf Tender Booklet OT 35
ATTACHMENT
I_CT_GCC-
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
GCCCorrectionslip1to10.pdf
ATTACHMENT
PLMDOT35TenderDocument1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .