Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | ₹22.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹23.9 L+₹1.6 L (7.31%)Rejected-AOC | ₹23.9 L+₹1.6 L (7.31%) | L2 | Rejected-AOC L2 |
Tender Value
₹25.3 L
EMD Value
₹50,640
Closing Date
27 Nov 2023, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
SPECIAL REPAIRS TO BUILDING NO T-48 AT AFS YELAHANKA AND PROVISION OF DUST FREE ENGINE BAY AT DORNIER TECH FLIGHT AT AF STATION YELAHANKA
2023_MES_624930_1
8195/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹50,640
Yes
28 Dec 2023
25 Oct 2023
4 Dec 2023
25 Oct 2023
27 Nov 2023
8 Nov 2023
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. all as directed.
M&L for precast cement concrete block masonry in 1:3:6, type C-1 (using 20mm graded stone aggrerate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed.
M&L for Providing precast reinforced cement concrete, type B1 (using 20mm graded stone aggregate) as in lintels and like and setting in cement mortar 1:4 all as specified and directed. Note : Reinforcement shall be measured and paid separately.
Use & Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and as directed
S&F of rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. in Fe 410-W (Gde-E-250) quality-A all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dence soil all as directed.
Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise for superficial area exc 500 Sqcm but n exc 0.1 Sqm all as directed.
M&L for Plain Cement concrete, type B-2, 1:2:4 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for Providing, cement concrete, type C-1, 1:3:6 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, except kerbs and mud stops , water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary fromwork complete all as specified as directed
M&L for 50mm thick, Plain Cement concrete, type B-1, 1:2:4 (using 20mm graded stone aggregate) as in flooring and pavement and surface finished fair and even including Use and waste of form work/screed strips and to divide the area in panels complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instructions, finished even and smooth without using extra cement complete all as specified and directed. Note:- supply only of water proofing compound will be measured and paid seperately under relevant item.
S&F for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete as as specified and as directed
S&F Anodised aluminium snap grid of Size of grid 605 x 605mm, frame work for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete including 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with screws to aluminium framework on snap grid complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 06 to 08mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of internal walls and applying two coats of oil bound distemper, white or tined including one coat of alkali reristant priming paint complete all as specified and directed.
M&L for preparing new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F of Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, minimum thickness of powder coating 50 micron complete all as specified and directed
S&F of Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. minimum thickness of powder coating 50 micron complete all as specified and directed
S&F of Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) minimum thickness of powder coating 50 micron complete all as specified and directed.
S&F of Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. minimum thickness of powder coating 50 micron complete all as specified and directed
S&F of 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane including solar control film 25 micron recflective type sticked to glass pnes as per instructions for manufactures all as specified and directed.
S&F of Aluminium anodised, barrel tower bolts 200mm long of extruded section complete all as specified and directed.
S&F of Aluminium anodised, barrel tower bolts 100mm long of extruded section complete all as specified and directed.
S&F brass mortice lock, vertical type, size 65 mm, 4 lever fixed complete all as specfied and directed.
S&F of 5mm thick Rubber sheet with fabric backing or insert and plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive complete all as specified and directed
M&L for Complete removal of existing treatment on walls all as specified and directed
M&L for applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed
M&L for finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and directed.
Demolition of Cement concrete (un -reinforced) of any description and in any position not otherwise specifically provided for all as directed.
Demolition of Brick work built in cement mortar complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings all as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc all as directed.
M&L for Brickwork with old size bricks, subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L reinforcement cement concrete 1:2:4 Type B1 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for 25 mm thick, plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in flooring and pavements, surface finished fair and even complete all as specified and directed..
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L only for Mirror polishing on existing flooring of marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for 20mm thick screed bed or bedding layer in cement mortar(1:4) for laying floor finishes all as specified & directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete work in CM 1:3 for receiving of wall tiles complete all as specified and directed
M&L 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed.
M&L Glazed Coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
Taking down chowkasts or frames of size exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frames) and refixing in the same opening complete all as specified and directed.
Taking down chowkasts or frames of size n exc 1.5 Sqm each with shutters (without taking off shutters from the frames) and refixing in the same opening complete all as specified and directed.
S&F second class hard wood, Plain, solid, straight chowkats and frames,wrought,framed rebated on the solid or chamfered,put together with glue pinned at joints all as specified and directed.
M&L for preparing surface of wood and wood based materials,new or old,treating ends of posts, backs of chowkats,etc treated with tar or coal tar black paint area tarred exc 0.1 sq.m but n. exc 0.5 sq.m each complete all as specfied and directed.
S&F mild steel bands, straps,clamps, hold fast,wall ties,cleats & small articles, supports or stays for rainwater,ventilating pipes, including bolts , plate washers and similar items etc conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&Lfor preparing surface of steel and iron materials,new or old, such as hold fast, clamps,stops,covers,gully gratings,ends of posts, backs of chowkats,etc. treated with tar or coal tar black paint area tarred n.exc 0.1 sq.m each complete and directed.
S&F mild steel framed work such as grills, gratings, etc. .shouldered and/or riveted,or forged into spikes; framed guard bars;barred iron doors;ladders; framed balusters; wall ways; railings; framework of water tanks and similar work conforming to Fe .290.Gde-E-165 complete all as specified and directed.
M & L plain cement concrete 1:2:4 type B1 (using 20 mm graded agg.) as in hold fast block including necessary form work complete all as specified and directed.
S&F 35mm thick second class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats all as specified and directed.
S&F 25mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain,chamfered or rounded,mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified , and fitted to chowkats all as specified and dircted.
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty/wooden beads, in square n exc 0.5 sq. m in each pane all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 100mm size and fixed all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, 75mm size and fixed all as specified and directed.
S&F mild steel barrel tower bolts, 200mm long,stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F mild steel barrel tower bolts, 100mm long,stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F Mild steel sliding door bolts,300mm long plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed.
S&F mild steel pressed handles,125mm long, oval type, stove enamelled black all as specified and directed.
S&F mild steel pressed handles,100mm long, oval type, stove enamelled black all as specified and directed.
S&F mild steel wire, type-I Gate and shutter, hooks and eyes of size 75mm all as specified and directed.
M&L second class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each all as specified and directed.
M&L for preparation of new / previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for complete removal of existing treatment on plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3mm thick wall care putty on internal surface of walls all as specified and directed.
M & L Complete removal of existing treatment on plastered surfaces and applying two coats of cement based paints over a coat of alkaline resistant primer on walls complete all specified and directed.
M&L for 15mm thick rendering on brick wall with CM 1:6 and finishing the surface even & fair without using extra cement complete all as specified.
M&L for preparation of new or previously untreated surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer paint complete all as specified and directed.
M&L for preparing old steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of Synthetic enamel paint complete all as specified and directed.
M&L for preparation of old treated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F fixed in repairs for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F for 15mm bore GI tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified and directed.
S&F for 15 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F for 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F of 75mm dia bore PVC (SWR) bends any radius complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as directed.
S&F of mild steel framed brackets for chajja of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') all as specified and directed.
S&F in repairs stainless steel kitchen sinks with drainage board 1mm thick with pluges, washers and wasters,including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F of 15 mm dia bib taps, long neck, fancy type, cast copper alloy,with capstan heads,chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and flfnuts,screwed for iron pipe complete all as specified and directed.
S&F of Waste coupling 40mm dia of PTMT (half threaded) minimum weight 60 gms suitable for WHB & Sink complete all as specified and directed.
M&L for point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI marked unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through in stove enamelled steel conduit of required size with all accessories fixed to the surface of walls/roof/ floors / ceiling etc, M S terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed copper conductorMuistandere FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly. for one light/ Fan point controlled by one switch complete all as specified and directed.
All same as per item No 87 above but wiring with 2.5 sq mm FRLS copper cable including earth continuty conductor with 2.5 sq mm FRLS copper cable for one 16 Amps flame proof switch socket combination outlet on independent board controlled by 16 Amps switch complete all as specified and directed.
M&L for point wiring complete with 3 run of 4.00 sqmm single core PVC insulated heavy duty ISI Marked, FRLS, unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including rigid PVC conduit not less than 20mm dia and conduit accessories concealed/fixed to walls/roofs/floors/ceiling etc., and connected to common earth dolly for 32 Amps three phase Metal clad socket complete all as specified and directed
S&F ceiling rose surface bakelite 65x50mm 3 terminals compete all as specified and directed by Engr-in-Charge.
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 6/16A, 250V, 2P+earth compete all as specified and directed by Engr-in-Charge.
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth compete all as specified and directed by Engr-in-Charge.
S&F LED luminaire 600mmx600 mm, 36 watt, 220 V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
S&F flame proof ceiling fan 1200 mm sweep, not less than 900 RPM, single phase 230 Volts AC 50 Hz, 3 blades, air delivery not less than 65 CFM complete and directed by Engr-in-Charge.
S&F flame proof fan speed regulator, electronic step type, not less than 3 step, suitable for single phase AC, 240 volts, 50 Hz, 100 watts all as specified and as directed.
M&L for sub-main wiring with three runs of 6 sqmm unsheathed PVC insulated, single core FRLS cable with copper stranded conductor drawn through and including suitable dia steel conduit conduit and conduit accesories fixed to wall/roof/floor and including 6 sqmm copper FRLS earth wire and making good to the distrubed surfaces also matching the existing surfaces all as specified and directed by Engr-in-charge. Note: 3 runs of cable and one run earth wire and conduit will be measured as one Unit.
S&F air curtain of size 1200mm x 230mm x 212mm, MS Powder coated body, air velocity 21m/s, RPM min-2100/2700 power consumption not more than 560 watts, single phase 230V, air delivery not less than 1100 CFM, noise level not more than 70 db, ABS body 4 Nos of blower, 02 Nos of motors complete all as specified and directed by Engr-in-Charge. Make: Euronics, Model No : EAC 4 or its equivallent.
S&F sheet metal enclosures for MCB distribution board 240 Volts single pole and neutral 12 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
S&F MCB Triple pole and Neutral, 415 volts, 40 to 100 Amps, 'C' Curve, 10 KA, complete all as specified and as directed by Engr-in-charge.
S&F MCB SPN 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity complete all as specified and as directed by Engr-in-charge.
S&F MCB SP 5 to 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity complete all as specified and as directed by Engr-in-charge.
Supply, install, testing and commissioning of 2 TR capacity hi wall split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity complete all as specified and as directed by Engr-in-charge including the following : (a) New copper piping of size 1/4' with insulation -- 5 Mtr . (b) New copper piping of size 3/8' with insulation of expanded polythene foam- 5 Mtr. (c) Communication cables - 6 Mtr. (d) Drain water piping - 5 Mtr.
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth all as directed.
Dismantling and taking down old unserviceable service cable of any size/type all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as directed by Engr-in-Charge.
Returning filling in excavated soil upto a depth of 30cm after riddling excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil complete all as directed.
Supply and laying in trenches, floors, roof, ducts, LT underground cable of size 3.5 core 25 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc. and fixing using clamps, saddle for pole, wall etc complete all specified and directed.
M& L for Boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 40 mm dia suitable for 0.4mpa working pressure complete all as specified and directed by Engr-in-Charge.
Taking down carefully old unserviceable aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc, removing materials to store, or keeping in safe custody for re-use at site or offering credit,& making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Taking down carefully old unserviceable MBC DBs/metal clad sockets and offering credit including making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Taking down ceiling fan, dismantling blades and removing fan and refixing ceiling fan after completion of re-wiring, and connecting up including provision of cable from ceiling rose or connector to fan all as directed.
M & L for Painting of Ceiling fans complete, in site with synthetic enamel paint by spraying including filling caviteis with filler, one coat after cleaning all dust etc all as specified and directed.
Point wiring completed with 1.5 sqmm single core PVC insulated heavy duty ISI Marked unsheathed FRLS copper conductor cable 1100 volts grade with multistranded copper conductor drawn through concealed PVC conduit medium grade and including provision of PVC Insulated heavy duty ISI marked Unsheathed FRLS copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and directed. for the following: -
(a) One light point controlled by one 5 Amps switch
(b) One switch socket outlet point 3 pin 5 Amps on same board with other switches.
(c) One ceiling fan controlled by one switch
(d) One socket 5 amp on independent board.
All as per item No 116 above but wiring with 2.5 sq mm copper cable with 2.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out controlled by 15 Amps switch all as specified and directed.
S&F switch piano 6 Amps flush type one way all as specified and directed.
S&F switch socket outlet 5 pin 5 Amps multi pin flush type all as specified and directed.
S&F of 5 Amps Switch socket combination 5 Pin all as specified and directed.
S&F switch socket combination 3 Pin, 6/16 Amps multipin flush type all as specified and directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and directed.
S&F in repair stepped type electronic regulator flush type suitable for single phase AC, 240 volts, 50 Hz, 100 watts all as specified and as directed by Engr-in-Charge.
Supply and fix LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Eng-in-Charge.
M&L for sub-main wiring with four runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 4 sqmm copper earth wire, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 3 runs of cable and one run earth wire and conduit will be measured as one length or one Meter. Note : 4runs of cable, one run of earth wire and conduit will be measured as one unit.
Supply and fix of metal clad socket outlet with Triple pole with three pin plug socket complete with one triple pole MCB 32 Amps 'C' Curve, 415 Volts, 10 KA rupturing capacity complete all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 415 Volts triple pole and neutral 4 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 240 Volts single pole and neutral 8 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 240 Volts single pole and neutral 4 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MCB TPN 63 Amps, 415 Volts, 'C' Curve, 10 KA rupturing capacity all as specified and directed.
Supply and fix MCB TPN 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity all as specified and directed.
Supply and fix MCB SPN 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity all as specified and directed.
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Mahant Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .