Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.2 L+₹1.2 L (7.89%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹16.7 L+₹1.7 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹17.7 L+₹2.7 L (18.0%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L4₹18.6 L+₹3.6 L (24.1%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
ROUTINE MAINTENANCE OF LT NETWORK AND ELECTRIC INSTALLATION AND PREVENTIVE MAINTINANCE OF SERVO VOLTAGE STABILIZER AT AF STN BAMRAULI
2022_MES_546068_1
8743/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹60,000
29 Oct 2022
18 Aug 2022
19 Sept 2022
18 Aug 2022
17 Sept 2022
2 Sept 2022
Amount
Excavation in trenches/Pits in any type of soil(soft/loose/hard/ dense soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete, all as specified & directed .
Returning filling in with the earth obtained from Item No 1 here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified & directed.
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified & directed
M&L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other all as specified and directed by the Engineer-in-charge.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning all as specified & directed
Supply and laying in replacement of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elect power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 Sqmm 4 core.
All as per item No 6 but size 25 sqmm 3.5 core. .
As per item No 6 but size 35 sqmm 3.5 core.
As per item No 6 but size 50 sqmm 3.5 core.
As per item No 6 but size 70 sqmm 3.5 core.
As per item No 6 but size 95 sqmm 3.5 core.
As per item No 6 but size 120 sqmm 3.5 core.
As per item No 6 but size 185 sqmm 3.5 core.
As per item No 6 but size 300 sqmm 3.5 core.
As per item No 6 but size 400 sqmm 3.5 core.
M&L for Painting of 9 m steel pole with cross arms, clamp of any length and shape for LT overhead line with two coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15 cm dia White circle & marking three black & two White bends width 30 cm by fluorescent paint,from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
M&L for Painting of 11 m steel pole with cross arms, clamp of any length and shape for LT overhead line with two coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15 cm dia White circle & marking three black & two White bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
M&L for Repair and replacement of existing rusted panel board doors through welding and make good out of 2.6 mm ( 12 SWG) thick CRCA sheet duly painted with two coats of approved enamel paint over a coat of red oxide primer all as specified & directed.
M&L for Repair and maintenance of 3 phase, oil cooled servo stabilizer (any make) of following capacities after disconnecting all incoming/outgoing connections, taking out of dimmer stator, main transformer from the body, transformer oil etc cleaning the body, re-assembling and re-installed the same after repairs including connection and continues load testing for eight hours complete all as specified and directed:- Note :- (1) Supply and fixing Spare parts shall be measured and paid separately under respective item of Sch 'A'. (2) All Work shall be carried out by OEM
(b) 10 KVA to 30 KVA.
M&L for cutting down/removing existing burnt winding from main transformer of servo stabilizer 400 KVA of any make and rewinding with super enameled copper wire matching to existing gauge/size including all insulated material complete all as specified and directed.
M&L for cutting down/removing existing burnt winding from main transformer of servo stabilizer 160/200/250 KVA of any make and rewinding with super enameled copper wire matching to existing gauge/size including all insulated material complete all as specified and directed.
M&L for cutting down/removing existing burnt winding from main transformer of servo stabilizer 50/100 KVA of any make and rewinding with super enameled copper wire matching to existing gauge/size including all insulated material complete all as specified and directed.
M&L for cutting down/removing existing burnt winding from main transformer of servo stabilizer 30/10 KVA of any make and rewinding with super enameled copper wire matching to existing gauge/size including all insulated material complete all as specified and directed.
S&F in replacement of RC net work for 400 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of RC network for 100/200/250 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of RC network for160 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of RC network for 50 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of RC network for 30/10 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of rotary switch for 400 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of rotary switch for 100/200/250 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of rotary switch for 160 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of rotary switch for 10 to 50 KVA servo stabilizer of any make complete all as specified and directed.
S&F circuit board (PCB) for 400 KVA servo stabilizer of any make complete all as specified and directed.
S&F circuit board (PCB) for 100/200/250 KVA servo stabilizer of any make complete all as specified and directed.
S&F circuit board (PCB) for 10 to 50 KVA servo stabilizer of any make complete all as specified and directed.
S&F in replacement of push button of servo stabilizer of following capacity of any make complete all as specified and directed:-
Suitable for 400 KVA.
Suitable for 250/200/100 KVA
Suitable for 10 to 50 KVA.
S&F in replacement of servo motor of 400 KVA servo stabilizer after disconnecting all connection complete all as specified and directed.
S&F in replacement of servo motor of 250/200/100 KVA servo stabilizer after disconnecting all connection complete all as specified and directed.
S&F in replacement of servo motor of 10 to 50 KVA servo stabilizer after disconnecting all connection complete all as specified and directed.
S&F in replacement of voltmeter 0-500 volt digital type accuracy class 1 matching to existing one complete all as specified and directed.
S&F in replacement of ammeter digital type accuracy class 1 matching to existing with CT of suitable ratio complete all as specified and directed for the following capacity:-
M&L for filtration of transformer oil for transformers fitted on pole/platform using movable dehydration machine by bringing the machine at site. The job included measurement of dielectric strength of transformer oil before and after filtration. The di electric strength of the transformer oil after filtration must be not less than 40 KV complete all as specified and directed. Note :- The filtration will be done by a machine having suitable capacity.
Supply and topping up of transformer oil in transformer where oil level of transformer is below minimum level complete all as specified and directed. Note :- (i) The dielectric strength of transformer oil must be not less than 40 KV. (ii) The transformer oil to be brought to the site in sealed drum.
M&L for Attending and rectifying any type of external electrical complaints by electrician and helper, disconnection of jumpers, blowing off fuse, breaking of conductor or any other type of fault (HT and LT) in North camp, Tech area , south camp , Happy Home ,71 RMU ,820 SU, Enclave, Begum Bazar , 14 P&SU and other area as directed by engr-in-Charge. Note :-1.The contractor will be responsible for safety, security and upkeep of installation and manpower deployed as per MES standard of installation. 2. All Tools and plants like Plier, Screw driver, tester, test lamps, Multi meter, Bamboo Ladder etc for rectifying the fault occuring in 11 KV/430V/230 V VCBs, 11 KV GODs/DO fuses at Two/four Pole structure and LT Connection from Pole to main DB will be provided by the contractor. 3. All type of minor Part ie rewirable fuse / DO fuse etc shall deemed to be included in quoted rate.4. Each job contains minimum Five complaints. 5. Each Job (minimum Five complaints) done by one Electricin. 6.Complaints will be attended round the clock (day and night) basis as and when recived.
Supply & fixing in replacement of MCCB 630 Amps, 4 pole,breaking capacity 50KA thermal & megnatic adjustable type, 415 volts , 50 Hz .
Supply & fixing in replacement of MCCB 400 Amps, 4 pole, breaking capacity 50 KA at 415 volts , 50 HZ, thermal & megnatic adjustable type.
Supply & fixing in replacement of MCCB 250 Amps, 4 pole,breaking capacity 36 KA thermal & megnatic adjustable type, 415 volts , 50 Hz.
Supply & fixing in replacement of MCCB 160 Amps, 4 pole, breaking capacity 25 KA at 415 volts , 50 HZ, thermal & megnatic adjustable type.
Supply & fixing in replacement of MCCB 100 Amps, 4 pole, breaking capacity 25 KA at 415 volts , 50 HZ, thermal & megnatic adjustable type.
M& L for cleaning the shrubs and vegetation around LT panels including levelling of surface around LT panel complete all as directed and specified by Engineer in charge.
Supply & fixing in replacement of ON Load change over switch 125 Amps, 4 pole,415 volts , 50 Hz, with enclouser type.
Supply & fixing in replacement of ON Load change over switch 250 Amps, 4 pole,415 volts , 50 Hz, with enclouser type.
Supply & fixing in replacement of ON Load change over switch 400 Amps, 4 pole,415 volts , 50 Hz, with enclouser type.
M&L for disconnecting all incoming and outgoing cables from APFC Panels and refreshing all connections by replacement of carbonised lugs including taking out burnt out parts from APFC panels working of contactors MCCBs ,indicators ,wiring kit, capacitor banks all as directed and reassembling and testing for smooth functioning of Relays timers ,and electronic parts complete.NOTE: (i) Cost of lugs,glands,PVC tape and GI nut bolts deemed to be included in the quoted unit rates.
Supply & fixing in replacement of contactor following size.
Supply & fixing in replacement of capacitor bank sylender type any type following size.
(a) 20 to 50 KVR
(b) 20 to 30 KVR
(c) 5 to 15 KVR
Supply & fixing in replacement of DIN type HN Fuse link following size.
(a) 32 to 100 Amp
(b) 125 to 200 Amp
( c) 250 to 315 Amp
(d) 500 to 630 Amp
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
Avion Industries
M/S A M ENTERPRISES
Krishna Enterprises
R.K.ASSOCIATES
M/S R S Traders
Titco Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .