| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC 6 51 OLD POST OFFICE LANE UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹28.5 L Quoted ₹29.5 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹32.1 LRejected-Finance | ₹32.1 L | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹34.6 LRejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹34.6 L | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹37.9 LRejected-Finance H O 20 D INDUSTRIAL ESTATE LEH LADAKH 194 101 J K | LEH | LEH | LADAKH | 194101 | ₹37.9 L | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹46.6 LRejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | ₹46.6 L | L5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | MS INFRATECH L4 | EESSI L5 | M/s Raj Construction L2 | KASHMIR FAIR DEAL SERVICES L3 | M/S MAHALUXMI BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down defective/ unserviceable LED street lights fitting and flood lights of any type and of any description and capacity from 09/11 high electric pole and gates and fixing after repair of old or new light fitting in his position or complete all as specified and as directed.
Note:
(i) light fittings/Spare parts shall be measured and paid separetly.
(ii) The T&P vehicle and necessary ladder etc will be arranged by the contractor and thecost deemed to be included in the quoted rates.
(iii) The contractor bound to provide 01 Electrician and 01 helper for carry out the complaint of street light as and when required
(iv) if contractor not attending complaint within two days after per day Rs1000 recovery from RAR shall be done till complaint attended. | 153 | Per Job | 160 ₹24,480 | 500 ₹76,500 | 150 ₹22,950 | 130 ₹19,890 | 20 ₹3,060 |
| 2.00 | S & F in repair of existing LED Street light 30/35 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed. | 20 | Each | 400 ₹8,000 | 2,000 ₹40,000 | 300 ₹6,000 | 290 ₹5,800 | 350 ₹7,000 |
| 3.00 | S & F in repair of existing LED Street light 50/60 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed. | 15 | Each | 600 ₹9,000 | 3,000 ₹45,000 | 500 ₹7,500 | 600 ₹9,000 | 350 ₹5,250 |
| 4.00 | S & F in repair of existing LED flood light 70/100 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed. | 7 | Each | 500 ₹3,500 | 3,700 ₹25,900 | 600 ₹4,200 | 650 ₹4,550 | 465 ₹3,255 |
| 5.00 | S&F in replacement LED street light fitting made up of pressure die cast aluminium housing with high efficiency LED 30/35 watt sealed optic luminaire, indivdual optical lens LED embedded PC cover having bottom opening seperate driver compartment with IP66 protection complete all as specified and as directed. | 35 | Each | 3,000 ₹1.1 L | 3,400 ₹1.2 L | 2,600 ₹91,000 | 2,900 ₹1.0 L | 2,610 ₹91,350 |
| 6.00 | S&F in replacement LED street light fitting made up of pressure die cast aluminium housing with high efficiency LED 60/70 watt sealed optic luminaire, indivdual optical lens LED embedded PC cover having bottom opening seperate driver compartment with IP66 protection complete all as specified and as directed. | 55 | Each | 4,000 ₹2.2 L | 4,000 ₹2.2 L | 3,400 ₹1.9 L | 3,700 ₹2.0 L | 2,920 ₹1.6 L |
| 7.00 | S&F in replacement 70 Watt High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. High lumen efficacy LED module with SMD LED package mounted with PC lens , suitable for highlighting architectural facade etc complete all as specified and as directed. | 14 | Each | 6,500 ₹91,000 | 4,500 ₹63,000 | 5,500 ₹77,000 | 6,600 ₹92,400 | 4,200 ₹58,800 |
| 8.00 | S&F in replacement 100 Watt High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. High lumen efficacy LED module with SMD LED package mounted with PC lens , suitable for highlighting architectural facade etc complete all as specified and as directed. | 7 | Each | 7,500 ₹52,500 | 5,000 ₹35,000 | 6,500 ₹45,500 | 6,000 ₹42,000 | 6,200 ₹43,400 |
| 9.00 | S&F in replacement MCB DB SPN 2 way sheet metal enclosures complete all as specified and as directed. | 15 | Each | 1,200 ₹18,000 | 1,000 ₹15,000 | 1,100 ₹16,500 | 1,500 ₹22,500 | 310 ₹4,650 |
| 10.00 | S&F in repairs PVC non rigid conduit 20mm dia with fixing accessories from existing junction box to light fitting complete all as specified and as directed. | 100 | RM | 20 ₹2,000 | 100 ₹10,000 | 60 ₹6,000 | 70 ₹7,000 | 55 ₹5,500 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 May 2026, 6:00 pmClosed
GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR, REPLACEMENT LED STREET LIGHTS, PERIMETER LIGHTS, SOLAR LIGHTS FITTINGS AND ALLIED WORKS AT SASOMA AND BASE CAMP AREA UNDER GE 873 EWS
2026_MES_757918_2
GE/873/EWS-37/2026-27
Open Tender
Civil Works
180 days
GE 873 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 873 EWS
₹70,000
Yes
8 May 2026
20 Apr 2026
4 May 2026
20 Apr 2026
2 May 2026
25 Apr 2026
S & F in repair of existing LED Street light 30/35 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed.
S & F in repair of existing LED Street light 50/60 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed.
S & F in repair of existing LED flood light 70/100 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed.
S&F in replacement LED street light fitting made up of pressure die cast aluminium housing with high efficiency LED 30/35 watt sealed optic luminaire, indivdual optical lens LED embedded PC cover having bottom opening seperate driver compartment with IP66 protection complete all as specified and as directed.
S&F in replacement LED street light fitting made up of pressure die cast aluminium housing with high efficiency LED 60/70 watt sealed optic luminaire, indivdual optical lens LED embedded PC cover having bottom opening seperate driver compartment with IP66 protection complete all as specified and as directed.
S&F in replacement 70 Watt High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. High lumen efficacy LED module with SMD LED package mounted with PC lens , suitable for highlighting architectural facade etc complete all as specified and as directed.
S&F in replacement 100 Watt High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. High lumen efficacy LED module with SMD LED package mounted with PC lens , suitable for highlighting architectural facade etc complete all as specified and as directed.
S&F in replacement MCB DB SPN 2 way sheet metal enclosures complete all as specified and as directed.
S&F in repairs PVC non rigid conduit 20mm dia with fixing accessories from existing junction box to light fitting complete all as specified and as directed.
S & F for PVC insulated aluminium stranded conductor of size 10.0 sq.mm twin core flat or circular cable 1100 volt grade, heavy duty cable, served with inner sheathed cable complete all as specified and directed.
S & F for PVC insulated aluminium stranded conductor of size 4.0 sq.mm twin core flat or circular cable 1100 volt grade, heavy duty cable , served with inner sheathed cable complete all as specified and directed.
Supply and fix in replacement MCCB, 415 volts, 4 pole 25 KA, 63/100 Amps adjustable thermal setting as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply and fix in replacement MCCB, 415 volts, 4 pole 36 KA, 160A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply and fix in replacement MCB, 415 volts,TPN 10 KA, 25 to 40A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
Supply and fix in replacement MCB, 220 volts, SPN 10 KA, 6 to 20 Amps complete all as specified and directed.
Supply and fix in replacement MCB, 220 volts, SP 10 KA, 6 to 20 Amps complete all as specified and directed.
S & F in replacement MCCB 63 Amps 4 pole with sheet metal enclosures box complete all as specified and directed.
M&L for straight through jointing kit heat shrinkable type for LT UG XLPE armoured cable 1100 volt grade of size 10 sqmm to 16 sqmm complete all as specified and as directed.
M&L for straight through jointing kit heat shrinkable type for LT UG XLPE armoured cable 1100 volt grade of size 25 sqmm to 50 sqmm complete all as specified and as directed.
M & L for searching fault by mannualy /Machine of 16 sqmm to 70 sqmm unservieable LT underground cable 1100 volt grade after tracing out defect i.e. cutting and jointing cable with suitable size straight through joint and after testing with megger etc. complete all as specified and as directed. Note for Item No 15 to 18 (a) If extra suitable size cable required for straight through jointing (the extra cable required length upto 3 RM) rate shall be deemed into this item rate. (b) Earth work more than two running meter shall be measured and paid separately . (c) Straight through joints will be measured and paid separately. (d) If not attending complaint within two hours or not rectification of complaint same day if noticed the recovery shall be made Rs 2000/- per day from contractor bill till complete the job.
M & L for repair of LT Panel by replacing damaged door hinges set of front and back side, fixing sliding door lock chromium plated and necessary cutting, welding drilling hole etc. required at site for making good to LT panel complete all as specified and directed.
S&F in replacement of digital Volt meter (0-500) including connections and testing complete all as specified and directed.
S&F in replacement of digital ammeter including connections and testing complete all as specified and directed.
S&F in replacement of Indicating Lamp R. Y. B (LED) Type including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of CTs of required rating including connections and testing complete all as specified and directed.
Supply and fix in repairs aluminium cables lugs for cables of size up to 10 Sqmm to 50 sqmm including necessary crimping with crimping tool complete all as specified and as directed.
Supply and fix in repairs aluminium cables lugs for cables of size up to 95 Sqmm to 300 sqmm including necessary crimping with crimping tool complete all as specified and as directed.
Disconnecting, and taking out old unserviceable , LT UG XLPE insulated aluminium conductor PVC sheathed 1100 volts grade armoured cable of size 10 to 25 Sqmm of any core from trench / duct/ wall complete all as directed. Note:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule complete all as specified and as directed.
All description as per Serial item No. 29 above but for cable size 35 to 70 Sqmm of any core
Laying only serviceable existing 10 Sqmm to 25 Sqmm any core LT UG XLPE insulated armoured cable and PVC sheathed 1100 volts grade in new or old position complete all as specified and directed. (NOTE for item No 31 to 32 : (i) Old retrieved cables received from item No 29 to 30 in serviceable condition from taking down shall be used in the work (ii) Additional quantity of cable, if any required, for replacing the defective portion of cable shall be measured and paid separately under respective items.
All description as per Serial item No. 31 above but for cable size 35 to 70 Sqmm of any core
Supply, laying and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 10 Sqmm 4 Core complete all as specified and as directed.
All description as per Serial item No. 33 above but cable of size 16 Sqmm 4 Core
All description as per Serial item No. 33 above but cable of size 25 Sqmm 4 Core
All description as per Serial item No. 33 above but cable of size 35 Sqmm 3.5 Core
All description as per Serial item No. 33 above but cable of size 50 Sqmm 3.5 Core
All description as per Serial item No. 33 above but cable of size 70 Sqmm 3.5 Core
Excavation in hard/ dense soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable complete all as specified and as directed.
Returning filling using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms complete all as specified and as directed.
Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete all as specified and as directed.
S & F in replacement of 40 mm dia GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position complete all as specified and as directed.
Supply and laying 50 mm outer dia HDPE pipe (DWC) Double wall corrugated outer surface and smooth inner wall, ISI marked and as per IS : 16205 (part-24) or latest IS 14930 (part-II), 450N compressive strength with snap fit coupler with rubber ring for underground electrical cable protection conduits Orange colour complete all as specified and directed.
Supply and laying 77 mm outer dia HDPE pipe (DWC) Double wall corrugated outer surface and smooth inner wall, ISI marked and as per IS : 16205 (part-24) or latest IS 14930 (part-II), 450N compressive strength with snap fit coupler with rubber ring for underground electrical cable protection conduits Orange colour complete all as specified and directed.
Disconnecting existing over heated or burnt cable terminal at existing panel/ Junction box and cutting out over heated / burnt portion of cable, stretching / opening cable to suitable required length from available rings and reconnecting cable in position properly with providing new lugs, tapes etc for cable size upto 95 sqmm complete all as specified and as directed.
M & L for Reinforced cement concrete 1:2:4 type B1 ( 20 mm graded aggregate) as in Cable route indicator pillars size not less than 0.3x0.1 x0.90 mtr including use and waste of necessary formwork etc. and black colour writting of HT/ LT cable size on both side surface of each pillar as per approved pattern over of yellow synthetic enamel paint etc. and grouting complete all as specified and as directed.
Supply and fix good quality water proof, self adhesive insulation tape of 25RM and 1" width for cable insulation all as specified and as directed by Engr in Charge at site
Attending breakdown for LT Panels/ LT Cables/MCCB/Changeover Switch to check and locate / detect fault related to breakdown ccomplete all as specified and as directed. Note:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally.
M&L in repair for LT line PVC Spacers spiral type for upto four ACSR conductor complete all as specified and directed.
M & L for preparation of old painted surface of electrical panel inner and outer surface complete of size length(0.5 to 1 m) , Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing old pait and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed.
S & F in replacement off load changeover switch 4 pole, 415 volts, 100 Amps in sheet metal enclosure as per existing sample complete all as specified and as directed.
S & F in replacement off load changeover switch 4 pole, 415 volts, 63 Amps in sheet metal enclosure as per existing sample complete all as specified and as directed.
S & F in replacement side handle switch fuse unit 2 pole,230 volts, 32 Amps in sheet metal enclosure as per existing sample complete all as specified and as directed.
S & F in replacement side handle switch fuse unit TPN , 415 volts, 32 Amps in sheet metal enclosure as per existing sample complete all as specified and as directed.
S&F in replacement intrigal decorative LED bollard with opal acrylic 10 watt LED 3000K with IP 65 protection as per existing sample complete all as specified and directed. (Make of Havells model TURINBLS10WLED830PSYMTOPC or equivalet of make)
S& F in replacement decorative 50 watt, , 240 volt, 50 HZ coloured flood light , suitable for focasing of tree / buildings of capacity complete all as specified and directed
S& F in replacement spike light LED 10 watt, , 240 volt, 50 HZ , suitable for focasing of tree / buildings of capacity complete all as specified and directed. (Make of Havells model IRVINESPS5WLED830PSYMTG or equivalet of make & model)
S& F in replacement Post top lanterned 15 watt suitable for 180 volt to 280 volt complete all as specified and directed. (Make of Havells model RUBYNXTPT15WLED757PSYMTOPC or equivalet of make & model)
S&F in replacement (Saffron-White-Green) tricolour LED rope light , water proof, with adaptor ,18 meter length suitable for 180 volt to 280 volt complete all as specified and directed
S & F in replacement All in one 15 watt High Efficacy LED Solar Street Light Aluminium Extruded body, MPPT Solar Charge Controller and High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, specially progrmmed to automatically control the dimming and brightness of light (Make havells model SOLAR AIO 15 W or equivalant of make and model)
M & L for outdoor type weather proof LT street light panel with locking arrangement, made out of 2.0 mm thick CRCA sheet steel factory fabricated with powder coating with Protection Degree IP 54 including with contactor 32 A TP, time switch Digital 24 hour, MCB TPN 40 Amp Rating with by pass connection complete all as specified and directed (Make Havells model No IHXTS03060 or equivalant of model & make )
M & L for outdoor type weather proof LT street light panel with locking arrangement, made out of 2.0 mm thick CRCA sheet steel factory fabricated with powder coating with Protection Degree IP 54 including with contactor 20A DP, time switch Digital 24 hour, MCB SPN 20 Amp Rating with by pass connection complete all as specified and directed. (Make Havells model No IHXSS01020 or equivalant of model & make )
S & F in replacment weather proof SMC junction box of outside size 200mm x 150mm x 100mm including each heavy duty epoxy inulator with nut bolt for phase and neutral , MCB SPN, 6 Amps, 250 volts with 'C' curve, cable gland etc. SMC junction box fixed on pole with 25 x 4mm new GI clamp complete all as specified and as directed.
S&F timer switch Digital type 24 hours with 15 min and 30 min, 30/100 Amp contact rating 230 volts AC 50 Hzs suitable to existing sample for street lights complete all as specified and as directed.
S & F 3 pole power contactor AC 3 rating 18/25Amps Aux Contactors 2NO+2NC complete all as per existing sample complete all as specified and as directed.
Supply and fixing in repair GI/MS bracket for street light made of 40mm bore (medium grade of length 1.2 meter), bend to shape includingsuitable size flat iron clamp with nuts, bolts and washer etc. applying two coat of red oxide primer and one coat of aluminium paint complete all as specified and directed.
S & F in replacement of multi stranded copper conductor cable of size 2.5 sq.mm, 3 core including taking down of existing unserviceable one complete all as specified and as directed.
S&F in repairs FRLS PVC insulated standed copper conductor wire of 1.5 sqmm dia, 3 core from existing junction box to light fitting complete all as specified and as directed.
S & F in replacment weather proof SMC junction box of outside size 300mm x 200mm x 105mm including each heavy duty epoxy inulator with nut bolt for RYB phase and neutral , MCB SPN, 6 Amps, 250 volts with 'C' curve, cable gland etc. SMC junction box fixed on pole with 25 x 4mm new GI clamp complete all as specified and as directed.
M&L for preparation of old painted surface of steel tubular pole (upto 9 meter long above coping) with MS clamp and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint complete all as specified and as directed.
M&L for stencil cut writting of Pole Nos. black /blue colour on white background colour complete all as specified and as directed.
M & L for maintenance free GI earthing Electrode 2 mtr length shall be based on ready capsule type, Pipe-in-Cage technology concept in which, One Galvanized hollow pipe (Electrode) 50 mm dia filled with a specially developed earth enhancement material (EEM) made up of Conductive Cement, Graphite carbon powder, Sodium montmorillonite/ Sodium Bentonite Powder, Hydrous aluminum silicate etc. to reduce earth resistivity, 50kg Chemical , GI earthing Electrode buried directly in ground vertically to a depth not less than 2.0 meter below normal ground level and connected by means of galvanized bolts, nuts and washers with including necessary earth work and PVC moulded earth pit with cover and dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron or steel wire complete all as specified and as directed.
All as per Serial item No. 73 above but using 32 x 6mm GI strip
All as per Serial item No. 73 above but using 25 x 3mm aluminium strip
S & F in replacement of GI pipe 40 mm dia light grade for earth strip protection complete all as specified and as directed.
S & F in replacement of GI pipe 15 mm dia light grade for earth strip protection complete all as specified and as directed.
Supply & fix single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 using 20mm grade stone aggregate as in coping of poles including necessary form work and fair finishing to exposed surface without using extra cement complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation for stay assy, light pole, repairing of floor/paths, fencing post road cuts etc including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and as directed.
S & F in replacment steel tubular poles complete with cast iron base plate, finial taper plug bolts, nuts and screw as specified type 410 SP-31 (9.00 Mtr Long) including two coat of aluminium paint above the two coats of red oxide primer including making of strip 20cm each (Sky blue & white) up to 1400mm height with enamalled paints, bituminus black paint over bottom of pipe upto 1500mm length and also marking the pole numbers with white enameled paint complete all as specified and directed (Note. Earth work and PCC , clamps, nuts and bolts to be measured and paid for separately)
M&L in replacment of pin or shacle insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed.
M & L Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia ,fixing between the pole complete all as specified and as directed.
Dismantling of ACSR conductor, service feeder or distribution spans complete all as specified and as directed.
Fixing only old ACSR conductor, service feeder or distribution spans complete all as specified and as directed.
S & F in stringing new ACSR conductor of any size for over Head LT Line including Tightening aluminium binding wire or suitable type clamps/connector or other jointing material complete all as specified and as directed.
S & F in replacment for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Labour only for stringing, tightening two ACSR conductor and re fixing old ACSR conductor of existing HT/LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed
Labour only for stringing, tightening four ACSR conductor and re fixing old ACSR conductor of existing HT/LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed
Supply and fix Galvanised stay strand, 7/4mm for stay wire assembly complete with pole clamp, nut bolt washer,steel stay rod, plate galvanized thimble 02 Nos, loop insulators etc shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed
Repairs to existing stay assembly including tightening of stay wire, with clamps fixed to pole or by repairing to PCC coping with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site .
Supply and installed factory made, cubicle compartmentalised outdoor type LT Panel feeer pillar box, front and rear opening with locking arrangement, dust and vermin proof, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, feeder labeling, danger plates etc. and feeder pillar box grouting in suitable size PCC foundation, and connection the existing LT UG cable or new LT UG cable with new cable lugs, gland complete all as specified and directed by EIC including taking out old LT panel. The new LT panel comprising of the following switchgear & controls Incoming (a) Bus bar chamber having Main aluminium Bus bar for 3 phase and neutral not less than 300 A Capacity. (b) MCCB 4 pole, 415V with thermal magnetic release adjustable setting of Capacity 100 Amps with ruputring capacity 25 kA 01 No (c ) LED dispay 3 line Multimeter class 0.5 with suitable size CT ratio (d) LED RYB Phase indicater - 01 Set Out going (a) MCB SPN, 32 Amps - 05 Nos
Deduct Schedule of Credit of as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender37.pdf
Tender Documents • 0.83 MB
BOQ_852431.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid