Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.7 L+₹1.5 L (8.93%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹22.9 L+₹6.7 L (41.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹24.3 L+₹8.0 L (49.3%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹25.3 L+₹9.0 L (55.7%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Jun 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR TO LEAKAGE/SEEPAGE, CI, GI PIPES FITTINGS, TILING AND OTHER MISC B/R WORKS IN MD OFFICERS ACCN AT SHANKAR VIHAR UNDER AGE B/R-II OF GE (SOUTH) DELHI CANTT-10
2023_MES_598372_1
GE/DS-21/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹90,000
Yes
7 Jul 2023
25 May 2023
24 Jun 2023
25 May 2023
22 Jun 2023
8 Jun 2023
Amount
Taking down cement or cement lime plaster, any description, on brick or stone walls/ concrete surface, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and fair using water proofing compound by weight as per manufacturer's instructions complete all as specified and as directed. Note : WPC will be measured and paid separately under respective item.
M&L for 15 mm thick cement plaster in patches n.exc 3 Sqm on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and fair using water proofing compound by weight as per manufacturer's instructions complete all as specified and as directed. Note : WPC will be measured and paid separately under respective item.
M&L for 15 mm thick rendering in CM 1:6 of brick/ concrete surfaces, finished fair, even and smooth without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling and finished fair even and smooth without using extra cement, complete all as specified and as directed.
M&L for Preparing new plastered or unplastered surfaces of wall/ceiling and applying exterior emulsion paint white or tinted specified as per manufacturer instruction complete all as specified and as directed.
M&L for preparing of new plastered or unplastered surfaces of ceiling and applying three coats of White wash complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over including one coat of birla white putty on whole surface complete all as specified and as directed.
Supply only liquid water Proofing Compound confirming to relevent IS complete all as specified and as directed.
Dismentling floors, hearth or wall tiling including cement morter bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Vitrified Ceramic tiles, light shade, 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and as directed.
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 Sqm as in floors etc. laid over and including 15mm thick screed bed in CM (1:6) , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and as directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles complete all as specified and as directed.
M&L Non skid coloured ceramic tiles 7to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 sqm, as in floors laid over and including 15 mm thick cement screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles complete all as specified and as directed.
M&L for Glazed Ceramic coloured tiles in vertical surface 450X300X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat in cement mortar (1:4) complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles of 300x200x7mm thick, on vertical surfaces over and including 10mm thick cement plaster in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing’s or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and as directed.
M&L for cutting holes into or through cement concrete slabs, chajjas etc. superficial area n. exc. 100 sq cm reinforced or otherwise incl arrangement for cutting through reinforcement if required complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections including removal complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections including removal complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections including removal complete all as specified and as directed.
S&F in repairs 3 layers 32 mm bore PP-R (Polyproplylene Random copolymer) concealed pipes SDR 7.4 (PN 16) UV stabilizer and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polyproplylene random fittings (includig tank nipple) for water tank over flow pipe in replacement of 20mm bore GI pipe fixed to wall ceiling or in floor etc. complete all as specified and as directed.
S&F in repairs 3 layers 40 mm bore PP-R (Polyproplylene Random copolymer) concealed pipes SDR 7.4 (PN 16) UV stabilizer and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polyproplylene random fittings (includig tank nipple) for water tank over flow pipe in replacement of 20mm bore GI pipe fixed to wall ceiling or in floor etc. complete all as specified and as directed.
S&F 15mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors complete all as specified and as directed.
S&F 20mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors complete all as specified and as directed.
S&F 25mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors complete all as specified and as directed.
Fixing only 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Fixing only 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Fixing only 25 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in repairs plastic WC seat cover white/ off white closed pattern with flat bottom end cover and mild steel CP hinging device complete all as specified and as directed.
S&F in repairs wash hand basin mixing valve 15mm dia, Hot and Cold CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin including fittings complete all as specified and as directed.
S&F in repairs wall mixing valve Hot and Cold water Screwed Down for iron pipe 15mm dia CP brass fancy including joints to steel pipe or unions, including fittings for complete all as specified and as directed.
S&F in repairs CP brass health faucet alongwith 1.00 to 1.50 meter good quality SS flexible connection pipe suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white/ off white complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 litre capacity complete all as specified and as directed.
S&F in repairs PVC waste pipe 32mm bore, 65cm long plain/ corrugated including suitable adopter complete all as specified and as directed.
S&F in repairs stainless steel grating dome 125 mm dia of best quality complete all as specified and as directed.
S&F in repairs Brass chromium plated shower rose 125mm size with arm complete all as specified and as directed.
S&F in repairs soap dish mild steel/chromium plated brass screws complete all as specified and as directed.
S&F in repairs CP waste coupling 32 mm dia suitable for wash hand basin or kitchen sink complete all as specified and as directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx 460mm bowl size 410mmx330mmx160mm complete all as specified and as directed.
S&F in repairs PVC trap/floor trap with grating including jointing to waste pipe, dia of outlet 100mm in cement concrete 1:2:4, type B-1 complete all as specified and as directed.
S&F in repairs 15 mm bore brass chromium plated Stop valve/angle valve, fancy type, cast copper alloy complete all as specified and as directed.
S&F in repairs 15 mm bore angle valve/stop cock, chromium plated, cast copper alloy screwed down high pressure fancy type, chromium plated with long shank and cup (concealed type) screwed for both ends for iron pipe or for unions etc. complete all as specified and as directed.
S&F in repairs bib tap long body 15mm bore, chrominum plated complete all as specified and as directed.
S&F in repairs PVC connection 15mm bore and 450mm long size with brass nuts for hot water pipe complete all as specified and as directed.
S&F in repairs brass spindles with knobs (size 05 No) suitable for concealed stop valves/ bib tap/ pillar tap/ hot and cold mixture etc. all as per sample complete all as specified and as directed.
S&F in repairs PVC long bend for low level flushing cistern complete all as specified and as directed.
S&F in repairs HDPE PVC lid (cover) for 500 to 1000 Litres capacity PVC tanks complete all as specified and as directed.
S&F in repairs corner sheet glass shelf assemble consiting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing complete all as specified and as directed.
S&F in repairs toilet paper holder of brass chromium plated fixed to walls with CP brass screws complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 with waterproofing compound @ 200 ml/bag of cement complete all as specified and as directed. Note : Water proffing compound is to be paid seprately.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and as directed.
M&L 40 mm thick (average thickness) plain cement concrete 1:2:4, type B-0, using 12.5 mm graded aggregate with water proofing compund @ 3 % of cement, as in roof, padding to maintain the uniform slope complete all as specified and as directed. Notes : (a) WPC shall be measured separately and PCC shall be mixed by concrete mixer. (b) Padding on water staging shall be done after disconnecting water tank, moving to side and to be reconnected same day . (c) Water supply to effected quarters to be arranged by providing flexible connection or otherwise without any extra cost. (d) Rate are including removal of sapling/bushes and any other obstruction and filling hole. (e) Removing and refixing of Dish Antenna and other acessories if any to suitable place as directed by Eng-in-Charge
M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches), area exe 1.00 Sqm but not exceeding 3.00 Sqm, damaged due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty (JK/Birla white) to obtain even and smooth wall surfaces of that portion by using sand paper and thereafter applying two coats of oil bound distemper over a coat of primer, including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
S&F in repairs rotational moulded polythylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR-I including brass valve high pressure with polythne float and fly nut , tank nipple as required complete, screwd for iron pipe or brass ferrule size 25 mm bore complete all as specified and as directed.
S&F in repairs rotational moulded polythylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR-I including brass valve high pressure with polythne float and fly nut , tank nipple as required complete, screwd for iron pipe or brass ferrule size 25 mm bore complete all as specified and as directed.
Disconnecting existing tanks of capacity 500 litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting at other place as directed and reconnecting , repair if required and re-fixing in position complete all as specified and as directed.
Disconnecting existing tanks of 1000 liter, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting at other place as directed and reconnecting , repair if required and re-fixing in position complete all as specified and as directed.
S&F in repairs 15 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and as directed.
S&F in repairs 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and as directed.
S&F in repairs 25 mm bore Gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
Taking down eaves gutter rain water pipe (any size of pattern) including all fittings, heads, shoes, bends, swan-necks and removing from site complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps at one meter of interval complete all as specified and as directed.
S&F in repairs for PVC (SWR) bends/Tees of radius, suitable for 110mm dia PVC pipes fixed complete all as specified and as directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps at one meter of interval complete all as specified and as directed.
S&F PVC (SWR) bends/Tee etc of radius, suitable for 75mm dia PVC pipes fixed complete all as specified and as directed.
S&F in repairs 15 mm size brass chromium plated two way angle valves fancy type cast copper alloy complete all as specified and as directed.
S&F in repairs chromium plated grating in CM 1:4 as in 100mm dia of approved make including fixing floor/nahani traps etc. complete all as specified and as directed.
S&F in repairs 125mm x 100mm PVC gully traps square & round mouthed trap 'P' including case iron grating and fixed, including necessary excavation and earthwork , concrete in bed, surrounds, kerbs etc. and jointing to drains in CM 1:1 complete all as specified and as directed.
S&F in repairs tubular towel rail of brass chromium plated, 20mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings of any descreption and in any position including removal of debries outside of MoD land complete all as specified and as directed.
M&L for 15 mm thick cement plaster in sunken portion on fair faces of brick work or concrete surfaces in cement mortar 1:4, to be finished even and smooth without using extra cement with water proofing compound by weight as per manufacturer's instructions complete all as specified and as directed. Note : WPC will be measured and paid under respective item paid separately.
M&L for applying evenly a tack coat of industrial bitumen of grade 85/25 @ 1.2 kg per sqm including cleaning of surfaces complete all as specified and as directed.
M&L for cement concrete 1:5:10, type E-2, using 40mm graded crushed stone aggregate in foundations, mass concrete and filling in sunken floor etc. complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6, type C-1, using 20 mm graded stone aggregate as in plinth protection to be finished even and smooth without using extra cement including use of necessary form work etc. complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness in foor, aprons etc. complete all as specified and as directed.
M&L for machine cut 18-20mm thick Kota stone slab flooring as in floors/treads of staircase over and including cement screed 15mm thick in CM 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for Kota stone slab 18-20mm thick as in riser of steps, skirting, dado and pillar etc. laid over and including backing coat of cement plaster 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for 16 to 18mm thick Granite slabs (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cill, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over & incl one coat of red oxide primer complete all as specified and as directed.
Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed.
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
Balaji Constructions
YP INFRA
M/S Parmod Johar
Chaudhary Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .