Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹1.2 Cr+₹1.3 L (1.17%)Rejected-Finance | ₹1.2 Cr+₹1.3 L (1.17%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹1.2 Cr+₹1.5 L (1.27%)Rejected-Finance | ₹1.2 Cr+₹1.5 L (1.27%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹1.4 Cr+₹22.9 L (20.0%)Rejected-Finance | ₹1.4 Cr+₹22.9 L (20.0%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Admitted, Since remarks against your firm as NO in WLR QE DEC 2021 in CE SWC |
Tender Value
₹1.3 Cr
EMD Value
₹2 L
Closing Date
11 May 2022, 6:00 pmClosed
CWE JAIPUR
HQ CWE Jaipur, Kalyan Marg, Jaipur
SPECIAL REPAIR TO KV-02 SCHOOL BUILDING AT MIL STATION JAIPUR UNDER GE(S) JAIPUR
2022_MES_515760_1
CWE/JPR(S)/82148/E8
Open Tender
Civil Works
Item Rate
180 days
GE (S) JAIPUR
Enlisted with MES in Class B and above and category a (i)
7 documents required · 7 mandatory
₹1,000
Yes
GE (S) JAIPUR
₹2 L
Yes
30 Jun 2022
29 Mar 2022
13 May 2022
29 Mar 2022
11 May 2022
19 Apr 2022
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/ brick surfaces/ceiling etc. including raking out joints hacking for key scrubbing down with water etc including removing outside MD land complete all as specified and directed.
M&L rendering 15mm on brick masonry surfaces or surface other than fair faces of brick work on wall CM thick (1:6) finished even and smooth without using extra cement etc complete all as specified and directed.
Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint new plastered surfaces, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance interior acrylic emulsion paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of interior primer applied @ 0.90 litre/10 sqm over new surfaces over 1mm thick wall care putty on walls complete all as specified and directed by engineer in charge
M & L for complete removal of existing treatement and applying Two coats of 100% Premium acrylic emulsion paint on old plastered surfaces of wall, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces over 1mm thick wall care putty on walls complete all as specified and directed by engineer in charge
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair faces of brick work on wall in CM (1:4) on walls finished even and fair without using extra cement etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of weather coat paint of approved shade over a coat of primer over and including 1mm thick wall care putty for smooth etc complete all as specified and directed.
M&L complete removal of existing treatment and applying two coats of weather coat paint of approved shade over a coat of primer over and including 1mm thick wall care putty etc complete all as specified and directed.
M&L for rendering 15mm thick on brick masonry surfaces or surface other than fair faces of brick work on ceiling CM (1:4) finished even and fair without using extra cement etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces & applying three coats of white wash by mechanical means on ceilings etc complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls & applying two coats of white wash by mechanical means etc complete all as specified and directed.
Demolition/Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiling to store and rubbish off the premises etc including removing out of MD land complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar and removal of same from outside MOD land etc complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab size 550x550mm in flooring laid over 15 mm thick screed bed or bedding layer of cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grooving, rubbing and polishing etc complete all as specified & as directed.
M&L for 20-25 mm thick machine cut kota stone slab in riser of steps, skirting, dedo and pillar laid over cement backing coat 10 mm thick in cement mortar (1:4), laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified & as directed.
S&F joint free coloured glazed ceramic tiles in vertical surface 300x 450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including providing 10mm thick backing coat in CM (1:4) etc complete all as specified and directed.
M&L joint free non skid ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including providing 15mm thick screed bed in CM (1:4) etc complete all as specified and directed.
S&F stainless steel cloth 0.50mm nominal dia of wire and 1.00mm average aperture and fixed with stain less steel wire staples etc complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm etc complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each and removing to store etc complete all as specified and as directed.
Taking down shutters of any description exceeding 1 sqm and not exceeding 2.00 each and removing site etc complete all as specified and directed.
S & F 105x60 mm Pressed steel frames1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
Supply and fixing 30 mm thick Fibre glass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 as per manufacturer instruction etc complete all as specified and as directed.
S&F in repair steel window with side hung shutters factory made including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including taking down old etc complete all as specified and directed. (Note: Mild steel wire cloth shall be measured and paid separately under respective items)
S&F in repair factory made steel ventilator with top hung shutter with glazing bars including hinges, steel peg stay and handle etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer etc complete all as specified and as directed.
M&L for preparation old untreated steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint over etc complete all as specified and directed
S&F in repair 100 mm butt hinges medium weight cold rolled mild steel, ISI marked, fixed to angle iron chowkhat including welding etc complete all as specified and directed.
S&F in repair aluminium anodised tower bolts not less than 12mm dia of extruded section and fixed 150mm length of bolt etc complete all as specified and directed.
S&F in repair aluminium sliding door bolts 250mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed etc complete all as specified and directed.
S & F in repair aluminium handles of size 125 mm anodised type complete all as specified & directed
S&F in repair 140mm long door stopper of aluminium anodised and two rubber shoes etc complete all as specified and directed.
Hacking out old broken glass any thickness size, quality or description from wooden/steel frames fixed with wooden beads/metal pinning and S&F 3 mm thick sheet glass in squares not exc 0.50 sqm in each pane fixed with wooden beads or putty (in metal frame) etc complete all as specified and directed.
S&F in repairs fancy type mild steel chromium plated, stops, rollers including caps/side bulbs PVC powder coated etc complete all as specified and directed.
S&F in repair drapery rod PVC insulated 20mm dia including providing and fixing brackets and decorative knobs on each end of rod of approved pattern and colour etc complete all as specified & directed.
Supply only Integral waterproofing compound
Demolition of reinforced cement concrete in roofs, floors (other than ground floors ), beams, staircases, landing, chajjas and similar suspended work including removing outside MD land complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. complete all as per specified and directed.
M&L for Mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as per specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges complete for flat and fair finished surfaces of concrete.
M&L for Form work to flat rough finished sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels etc all as specified.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm th (Horizontal or sloping) Rough finished surface of concrete flat. etc complete all as specified & directed.
M&L for Reinforced cement concrete M-25 using 20mm graded stone aggregate) in chajjas/Roof projection
M&L Reinforced cement concrete M-25 using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified & directed.
M&L Reinforced cement concrete M-25 using 20 mm graded stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span . etc complete all as specified & directed.
S&F in repair for 15 mm GI tubing medium grade with all fitting and fixed to walls of concealed or fitted to ceiling or laid in under floor etc complete all as specified & directed.
S&F in repair for 20 mm GI tubing medium grade with all fitting and fixed to walls of concealed or fitted to ceiling or laid in under floor etc complete all as specified & directed.
S&F ball brass valves, high pressure, with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule and fixed of pipe in 20mm etc complete all as specified & directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified & directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified & directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends (any radius) etc. complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends (any radius) provided with access door etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, equal or unequal etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (single T), equal or unequal etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and directed.
M&L PVC(SWR) floor trap/ nahani trap, plain with grating including jointing to waste pipe with solvent cement dia of outlet 75 mm etc complete all as specified and directed.
M&L for surface preparation by removal of all loose particle to ensure clean, smooth and dry surface and remove all type of roof treatment from roof all as specified and directed by engineer in charge
M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes or roof treatment in CM 1:3 complete with WPC @ 3% by weight of cement etc complete all as specified and directed.
Roof Treatment:- 1. Complete removal of the existing roof treatment and disposed of the rubbish outside MOD land. 2. All visible cracks to be opened up in V shape and remove all loose particles, cleaned properly with wire brushes and cracks are to be filled with crack filling compound for cracks upto 15 mm width/depth of cracks. 3. Cracks of more than 15mm depth are to be filled with cement grouting like (URP Cement grout) by injecting through nozzles till refusal by authorized applicators of manufacturer carefully by following manufacturer’s instructions. The size and spacing of the nozzles shall be all as per manufacturers instructions/as directed by Engineer-in-Charge. 4. After drying, roof coat paint shall be applied (@ rate of 1 L per 1sqm) with roller in both directions with a gap of 12 hr for each direction over a self prime coat @ 0.5 ltrs of water mixed to 1L of roof coat paint. 5. Necessary guarantee of 05 years shall be submitted by the contractor. Make:- Roof Coat:- Choksey chemicals ( Roof coat-3)/berger(PU roof coat)/ Asian (smart care damp proof ) Cement grout: - Dr Fixit (Fixit pidicrete URP Model:301) /or equivalant in Fosroc/ choksey chemicals/ sika
S&F in repairs vitreous china squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including providing connection and lime concrete bedding to making good to floor etc complete all as specified & directed.
S&F in repair Vitreous China Wash down water closet pan pedestal pattern (EWC) white in colour, and including plastic water closet seat, closed pattern with flat bottom and cover and MS chromium plated hinging device including connection to outgoing pipe and flushing pipe etc complete all as specified & directed by Engineer-in-charge.
S&F in repair Vitreous China coloured EWC wall mounted with flushing cistern including PVC coloured sheet cover etc complete all as specified & directed. (Make-CERA CAT PART NO CQ 606or equivalent of MARC, JAQUAR etc)
S&F in repairs PVC valve less, syphonic action type flushing cistern 10 litres capacity, low level, white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC,32mm dia suitable for low level cistern etc complete all as specified & directed.
S&F in repair Vitreous China bowl flat back, size of (465 x 355 x 265)mm white (minimum), with grating and union for discharge pipe Vitreous china urinals, bowl type (back or corner wall type), complete including 32mm waste Fittings ,Brass, Chromium Plated For Glazed Ware Sinks, Basins, Etc. With Long Screwed And FlyNuts, Flange End Bedded In Red Lead Cement And Other end fixed including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe etc complete all as specified & directed.
S&F in repairs Vitreous China wash hand basin, white, flat back, size 550x400mm but including brackets, coupling and waste pipe etc complete all as specified & directed.
S&F in repair pillar taps 15mm bore swan neck, cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 15 mm thick screed bed cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed to 50mm bore of pipe including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 etc complete all as specified & directed.
S&F capacity of 1000 Litres rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old water tanks etc complete all as specified & directed.
M&L cement concrete (1:3:6) type C-2 using 20mm graded stone aggregates as in platform of rotational moulded polyethylene water storage tanks and dia of platform not less than 150mm etc complete all as per specified and directed.
S&F in repair bib taps 15mm bore long body cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed.
S&F in repairs fancy type stop valves cast copper alloy chromium plated screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore dia pipe etc complete all as specified & directed.
S&F in repair 15 mm dia Angle valve two way, cast copper alloy chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed etc complete all as specified and directed.
S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repairs soap dish vitreous china white approximate size 160 x 160 x 90mm fixed with chromium plated screws etc complete all as specified and directed.
S&F in repair CP brass towel rail 20mm dia, D type 60cm long etc complete all as specified & directed.
S&F factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face in frame at site as per specification & drawing.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening etc complete all as specified and directed.
Dismantling of loose reinforced cement concrete any description by chieseling , wedging etc. cutting the unserviceable reinforcement as in roofs, floors (including ground floors), beams, staircases, landing, chajjas, slab, similar suspended and columns work including removal all rubbish material where directed etc complete all as specified and directed.
Chipping the RCC surface and cleaning the rusted reinforcement and exposed surface by wire brush, mechanical device or any other established method and applying the rust removing solution of approved make and quality with cotton swab to reinforcement and allowing to dry the same for 24 hrs ,brushing of loose particles and applying 1st coat of rust preventive coating of polymer and cement slurry in 1:1.5 proportion with soft brush without adding water including applying another coat of rust preventing after 4 hrs allowing air curing for 48 hrs etc complete all as specified and directed.
S& F hard drawn steel wire fabric exc. 4 kg/Sqm weight cut to length bent to shape required and tying with & incl mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement etc complete all as specified and directed..
Replacing distressed/loose/cracked/ porous carbonated, loose part of concrete with fiberous micro concrete and repairing the damaged surface of concrete fix the formwork/ shuttering across the profile of damaged structural element , pour the free flow ready mix micro concrete mix with 5 ltr of water in the formwork. Microconcrete should be mixed in steel tray homogeneously makeup concrete is based on type of structural element and its location. The work should be carried out with all safety measures like helmet, safety belt and under supervision of qualified supervisor etc complete all as specified and directed.
M & L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n exc 20cm wide with rough finished surfaces etc complete all as specified and directed.
M & L for 15mm thick polymer modified mortar to load carrying RCC members in two layers in proportion of 1:5:15 by weight of polymer of approved make and quality, cement and quartz sand with required WC ratio for desired consistency and applying and finishing by floating, curing after initial setting time etc. as per manufacturer specification etc. complete all as directed and specified.
M & L for 30mm thick polymer modified mortar to load carrying RCC members in two layers in proportion of 1:5:15 by weight of polymer of approved make and quality, cement and quartz sand with required WC ratio for desired consistency and applying and finishing by floating, curing after initial setting time etc. as per manufacturer specification etc complete all as specified and directed.
M & L for applying SBR bond chemical of approved make before applying polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface using nylon burses scaffolding labour etc complete all as specified and directed.
M & L for drilling and fixing teflon perforated nozzles in RCC members including drilling 14mm dia 50 to 100 mm deep holes in structural members at the intervals of 600 mm in staggered manner all as directed including cleaning the holes by air blowers prior to fixing nozzles and fixed nozzles in cleaned holes. External ends of nozzles to be machined to receive outlet of grouting gun. nozzle is fixed by mean of epoxy to ensure complete sealing and cure the system for min 12 hrs under supervision of qualified supervisor etc complete all as specified and directed.
M & L for injecting high performance non shrink, free from high strength antiwash polymer cement grout of approved make by addition of water as per manufacturer’s instructions and specification into honeycombing area/porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 Kg/cm2 and subsequently cutting/ removing of nipples and sealing of holes with epoxy putty EPW 1010 etc complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing capping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces etc complete all as specified & directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sq mm (Green) drawn into and including concealed rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- (Note - Cost of cutting of chases in stone masonry and making good disturbed surfaces for concealing the conduit shall deemed to be included in quoted rate of point wiring) complete all as specified and directed.
(a) One light/Fan/Bell point controlled by one switch.
(b) One 3 pin 5 Amp socket outlet on the same board with other switches
(c) One 3 pin 5 Amp socket outlet on independent board with other switches
(d) One light point controlled by two, two way switches
M&L for point wiring using approved colour coding as per IS, with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) in and including concealed conduit with accessories fixed on surface/ceiling by means of PVC sleeve/dash fasteners with cadmium plated screw and teakwood blocks closed recessed for mounting switch,sockets,regulators etc. including, Mild steel Sunken box, earth dolly with zinc coated and 3 mm thick phenolic laminated sheet top cover including 1.5 sqmm single core PVC insulated and unsheathed copper conductor FRLS cable 1100 V grade (ISI marked) earth continuty conductor to common earth and connected as continuous earth wire to earth dolly compiete all as sprcified and ditected for followings :-. (Note: Cost of hole cutting in wall for bell point, bulk head, building security light and any other site requirement during work execution shall be inclusive in above quoted price. Wiring on stone wall is included in above quoted price.)
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sq mm (Green) drawn into and including concealed rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for 3 Pin 15 amp socket outlet point controlled by one switch on independent board. (Note: Cost of hole cutting in wall for bell point, bulk head, building security light and any other site requirement during work execution shall be inclusive in above quoted price. Wiring on stone wall is included in above quoted price.)
S&F switch modular type single pole one way 5/6 Amp 230 volts etc. complete all as specified and directed.
S&F switch modular type single pole one way 15/16 Amp 230 volts etc. complete all as specified and directed.
S&F switch modular type Two Pole, two ways 6 amp rating 230 volts etc. complete all as specified and directed.
S & F Socket outlet multipurpose modular type 230/250 Volts 2 in 1, 3 pin 5/6 Amp ratings etc. complete all as specified and directed.
S & F Socket Piano type 230/250 Volts 2 in 1, 3 pin 15/16 Amp etc. complete all as specified and directed.
S & F in repair stepped type electronics fan regulator flush type AC 230 volts single pole (ISI marked) for AC 230V, 50 Hz on laminated sheet etc. complete all as specified and directed.
S&F in repair Ceiling rose surface bakelite 65x50mm, 3 Phase/ PVC/ Polycarbonate isolated body (ISI marked) etc. complete all as specified and directed.
S&F lamp holder, angle type, polycarbonate type with back plate suitable for batten fittings etc complete all as specified & directed.
Supply and fix Batten LED light fittings 20/22 Watt, 240 Volt 4 feet size long life surface/wall mounting IP 20 Luminaire per watt maximum extruded aluminium housing with frosted PMMA diffuser with high brightness LEDs complete with all accessories pre wired twin core twisted flexible copper conductor cable with suitable size. Make: Syska Cat part No. SSK-T5-22W or equivalent in wipro/Philips.
Supply and fix LED panel 1 x 1 panel ceiling light with high brightness LED for glare free homogeneous commercial grade solution IP 20 Luminaire per watt maximum extruded aluminium housing complete with all accessories pre wired twin core twisted flexible copper conductor of suitable size. Complete all as specified and directed. Make: Havells Cat Part No. LHEWEJP6PW1W015 or equivalent in wipro/Philips.
M&L for sub main wiring along with earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x6 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit etc complete all as specified and directed.
M&L for submain wiring along with earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x4 sqmm + 1x2.5 sqmm earth wire in 20 mm dia conduit etc complete all as specified and directed.
Supply and fix factory made sheet distribution board double door protection class IP-42 double door type suitable for mounting MCB/MCCB conforming to IS 13032 IS- 8623 and BS 5484 with minimum 200 Amps bus bar. DBs shall be fixed on wall in flush pattern by chase cutting in stone or brick wall and disturbed surfaces shall be made good even and smooth using CM (1:3) as required etc complete all as specified and directed with following ratings & ways:- (a) SP & N 12 ways- 8 Nos (b) SP & N 8 ways-6 Nos
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs etc complete all as specified and directed with following ratings:-
SP 5 to 32 Amps rating
SP 32 to 63 Amps rating
Supply and fix exhaust fan 300 mm in sweep complete all as specified and directed.
Supply and fix louvers made of galvanised iron of 300 mm including fixing with suitable fasteners complete all as specified and directed.
Material and labour for cutting hole of 300 mm in existing stone wall with suitable drilling equipment making good the disturbed surface plastering the surface with cement mortar 1:6 complete and matching the disturbed surface with existing surface complete all as specified and directed.
S&F in repairs Energy efficient LED security lights of 45Wattage of IP 66 with PDC Aluminium body and clear glass, LED lens for wide beam distribution with efficacy greater than 100 Lm/watt , 5700K CCT, pf more than .90 all as specified and directed by Engr-in-charge. Make - CG Cat Part No. LSTS-40-CDL or Equivalent in Wipro/Philips (Note:- Bracket along with screw to fix on wall/surface duly painted by silver colour paint will be included in above quoted rate.)
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover etc complete all as specified and directed. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply and fix in repair sheet metal enclosure complete with metallic plug and socket heavy duty modular type 3 pin (2P+ Earth) 32 Amps rating single phase 240 Volts complete with MCB SP 32 Amp C series complete all as specified and directed.
supply and fix TPN sheet steel power coated double door vertical distribution board 08 way fitted with two cover one screwed cover for incoming and outgoing MCBs and second for protection of MCBs fitted with colour coated Bus bar neutral link earth bar Din rail suitable for use of 240/415 Volts 50 Hz supply including on incoming MCCB 100 Amps Ratings 4 pole, MCB DP 63 Amps ratings 08 Nos. and RCCB 01 Nos. complete all as specified and directed. Make: HPL cat Part No. DBVDD08163 or equivalent. (Note: Cost of wall cutting for suitable mounting of DBs in recess alongwith proper connection with suitable lugs and making good disturbed surfaces with PCC work will be inclusive in above item quoted price.)
Supply and fixing 40mm dia steel tubing galvanised light grade for passing cable under road floors or fixing to poles for mechanical protection of under ground cable complete with flat iron clamps made of shape and 12 mm dia bolts nuts and washers fixing where required complete all as specified and directed. (Note: Cost of Cable protection in floors and on walls with 40 mm GI pipe in DBs/Panels will be inclusive in above quoted rate)
Schedule of Credit
M/S Anil Enterprises
Satish kumar and company
J.J.ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .