| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC Being reasonable and lowest L1 | |
| 2 | L2₹28.4 L+₹1.6 L (6.02%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹28.7 L+₹1.9 L (6.95%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹28.9 L+₹2.1 L (7.95%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹29.5 L+₹2.7 L (10.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
29 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL SS BOSE, CWE
HQ CWE (AF) CHAKERI, KANPUR 208008
REPAIR MAINT OF UG CABLES INCLUDING ALLIED WORKS IN TECHNICAL AND DOMESTIC AREA AT AFS, CHAKERI, KANPUR
2020_MES_408251_1
82170/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
CHAKERI, KANPUR
Class D Cat b (ii)
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹94,000
18 Feb 2021
30 Dec 2020
5 Feb 2021
30 Dec 2020
29 Jan 2021
15 Jan 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M & L dry Ganga sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
Supplying and laying un-reinforced precast concrete cable cover, class HV type 1, flat, size 300mmx180mmx40mm complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above from the starting point complete all as specified and directed.
M&L cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width & not exceeding 30 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed .
M&L for making horizontal boring 90 cm deep below road crossing by manual method for passing of HT cable in GI pipe compelete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall in repair of GI pipe light grade of size 100 mm bore with fitting for protection of cable including taking out existing pipe complete all as specified and directed.
Taking out old existing underground XLPE aluminium conductor HT cable of size upto 240 sqmm 3 core from trenches/duct/floor/wall/ roof/under road/drain & hard standing for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed.
Supply Laying, testing and commissioning in repair of HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 sq mm 3 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed.
All as per item No 10 above but of size 120 Sqmm 3 core
All as per item No 10 above but of size 150 Sqmm 3 core
All as per item No 10 above but of size 185 Sqmm 3 core
All as per item No 10 above but of size 240 Sqmm 3 core
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV / 33 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed. (Note : The item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that he has solely responsible to arrange fault locating machine & he shall not accept any facility from the dept for the same.)
M & L in repair of straight through joint kit Heat shrinkable type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core all including testing complete all as specified and directed.
All as per item No. 16 above but of size 120-185 sqmm 3 core.
All as per item No. 16 above but of size 240-300 sqmm 3 core.
M & L in repair of End termination joint kit Heat shrinkable Indoor type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core including testing complete all as specified and directed.
All as per item No. 19 above but of size 120-185 sqmm 3 core.
All as per item No. 19 above but of size 240-300 sqmm 3 core.
M & L in repair of End termination joint kit Heat shrinkable Outdoor type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core including testing complete all as specified and directed.
All as per item No. 22 above but of size 120-185 sqmm 3 core.
All as per item No. 22 above but of size 240-300 sqmm 3 core.
M & L in repair of Straight through joint kit Heat shrinkable type with jointing material and accessories suitable for 33 KV HT XLPE armoured aluminium conductor cable of size 185-300 sqmm 3 core all including testing complete all as specified and directed.
M & L in repair of End termination joint kit Heat shrinkable Outdoor type with jointing material and accessories suitable for 33 KV HT XLPE armoured aluminium conductor cable of size 185-300 sqmm 3 core including testing complete all as specified and directed.
S&F in repair of lightening arrestor expulsion type 11 KV with all fittings, transmission class, discharge current 65 KA including fixing arrangement as required complete all as specified and directed.
M&L in repair of 11 KV DO Fuse unit Channel type with all fixing arrangement complete all as specified and directed.
M & L in repair of Aluminium conductor steel reinforced (ACSR) of 11 KV grade with existing size & length as per site requirement complete all as specified and directed.
M & L in repair of Pin type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel spindle, two galvanazed iron washer and one galvanazed nut, 150 mm height, 150 mm dia for 11000 Volts grade complete all as specified and directed. .
M & L in repair of Shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps 38x5 mm , washers, insulator bolts 20 mm dia, 150 mm height, 150 mm dia & working pressure in 11000 volts complete all as specified and directed.
M & L for earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32mm x 6 mm as earthing lead protected with 50mm dia light grade GI pipe, filling around with charcoal dust and salt including excavation, returning filling of earth work and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C-1 using 20mm graded stone aggregate and pre cast RCC cover 40 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh, 20 mm dia GI pipe light grade watering pipe and framework complete all as shown in electrical plate No 3 of SSR Part-I 2009 including testing complete all as specified and directed. Note:-GI strip beyond 7.5m length shall be measured & paid for separately.
S&F Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and directed.
Dismantling, shifting and reinstallation of dismantled HT 11 KV switch gears / VCB / Transformers etc. from sub station to a location as directed but not more than 5 Kms complete all as specified and directed.
M&L for general servicing, repair and maintenance of HT Panel board / RMU by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar, removing moisture (if any) and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth, replacement of unserviceable nuts, bolts, washers etc including replacement of corroded glands, lugs/ thimbles and tightening them properly including control wring for metering and relay complete all as specified and directed.
Cleaning of power house / sub station along with nearby areas with surface dressing 15 cm deep and cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
M&L for providing the mild steel plate size 0.05 sqm not less than 1.6 mm thick of triangle/rectangular/oval shape and synthetic enamel painting it with appropriate color and letters to identify the cable route along its length and angle iron 25mm x 25mm x 3mm and 0.5m height welded with plate and fixed vertically. Cable route markers will be placed at at fixed step-length along the length of cable complete all as specified and directed.
Attending breakdown attributable to cable faults, flashover in HT panel / VCB or any of the connected transmission line system & rectifying it in 33 KV / 11KV cable / transmission line network upto end connections with panels / transformers or any of electrical item connected therein at Air Force station, Chakeri Technical & Domestic area during any hours of a day during the currency of contract by engaging sufficient manpower after receiving communication through Complaint Section / Concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 hrs complete all as specified and directed. Note: The occurance of fault if any, will be comminicated to the contractor and the contractor shall rectify the same within 12 hrs of reporting, failing to which a recovery @ Rs 500/- per complaint per day and maximum of Rs 10,000/- shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources accordingly and the quoted rates shall be deemed to include the same. Further, all necessary equipment like HT megger, hand gloves, line testers, earth rod etc shall be readily avilable with the contractor's manpower under his own arrangement. Delay on account of non availability of such items shall not be considered for relaxation..
M/S S.DAYA SINGH
ashokcontractors
DUBEY TRADERS AND ENGINEERS
keerti trading corporation
PAWAN COOL CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .