| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.8 L+₹28,044 (11.3%)Rejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.8 L+₹28,966 (11.7%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹3.0 L+₹48,724 (19.6%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹3.0 L+₹51,860 (20.9%)Rejected-Finance H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | L5 | Rejected-Finance L5 |
Tender Value
₹3.3 L
EMD Value
₹6,600
Closing Date
5 Mar 2021, 5:00 pmClosed
EXECUTIVE ENGINEER ELECT PWD B AND R HISAR
EXECUTIVE ENGINEER ELECT PWD BAND R HISAR
CONSTRUCTION OF NEW BUS STAND AT BALSAMAND IN DISTT. HISAR. (PDG. HIGH MAST LIGHT ONLY).
2021_HRY_160607_1
WD/Elect-GGN/Elect-HSR/100126
Open Tender
Electrical Works
Works
120 days
HISAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹6,600
11 May 2021
23 Feb 2021
8 Mar 2021
23 Feb 2021
5 Mar 2021
23 Feb 2021
Amount
Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). xiv) Triple pole switch with neutral link 32 amp. 415 Volts Cat-B.
Miniature Circuit Breaker and Isolator: Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17). Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
vi) TP MCB 6 amp. to 32 amp.
v) TPN MCB 6 amp. to 32 amp.
Pipe Laying: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21). xiii) Galvanized iron pipe 50 mm dia on flushed.
(Q) Earthing (HSR 31.22). i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
xix) Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. staples of same size.
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. (HSR 31.25). xli) 25 Sq. mm 4 Core Ard. Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26). xli )25 Sq. mm 4 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28). ii) 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40). i) Cable size 1.5 sqm(3/0.81 mm)
S/E of double door sheet steel enclosure distribution board suitable for MCCb and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.41). v) 4-way,TP&N (Horizontal)(8+12)
Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.67). i) HDPE pipe 63/50 mm outer dia/ inner dia
Supply, installation, Testing and commissioning of 12.5 Mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 6 Nos. Luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer-in-Charge. (HSR 31.83). Thickness of Top Section = 3mm (Minimum) Bottom Section =3mm (Minimum) Top Dia = 150mm Bottom Dia = 360mm Thickness of Galvanization Top = 65micron (Min.) Bottom = 85niicron (Min.) Bottom = 85micron (Min.)
Non Schedule items: S/E of 150 W LED Flood light luminaries with high power LED Minimum 110 lumens per watt Luminaries with secondary optics made in pressure die cast aluminum housing and Heat sink in aluminum extrusion with IP-65/66 with front toughened glass including the all petty material & labour for errection, complete in all respect of upto the entire satisfaction of the Engineer-in-Charge of the work. Make: Philps/ Wipro/Crompton.
Non Schedule items: Supply and erection of 63 Amp. 3 Phase automatic time switch of L&T make alongwith contactor of required capacity of L&T/ Indoasian/ C&S make movement controlled by precisaty quartz osciliation operation on main supply of continue to run on built in rechargeable nickel cadium cell for 150 hours in the event of power failure including cost of contractor complete in all respect upto the entire satisfaction of Engineer-in-charge of the work.
Non Schedule items: S/E of 0.3 KVA capacity invertor with SMF battery for aviation light in existing panel including the cost of all labour & material for connection and petty material etc. to complete in all respect upto entire satisfaction of the Engineer-in-Charge of the work.make of Invertor -Microtec, Sukam, Luminous Battery make - Exide, Amron
Non Schedule items: Const. of R.C.C Foundation for 12.5 Mtr. High Mast Pole of size as per approved / attached drawing including the cost of cement / concerte/ longitudinal MS reinforcement rods with rings/ foundation bolts / Anchor plates & other allied material etc as per approved drawing and design to complete the job. The rates are including the cost of suitable size of digging / boring of pit for excavation of foundation below the ground level and also fixing / installation/ connection/ testing / commissioning/ errection of High mast pole on the foundation with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work.(Detailed Attached).
pawan Kumar
Chopta Offset Printers
M/s JSB Enterprises
M/S NATWADIA ELECTRICAL COMPANY
GALAXY ELECTRIC SOLUTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .