Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID QUOTED | |
| 2 | L2₹20.0 L+₹5.5 L (38.0%)Rejected-Finance | L2 | Rejected-Finance HIGHEST BID QUOTED | |
| 3 | L3₹22.9 L+₹8.4 L (57.8%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance HIGHEST BID QUOTED |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
24 Dec 2020, 6:00 pmClosed
GE (AF) Gurgaon
GE AF GURGAON
REPAIR REPLACEMENT OF OLD CI GI PIPELINE, GATE SLUICE VALVE, SUBMERSIBLE PUMPS, MOTOR, CEILING FAN EXHAUST FAN, PERIODICAL SERVICING, REPAIR MAINTENANCE OF AC, WATER COOLER, DEEP FREEZER WATER HEATER, DG SETS, BUS BAR CAMBER, REPAIR MAINTENANCE T
2020_MES_398561_1
GE/GUR-/NIT-59/2020-21
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹56,000
Yes
21 Jan 2021
26 Nov 2020
26 Dec 2020
26 Nov 2020
24 Dec 2020
10 Dec 2020
Amount
Comprehensive maintenace & servicing of DG set of capacity 18.75 KVA to 30 KVA, (Periodical) 'B' check including replacement of fuel filter/oil filter and minor parts if required as per manufacturer recommendation, replacement of Engine oil coolant etc all as directed & comprising of checking of following:- (i) Fuel supply system of Engine. (ii) Lubricant system of the engine. (iii) Battery charging system of the DG set. (iv) Control panel of the DG set. Note :- Engine oil/coolant shall be measured and paid seperately as supply only.
Supply only Engine oil of best quality complete all as specified and directed
Supply only Coolant of best quality complete all as specified and directed
S & F in replacement alternator 12 volt for 25/30 KVA DG set complete all as specified and directed. Make - MICO/LUCAS
S & F in repair self startor 12 volt for 25/30 KVA DG set complete all as specified and directed. Make:- MICO/LUCAS
S & F in repair of Battery charger suitable for charging battery upto 12 volt 88 AH of DG set complete all as specified and directed.
S & F in repair of battery Maintenance free tubular type 12 volt 88 AH of DG set with initially charged complete all as specified and directed. Make:- Exide/AMRON/TATA Green.
Commissioning & Testing after Comprehensive maintenance & servicing cleaning of AMF panel of 30 KVA generator set ,replacement of unserviceable parts ,testing /detection of faulty component /wring etc complete all as specified and directed. New items fixed will be measured and paid separately under relevant items
Supply and fix in repair spare parts/component of AMF panel 30 KVA as under :-
MCCB 63 Amps ,breaking capacity 36 KA ,TP,microprocessor based ,including over voltage protection.Make:-Legrand /L&T/ABB
Power contactor 3pole AC 415 Volt 63 Amps ,Make : Legrand /L&T /ABB
Indicating Lamp LED Type (R,Y,B)
M&L for excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth for laying Power Cable in loose/soft soil and getting out complete all as specified and directed.
M&L for returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
M&L for removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Supply and laying sand cushioning for cable protection in trenches all as specified and directed.
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed .
Taking down the existing unserviceable cables from trenches of any size all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 120 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 70 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 50 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 25 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 2.0 core X 25 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 2.0 core X 16 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
M&L for manual horizontal boring 1.5 M below the ground level 80 mm dia for road crossing with out disturbing the existing road/pcc,getting out and disposal of soil to distance not exceeding 50M from the site of work complete all as specified and directed by engr-in-charge.
M&L for GI tubing 80 mm dia (Light grade) galvanised laid in trenches for road crossing complete all as specified and directed by engr-in-charge.
Supply & install in repair Bus Bar chamber out door type ,LT (415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , outdoor type weather and vermin proof (Protection Class IP-54) of size 800x700x800 mm and made out of 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed of rating 200 Amps.
Commissioning & testing after Comprehensive maintenance & servicing /cleaning of Automatic power factor panel,replacement of defective part, detection of faulty component /wiring & testing complete all as specified and directed .New spares replaced will be measured and paid separately under relevant items..
Supply and fix in replacement spare parts/component of KVAR Power factor panel:-
MCCB 160 Amps ,breaking capacity 35 KA ,TP, Make:-Legrand /L&T/ABB
MCCB 100/63 Amps ,breaking capacity 16 KA ,TP Make:-Legrand /L&T/ABB
Power contactor 3pole AC 415 Volt 32 /63 Amps ,Make : Legranfd /L&T /ABB
APFC relay ,6 stage 415 volt three phase
Capacitor cylindrical type upto 25 KVAR 440 volt,3phase 50 HZ delta connection.(12.5 x4 no + 25 x 1 no)
Supply and fix in replacement,MCCB ,3 pole,microprocessor based ,16/25/35/50 KA including under voltage/over voltage relay all as specified and directed.
MCCB 400 Amps,50 KA,3 pole make-HPL/L&T/Schneider
MCCB 200Amps,35 KA,3 pole make- havells/L&T/Schneider
MCCB 125Amps,35 KA, 3 pole make- L & T/ havells/Schneider
MCCB 100Amps, 16/25 KA,3 pole make -L & T/ havells/Schneider
Supply and fix in repair Fluorescent tube light fitting. 1 x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessoriesprewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Make:-Sudhir controls/CG/bajaj
Supply and fix in repair switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified and as direceted.
Supply and fixing LED Street light Luminaries 1x45 watts aluminium dia cast housing with efficient heat dissipation design . toughned glass cover,with IP 66 protection with copper cable 1.5 sqmm from junction box to light fitting connector block complete all as specified and directed. Make : Havells/ Phillips / Crompton Greaves
Supply and fixing LED Street light Luminaries 1x 60 watts aluminium dia cast housing with efficient heat dissipation design . toughned glass cover,with IP 66 protection with copper cable 1.5 sqmm from junction box to light fitting connector block complete all as specified and directed . Make : Havells/ Phillips / Crompton Greaves
Supply and fix in repair flood light fitting with LED flood light 120 watt with die cast aluminium spigot housing toughened front glass cover IP 66 protection and connecting with copper cable 1.5 sqmm from junction box to light fitting connector block complete all as specified and directed with decorative opal acyrlic diffuser and IP65 protection all as specified and as directed.Make: Bajaj/Surya/CG
M&L for GI Tubing ( medium grade,ISI ) mark 32 mm dia ,1.5 mtr long light grade , bend to shape for street light fitting bracket , with 2x pair of MS clamp of suitable length of size 40 mm x5 mm of MS flat iron with nuts,bolts and washer including two coats of synthetic enamel aluminium paint over a coat of red oxide ,clamps fixed on pole or grouted on wall complete all as directed .
S&F in repair rigid steel conduit 19mm dia fixed to pole complete all as specified and directed.
S&F in repair street light junction box made out of PVC Of size 300mmx250mmx170mm consisting of triple phase & neutral, 63 amp terminal block and 01 no MCB 06 amp fixed on pole complete all as specified and directed.
Supply and fix in repair of automatic timer switch ,which ON/OFF the street light based on LUX cover of natural light ,current rating -40 Amp ,4 pole ,415 volts ,AC 50 HZ Max ,The sensor based timer should be have over voltage and low voltage trip with auto reset facility. The sensor along with suitable power contractor ,MCB and support terminal should be enclosed in pole /wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FR grade special mounting compound (sintex make ) confirming to IP 54.
Taking down of worn out wiring 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as specified and as directed.
Taking down of street light fitting/ Flood light fitting complete all as specified and as directed.
Taking down of street light junction box complete all as specified and as directed.
Supplying, laying in trenches/ pedestals, testing and commissioning cast iron pipes 150 mm dia bore with spigot & socket end centrifugally cast class B, in requisite length and conforming to IS complete all as specified and directed.
Supplying, laying in trenches/ pedestals, testing and commissioning cast iron pipes 80 mm dia bore with spigot & socket end centrifugally cast class B, in requisite length and conforming to IS complete all as specified and directed.
Taking up or down cast iron water mains 150 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Taking up or down cast iron water mains 80 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Supply, laying and jointing heavy duty CI Bends (any type, radius and angle ), Tapers any type,( straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, Y junction, Double branch, Cross (all sockets or socket and spigot or all flanged or one end flanged and other ends spigot /socketed), Collars, Caps and Plugs complete and conforming to IS : and upto 150 mm bore
M&L for run lead joints for 150mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering lead complete all as specified and directed :-
Ditto item No 46 but 100mm dia bore
Ditto item No 46 but 80 mm dia bore Note for item Nos 46 to 48 :- The Excavation in muddy soil including removing water by any means for supply and fixing Run lead joint after removing jointing material cocking the required materials properly complete will include in quoted rated in the item itself.
Supply laying, testing GI tubing 50 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 25mm dia bore medium grade conforming to IS : 1239 of with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Supply laying, testing GI tubing 20mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply,fixing and testing Gun metal gate valve 25mm ,screwed body ends and cast iron hand wheel conforming to IS 778-1984 ans ISI marked complete all as specified and directed.
Supply,fixing and testing Gun metal gate valve 20 mm ,screwed body ends and cast iron hand wheel conforming to IS 778-1984 ans ISI marked complete all as specified and directed.
Drilling and tapping cast iron water mains for branch connection of the internal dia 20mm including clamp piece and nuts and bolts all as specified and directed.
Taking down of exixting GI tubing 50 mm bore any type.
Taking down of exixting GI tubing 25 mm bore any type.
Taking down of exixting GI tubing 20 mm bore any type.
Supply only calcium based white to off white free flowing solid granuals chemicals having chlorine content of minimum 60% for chlorination in 45 kg packing . Make:-As approved by GE.
Supply ,fixing ,testing and commissionng double flanged non-rising stem type cast iron sluice valve suitable for 80 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed. Make : Kirloskar/L&T/zoloto
Supply ,fixing ,testing and commissionng double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and directed. Make : Kirloskar/L&T/zoloto
Taking out of sluice valves/ NRV from existing pipe lines upto 80/100/150 mm bore complete all as specified and directed.
Taking out of Gate valve 25/20 mm bore complete all as specified and directed.
Chemical and bacteriological testing of water sample (essential test only) from Govt approved laboratory to ensure portability of water complete all as directed.
M&L for following repair of Submersible pump set of cap 12.5 HP complete all as specified and directed.
Rewinding of stator of motor of pump set with same gauge of winding wire with insulating material after removal of burnt winding all as specified
S&F in repair Thrust Bearing
S&F in repair Bush for pump
S&F in repair coupling for pump motor
S&F in repair rotor
S&F in repair Rocker with housing and screw
S&F in repair Thrust bearing housing
S&F in repair stage bowl
S&F in repair Impeller GM
S&F in repair Motor bearing bush
S&F in repair SS sleeves
S&F in repair sand guard
S&F in repair Pump shaft stainless steel
S&F in repair Non return valve
S&F in repair Diffuser
Lifting of submersible pump set any description from borewell including coloumn pipe and submersible cable and lowering of pump in bore well after repair of pump or development of borewell all as directed Note: cost of disconnecting pipe from header / cables from panel shall be deemed to be included in the quoted rate.
Supply and fixing and water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade 6.0 Sqmm protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable and depositing to MES store yard complete all as specified and as directed.
Comprehensive maintenance and servicing of split type air conditioner cap 1.5/2.0 Ton, cleaning of cooling/candensing coil ,oiling of condenser fan motor, cleaning of air filter testing for smooth functioning complete all as specified and directed.
Comprehensive maintainence and servicing of water cooler cooling cap 40 litre /storage cap 80 litre cleaning of cooling/candensing coil ,oiling of condenser fan motor, cleaning of drain pipe testing for smooth functioning complete all as specified and directed.
Comprehensive maintenance and servicing of Deepfreezer any capacity by cleaning of cooling/candensing coil ,cleaning of complete refrigerator and testing for smooth functioning complete all as specified and directed.
M& L for detection of refrigerent leakage from split type AC, repair of cooling coil/condensing coil for minor leakage if any , flushing of system and gas charging in the system up to required qty , and sealing /closing of charging valve of split type Ac/withdow type AC cap 1.50/2.0 tr complete all as specified and directed.
M& L for detection of refrigerent leakage from Deepfreezer of any capacity , repair of cooling coil/condensing coil for minor leakage if any , flushing of system and gas charging in the system up to required qty , and sealing /closing of charging valve of Refrigerator complete all as specified and directed.
S&F in replecement new sealed compressor rotory type suitable for 1.5 Ton capacity single phase, 230 Volt, 50 Hz split type airconditoner in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and directed.
S&F in replecement new sealed compressor reciprocating type suitable for 1.5 Ton capacity single phase, 230 Volt, 50 Hz split type airconditoner in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and directed.
S&F in repair replecement new indoor unit suitable for single phase, 230 Volt, 50 Hz split type airconditoner for 1.5 Ton capacity as per star rating and power saving model and suitable make complete all as specified and directed.
Supply and fix spare parts for split type AC complete all as specified and directed:-
Material and Labour for Running Capacitor 36mfd-- . ( MAKE: Tesla / Tibcon )
Material and Labour for Starting Capacitor 80-100 mfd. MAKE: Tesla / Tibcon )
Material and Labour for replacement of new PCB suitable for split type AC 1.5 Ton.
Supply and fix copper tubing flexible of dia 1/2" complete in and including soldering and thermal insulation taping to copper tubing neatly all as specified and directed.
Supply and fix copper tubing flexible of dia 1/4" complete in and including insulation taping to copper tubing neatly all as specified and directed.
Material and labour for Drain pipe rigid and flexible 20mm dia with clamps uf suitable size as per site reuirement
Material and Labour for relay suitable for split AC 1.5 TR capacity
Material and Labour for blower motor for indoor unit suitable for split AC 1.5 TR capacity
Material and Labour for blower motor for outdoor unit suitable for split AC 1.5 TR capacity
Material and Labour for louver motor for indoor unit suitable for split AC 1.5 TR capacity
Comprehensive maintenance of electric geyser ,storage type 230 volts single phase AC ,25/50 lts capacity and descaling of inner tank of geyser ,including brazing /welding if required ,replacement of worn out parts,re-assembling and refixing on site ,including preparation of surface of geyser and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and directed.NOTE:Spare parts like heating element ,thermostat ,base assembly ,inner vessel will be measured and paid separately.
Supply and fix spares suitable for geyser for the following :-
Heating element 1500 watt capacity suitable for 25/50 Ltr Capacity geyser (As per sample),Make :bajaj/ Theeta
Heating element 2000 watt capacity suitable for 25/50 Ltr Capacity geyser (As per sample), Make :bajaj/theeta
Thermostat suitable for 25/50 ltr capacity Geyser
Indication lamp for 25/50 Ltr capacity Geyser
Fusible plug melting at 95-100 degree centigrade
PVC flexible copper conductor cable 2.5 Sqmm ,3 core
Supply and fix in replacement of PVC connecting pipe 18'' long with base adopter for cold water /hot water and connecting up complete for 25/50 ltr capacity geyser,complete all as specified and directed.
M& L for grouting of fastener (screw type ) ,washer ,bolt in wall for geyser complete all as specified and directed.
M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nuts /bolts/washer /split pin and blade screw s etc testing , complete all as specified and directed. NOTE: (i) Spare parts like bearing,capacitor if required will be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts.
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Supply and fix in repair ball bearing suitable for the following fans : make NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep make:- NBC
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Supply and fix in repair capacitor 2.5 mfd,400 volt ,50 hz all as specified and as directed.Make : Tibcon/ Havells
Supply and fix in repair capacitor 4 mfd,400 volt ,50 hz all as specified and as directed Make : Tibcon/Havells
D P ENTERPRISES
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .