Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.2 L+₹6.5 L (31.4%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹28.8 L+₹8.1 L (38.9%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹31.8 L+₹11.1 L (53.6%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹40.2 L+₹19.5 L (94.1%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
6 Jul 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF INTERNAL ELECTRIFICATION AND FIXTURE AND CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN, VOLTAGE STABILIZER INCLUDING CONVENTIONAL LIGHT INTO LED EFFICIENT FITTING IN THE AREA OF AGE E/M HOSP UNDER GE E/M LUCKNOW
2021_MES_447511_1
GE/EM/LKO/HOSP/T-16 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹98,000
Yes
3 Aug 2021
1 Jun 2021
8 Jul 2021
1 Jun 2021
6 Jul 2021
24 Jun 2021
Amount
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
All as per Sl item No 1 above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per Sl item No 1 but for one socket outlet point on same the baord with other switches.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type of of polycarbonate, SP,5/6 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type of polycarbonate , SP, 16/20 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let 2 in 1 socket 5 pin of polycarbonate , (6 Amps) flush type controlled by one switch complete all as specified and as directed by Engineer-in- Charge.
Socket out let of polycarbonate 6 pin, 20 Amps ,complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
Moduler switch 10 Amp, SP, one way with indicator -01 Module, 250 Volts AC, square white mechanisms as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Moduler switch 1 way 16A, 1 modules square white mechanisms as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Moduler socket shuttered 6 Amps, 3 Pin Universal India -2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Moduler socket shuttered 6/16 Amps, 3 Pin Universal India -2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Ceiling fan regulator electronic type deluxe 240 Volts 5 step ISI Marked as in replacment ,complete all as specified and as directed by Engineer-in- Charge.
White cover plate with frame, 1 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
White cover plate with frame, 2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Metal flush box 1/ 2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Switch socket combination 2 in 1,3 pin , 5 & 15 Amps flush type universal, controlled by one switch as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Socket outlet multipurpose 3 pin , 10/20 Amps , controlled by one switch as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Socket outlet multipurpose 3 pin , 6 Amps , controlled by one switch as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Switch, 06 Amps white colour as in replacement ,complete all as specified and directed by Engineer-in- Charge. by Engineer-in- Charge.
Switch, 16 Amps white colour as in replacement ,complete all as specified and directed by Engineer-in- Charge. by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 12 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, 240 Volts to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCBs SPN/ Isolator, 40 Amps, 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Single pole enclosure box suitable for MCB SP of capicity 6 to 32 Amps B/C type as in replacment ,complete all as specified and directed by Engineer-in- Charge.
DP/TP/FP enclosure box suitable for MCB SPN/MCCB of Capicity 32 to 63 amps ,SPN/TP/TPN as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Sub main wiring (concealed type ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 4 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring (concealed type ) with two single core 10 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 10Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 10 Sqmm ,1 run of PVC conduit & 1 run of 10 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. , complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Distribution Board TPN with and including of DPX MCCB 35 KA 250 Amps MCCB FP as incomer and SP/TPN MCBs as outgoing protection class IP 54 , 8 way (DPX 250+24) with metal double door as in replacement, complete all as specified and directed by Engineer-in-Charge. Note :- FP MCCBs 35 KA 160 Amps 1 No and 24 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this item .
Distribution Board TPN with and including of DPX MCCB 35 KA 160 Amps MCCB FP as incomer and SP/TPN MCBs as outgoing , 4 way with metal double door as in replacement,complete all as specified and as directed by Engineer-in- Charge. Note :- FP MCCBs 35 KA 160 Amps 1 No and 24 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this item .
Distribution Board TPN with and including of 100 amp FP Isolator as incomer and SP/TPN MCBs as outgoing , 4 way with metal double door as in replacement,complete all as specified and as directed by Engineer-in- Charge. Note :- FP Isolator 100 Amps 1 No and 12 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this item
Flexible copper cable three core 0.75 sqm suitable for connection for electric fititing and fixture as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Flexible copper cable three core 1.50 sqm suitable for connection for electric fititing and fixture as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Flexible copper cable three core 2.50 sqm suitable for connection for electric fititing and fixture as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Plug top 15 Amp as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Plug top 5 Amp as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Gang box with switch and socket 5 Amp as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Gang box with switch and socket 15 Amp as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
LED CFL 4 pin 36 watts 4 Pin , suitable for CFL light fittings witn electric connection as in replacement ,complete all as specified and as directed by Engineer-in- Charge. Make:- Havells Cat Part No PHOTONULTRAPLL419TL18WLED856SPC or equvalent make as per PS
Recess LED llight fittings of size 1X1 05 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Recess LED llight fittings of size 2X2 36 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Recess LED llight fittings of size 1X1 15 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing(in repairs) of Recess LED llight fittings of size 2X2 20 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept all as specified and directed. make havells cat part no, venusneohe2x2plr18-42wled830mod or eqvlnt make as per ps
All as per item No 47 above but 2X2 22 watt warm cool type all as specified and directed
Recess LED llight fittings of round shape 10 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate , environment friendly, energy efficient ready to use pack LED Tube light fittings with battern of capacity 18 watt (2 feet) complete all as specified and directed by EIC Make: HAVELLS CAT PART NO LUMILINEBS 18WLED865SPCWH OR equivalent make as per PS
Fixing Only Recess LED llight fittings of 4X1 of 30 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge. (Note:- Material should be issued by department for free fixing
Lamp holderbattern/anguler type , PVC/polycarbonate type with cord grip cap suitable for pendant fittingsas in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Fixing only LED TUBE light fittings with battern of capicity 18/20 watt (4 feet) ,complete all as specified and as directed by Engineer-in- Charge. (Note:- Material should be issued by department for free fixing)
Fixing only FTL battern and S&F Ultra bright glass shall, glare free, wide angle single side connection retrofit LED tube with G13 lamp holders New Batten suitable for LED tube rod 18/20 watt prewires including connection complete all as specified and as directed by Engineer-in- Charge. (Note:- Material should be issued by department for free fixing)
Disconnecting of ceiling fans of 1200 mm sweep from ceiling rose/connector for cleaning, servicing /oiling and greasing of fan by using appropriate grade of oil / grease and replacing defective parts such as bush bearing , split pin rubber bush, capacitor etc and rehanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded complete all as specified and as directed by Engineer -in-Charge (NOTE :- Parts/component will measuared and paid separtely under respective item of the schedules).
Rewinding of ceiling fan 1200 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate/existing gauge/size including packing, insulating material soldering varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge
All as per item No 56 above but 1400 sweep.
Bearing of ceiling fans for ceiling fans of 1200/1400mm sweep to suit for different makes of fans of approved quality including necessary greasing complete all as specified and as directed by Engineer -in-Charge
Bushes gun metal suitable for ceiling fans 1200 / 1400 mm sweep complete all as specified and as directed by Engineer -in-Charge at site.
Condenser / capacitor suitable for 230 volts single phase ceiling fan 1200mm / 1400 sweep of any make and quality of capacity 2.5 MFD complete all as specified and as directed by Engineer -in-Charge
All as per item No 60 above but 3.15 MFD.
Painting of ceiling fan 1200/1400mm sweep AC 230 volts single phase complete in situ or at contractor workshop with synthetic enamelled white/matching paint by spraying one cost including filling of cavities after cleaning all dust and marking SM/MES NO with black enamelled paint complete all as specified and as directed by Engineer -in-Charge
Ceiling fan 1200 mm sweep AC 230 volts single phase including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge
Condenser / capacitor suitable for 230 volts single phase exhaust fan 300mm to 450 sweep of any make and quality of capacity 4 MFD complete all as specified and as directed by Engineer -in-Charge
Exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete all as specified and as directed by Engineer -in-Charge
Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complete with synthetic enamelled white / grey / matching paint by spraying one coat including filling of cavities after cleaning all dust and marking SM/MES NO with black enamelled paint complete all as specified and as directed by Engineer -in-Charge
Exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge
Exhaust fan 380 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge
Exhaust fan 450 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge
Exhaust fan fresh air 250 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge
Rewinding of wall fan 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge
Fixing only Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including making necessary electrical connection with ceiling rose complete all as specified and as directed by Engineer -in-Charge (Note:- Material should be issued by department for free fixing)
Voltage stabilizer for automatic operation single phase intelligent Time Delay System, Compatible with Regular & Inverter ACs, Wall Mounting Cabinet Design, Energy efficient design, smart Digital Display, Built In Thermal Overload Protection Low & High Voltage Cut-off Protection, Latest IC Technology of capicit 05kVA . make -V Gaurd Cat part MOP suitable for 2.0 TR inverter AC or equivalent
DEV INFRATECH
Unnati Engineers
Ajanta Motor Store
m/s raghubar dayal
M/s Solution
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .