Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
16 Oct 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverof [V/N or 'V' whichever is less; where V = Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer must havesuccessfully completed any of the following during last 07(seven) years,ending last day of month previous to the one in which tender is invited:Three similar nature of works each costing not less than the amountequal to 30% of the advertised value of the tender, or Two similar natureof works each costing not less than the amount equal to 40% of theadvertised value of the tender, or One similar nature of work eachcosting not less than the amount equal to 60% of the advertised value ofthe tender. (b) (i) In case of tenders for composite works (e.g. worksinvolving more than one distinct component, such as Civil Engineeringworks, S&T works, Electrical works, OHE works etc. And in the case ofmajor bridges - substructure, superstructure etc.), the tenderer musthave successfully completed any of the following during last 07 (seven)years, ending the last day of the month previous to the one in whichtender is invited: Three similar nature of works each costing not lessthan the an amount equal to 30% of the advertised value of eachcomponent of the tender, or Two similar nature of works each costing notless than the amount equal to 40% of the advertised value of eachcomponent of tender, or One similar nature of work each costing not lessthan the amount equal to 60 % of the advertised value of eachcomponent of the tender. Note for b(i): Separate completed works ofminimum required values for each component shall also be consideredfor fulfillment of technical eligibility criteria. (b) (ii) In such cases, whatconstitutes a component in a composite work shall be clearly predefinedwith estimated tender cost of it, as part of the tender documents withoutany ambiguity. (b) (iii) To evaluate the technical eligibility of thetenderer, only components of work as stipulated in tender documents forevaluation of technical eligibility shall be considered. The scope of workcovered in other remaining components shall be either executed by thetenderer himself if he has work experience as mentioned in clause 7 (a)(ii) of Part-II of GCC or through subcontractor fulfilling the requirementsas per clause 7 of Part-II of GCC or jointly i.e., partly himself andremaining through subcontractor, with prior approval of Chief Engineerin writing. However, if required in tender documents by way of SpecialConditions, a formal agreement duly notarised, legally enforceable in thecourt of law, shall be executed by the main contractor with thesubcontractor for the component(s) of work proposed to be executed bythe subcontractor(s), and shall be submitted along with the offer forconsidering subletting of that scope of work towards fulfillment oftechnical eligibility. In case after the award of the contract or during theexecution of work it becomes necessary for the contractor to changesubcontractor, the same shall be done with subcontractor(s) fulfilling therequirements as per clause 7 of Part-II of GCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor licenseas per Indian Electricity Rules for the respective category ofworks issued by Government Electrical License Board on orbefore the closing date of tender. Copy of the electricalcontractor license should be submitted along with the tenderoffer, otherwise, the tender will be summarily rejected.
52 conditions · 5 needing a document upload
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE SUBMITTED
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Augmentation and replacement of electrical asset of Substation, Railway Colony, Power house & DRM building under the jurisdiction of SSE/P/LMG & SSE/P/NHLG.
EL-LM-26-27-14~NFR
EL-LM-26-27-14
Open
Works - General
180 Days
Hojai, Assam
₹0
₹6.4 L
25 Sept 2026
25 Sept 2026
2 Oct 2026
151 items across 8 schedules · ₹3,19,73,415.01 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of 14.5 Mtr. long GI pole for HT Line type 410 SP-76 with step length 6.5-4.0-4.0 Mtr sectional dia 219.1x193.7x165.1mm sectional thickness 5.9x4.85x4.5mm. including suitable size base plate and cap on top. The material Construction(pipe) shall confirm to IS:1161/IS:1239 and shall be able to withstand maximum wind speed conformingto IS:875. Anti-climbing device by barbed wire upto 2.5 mtr height with necessary GI clamp/nut/bolts, etc has to be provided.Danger Board of size 8"X6" fixed with suitable GI clamp has to be provided showing the voltage grade, skull etc. The whole work shall be executed as per direction of Engineer in charge at site. | Numbers | 15.00 | 54,083.77 | 8,11,256.55 |
| 2 | Supply of GI tubular pole 12 Mts. long type - 410 SP-63 for LT line with step length 5.8-3.1 3.1 Mtrs., section diameter 193.7 x 165.1 x 139.7 mm sectional thickness 4.85 x 4.50 x 4.50 mm respectively as per IS 2713 of 1980 including suitable size of base plate and cap on top. The material Construction(pipe) shall confirm to IS:1161/IS:1239 and shall be able to withstand maximum wind speed conformingto IS:875. Anti-climbing device by barbed wire upto 2.5 mtr height with necessary GI clamp/nut/bolts, etc has to be provided.Danger Board of size 8"X6" fixed with suitable GI clamp has to be provided showing the voltage grade, skull etc. The whole work shall be executed as per direction of Engineer in charge at site. | Numbers | 50.00 | 41,600.02 | 20,80,001 |
| 3 | Supply, transportation, loading, unloading, and erection of 9.0 m long galvanised tubular steel pole conforming to Type 410 SP-33 for LT line and IS 2713:1980 steel tubular poles specification, having approximate weight of 164 kg, made in three stepped sections of 5.0 m, 2.0 m, and 2.0 m lengths with respective outer diameters of 165.1 mm, 139.7 mm, and 114.3 mm and wall thicknesses of 5.40 mm, 4.50 mm, and 3.65 mm, including supply of suitable base plate and pole cap, complete in all respects; the work includes excavation of pit to a depth equal to one-fifth of the pole height, erection, alignment and plumbing of the pole, and providing and laying cement concrete foundation of size 450 mm x 450 mm in 1:2:4 mix using cement, sand and 19 mm down graded stone aggregates up to full depth of pit and 300 mm above ground level, including compaction, curing and finishing, as per directions of the Engineer-in-Charge, complete with all labour, materials, tools, tackles and contractor's own arrangements. | Numbers | 40.00 | 15,984.1 | 6,39,364 |
| 4 | Erection of G.I. tubular pole to 1/5 th of its height with CC foundation M15 from base block (30 cm x 30 cm x 15 cm) including digging & refilling of earth to a height of 30 cm above ground level in ratio 1:3:6 by cement, sand & Chips 20-25 mm & down including excavation of earth(erection of above mentioned item no. 1 & 2) | Numbers | 65.00 | 1,374.68 | 89,354.2 |
| 5 | Supply, erection, testing & commissioning of LT Galvanized stay set OH line complete with19/20 mm diameter 1.8 Mts long stay rod, Anchor plate of size 30x30 cm x 6 mmthick, thimble, stayclamp turn buckle (20x 600)mm, 7/10 SWGstay wire and straininsulator etc. in CC foundation of ratio1:3:6 including excavation/refilling etc. as per direction of site Engineer in -charge of railway. | Set | 22.00 | 630.42 | 13,869.24 |
| 6 | Supply, erection and commissioning of 2P composite polymer 11 KV Pin insulator ( 10 KN) with minimum creepage distance 340mm & sectional length 235mm made of one piece injection moulded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting | Numbers | 30.00 | 367.22 | 11,016.6 |
| 7 | Supply erection and commissioning of 2P composite polymer 11 KV ball & socket type Disc insulator (>70 KN) with minimum creepage distance 320mm & sectional length 300mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting. | Numbers | 30.00 | 616.49 | 18,494.7 |
| 8 | Supply of materials and Painting of existing tubular pole by paint of 2 coats of red oxide & 2 coats of silver paint from 2 ft to top & 2 coat of black paint up to 2 ft. from foundation level including angle iron, bracket, cross arm, clamps, nut-bolts etc complete in all respect with supply of paint. The whole work shall be executed as per direction of Engineer in charge at site. | Numbers | 100.00 | 839.56 | 83,956 |
| 9 | Supply, laying, binding and stringing of guard wire by 8 SWG GI wire and cross lacing by 10 SWG GI wire. Cross lacing shall be provided not more than 1 meter interval. | RM | 1000.00 | 7.93 | 7,930 |
| 10 | Supply, fitting, fixing and clamping of 90 mm Dia HDPE pipe along with all the accessories like socket, bend, couplers etc.of working pressure of 6 Kgf per sq cmConforming to IS 4984/1995. The work shall include supply of all necessary accessories such as HDPE sockets, bends, couplers, tees, reducers, end caps, clamps, nuts, bolts, washers and supporting arrangements as required at site. The pipe shall be laid above ground or mounted on RCC wall/structure as per site requirement. The pipe shall be properly aligned, cut to required length and joined using appropriate jointing method (compression fitting / butt fusion / electrofusion as applicable) to ensure leak- proof and rigid joints. Proper MS/GI clamps with suitable spacing, anchor fasteners, and supporting brackets shall be provided for fixing the pipe on wall or structure. All cutting, jointing, fitting, alignment and fixing works shall be carried out carefully to avoid damage to the pipe. The entire work shall be executed as per the direction of Engineer-in-Charge. | Metre | 500.00 | 174.29 | 87,145 |
| 11 | Supply, fixing, clamping, and laying of 63 mm dia HDPE pipe of pressure rating 6.0 kgf/cm² (PN-6) along poles/beams/brackets using 25 x 5 mm MS clamps with necessary nuts, bolts, and washers, or laying underground by digging a trench of 1 m depth wherever required. Necessary compression sockets and short radius compression bends shall be provided as per the directions of the Railway Engineer. Pre- inspection of materials by the Railway Engineer shall be carried out before installation. | Metre | 500.00 | 98.76 | 49,380 |
| 12 | Supply & erection of Single longitudinal welding Single dipped Galvanizing Octagonal pole 6Mts. long type - BOP-6030 with 70mm Top Diameter &130 mm Bottom Diameter and Steel thickness 3 mm as per ISO 9001 of 2000 &ISO14001 including suitable base plate of size 220mmx220mmx12mm and cap on top including Supply and construction of CC foundation work including Anchor type Foundation Bolts 4 Nos. 20mm diameter & 600mm length ( 4 Nos. in onegroup) in C.C. foundation & 6 Amps SP MCB , fixing of Bakelite Sheet terminals and 2x1.5 sq mm FRLS Cu cable for MCB to Street light fitting connection and The door shall be flush with the exterior surface and shall have suitable hinged type locking arrangement. The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron.The GI Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The top loading i.e. area and the weight of fixtures are to be considered to calculate maximum deflection of the pole and the same shall meet the requirement of BSEN 40-3-3:2003. The length of the pole shall be as per illumination design.The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per qualified MMAW (manual metal arc welding ) process approved. The whole work shall be executed as per direction of site engineer. | Numbers | 40.00 | 11,832.49 | 4,73,299.6 |
| 13 | Supply of 1 Meter Length Single ARM G.I. Decorative Bracket suitable for 6 mtr Octagonal pole menioned above the item no. 12 | Numbers | 40.00 | 3,126.41 | 1,25,056.4 |
| 14 | Supply, fitting, fixing, connection and commissioning of 90 W Warm White Decorative tear drop light luminaire having Luminous Flux: 8000 lumens, Color Temperature: 3000K (Warm White), Ingress Protection:IP65 or higher for outdoor use, Impact Protection: IK08 or higher, comprises by Spun housing and clear cove, System efficacy 120 LPW, 4 kV internal and 10 kV external surge arrestor. suitable for Crompton Decorative pole CG-DECO-21 & arm HM-DECO- SANS (Crompton Cat Ref. CBP-601-90-30-HL2- CP-NGG) Warranty: Minimum 2 years for luminaire. | Numbers | 40.00 | 10,719.12 | 4,28,764.8 |
| 15 | Dismantling/Uprooting of existing Rail/Tubular Pole with all accessories without damage from the work site and handing over to SSE incharge office asper instruction of site Engineer in- charge of railway. | Numbers | 40.00 | 954.8 | 38,192 |
| 16 | Dismantling of unusable corroded ACSR conductor, guard wire, brackets, etc., and depositing the released materials in full quantity to the concerned Railway Site Engineer under proper challan after due accounting and recording in the Contractor's Account (CA). | Each Span | 40.00 | 104.95 | 4,198 |
| 17 | Horizintal directional drilling boring (HDD) of 14/16" dia hole across existing Railway Track to facilitate passing of 12" dia CI/GI pipe 2.5 mtr belowGL without damaging the existing track formation, S&T cables andother structures utilized for traffic movement as per following specifications : 1. The directional boring machnine equipment shall consist of directional boring rig of sufficient capacity to successfully completethe crossing, a guided system toaccurately guide the boring operations and trained and competent personnel to operate the system. 2. All equipment shallbe in good, safe operating condition with sufficient supplies,materials and spare parts on hand to maintain the system in goodworking order. The directionalboring machine shall consist ofhydraulically powered system torotate, push and pull of hollwdrilled pipe into the ground atvariable angle while delivering the pressurized fluid mixture to aguidable drill (bore) head 3.The machine shall be anchored to the ground to with stand the pulling,pushing, rotating pressure required to complete crossing. The hydraulic power system should be self contained with sufficient pressure and volume operations and leak free. 4.The bore head shall be steerable by changing its rotationand shall provide the necessary cutting surfaces and boring fluidjets. 5. The mud motors shall be of adequate power to turn the required boring tools. 6.Mixing system shall be sufficient to mixand deliver boring fluid composed of bentonite clay, potable water and appropriate additives 7.Drilling fluid shall be composed of clean water and appropriate additives. The work to be xecuted as per instruction of engineer in charge. | Metre | 90.00 | 6,345.64 | 5,71,107.6 |
| 18 | Stringing, sagging, dressing and fixing of LT Aerial Bunched (AB) Cable of size 3 x 50 sq.mm + 1 x 35 sq.mm Messenger (Neutral) + 1 x 16 sq.mm Street Lighting Conductor, including loading, unloading, transportation to the actual work site, laying, tensioning, sagging, and all incidental works complete as per manufacturer's recommendations and the directions of the Engineer-in-Charge. The rate shall include all labour, tools & tackles, consumables, and contractor's own arrangements for handling and carriage of materials from the designated storage location to the site of installation. | Metre | 1600.00 | 36.89 | 59,024 |
| 19 | Supply, installation, testing and commissioning of weatherproof Junction Box of size 390 x 305 x 170 mm (approx.) made of SMC/FRP with hinged door, neoprene/rubber gasket, padlock arrangement, zinc-passivated earthing bolt, suitable for outdoor installation. The Junction Box shall be complete with 4 Nos. aluminium busbars, each of 200 A rating and 25 mm x 10 mm size, complete with suitable insulated supports, shrouds, glands, gland plate, terminals, nuts, bolts and all necessary accessories. The Junction Box shall be suitable for 415 V, 3-phase, 4-wire AC supply and conform to relevant IS/IEC standards. The item includes all labour, tools & tackles, consumables, fixing hardware, testing and commissioning complete as directed by the Engineer-in-Charge. | Numbers | 25.00 | 1,597.73 | 39,943.25 |
| 20 | Supply, installation and fixing of LT Suspension Clamp Assembly suitable for bare messenger of LT Aerial Bunched (AB) Cable, comprising 1 No. suspension clamp with mounting bracket, 1.5 m long stainless steel (SS) strap, and 2 Nos. stainless steel buckles, complete with all necessary hardware, accessories, labour, tools & tackles, and consumables for proper installation on pole/support as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 20.00 | 341.53 | 6,830.6 |
| 21 | Supply, installation and fixing of I-Hook suitable for mounting anchor clamp and suspension clamp assemblies for LT Aerial Bunched (AB) Cable on RCC/PSC/steel poles, complete with all necessary nuts, bolts, washers, fastening accessories, labour, tools & tackles, and consumables required for proper installation, as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 25.00 | 95.2 | 2,380 |
| 22 | Supply, installation and fixing of Anchoring/Dead-End Clamp Assembly suitable for bare/insulated messenger of LT Aerial Bunched (AB) Cable, comprising 1 No. anchor/dead-end clamp, 1 No. universal mounting bracket, stainless steel (SS) strap with buckles, and all associated nuts, bolts, washers and accessories, complete in all respects. The item includes all labour, tools & tackles, consumables, and proper fixing on pole/support as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 25.00 | 396.27 | 9,906.75 |
| 23 | Supply of Insulation Piercing Connector (IPC) suitable for street lighting branch connection and earthing in LT Aerial Bunched (AB) Cable system, complete with shear-head bolts, waterproof insulation, contact teeth, insulating caps, and all associated accessories. The connector shall be suitable for the specified conductor sizes, provide reliable electrical contact without stripping the insulation, and conform to relevant IS/IEC standards. The item includes all necessary accessories required for complete installation as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 36.00 | 159.46 | 5,740.56 |
| 24 | Supply, installation and commissioning of Steel strap of size 20 mm for installation of DB including 02 Nos. Buckles of suitable size as per direction of Engineer In-charge at site. | Set | 35.00 | 291.55 | 10,204.25 |
| 25 | Supply and fitting, fixing of G.I. Pole Clamp made of 25 mm x 6 mm Galvanized Iron flat, suitable for mounting electrical accessories/equipment on tubular steel poles. The item shall include drilling of necessary holes, nuts, bolts, washers, and all other fastening materials, along with labour, tools & tackles, and consumables required for complete installation as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 25.00 | 151.13 | 3,778.25 |
| 26 | Supply, installation and commissioning of Insulation Piercing Connector (IPC) suitable for street lighting branch connections and earthing in LT Aerial Bunched (AB) Cable systems, complete with shear-head bolts, insulated housing, waterproof sealing, contact teeth, insulating end caps, and all associated accessories. The connector shall be suitable for the specified conductor sizes, ensure reliable electrical contact without removing conductor insulation, and conform to relevant IS/IEC standards. The item includes all labour, tools & tackles, consumables, testing, and commissioning, complete in all respects, as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 32.00 | 159.46 | 5,102.72 |
| 27 | Supply, installation, testing and commissioning of outdoor type 11 kV, 400 Amps, 3-phase Air Break Gang Operated off-load Disconnecting Switch (GOS) with Drop Out (DO) fuse set complete with operating mechanism, operating pipe, base frame/channel, arcing horns, fuse assembly, polymer/porcelain insulators, terminal connectors, galvanized steel structure, earthing terminals and all standard accessories suitable for outdoor installation under tropical climatic conditions. The Gang Operated Switch (GOS) shall conform to IS 9921 (Part I to Part V) for AC disconnectors and earthing switches for voltages above 1000 V and relevant provisions of IEC 62271-102. The DO fuse assembly shall conform to IS 9385 (Part I to III) and relevant provisions of IEC 60282 for high voltage expulsion/drop out fuses. The porcelain/polymer insulators shall conform to IS 2544, and all ferrous parts shall be hot dip galvanized as per IS 2629 and IS 4759. The switch shall be suitable for operation on 11 kV, 50 Hz AC system with rated voltage of 12 kV, rated continuous current of 400 Amps, short time withstand current of minimum 16 kA for 3 seconds, and insulation level suitable for 28 kV power frequency withstand voltage and 75 kVp lightning impulse withstand voltage. The contacts shall be made of high conductivity electrolytic copper/silver plated material with suitable spring-loaded arrangement for reliable operation. The DO fuse unit shall be complete with tinned copper fuse tube assembly and suitable size fuse wire/element. The complete work shall include supply of all mounting hardware, clamps, nuts, bolts, washers, danger plates, anti-climbing devices, earthing arrangements, erection, testing and commissioning for satisfactory operation at site. | Set | 10.00 | 7,833.98 | 78,339.8 |
| 28 | Supply, installation, testing and commissioning of 11 kV, 200 A Air Break Gang Operated (ABGO) switch, outdoor type, triple pole, horizontal/vertical break with double break contacts, complete with three nos. of rocking type double stack post insulators made of high-quality porcelain/polymer conforming to relevant IS standards (IS:2544/IS:731 or latest). The current carrying parts shall be made of high conductivity, corrosion-resistant material with silver-plated contacts to ensure low contact resistance and reliable operation. The switch shall be suitable for operation on 11 kV, 50 Hz system and designed to withstand mechanical and electrical stresses including wind load as per IS:875. The operating mechanism shall be gang operated through a sturdy handle arrangement with provision for padlocking in open/close position, and interlinked through 25 mm dia, 3.25 mm thick GI pipe for simultaneous operation of all three phases. All ferrous parts shall be hot-dip galvanized as per IS:2629/IS:4759. The switch shall be mounted on suitable GI structure/pole with necessary clamps, nuts, bolts and hardware. The work includes complete erection, alignment, proper clearances, earthing arrangement, and testing such as insulation resistance, contact resistance and operational checks. The entire work shall be carried out as per relevant IS specifications and as directed by the Engineer-in-Charge. | Set | 10.00 | 6,660.38 | 66,603.8 |
| 29 | Supply, installation, testing and commissioning of 11 kV Drop Out Fuse (DO Fuse) assembly, polymer type, suitable for outdoor service, complete with channel type base structure and tinned copper fuse carriers. The fuse assembly shall be rated for 11 kV system voltage and 200 A current capacity, suitable for fault interruption and protection of distribution feeders. The insulator shall be of high quality polymer/composite material with excellent anti-tracking, UV resistance, and weatherproof properties conforming to relevant IS standards (IS:9385/IS:9921 or latest amendments). The fuse carrier shall be provided with suitably rated fuse wire/link in SWG units as per system fault level and coordination study. The complete assembly shall have robust mechanical strength, proper contact pressure, and low contact resistance to ensure reliable operation under fault conditions. The structure shall be hot-dip galvanized and suitable for mounting on pole or structure with necessary clamps, nuts, bolts, and hardware. The work shall include proper alignment, earthing arrangement, testing of insulation resistance and operational performance, and commissioning as per relevant IS specifications and as directed by the Engineer-in-Charge. | Set | 10.00 | 4,199 | 41,990 |
| 30 | Supply, stringing, tensioning, sagging, binding and jumpering of ACSR Conductor conforming to IS 398 (Part II):1996 (latest amendment, if any), Raccoon size 6/1/4.09 mm (6 Aluminium + 1 Steel wire, each of 4.09 mm diameter), including loading, unloading, transportation to site, erection, binding on insulators, formation of jumpers, jointing at terminal points, and all incidental works complete. The conductor shall be strung to the specified sag and tension as per relevant standards and the manufacturer's recommendations. No mid-span joints shall be permitted; the conductor shall be continuous between two tension (dead-end) points. The item includes all labour, tools & tackles, consumables, and testing, complete as directed by the Engineer-in-Charge. | Metre | 1200.00 | 25.14 | 30,168 |
| 31 | Stringing, carrying, dressing, fixing, testing and commissioning of 11 kV, 1-Core, 120 sq.mm Medium Voltage Covered Conductor (MVCC) complete with all associated fittings and fixtures, including suspension clamps, dead-end/anchor clamps, spacers (where required), binding accessories, connectors, hardware, nuts, bolts, washers, and all other materials necessary for proper installation. The item includes loading, unloading, transportation to the work site, erection, tensioning, sagging, fixing on poles/supports, testing, commissioning, labour, tools & tackles, consumables, and all incidental works, complete in all respects, as per the manufacturer's recommendations, relevant IS/IEC standards, and the directions of the Engineer-in-Charge. | Metre | 4500.00 | 98 | 4,41,000 |
| 32 | Supply, installation and fixing of Anchoring/Dead-End Clamp Assembly suitable for 11 kV Medium Voltage Covered Conductor (MVCC) with bare/insulated messenger, comprising 1 No. anchor/dead-end clamp, 1 No. universal mounting bracket, stainless steel (SS) strap with SS buckles, and all associated hardware and accessories, complete in all respects. The clamp body shall be manufactured from corrosion-resistant aluminium alloy, the bail shall be of stainless steel, and the wedges shall be made of weather-resistant and UV-stabilized polymer. The assembly shall conform to EN 50397-2 (latest edition) and be suitable for the specified conductor size. The item includes all labour, tools & tackles, consumables, loading, unloading, transportation, fixing on pole/support, testing, and commissioning, complete as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 15.00 | 18,260 | 2,73,900 |
| 33 | Supply, installation, testing and commissioning of Insulation Piercing Connector (IPC) suitable for 11 kV Medium Voltage Covered Conductor (MVCC) system for tap/branch connections, complete with all associated accessories. The blade/contact element shall be made of tin- plated copper, contact plates of high- conductivity copper, bolts of high-strength steel with Geomet (chromium-free) corrosion protection, and the insulation body shall be manufactured from weather-resistant and UV- stabilized glass fibre reinforced polymer. The connector shall be provided with a 13 mm long-neck shear-head nut to ensure reliable and tamper-proof installation without damaging the conductor insulation. The IPC shall be suitable for the specified conductor sizes and shall provide a watertight, maintenance-free electrical connection. The connector shall conform to EN 50483-2 (latest edition). The item includes all labour, tools & tackles, consumables, testing, commissioning, and all incidental works required for complete installation as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 18.00 | 3,000 | 54,000 |
| 34 | Supply and fitting of Suspension Clamp Assembly suitable for 11 kV Medium Voltage Covered Conductor (MVCC), comprising 1 No. suspension clamp with mounting bracket, 1.5 m long stainless steel (SS) strap, and 2 Nos. stainless steel buckles, complete with all necessary nuts, bolts, washers and associated accessories. The clamp body shall be made of corrosion-resistant aluminium alloy, with stainless steel hardware and weather- and UV- resistant polymer inserts, suitable for long- term outdoor service. The suspension clamp assembly shall conform to EN 50397-2 (latest edition) and be suitable for the specified conductor size. The item includes loading, unloading, transportation to site, labour, tools & tackles, consumables, fixing on pole/support, testing, and commissioning, complete in all respects as per the manufacturer's recommendations and the directions of the Engineer-in-Charge at site. | Numbers | 15.00 | 13,145 | 1,97,175 |
| 35 | Excavation of cable trench 1.0 m x 0.5 m below the GL with laying of armored cableand refilling the same by supply of Brick, Sand and Soil after digging the earth asper direction of Engineer at site & connection of armored Cable by supply and fixingof crimping lugs of suitable size etc. The entire excavation of cable is to done as per drawing no.PCEE/ELG/DRG/2024/2, dt. 04.10.2024 | Metre | 440.00 | 121.79 | 53,587.6 |
| 36 | Tree trimming to be done to maintain a minimum horizontal & vertical clearance as per IE rule from Over Head Line. One big branch consisting minimum of 5 small sub branches as per direction at site Engineer in- charge of Railway. | Each Span | 500.00 | 54.6 | 27,300 |
| 37 | Supply, installation, testing and commissioning of outdoor type 33 kV, 400 Amps, 3-phase Gang Operated Air Break (GOAB) Switch complete with operating mechanism, operating pipe, base frame, arcing horns, terminal connectors, insulators, galvanized steel structure, earthing terminals and all standard accessories suitable for outdoor installation under tropical climatic conditions. The GOAB switch shall conform to IS 9921 (Part I to Part V) for AC disconnectors and earthing switches for voltages above 1000 V and relevant provisions of IEC 62271-102. The porcelain/polymer insulators shall conform to IS 2544, bushings if provided shall conform to IS 2099, and all ferrous parts shall be hot dip galvanized as per IS 2629 and IS 4759. The switch shall be suitable for operation on 33 kV, 50 Hz, AC system with rated voltage of 36 kV, rated continuous current of 400 Amps, short time withstand current of minimum 16 kA for 3 seconds, and insulation level suitable for 70 kV power frequency withstand voltage and 170 kVp lightning impulse withstand voltage. The complete work shall include supply of all mounting hardware, nuts, bolts, clamps, connectors, danger plates, anti-climbing devices, earthing arrangements, painting, erection, testing and commissioning as required for satisfactory operation at site. | Set | 5.00 | 20,193.88 | 1,00,969.4 |
| 38 | Supply, installation, testing and commissioning of outdoor type 33 kV Drop Out (DO) fuse set complete with polymer barrel enclosure, tinned copper fuse tube assembly, arcing horn, fixed and moving contacts, mounting arrangement, and suitable size fuse wire/element for 33 kV system, suitable for outdoor operation under tropical climatic conditions. The DO fuse set shall conform to relevant provisions of IS 9385 (Part I to III) for high voltage fuses and IEC 60282, with polymer insulators conforming to relevant applicable IS/IEC standards. The fuse assembly shall be suitable for operation on 33 kV, 50 Hz AC system with rated voltage of 36 kV and adequate rupturing capacity. The contacts shall be made of high conductivity tinned copper/brass with anti-corrosive treatment. All ferrous parts shall be hot dip galvanized as per IS 2629 and IS 4759. The item shall include complete mounting hardware, connectors, clamps, nuts, bolts, washers, earthing arrangements, suitable size fuse wire in SWG, erection, testing and commissioning for satisfactory operation at site. | Set | 5.00 | 15,350.72 | 76,753.6 |
| Schedule total | ₹71,17,083.27 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-14N.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .