Fabrication, transportation, installation, commissioning and trial run including extension of one no. 1000mm width, 1x90kW, 550 V, single drive belt conveyor along 8R from 72L to 63L in R-VII Seam of LHCM-2 section at 3N4 Incline, J.P. Colly.
2024_ECL_298295_1
ECL/GM/JNR/EnM/A2/23-24/84 dated 10.01.2024
Open Tender
Miscellaneous Works
Item Rate
45 days
JHANJRA UNDERGROUND
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,900
21 Mar 2024
12 Jan 2024
24 Jan 2024
12 Jan 2024
23 Jan 2024
13 Jan 2024
12 Jan 2024 - 19 Jan 2024
Amount
Part A:Fabrication, Transportation, installation, commissioning & trial run of one 1000mm width, 1x90kW, 550V, single drive belt conveyor for a length of 69 mtr from 72L/8R to 70L/8R in R-VII scam.
Fabrication of base frame of drive head at surface
Transportation of the 1000mm width, 1x90kW, 550V Drive Head complete including gear box, motor (90kW/550V), couplings, bearing blocks, fencing etc from surface and installation at 71L / 8R(R - VII) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plate scrappers etc from surface and installation at 72L / 8R(R - VII) with necessary fabrication job.
Transportation and Installation of Loop Take-up Unit Complete, with Fencingfrom surfce and install at 71L/8R
Transportation of Tail End Unit complete with fencing from surface and installation at 70L/8R (R-VII) with necessary fabrication job.
Transportation of 69mtr. 1000mm belt conveyor structure complete with stringer foot stool, top bracket, top & bottom roller etc. from surface to 8R belt installation site and installation from 72L/8R to 70L/8R in R-VII seam.
Loading, transportation and unloading of one faulty starter(550V/90kW), from 78L/9R to surface with help of haulages & 100 mtr manually (Distance- approx. 3800mtr.) for repair.
Loading, transportation and unloading of one breaker 550V / 200 A ) starter (550V/90kW), LS unit from surface to 72L / 8R(R - VII) with help of haulages & 100 mtr manually. (Distance- approx. 3800mtr.)
Laying-hanging of 100mtr 3.3kV grade 70 sq.mm. PVCDWA cable from 73L/8R ACB to 72L/8R ACB manually.
Transportation of 140mtr. 1000mm width PVC belting from surface to 8R(Mirror) belt installation site with help of haulages & 100mtr manually. (Distance-approx. 3800mtr.)
Transportation of 140mtr. 1000mm width PVC belting from surface to 8R(Mirror) belt installation site with help of haulages & 100mtr manually. (Distance-approx. 3800mtr.)
Laying,Lapping,jointing & tensioning of this 140 mtr ,1000 mm width PVC belting in proposed 8R belt
Transportation of 500mtr belt sequence cable from surafce to 72L / 8R(R - VII) then laying-placing them from 78L / 9R starter to 79L / 17R starter in R-VII seam.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8 "X3" MS Bolt-nut) from suarfce to 8R belt installation site with help of haulages for 69mtr. belt and laying-placing them from 72L / 8R to 70L/8R in R-VII seam
Transportation & fitting of 10nos, decking plates at different locations like drive head, discharge, tail end etc.
Testing, trial run, alignment & commissioning of this belt conveyor from 72L/8R to 70L/8R in R-VII seam.
Supply of DA cylinder
Supply of Oxygen cylinder
Supply of M.S. welding electrode
Supply of M.S. Hex. Nut & Bolt (M 16 x 50)
Supply of M30 X 180 H.T. Hex. nut and bolt (For filling of 04 nos. Plummer Blocks of Drive-Driven Drums)
Supply of M30 X 140 H.T. Hex. nut and bolt (For fitting of 01 nos. Motor and 01 nos. Gear Boxes)
Supply of M24 X 120 H.T. Hex. nut and bolt (For fitting of 01 set of FCC-9 Gear Couplings)
Supply of M16 X 65 H.T. Hex. nut and bolt (For fitting of 01 sets of F-140 Tyre Couplings)
Supply of M24 X 150 H.T. Hex, nut and bolt (16 nos. for fitting of 8 nos. Pluntmer Blocks of Loop Drunt, Fixed Drum, and 02 nos, drive, driven Drums of discharge, tal end and 24 nos, as tension screw for total 12 nos. Plummers Blocks)
Supply of M20 X 65 11.T. Hex. Bolts with Nuts (For fabrication of complete Head, Base frame of Cear Box anil Motor, Loop take up init, tensioning arrangement)
Supply of M16 X 50 H.T. Hex. Bolts with Nuts . (For fabrication of complete Head, Base frame of Gear Box and Motor, Loop take up Unit, tensioning arrangement)
Supply of 5 ton trun buckle (for tail end tensioning)
M.S Nut & Bolt(M16X40)
PART B: Seven times extension for a length of 241.5mtr. from 70L/8R to 63L/8R in R-VII seam. Each time belt extension will be for a length of 34.5mtr.
Seven times dismantling of tail end unit complete for seven times belt extension of proposed 8R belt.
Seven times transportation and installation of tail end unit complete for seven times belt extension of proposed 8R belt from 70L / 8R (R - VII) to 63L / 8R (R- VII).
Transportation of 1000mm belt structures (i.e. foot stools, channels, brackets, top and bottom rollers etc.) for a length of 241.5mtr. from surface to belt extension site by haulages and installation them from 70L / 8R to 63L / 8R in R-VII seam during seven times belt extension.*Each time belt extension will be for a length of 34.5 mtr.
Transportation of 490mtr.(approx) 1000mm PVC belting from surface through haulages & 100mtr. manually to 8R(R - VII) belt extension site. (Distance- approx. 3900mtr.)
Laying, Lapping, Jointing & Tensioning of this 490 mtr. 1000mm belting from 70L / 8R to 63L/8R. in R-VII seam during seven times belt extension and trial run.
Transportation of pull cords with its cable, communication devices with its cable signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3"MS Bolt-nut) for 241.5 mtr. belt from surface to 8R belt extension site and laying & fitting them during seven times belt extension.
Shortening of loop take up unit by removing extra belt from loop take up unit
Shortening of loop take up unit by removing extra belt from loop take up unit after every two times extension(2 times more as ( 6/2 i.e approximately 3 times shortening of loop take up unit) as there are 6 nos of extension)
M.S Nut & Bolt(M16X40)
PART C:Civil foundation works for installation of 1X90kW, 550V, 1000mm wide belt conveyer drive head, discharge unit, loop take-up unit and platform for ACB, Starter for proposed 8R belt conveyor of 3&4 incline, JPC.
Recess Cutting in Stone
Cleaning of Debris /Muck
Sand filling
Brickwork with Fly ASH bricks in foundation & plinthin cement mortar 1:6 for starter,breaker
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level :1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
12 mm cement plaster of mix:1:6
Loading material (Bricks, Stone, Sand, Cement) into tub and unloading at site
Roof heightening by drilling, blasting in stone including roof bolting, dressing,cleaning for propsed belt conveyor installationalong 8R between 72L to 70L in RVII seam.
Roof heightening by drilling, blasting in stone including dressing, Cleaning with cost of drill rod and drill bit. (Excluding cost of explosive & detonator).
Roof bolting including carrying of materials from surface to u / g side, drilling, grouting & cost of drill rod and drill bit.
Total impact of GST for the purpose of CTC
N.K. ENTERPRISE
F.R. ENTERPRISE
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .