| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹19.7 L+₹61,900 (3.24%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹20.0 L+₹83,850 (4.38%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹21.2 L+₹2.1 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹21.2 L+₹2.1 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
₹31 L
Closing Date
30 Jun 2022, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR/MAINT OF INTERNAL WIRING AND LUMINARIES OF OTM AND OTHER ACCN AT LALGARH JATTAN MIL STATION.
2022_MES_527830_1
8933-18/22-23
Open Tender
Coal Works
Item Rate
180 days
GE Lalgarh Jattan
Class D Cat b (I)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
Exempted
29 Aug 2022
1 Jun 2022
2 Jul 2022
1 Jun 2022
30 Jun 2022
16 Jun 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good distrubed surfaces of walls and floors etc to match with the existing all as specifided and directed by Engineer-in-Charge.
Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc all as directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surface all as directed by Engineer-in-Charge.
Material and labour for point wiring with 1.5 sqmm, FRLS, single core PVC insulated, unsheathed, multistranded copper conductor cable, with universal colour code in and including medium grade rigid PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulated unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch and making good diturbed surfaces complete all as specified and directed by Engineer-in-Charge.
All as per item No 4 above, but for one ceiling/exhaust fan point controlled by one switch and regulator.
All as per item No 4 above, but for one bell/buzzer point controlled by one bell push.
All as per item No. 4 here-in-before but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on same board
All as per item No. 4 here-in-before but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on independent board
All as per item No. 4 here-in-before but controlled with two No. two way switches
Material and labour for point wiring with 1.5 sqmm, FRLS, single core PVC insulated, unsheathed, multistranded copper conductor cable, with universal colour code drawn in existing steel/PVC conduit/casing capping in existing sunken pressed steel terminal boxes, providing new 3 mm thick plastic laminated sheet top cover including 1.5 sqmm PVC insulated, unsheathed, multistranded copper conductor cable as earth wire in green colour and making good the disturbed surfaces in cement mortar (1:3), complete all as specified & directed for light point controlled by one switch complete.
All as per item No 10 above, but for one ceiling/exhaust fan point controlled by one switch and regulator.
All as per item No 10 above, but for for bell point controlled by one bell push
All as per item No 10 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets
All as per item No 10 above, but for for 3 pin 5 Amp socket outlet independent complete.
All as per item No 10 here -in- before but point wiring with 4 sqmm multi stranded conductor cable and 2.5 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board all as specified and as directed by Engr-in-Charge.
Supply & fixing switch piano type flush button single pole one way 5/6 Amps, 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing in repairs switch piano type flush button single pole one way 5/6 Amps, 230 volts including taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button single pole one way 15/16 Amps 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing in repairs switch piano type flush button 15 Amps, 230 volts including taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet 2 in 1, 5 Amp, flush type all as specified & directed by Engineer-in- charge.
Supply & fixing in repairs socket outlet 2 in 1, 5 Amp,flush type including taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type all as specified & directed by Engineer-in- charge.
Supply & fixing in repairs socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type ncluding taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing bell push flush button 5/6 Amps, 230 volts all as specified & directed by Engineer-in- charge.
S & F in repair sheet metal single pole and neutral enclosure 240 volts with a two pin and earth plug and socket complete with 20 Amp single pole MCB complete all as specified and as directed by Engr-in-charge.
S & F Lamp holder insulated body with back plate etc including LED lamp 9 watt, all as specified and as directed by Engr-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 mm x 50 mm size, 3 terminals complete all as specified and directed by Engineer-in-Charge.
S & F fan regulator electronic socket type 80/100 watt all as specified and as directed by Engr-in-charge.
M & L in repair fan regulator electronic socket type 80/100 watt including taking down old one complete all as specified and as directed by Engr-in-charge.
Supply & fixing electric bell ding dong 230 volts AC supply all as specified and directed by Engineer-in-Charge.
M& L in repair electric bell ding dong 230 volts AC supply including taking down old one complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replair batton integrated LED light fitting 1x18/20 PVC composit type T-5 tube pre wired for LED tube fixed to roof/ceiling /wall with necessary PVC blocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete Make HPL cat Pt No HLPT51520/Polycab Cat Pt No LD00103017 or equivalent of /Bajaj/Crompton /Havells all as specified and directed including taking down old one.
Supply and fix in repair bulk head fitting with LED of 10 watt complete all as specified and as directed. Make HPL Cat Pt No HLPLEDBH10w or equivallent in crompton/Havells.
Supply and fix Switch socket combination 2 in 1, 5 A flush typecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 A flush type including taking down old onecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 including taking down old one complete all as specified and as directed.
Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module including taking down old one complete all as specified and as directed.
Supply and fix in repair modular Socket, 6A/16A - 2/3 pin combined 2 module including taking down old one complete all as specified and as directed.
Supply and fix in repair modular Modular switch 1 way 6 A, 1 module including taking down old one complete all as specified and as directed.
Supply and fix in repair modular Modular switch 1 way 16 A, 1 module including taking down old one complete all as specified and as directed.
Supply and fix in repair modular Fan step regulator, 120W - 2 module including taking down old one complete all as specified and as directed.
S & F in repair factory made sheet metal distribution boards, SPN, 12 way double door; protection class IP-30 suitable for mounting MCB/ conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, SPN, 8 way; double door; protection class IP-30 suitable for mounting MCB/ MCCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, SPN, 4 way; double door, protection class IP-30 suitable for mounting MCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge. Make Legrand / Havells/L&T.
S & F in repair factory made sheet metal distribution boards, double door TPN, 4 way; protection class IP-30 suitable for mounting MCB conforming to IS- 8623 with 63Amps rated copper bus bar suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in- charge.
S & F in repair MCB tripple pole 63 Amp, 415 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge. MakeLegrand / Havells/L&T.
S & F in repair MCB SPN 63 Amp, 240 Volts, rupturing capacity 10 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge. Make - Legrand / Havells/L&T.
S & F in repair MCB SPN 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge. Make Legrand / Havells/L&T.
S & F in repair MCB SP 6 to 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge. Make Legrand / Havells/L&T.
S & F in repair MCB tripple pole & Nuetral 63 Amp, 415 Volts, rupturing capacity 9 KA complete all as specified and directed by Engr-in-charge. Make Legrand / Havells/L&T.
Sub main wiring with two single core PVC sheathed insulated cable of 6 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 25 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor. (Two run of single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length) complete all as specified and directed by Engineer-in-charge.
Sub main wiring with Four single core PVC sheathed insulated cable of 10 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 32 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal boxes and accessories such as tees, bend elbows, reducers, bell mouth tube ends fixed concealed in wall including one run of 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor. (four run of 10 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length) complete all as specified and directed by Engineer-in-charge.
S & F 1100 volts grade heavy duty PVC insulated aluminium stranded conductor cable served with inner sheathing twin core flat or circular of size 10 sqmm in service connection & suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire all as specified & directed by Engineer-in-charge.
S & F LED building security light fitting 25 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one.Make of fitting Bajaj Cat Pt No BRLEP 25 W LED or equivallent in Crompton/Havells.
M&L for repair to door hinges of sheet metal cabinet of 22 SWG of CRCA of size 660 mm x 660 mm x 200 mm icluding necessary welding and painting the cabinet with two coat of synthatic enamelled paint over a coat of red oxide primer and reaarangig all elctrical connection in the box complete all as specified and as directed.
Supply and fixing MS sunken box 1.2 mm thick and min 60 mm deep including making good the disturbed surfaces with cement mortar complete all as per existing sizes.
Supply and fixing bakelite hylem sheet of size as per existing switch board and tightening with brass screw and cup washers complete all as specified
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .