Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹28.6 L+₹64,292.25 (2.30%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹29.3 L+₹1.3 L (4.68%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹31.1 L+₹3.1 L (11.0%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹31.8 L+₹3.9 L (13.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | Rahul Enterprises L3 | M/S Anand Enterprises L5 | M P TYAGI ENGINEERS AND CONTRACTORS L4 | jain associates L2 | sumit associates L6 | Yadav Enterprises L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00JOB NO. SL INDIA/06/2025-26 : SPL REPAIR TO EXISTING WATER SUPPLY PIPELINE SYSTEM AT NARAINA BAGH IN AOR OF AGE (U) W/S NO - I UNDER GE (U) W/S DELHI CANTT-10. | |||||||||
| 2.00 | Excavation in trenches not exc.1.5m wide and not exc. 1.5m in depth including getting out in soft/loose/ Hard soil complete all as specified and directed. | 260 | CUM | 90 ₹23,400 Lowest | 90 ₹23,400 Lowest | 149 ₹38,740 | 100 ₹26,000 | 100 ₹26,000 | 100 ₹26,000 |
| 3.00 | Retuning filling in including spreading, levelling, watering and well ramming in layers not exc. 25Cms complete all as specified and directed. | 234 | CUM | 19 ₹4,446 | 40 ₹9,360 | 19 ₹4,446 | 15 ₹3,510 Lowest | 30 ₹7,020 | 40 ₹9,360 |
| 4.00 | Removing excavated materials (Soil) and depositing to a distance not exc 50m where directed at a level not exc 1.5m above from starting point complete all as specified and directed. | 26 | CUM | 90 ₹2,340 | 40 ₹1,040 | 29 ₹754 | 15 ₹390 Lowest | 50 ₹1,300 | 40 ₹1,040 |
| 5.00 | Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface all as specified and directed. | 1.25 | CUM | 490 ₹612.5 | 200 ₹250 Lowest | 299 ₹373.75 | 2,665 ₹3,331.25 | 1,200 ₹1,500 | 4,000 ₹5,000 |
| 6.00Taking up DI/GI/CI/MS Pipes including all fitting of the following sizes as specified and directed by Engineer-in-Charge :- | |||||||||
| 6.01 | 100 mm bore | 375 | RM | 19 ₹7,125 | 10 ₹3,750 Lowest | 19 ₹7,125 | 55 ₹20,625 | 20 ₹7,500 | 20 ₹7,500 |
| 6.02 | 150 mm bore | 570 | RM | 39 ₹22,230 | 10 ₹5,700 Lowest | 19 ₹10,830 | 110 ₹62,700 | 20 ₹11,400 | 20 ₹11,400 |
| 7.00Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work route indicators of the size 100 mm bore complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ. Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates. Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site. Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly. Note5:- Layout plan for laying of DI pipe shall be given by EIC in writing. | |||||||||
| 7.01 | 100mm | 300 | RM | 1,149 ₹3,44,700 Lowest | 1,350 ₹4,05,000 | 1,299 ₹3,89,700 | 1,200 ₹3,60,000 | 1,590 ₹4,77,000 | 1,325 ₹3,97,500 |
Tender Value
₹33.8 L
EMD Value
₹67,700
Closing Date
1 Oct 2025, 6:00 pmClosed
GE(U)(W/S) DELHI CANTT
GE(U)(W/S) DELHI CANTT 110010
SPL REPAIR TO EXISTING WATER SUPPLY PIPELINE SYSTEM AT NARAINA BAGH AND PROVN OF WATER BORE WELL FOR 1 WEC IN THE AREA OF AGE (U) W/S NO - I UNDER GE (U) WATER SUPPLY DELHI CANTT-10
2025_MES_729093_1
GE/WS/Token No-28 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE(U)(W/S) DELHI CANTT
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE(U)(W/S) DELHI CANTT
₹67,700
1 Dec 2025
3 Sept 2025
3 Oct 2025
3 Sept 2025
1 Oct 2025
18 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .