Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.8 L+₹1.6 L (8.11%)Rejected-Finance LAL SAHAB KA BAGICHA MALL ROAD MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹22.8 L+₹2.7 L (13.4%)Rejected-Finance | L3 | Rejected-Finance Not Admitted | |
| 4 | L4₹23.0 L+₹2.9 L (14.3%)Rejected-Finance 205 LOTUS ENCLAVE PUNDAG ROAD ARGORA RANCHI JHARKHAND 834002 | RANCHI | JHARKHAND | 834002 | L4 | Rejected-Finance Not Admitted | |
| 5 | L5₹23.0 L+₹2.9 L (14.3%)Rejected-Finance HLG 223 SIDDHARTHA ENCLAYE TARAMANDAL DISTRICT GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | L5 | Rejected-Finance Not Admitted |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gwalior
Garrison Engineer Gwalior
CLEANING AND REPAIR OF SEWAGE LINE INCLUDING CONNECTED WORKS IN THE AREA OF AGE B/R-I UNDER GE GWALIOR
2021_MES_423707_1
8639/GWL/E8
Open Tender
Civil Works
Item Rate
364 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹40,000
Yes
5 Apr 2021
19 Feb 2021
20 Mar 2021
20 Feb 2021
18 Mar 2021
5 Mar 2021
60 days
Amount
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of brickwork, plain cement concrete or stone/ boulder masonry, built in cement or lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan, exc. 6m mean radius built or cement concrete, in cement mortar 1:4 as in manholes, septic tanks, soakage pits, drain etc in any position complete all as specified and directed.
M & L for brick work with sub class `B' bricks, straight or curved on plan, exc 6m mean radius, (except bricks) built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering 10mm thick on the ‘other than fair faces' side of lathing in cement mortar 1:4 over brick/concrete surfaces complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces in cement mortar (1:4) and surface finished even and smooth, complete all as specified and directed
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed.
M&L Reinforced Cement Concrete (Nominal Mix) Type B1 1:2:4 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild TMT steel bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc as in any type of soil complete all as specified and as directed.
Excavation in trenches n exc. 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation,etc.or for shafts, wells cesspits, manholes, pier holes,etc.n' exc.10 sq m on plan and getting out inany type of soil complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and exc 3m deep and n.exc 4.5 m deep for foundation,etc.or for shafts, wells cesspits, manholes, pier holes,etc.n' exc.10 sq m on plan and getting out in any type of soil complete all as specified and directed.
Returning, filling in ,including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated material (Soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Demolition and breaking up drain pipes of 100mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortarcomplete all as specified and directed.
M&L for cement concrete bed 1:4:8 type D2 to 100 mm dia drain pipes including forming cradles; in complete all as specified and directed.
M&L for 100 mm dia internal bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
Demolition and breaking up drain pipes of 150 mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortarcomplete all as specified and directed.
M&L for cement concrete bed 1:4:8 type D2 to 150 mm dia drain pipes including forming cradles; in complete all as specified and directed.
M&L for 150 mm dia internal bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
Demolition and breaking up drain pipes of 200 mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortarcomplete all as specified and directed.
M&L for cement concrete bed 1:4:8 type D2 to 200mm dia drain pipes including forming cradles; in complete all as specified and directed.
M&L for 200 mm dia internal bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
Demolition and breaking up drain pipes of 300 mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortarcomplete all as specified and directed.
M&L for cement concrete bed 1:4:8 type D2 to 300mm dia drain pipes including forming cradles; in complete all as specified and directed.
M&L for 300 mm dia internal bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
Demolition of concrete in ground floors and pavings ect n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L cement concrete in foundations, filling and mass concrete 1:4:8 type D2 using 40mm graded sand stone aggregate complete all as specified and directed.
M&L for providing, cement concrete 1:2:4 type B1 using 20mm gradedin roof kerbs or mud stops, rounded or chamfered in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed platescomplete all as specified and directed.
M&L,75 mm thick PCC 1:3:6 type C-2 using 20 mm graded stone aggregate as in plinth protection with finished even and smooth without using extra cement complete all as specified and directed.
M&L,cutting into existing manholes for connecting new drains of 100 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L,cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L,cutting into existing manholes for connecting new drains of 225 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
Demolition/dismatling and breaking up drain pipes of any dia (Salt glazed ware, AC or Reinforced concrete ect ) set in cement mortar or fixed to wall ect complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F, 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. complete all as specified and directed.
S&F, 110mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S&F for PVC (SWR) vent cowl, 75 mm bore complete all as specified and directed.
S&F, 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
M&L for Providing two coats of tap creat , M/S Cico /Pidilite , M/S Pidicrete /Nitobond M/S Fos Roc chemical mixed in proportional ratio 1:1 one part of chemical ,one part of cement slurry ,complete including curing surfaces applied,including complete in any postionall as specified and directed.
S&F in repair PVC low level flushing cistern 10 litres capacity, white, with all fitting and fixtures including brackets and 32 mm bore PVC flush pipe, complete all as specified and directed.
S&F in repair water closet including provision of cement concrete bedding viterous china squatting pan orrisa pattern of size 580x440 mm white with integral foot rest etc. excluding flushing cistern complete all as specified & directed.
S&F in repair pedestal pan std size and tap, including connection to drain and flusing pipe and seat cover closed pattern with flat bottam, anc cover and mild steel cromium plated or hinging device etc complete all as specified & directed.
Removal of vegetation growth bushes etc n. exc 30 cm girth from the earth of any height incl removal of its roots, branches and grass etc complete all as specified and directed.
Cleaning of soak well upto 2.4 m dia, upto 6 m depth (liquid depth) using mechanical pumps diesel driven with fuel, operator and necessary excavation on half buried night soil and disposed off soak well water etc in pits including necessary excavation and earth work for pits for burrying the night soil etc in soft/loose soil complete all as directed.
Cleaning/disludging of existing septic tank of any capacity/sump well etc of any dia and depth incl taking out sludge in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc means of sewage sucking machine or by way of any other suitable means and removing the sludge outside MD land by any means all as specified and directed. Note: The sludge/burried soil etc taken out shall be stacked alongwith the septic tank, sump well etc. After 48 hours of the sludge taken out, measurement shall be taken as of the solid contents for the purpose of payment. The tenderer are advised take up this aspect in mind while quotating the rates. After taking measurements, the solid contents shall be disposed off outside the MD land/area
Material and labour for cleaning of sewer line etc, of any depth, of any location, size between the sewer lines to septic tank/soak well/sump well by means of sewage sucking machine or by way of any other suitable means including disludging foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge/material out side MD land by any means/source keeping the sewage line functional for the pipe lines:-
100mm bore pipe
150mm bore pipe
200mm bore pipe
300mm bore pipe
M&L for cleaning of manholes any depth of any loc, section after cleaning trap, wc, soil/vent pipe gully trap upto and incl first manhole manually or mechanically or by way of any other suitable means or by rodding between trap and manholes incl disludging foreign material sand, ashes, fibre, silt, grease night soil etc and removing the taken out sludge/material outside MD land by any means/sources keeping the sewer line /manhole functional complete all as specified and directed.
Note for item No 53 to 56 : (i) Necssary precautions as well as safety measures shall be taken by the contractor without any extra cost for working in the foul conditions. (ii) The contractor shall be enterily responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution. (iii) The work shall be executed with all safety measures under the supervision of highly skilled workman/supervisor without entering into the septic tank, manhole, sludge chamber etc (iv) Contractor`s supervisor will report on all working days along with requisite Safai Wala for each zone/area at 0830 hrs at AGE B/R-I complaint cell to receive complaints for blockage and to submit completion report on same day by 1700hrs. (v) Printed complaints slip as per format approved by Engr-in -Charge shall be provided and mainted by contractor cost for the same shall deemed inclusive in the quoted rate (vi) All sewage blockage complaint must be attended within 24 hours. Any sewage blockage complaint is not cleared within 24 hours a compensation of Rs. 200/-per day per complaint shall be charged from the contractor. (vii) Mannual cleaning is not permitted
Babatia super works
M/s raj construction
M/s Shree Ram and Sons
M/s Maa Vaishno Construction Co.
M.S. ENGINEERS
M/S MAHAVIR SINGH
m/s yadav builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .