Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Other than lowest tenderer | |
| 2 | L2₹17.8 L+₹2.8 L (18.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹18.3 L+₹3.3 L (21.9%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹19.4 L+₹4.4 L (29.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹27.5 L+₹12.5 L (83.3%)Rejected-Finance 82 6 82 6 TRANSPORT NAGAR NARWAL NARWAL JAMMU JAMMU AND KASHMIR 180010 | JAMMU | JAMMU AND KASHMIR | 180010 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR/REPLACEMENT OF EXTERNAL ELECTRIC SERVICES AT CHARLI HILL AND KATRA UNDER GE NAGROTA.
2021_MES_477695_1
GEN-45/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class E and above and Category b(I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹50,000
Yes
10 Nov 2021
24 Sept 2021
27 Oct 2021
24 Sept 2021
25 Oct 2021
9 Oct 2021
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, electric poles stay foundation and under ground electric power cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and exc 1.5 m but not exc 3 m in depth for foundation etc or not exc 10 sqm on plan and exceeding 1.5 m but not exc 3 m in depth for shaft, wells , cesspits, manholes, pier holes, etc and getting out in any types of soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm complete in any type of soil, complete all as specified and directed.
Removing of surplus excavated soil not exceeding 50 m distance and depositing where directed by Engr-in-Charge at level not exceeding 1.5 mtr above starting point, complete all specified and directed.
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge..
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete as per specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping/above ground level around the pole etc, complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 95 Sqmm 3.5core including taking down old cable, complete all as specified and directed.
All as per ser item No. 10.00 here in above but 70 sqmm 3.5 core
All as per ser item No. 10.00 here in above but 35 sqmm 3.5 core
All as per ser item No. 10.00 here in above but 25 sqmm 4 core
All as per ser item No. 10.00 here in above but 16 sqmm 4 core
S&F PVC insulated aluminium conductor 1100 volts of size 6 Sqmm 2 core service cables, complete all as specified and directed.
S&F PVC insulated aluminium conductor 1100 volts of size 10 Sqmm 2 core service cables, complete all as specified and directed.
S & F in repairs 80 mm bore Steel tubing galvanized, Light grade, conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete with flat iron 50x6 mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required, complete all as specified and directed. (NOTE:- Excavation and earth work shall be measured and paid separatly)
Cleaning, preparing and painting with two coats of grey samson paint on 9/11m poles, cross arms, MS channels, angle iron, frame work bracing including numbering of pole and writing of feeder name with black enemelled paint from stencil, complete all as specified and directed.
S & F 10mm thick Synthetic insulating mat suitable for 11000 volt grade (ISI Marked) of size 2mx1mx10mm, complete all as specified and directed.
Labour only for repair/rectification/re-stringing restraching of all electric fault occured in OH ACSR conductor laid over, over head LT line on steel / PCC poles after removing binding from insulator and rewinding the conductor with insulator including providing spacer and new binding wire jumpering provide with after restraining and removing unavoidable sags in the line and trimming of tree and branches on LT line for minimum clearance, complete all as specified and directed.
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repair, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified and directed.
S&F in repairs switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and continuous current rating upto 200 amp and volt 11 KV, complete all as specified and directed.
S & F in repairs GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in gound fixed alongwith poles, complete all as specified and directed.
S&F in repairs 12 mm dia and 300 mm long air termination, single pointed aluminium rod, complete all as specified and directed
S&F in repair of aluminium strip 25x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors and down conductors above ground, complete all as specified and directed
S&F porcelain insulator of required size not exc 10 cm long with two nos hole each on both end for fixing properly with fastner,nut & bolts on wall & roof of bldg for seperated earthing strip from bldg all required at site & directed by Engr in Charge.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed.
Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer fixed "as in repairs", complete all as specified and directed .
M&L Stay assembly galvanised iron complete with accessories stay rod 18mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.
Cleaning of MES electric supply insatllation/Campus/Four pole structure by surface dressing or trimming of natural ground to remove small un equilities not exc 15 cm deep (incuding removing vegetation including shrubs /brushwood /undergrowth etc) carrying away the rubbish to a distance of not exc 50 m away, complete all as specified and directed.
Supply and fixing in replacement MCCB 250 Amps, four pole, 415 volt with breaking cap 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
Supply and fixing in replacement MCCB 200 Amps, four pole, 415 volt with breaking cap 25 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
Supply and fixing in replacement MCCB 100 Amps, four pole, 415 volt with breaking cap 25 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in repairs Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 100 amps, complete all as specified and directed.
S&F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA "C" series, complete all as specified and directed
S&F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA "C" series, complete all as specified and directed
Supply, Fixing , Commissioning and tessting of CPRI approved outdoor cubical type LT Feeder Piller box suitable for 415 V, 3 Phase , 4 wire 50 Hz , AC Supply system fabricated from stainless steel totally encloused ,dust, weather & vermin proof , 3.00 mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick having TPN aluminium busbar of capacity 200 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB FP 100 Amp, 16 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
M&L for transformer plateforms of size 2.50 m x 2.50m x 1.20m with following specifications as under a) Brick work in sub class B brick old size burnt clay bricks exc 6m mean radius on plan in CM 1:4 b) PCC 1:3:6 as in foundation filling and mass concrete. c) Stone boulder filling n.exc 63mm including hand packing and ramming. d) PCC 1:2 :4 as in flooring / top surface of plate form complete e) 15mm thick plaster on surface of brick work in CM 1:4 complete . f) Angle iron 60x60x5mm and 1.20 Mtr Length as in post for fencing . g) Chain link fencing of Size 50x50X3mm for transformer plateforms of size 2.50 m x 2.50m x 1.20m.
Disconnecting and removing to workshop opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440V and output voltage 420 V capacity 25 KVA to 30 KVA, complete all as specified and as specified and as directed Note :- (i) Cost of transportation of voltage stabilizer to workshop and back after repair/rewinding complete is deemed to be included in the quoted rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid in respective item.
Dismantling and rewinding of dimmer coil with super enameled copper winding wire of existing make and size complete in all respect including varnishing tapping and insulating material to get same capacity of 25 KVA to 50 KVA, complete all as specified and directed.
Replacement of electronic circuit plate complete with DC transformers complete all as per existing size and shape (PCB cold), complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
S&F in replacement of street light timer Analog time switch with timelite 32 A 3 pole/230 V with timelite DB, programmable every 1 min backup of 6 yrs , 28 memory location current capacity 32 A with 2 changover (2 CO) total 28 program, complete all as specified and directed
S&F junction box made of SMC/FRP shet ready made of sice 300 mm x 200 x 105 mm having 100 A capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6A 10 KA 240V-01 Nos with fixing arrangement fixed properly to pole/fixed on wall with MS clamps 258 x 5 mm and nut and bolts complete all as specified and directed
S&F in repairs for three run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay copper conductor and drawn through pole from junction box to street light throuh conduit pipe properly fixed with pole through clamps ,nut bolts etc , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of 60 W LED Street Light luminaire confirming including all necessary arrangement for fixing on Pole made up of Epoxy coated pressure Die Cast aluminum housing confirming IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Street Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .Built in surge protection of 4 kv and External surge protection of 10 kv provided for additional safety.side entry mounted for 40 mm and above OD pipe bracket. The LED shall be tested with LM80-08 standard .The LEDs used in Street Light shall have CCT of ≥ 5700 K with CRI of ≥70. The LED Street Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have luminous of ≥ 90/watt and power factor more than 0.9 with THD less than 10% , complete as specified and as directed.
Supply and fixing in replacement of 120W LED Flood Light luminaire made up of Epoxy coated pressure Die Cast aluminum housing. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Flood Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .External surge protection provided for additional safety. The LED shall be tested with LM80-08 standard .The LEDs used in Flood Light shall have CCT of 6500 K with CRI of ≥ 70. The LED Flood Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Driver shall have minimum 04 KV and External surge protection of 10 kv for additional safety. The LED Flood Light shall have power factor more than 0.9 with THD less than 10%. having luminous ≥ 105/watt ,with advanced opticle system in order to provide improved lightining complete including complete electrical connection with fixing arrangenment on pole or wall, complete as specified and as directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 92,440.00 during AOC Note:- Tenderers shall not quote for this Schedule
proach associates
MAMTA ENTERPRISES
ASHOKA ENGINEERS AND BUILDERS
Balbir Enterprises
M.S Sharma Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .