| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC L1 Amount rate |
Tender Value
Refer Docs
EMD Value
₹41,558
Closing Date
18 Jan 2017, 3:00 pmClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Renovation of existing GYNEE DEPARTMENT (Gr. Fl,1st fl, 2nd fl, and 3rd fl. at Burdwan Medical College and Hospital, Burdwan Supply,Installation,Testing and Commissioning of Fire Detection and Alarm System.
2017_WBPWD_97509_1
WBPWD/SEWEC/BED /NIQ-71/2016-17 (4th Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
BURDWAN
Please refer Tender documents.
4 documents required · 4 mandatory
₹41,558
Yes
13 Feb 2020
10 Jan 2017
19 Jan 2017
10 Jan 2017
18 Jan 2017
10 Jan 2017
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based 4 Loops expandable up to 8 Loops fire alarm control panel ( EN Standard, VDS / UL / FM/ ULC approved ) fully networkable with each loop capable of taking minimum 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in it's Memory.The Panel should have hotstand by redundant Microprocessor in CPU loop Card and networking Card. “1/4 VGA display Character alpa- numeric liquid crystal display “" to "5.7" TFT LCD color display."
The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required. The system must be preloaded licenced software. (Approved Make: Secutron/ Notifer / Edward / Bosch ).
SITC of Repeater Panel ( EN Standard VDS / UL/FM/ ULC approved ) which will act as an add-on device for remote display of FACP status information of the FDA operating front related to the detectors and decetors zones Event messages are displayed via LED collective indicators and on the 2-Line LCD display with the associated detecors zone number and a programmable additional text Each message is signalled via the built-in buzzer The buzzer can be acknowledged by pressing a button Upto 31 LCD indicator panel can be operated on as RS 485 bus (Approved Make: Secutron/ Notifer / Edward / Bosch ).
Supply, installation,Testing & Commisionmg of Analog Addressable Intelligent multisensor detector { EN Standard VDS / UL / FM/ ULC approved ) with inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base as required(Approved Make: Secutron/ Notifer / Edward / Bosch ). (Note . Detectors without built-in fault isolator is a also acceptable but in such case the contractor shall provide one independent fault isolator module for every twenty addressable devices without any additional cost)
Supplying installation, testing and commissioning of Addressable Heat Detector ( EN Standard. VDS / UL FM/ ULC approved ) (Fixed temperature cum rate o rise) with twist lockable removal base built - in fault isolator drift compensation feature etc including connections as per specifications complete as read.(Approved Make: Secutron/ Notifer / Edward / Bosch )..(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every twenty addressable devices without any additional cost)
Supply Installation,Testing & Commisionmg of Addressable Manual Call Point ( EN Standard. VDS / UL / FM/ ULC approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required(Approved Make: Secutron/ Notifer / Edward / Bosch ).
Supply. Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( EN Standard VDS / UL /FM / ULC approved ) (sound output of minimum 90 db )cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS EN-54 UL I FM / ULC approved) approved (Approved Make: Secutron/ Notifer / Edward / Bosch ).
Supply, Installation Testing & Commissioning of Addressable transponder/ Monitor Modules ( EN Standard. VDS / UL / FM/ ULC approved ^ monitoring flow switches/Fire exit doors / AHU Lift etc complete as required (Approved Make: Secutron/ Notifer / Edward / Bosch ).
Supplying, installation, testing and commissioning of LED type Response Indicator ( EN Standard VDS / UL / FM/ ULC approved )having 1 No red coloured LED lamps including connections etc. (Approved Make: Secutron/ Notifer / Edward / Bosch ).
Supply, Installation, Testing & Commissioning of Power supply 230 V AC to 12 V DC with all other accessories. (Make: Reputed)
Supply & Laying of 2 Core 1 5 sq.mm FRLS shielded un armoured copper Cable (For Loop) (Make Finolex / Polycab ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium/Pestro plast medium) ^ on the surface of the wall.
S & F 40mm dia Gl pipe bracket (1.5 mtr long) with two nos. Clamping arrangement for fixing of bracket on wall
Add Service Tax as applicable
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .