| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.1 LAccepted-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹96.4 L+₹4.3 L (4.68%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹96.9 L+₹4.8 L (5.25%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
18 Aug 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF HELIPAD LIGHTS SECURITY LIGHT AND OTHER CONNTECTED WORKS AND REPAIR ROUTINE MAINT OF EOT CRANES AT INS SHIKRA UNDER GE NW NOFRA COLABA MUMBAI
2023_MES_606178_1
8200
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (NW) NOFRA
₹1.7 L
Yes
13 Sept 2023
27 Jun 2023
21 Aug 2023
27 Jun 2023
18 Aug 2023
4 Aug 2023
27 Jun 2023 - 11 Jul 2023
Amount
Routine maintinance of Air Field Runway Light System (AFLS) by attending fault testing of system,regularly basis to ensure serviceablity & checking of system etc ,including replacement of unseriviceable component including preventive maintinance spares by replacing parts other than mention in Schedule "A" installed at dispersal area INS Shikra with comprising following:-
(a) Mantinance of runway light circuit no1 and 2 Approx consists of 65 runway lights including repairing & cleaning of lighting system complete.
(b)Maintinance of constant current Regulator (CCR) unit and line stablizer 230 volt,50hz,10 kw,single phase.
(c) Maintinance of Remote control unit at ATC.
(d) Maintinance and Repairing,cleaning and replacement of holder/lamp of flood light fittingred/blue light.
(e) Maintenance and Repairing,cleaning of blue and red light.
(f) Maintinance of obstruction light at any height of building/Hanger etc.
All as per item no 1 above but for Rotating Beacon system. (a) Maintinance of complete Rotating Beacon System Consisting of 3 light assembly including of replacement of lamps/holder/carbon brushes. (b) Maintinance of rotating mechanism for beacon lamps. (c) Maintinance of Remote control unit at ATC.
NOTES :- (a) For item no 1 &2 Schedule & perventive maintinance of the equipment will be carried out as per the publication of the equipment in consultation with BLD department. (b) Highly experience and dedicated Engineer and Technicians having knowledge & fully experienced in Repair and maintinance of runway lighting system shall be deputed to carry out runway light system and cost of the same shall be deemed to be included in the unit Rate quated. (c) Holding of adequate spares parts for runway light shall be kept ready in stock,minimum 25% at site with essential tools for maintinance. Necessary Vrs Shall be submitted by the contractor duly deface by Engineer-in-Charge alongwith RAR, failing which necessay recovery shall be made in respective RAR. (d) On receipt of break down call,the defect shall be attended and rectified on priority with in 01(one) hours. Incase of any such failure,penalty of RS 500/- Per hour shall be recovered (e) Spares part shall be measured & paid under respective items.
Taking down unserviceable LED light and Supply and fixing imported energy efficient and super saver LED 105 Watt,6.6 Amps suitable for helipad identification light (cat No IDM 4062,5000 V) (MAKE- AMA)/ Osram.
Taking down unserviceable LED light holder and Supply and fixing imported energy efficient and super saver LED holder with all acceriors suitable for helipad identification light .
Taking down unserviceable light and Supply and fixing Energy efficent and super saver lamp singlre phase 230 volt suitale for rotating beacon sysytem.Make as per Existng Sample or equivalent as approved by GE.
Taking down unserviceable isolatingn transformer and Supply and fixing Isolating transformer,series to series 200 w, 5000 volts,current ration 6.6/6.6 amps suitable for Helipad identification light (CCR) Light fittings as per sample complete all as directed.
Taking down unserviceable LED light and Supply and fixing LED aviation light luminaires integral LED aviation light comprising of aluminium housing with polycarbonate enclosure,302 nos. LED are provided as per site Required . Location : Helipad sea side and hangers. Make-Bajaj, CAT PART NO-BGAV 302 LED, OR Equivalent to HAVELLs,wipro,CG.
Taking down unserviceable LED lamp 14 Watt aviation and Supply and fixing LED aviation obstruction light yellow/red epoxy flame orange painted die cast auminium alloy housing , hit resistant,clear thick glass and accessories complete. Make : phillips, Jaquar, Havells
Taking down unserviceable wind cone and Supply and fixing wind cone assembly(wind direction indicator) with bottom base plate and stedy burning red obstruction light mounted on top,made of water repellent and resistant to rotating and mildew nylon fasbric with colour combination red and white complete of size dia is 600 mm, the dia of smallend is 300 mm and length is 2.4 mtr. Make shall be of AMA/Mtech system/ctech/cazonil/schenzhenor any other equivalent Make approved by GE.
Taking down/dismantling voltage stablizer of capacity up to10 KVA,415 Volts carefully from its original position and repair & overhauling carrying with fallowing all as specified and directed by Engr -in -charge.
(a) Draining out oil from Voltage Stablizer and dismantling the core connections from tank and taking out core along with winding from tank carefully.
(b) Cleaning the oil tank of voltage stablizer and removing sludges from tank.
(c) Dismantling the faulty winding from the core and re-winding to same with suitable size of insulated copper wire as oer manufacturers specifiocation.
(d) Core shall be assembled with suitable insulated hardware and insulating material varnishing and re-assamling all parts respect to original position etc.
(e) Refilling of new transformer oil and filter to achieve the BDV Values and testing complete all as directed.
(f) Inspecting / overhauling value of spring drive Mechanism by checking mechanism,lever assembly and apply multy grease lubricant to function smoothy.
Taking down old unserviceable junction box and S&F cable junction boxes IP 66/67 weather proof for out door installation(with knock outs cable entry junction box size should be 205 x 255 x 112 with terminals including complete all accessories specified and directed. Make - Sintex , Finolex , Universal , National as approved by
Supply and fix Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners.
Taking down old unserviceable flood lights and supply and fixing 250 watt LED flood light with cast aluminum housing , toughened glass cover, high power LED, second optics , IP 65/66 , 10KV SPD, 100lm/watt, and wired with all accessories. Make : Havells / Philips/ Jaquar
Taking down unserviceable LED light and Supply and fixing 120 WATT LED high/midbay:corvus series intergral industrial high power LED High/midbaywith pressuredie cast alluminium housing anodrisedaluminium reflector at any complete with all acessories. Make-Havells, /Phillips/Jaquar
M&L for scraping the old Painted surfaces and spray painting of LT Pole any size with two coat of synthetic enamelled paint of approved colour complete with all fitting etc all as specified and directed by Engr in charge.
M&L for scraping the old Painted surfaces and spray painting of red/ yellow /blue and flood flight poles lights around of halipad any size with two coat of synthetic enamelled paint of approved colour complete with all fitting etc all as specified and directed by Engr in charge.
Taking down unserviceable aluminium XLPE cable and Supply and fixing copper cable XLPE armoured Insulated screened PVC bedded, galvanized electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10 Sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as directed. Make : Polycab / Finolex/ Havells Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down unserviceable aluminium XLPE cable and Supply and fixing copper cable XLPE armoured Insulated screened PVC bedded, galvanized electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 16 Sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as directed. Make : Polycab / Finolex/ Havells Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down unserviceable XLPE cable and Supply and fixing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed. Make : Polycab / Finolex/ Havells Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down unserviceable XLPE cable and Supply and fixing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed. Make : Polycab / Finolex/ Havells Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down aluminium cable and Supply and fixing copper cable 4 sqmm 2 core PVC round sheathed insulated Unsheathed copper conductor industrial cable voltage 1100 volt for connection junction box to light. Make : Polycab / Finolex/ Havells/ HPL
Taking down aluminum cable and Supply and fixing copper cable 2.5 sqmm 2 core PVC round sheathed insulated Unsheathed copper conductor industrial cable for voltage 1100 volt . Make : Polycab / Finolex/ Havells/ HPL /Plaza
Taking down unserviceable DB and Supply and fixing Distribution Board single door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 30 & IK 08 protection surface mounting SPN 2 way, 240 volts ,dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand /Havells/Schnider/ siemens/GE.
Taking down/dismantling UPS of capacity 04 KVA to 5 KVA,415 Volts carefully from its original position and repair & overhauling carrying with following all as specified and directed by Engr -in -charge.
(a) Replacement of capacitor 4700MFD/450 Volt,10MFD/440VAC.
(b) Replacement of connector 2 way/60A,3 Way/60 Amps,4 way/60 Amps.
(c) Replacement of display digital meter.
(d) Replacement of fuse igbt 75A/600 volt
(e) Replacement of relay 30A/12/1
(f) Replacement of shunt 75 mv/50Amps.
(g) Replacement of module & Sensing X"MER Charger 19-0-19(440 volt),inverter 7-0-7(230 volt),Display 13-0-13(230 volt)
(h) Replacement of Current Transformer CT25A Double CON
(j) Replacement of tranformer,inverter tx 130v/260v,DC Choke 1.5MH/35A
(k) Replacement of PCB,Charger 3 phase,dc card,combo card front display meter card,divider card.
(l) Replacement of Display sticker,isolate terminal,fuse holder,Registor 1k/20 w,spot switch,buzzer,3 way box connect etc
As per above item ser No 103 bur 2 and 3 KVA UPS directed by Engr -In Charge.
Taking down unserviceable MCB SPN and Supply and fixing MCB,SPN 40 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make-Legrand,siemens,GE
Taking down unserviceable light and Supply and fixing Ceiling light 36 WATT 2 ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel. Make- Philips/ Havells/ Jaquar
Taking down unserviceable and Supply and fixing CPT Cirprotec CPT-L ESE lightning rod with stainless steel body Type Advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of Early Streamer Emission technology which will offer Level 1 protection for up to 30 Mtrs Mtrs radius when mounted on the RCC concrete base on Building at a height of 4.5 mtrs from the place to be protected complete all as directed by Engr-in Charge. Make : NIMBUS-JEF Techno / V. perfect or equivalent make approved by GE.
Taking down unserviceable mounting str and Supply and fixing mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on Building complete all as directed by Engr-in Charge
Taking down unserviceable copper conductor and Supply and fixing of 1X50 sq mm copper conductor with 0.5 mm thick PVC sheathed cable complete all as directed by Engr-in Charge.
Taking down unserviceable digital lighting and Supply and fixing 4 digital electromechanical lightning event counter in weather proof resistance complete all as directed by Engr-in Charge.
Supply and fixing of test Link for connecting the earth pit and down conductor complete all as directed by Engr-in Charge.
M & L for maintainance free enviroment friendly earth electrode set comprising of 17.2mm dia,3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro ohms, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) complete all as directed by Engr-in Charge. Make : NIMBUS-JEF Techno / V. perfect or equivalent make approved by GE.
Taking down unserviceable LED light and Supply and fixing LED Bldg security light 120 watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens ,INDUS SERIES. make- /Phillips/Jaquar HAVELLs
Taking down unserviceable LED light and Supply and fixing LED Bldg security light 45 watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens ,INDUS SERIES. make-Phillips/HAVELLs,
Taking out old unserviceable Lt panel. Supplying and fixing testing and commissioning weather and vermin proof factory made manufactured by a CPRI approved factory, floor mounted, out door cubicle type double door totally enclosed LT panel fabricated out of 3 mm thick CRCA sheet with extended hood to arrest rain beat with MS angle iron frame made out of angle iron 45 x 45 x 6 mm suitable for operation on 3 phase 4 wire 415 volt 50 HZ system, dust & vermin proof, front and rear operated, hinged panel doors covers two sides openable with handles , locking arrangements and consisting of sufficient number of cable cutting holes at bottom for inserting incomming /out going cables ith suitable PVC /Rubber bushes to arrest entry of water /vermin etc and fixed with chromium plated brass cable glands to connect the cables of suitable sizes internal power wiring, adequat aluminium strips for bus bars and stranded copper cables size suitable to the capacity of MCCBs an other controls including internal compartnets using 3 mm thick CRCA sheet metal powder coated connecting all cabales properly and consisting of the following controls and fitment in LT panel complete all as directed by Engineer - in -charge Loc : ATC Ground floor
INCOMING (a) MCCB 250A, rated for 415Volt, 4 pole, 3 Phase, rupturing capacity of 36KA, Thermal-Magnetic type MCCB, Qty-01 No (. incoming ), the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. (Thermal adjustment and magnetic adjustment setting) (b) Bus bar of aluminium strip of suitable cross section to with stand 250 Amps rating 3 phase and half of the phase capacity for neutral mounted on Epoxy/FRP bus bas insulator and colour coding
Taking down old unserviceable MCCB ans supply and fixing MCCB, 415 volts, 3 pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand / siemens/GE/Havells/L &T
Taking down old unserviceable MCCB and supply and fixing MCCB, 415 volts, 3 pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections including necessary fitting and fixture alongwith addition/alteration LT panel at site complete all as directed. Make - Legrand / siemens/GE/Havells/L &T
S&F HDPE of Pressure rating 6kg/cm sq pipe of 63 mm dia including necessary bends,elbows,Tees etc on cable protection complete all as directed.
Taking down old unserviceable MCCB and supply and fixing of MCCB sheet metal enclosure suitable for holding MCCB of 100 amp capacity four pole type including necessary fitting and fixture alongwith addition/alteration LT panel at site complete all as directed. Make - Legrand / siemens/GE/Havells/schneider
Taking down old unserviceable MCCB and supply and fixing of MCCB sheet metal enclosure suitable for holding MCCB of 160 amp capacity four pole typeincluding necessary fitting and fixture alongwith addition/alteration LT panel at site complete all as directed. Make - Legrand / siemens/GE/Havells/schneider
Taking down old unserviceable MCB ans supply and fixing 100 Amps Triple pole and earth encolsure with a three pin and earth plug with socket complete with one single pole MCB. Make - Legrand / siemens/GE/Havells/schneider
Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25x4 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type C2 and Cast iron pit cover, watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion.
Taking down old unserviceable MCB and supply and fixing MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed .make: Havells /Legrend ,legrand / Siemens,schneider
Taking down old unserviceable MCB and supply and fixing MCB, SPN, 63Amps capacity, C Curve type suitable for 415 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. make: Havells /Legrend ,legrand / Siemens,schneider
Taking old rusted stand post of 250 watt flood light. Supply and fix GI tubes medium grade of 80 mm dia ( 01 mte length for each light) and including cut in piece , welding, nut , bolts, washers,iron plate etc, grouting in ground and fixing of plain 5 mm thick angle iron bracket for holding of GI pipe & 250 mm flood light to be fixed on GI Pipe complete all as specified & directed.-
Disconnect electric connection and taking out existing service cable from the cable duct and taking out cable duct cover , cleaning sand /mud /other items after cleaning reconnect the service cable and checking electric supply in each helipade lights complete all as directed by Engineer -in-Charge Note : Cable duct around helipad area and H1 & H2 lights duct.
Supply and fixing in replacement equal 50 x 50 mm angle iron 4 mm thick and including cuting welding , fixing to wall / floor for laying/ fixing of cable tray on it with nut and bolts ,washers etc complete all as directed by Engineer -in-Charge
Securing of hanging and loose electrical cable & taking up loose cable from wall, pole , roof and refixing XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cables upto 06 Nos of sizes from 06 Sqmm 2 Core to 185 Sqmm 3.5 core complete fixed on wall pole , roof properly with suitable Plastic strep cable Zip ties nylon self locking wire ties black 250 mm and galvanised 'U' clamps with anchor fastner or saddles and screws all as specified and directed.
Supply and fixing Mild Steel Galvanized Coating Powder Coated Cable Tray vantilatted channel type single compartment of size 300 mm x 38 mm x 2.0 mm for carrying of LT cable of suitable size fixing on wall/ angle iron along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge.
Taking out old unserviceable UPS and Supply and fixing UPS (inverter) 3 KVA /96 VDC single phase AC input 160 to 260 V . (a) Isolation transformer for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% - 01 No (b) 30 Miniuts backup 12 Volt 42 AH SMF batteries with battery links - 08 Nos Make Exide/Amron (c) Stainless steel battery rack with links, nut, bolts etc with all accessores for fixing of 08 Nos of battery - 01 No . Make Of UPS : Addon/Recom/Luminous/Microtek
Taking out old unserviceable UPS and Supply and fixing UPS (inverter) 5 KVA /180 VDC three phase AC input 300 to 450 V. (a) Isolation transformer for 30 min back up single phase AC input 300 to 450 V and out put 230 ± 1% - 01 No Make Exide/Amron (b) 30 Miniuts backup 12 Volt/ 26 AH SMF batteries with battery links - 15 Nos Make : Exide/Amron (c) Stainless steel battery rack with links, nut, bolts etc with all accessores for fixing of 15 Nos of battery - 01 No. Make Of UPS : Addon/Recom/Luminous/Microtek
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm
Supply & fix in replacement hot dip galvanized anti corroded weather proof octagonal wind sock pole 7 mtrs long with 1500 mm long 04 Nos Arms bracket, tapper plug,bolts nuts and screws etc top mounting and foundation complete with base plate and final including PCC foundation as per manufacturer design complete all as specified and directed including taking out existing damaged pole . Loc : Sea side Delta Post
PCC 1:3:6 type C2 (using 20 mm graded crushed stone aggregate) for plingth protection of cable tray angle and flood light GI pipe 80 mm dia complete all as directed by Engineer -in-Charge
Supply & fix LED Taxiway Edge lights with 230 volts fitting as per sample /requirement / existing modal/ make directed by Engr-in -charge
Taking down Old Unserviceable battery and supply and fixing new SMF battery having 30 Miniuts backup 12 Volt 26 AH SMF batteries with battery links . Make Exide/Amron
Taking down old siren and supply and fixing heavy duty industrial siren 1.5 km range, 220 volts AC supply and 6000 RPM with all accesoorries all as directed by Engr-in-Charge. Make Kheraj/ Electrical, Agni
Taking down unserviceable helipad light and Supply and fixing helipad light IN -OMH on indentificational medium intensive inset light ICA : Annex 14 volume , Fan : AC 130/5390-23, NATO : Stanag 3652 , Cap : 160, BS : 3224 and technical charrcteristics as under :- (a) Lamp: 50 watt/12Vac per focussed halogen lamp with an integral alchroic coated 50 mm rectification lamp grater than 4000 hours. (b) Power Supply : 240 Volt AC, 50/60 Hz or 6.6 Amp with two copper cable for supply (c) Photomamory : Distrubution and homogeneity complete with ICAO 14 Volume L (d) Colour : white or green alchroic filters ovomaticity with transmission factors (when height , white- 0.04 and green - 0.55 (e) Finish : all esternal parts are made of anodised termpreture aluminium alloy casting all fitting and fixtures stanless steel. (f) Accessories : External diameter - 215 mm , Weight - 05 KG , IP - 67, priojectio - 10 mm and shallow depth 100 mm with shallow base
Taking down unserviceable LED light from helipad and Supply and fixing aviation obstruction light yellow/red/ Blue colour die cast auminium alloy housing ,bulit in 75 VA step of transformer,hit resistant,clear thick glass and accessories complete with neon lamp 75 VA with provision of necessary GI pipe and base for fixing Make : Phillips,Bajaj,CG. AMA and as per sample
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm
Supply and fixing industrial solution with insulated plug & socket, steel metal plug 63 Amps with 02 ple MCB, earthe connector wire and socket with 3 pin front side threded cover and locking arrangement directed by Engr-in-Charge. Make : Havells/ L&T/ Legrand
Material and labour for servicing of over head traveling crane complete including checking / tighting of all nut , bolt & breaks any type any size complete system, adjustingetc of all breakes motions and VFD adjustment setting as per load testing run of flame proof / non flame proof/ normal type EOT / HOT cranes with having single or double girder type and providing greasing & oiling of traving / moving parts of crane with connecting motor girder parts for movment of crane hoist / long / cross traveling and including maintained the controlling of speed / creeping micro speed of motors with minor maint / repair the electrically operated main control panel wire with connecting control wiring system consisting of main switch, step down transformer, contactor, HRC fuse, VFD,PLR,control pendent ,wire rope with break drum unit, gear box unit , oil levels,motor bed / foot ,electrical control cable, motor terminal, end cable carriage trolly,motor shaft, bush flange bearing with lathe work ,chain pully block, rachet cluch,gear block,chain wheel, chain etc and including locating the defected fault and rectification of the fault and rectification of oil leakage etc any type any size and replacement of difected nut, bolt & washer and making it sound less proof and after trails testing run of crane for smooth functional / operation for the following mentioned capacity cranes complete all as specified and directed
Note- Periodic inspection/servicing, to be carried out in every three months and making/keeping the cranes serviceable, for EOT/HOT cranes of rating load 1 Ton to 02 Ton capacity installed in various locations, including the properly checks as mentioned as efollowing:- (i) LONG TRAVEL MOTION AND CROSS TRAVEL MOTION (a) Checking Gear box oil level and filling with required oil and rectification of leakages if any.(Note: Gear Oil shall be measured and paid separately as supply only) (b) Brake adjustment (c) Checking of long travel & cross travel wheel for any noise/malfunctioning.(d) Checking grease of geared couplings, complete nut, bolt work for tightening and replacement of grease nipple. (e) Checking of oil in Hydraulic thruster brake, rectification of leakages if any and filling with required quantity of oil.(Note: Brake Oil shall be measured and paid separately as supply only) (f) Checking of electric motor connections, insulation resistance value etc (g) Checking the cut-off at extreme ends with the limit switch. (j) Checking and greasing of shaft pedestal. (ii) HOIST MOTION (a) Checking gear box oil level and filling with required oil and rectification of leakages if any.(Note: Gear Oil shall be measured and paid separately as supply only) (b) Brake adjustment (c) Checking of main bearings of the rope drum including greasing the same (d) Checking grease of geared couplings and nut tightening. (e) Checking of oil in hydraulic thruster brake, rectification of leakages if any and filling with required quantity of oil.(Note: Brake Oil shall be measured and paid separately as supply only)
(f) Checking of electric motor connections, insulation resistance value. (g) Checking wire rope for any damage & greasing the rope. (h) Adjustment of the rotary limit switch. (j) Checking of bearing of the hook and greasing the same. (iii) ELECTRICAL PANEL (a) Checking the contactors for overheating or flashing. (b) General checking of contacts and connections. (c) Cleaning of control panels and checking of connections. (d) Checking of connections of VVVF drives/other drive, calibrating VVVF drive and PLC to get smooth movement & maximum efficiency / other drives for smooth functioning of the same. (e) checking the serviceability of cable including power/control cable, checking the serviceability of cable carrier/cable trolleys ,adjusting as possible to get maximum free for movement of moving part/ Aprons of EOT cranes (iv) DOWN SHOP LEAD (a) Checking the alignment and rectification. (b) Cleaning of the moving/sliding objects.
EOT crane of capacity 1 Ton
EOT crane of capacity 2 Ton
EOT crane of capacity 10 Ton
Providing material and labour for load testing of over head traviling crane of capacity 1 Ton EOT crane as per manufacture norm for safe working rating load including arrangment of dead load measurement unit with link steel wire rope and requred suitable load for testing with duly varying the load upto 110% of the rated capacity load of crane including trasporting to testing load at difference location and also providing load test certificate in triplicate set from authorised crane inspector duly signed by inspector authority of crane complete all as specified and directed
Providing material and labour for load testing of over head traviling crane of capacity 2 Ton EOT crane as per manufacture norm for safe working rating load including arrangment of dead load measurement unit with link steel wire rope and requred suitable load for testing with duly varying the load upto 110% of the rated capacity load test certificate in triplicate set from authorised crane inspector duly signed by inspector authority of crane complete all as specified and directed
Providing material and labour for load testing of over head traviling crane of capacity 10 Ton EOT crane as per manufacture norm for safe working rating load including arrangment of dead load measurement unit with link steel wire rope and requred suitable load for testing with duly varying the load upto 110% of the rated capacity load test certificate in triplicate set from authorised crane inspector duly signed by inspector authority of crane complete all as specified and directed
Supply and fixing in replacement of power contactor 3 phase MNX series /Freedom Series type or as per existing sample / model of rated capacity 16 Amp to 32Amp 415 volts along with suitable rating of NC/NO type Auxilary contactor block complete all as specified and directed. Make : MEC/BCH/ ABB/ L&T /Siemen/Schnieder/C&S
Supply and fixing in replacement of power contactor 3 phase MNX series /Freedom Series type or as per existing sample / model of rated capacity 12Amp to 15Amp 415volts along with suitable rating of NC/NO type Auxilary contactor block complete all as specified and directed. Make : MEC/BCH/ ABB/ L&T /Siemen/Schnieder/C&S
Supply and fixing in replacement of power contactor 3 phase MNX series /Freedom Series type or as per existing sample / model of rated capacity 6Amp to 9 Amp 415volts along with suitable rating of NC/NO type Auxilary contactor block complete all as specified and directed. Make : MEC/BCH/ ABB/ L&T /Siemen/Schnieder/C&S
Supply and fixing in replacement of unserviceable dynamic breaking resistance (DBR) device of rating / model 180R 1K2W or 180EJ 1200W type or as per existing sample / model suitable of oprating operating of over head traviling for 2 Ton EOT crane complete all as specified and directed. make :Yesdee/Stead/ /Onics or equivalent model and make
Supply and fixing in replacement of single phase preventor of type VSP 2 / VSP3 or as per existing sample/ model type with having system AC supply 415 volt 50 HZ complete all as specified and directed by Engineer-in-Charge. Make : - Minilac/indo power/Bintex
Material and labour in replacement of step down transformer with having rating 440 volt to 110 Volt A.C upto 30 VA capacity or as per existing size/ rating and complete all as specified and directed
Supply and fixing in replacemet with flushing/ topping of gear box oil SAF-90 grade type suitable for OHT crane LT, CT, Hoist system of gear box complete all as specified and directedmake : Indian oil corporation /H.P./B.P./Bharat/servo/castrol
Supply and fixing in replacemet with flushing / topping of transformer oil suitable for OHT crane thruster brake assembly system complete all as specified and directed. make : Indian oil corporation /H.P./B.P./Bharat/servo/castrol
Supply and fixing in replacement of cable carrier reel system suitable for 2.0 Ton EOT crane complete all as specified and directed. make : Albrasco/ Meagtech/Vimal
Matrerial and labour for taking down of unserviceable motor from OHT crane and including transporting and re-winding of electric motor of capacity 2HP, 3 phase 415 volts, with supper enameled copper conductor wire as per existing size/gauge including making varnishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed
Matrerial and labour for taking down of unserviceable motor from OHT crane and including transporting and re-winding of electric motor of capacity 3HP, 3 phase 415 volts, with supper enameled copper conductor wire as per existing size/gauge including making varnishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed
Matrerial and labour for taking down of unserviceable motor from OHT crane and including transporting and re-winding of electric motor of capacity 5HP, 3 phase 415 volts, with supper enameled copper conductor wire as per existing size/gauge including making varnishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed
Matrerial and labour for Painting of EOT / HOT Double girder traveling over head travaling EOT/HOTcranes system along with trolly, foot parth , railing system and including both sides girder and its connected item fixing accessories / equpts complete for crane system by appplying two coats of flame proof paint of colour golden yellow /Tractor orange/ gray colour or existing sample with exising making painting as per existing type colour code with providing painting of synthetic Ist quality paint after scrapping of old rusted surface and cleaning of oil and greas , soil dust partical material by manually with sand paper suitable for capacity of 1 Ton to 10 ton crane (Span not more than upto 20 Mtrs & Guarder length not more than upto 25 mtr long) complete all as specified and directed
Supplying and fixing in replacement of star/stop controller push bottom with electric terminal connetor block/ elements (NO/NC type) as per existing sample /size suitable for crane complete all as specified and directed. Make -BCH/Technique/L&T/ Vaishnow /telemecnic/C&S/
Supplying and fixing in replacement of main emergency star/stop bottom with electric terminal connetor as per existing sample /size suitable for crane complete all as specified and directed
Supplying and fixing in replacement of electric terminal connetor block/ elements (NO/NC type) as per existing sample /size suitable for crane complete all as specified and directed. Make -BCH/Technique/L&T/ Vaishnv /telemecnic/C&S/
Supply and fixing in replacement of unserviceable rubber buffer as per existing sample/type suitble for 1 Ton to 10 Ton EOT crane complete all as specified and directed
Material and labour for in taking down and repair of existing thruster brake assembly unit and including rewinding of thuster brake unit as per existing type / gauge of winding matterial and replacement of oil seal with connecting fixing accessories as per existing sample/ model suitable for 1 Ton to 10 Ton EOT cranes and testing on load complete all as specified and directed
Supply and fixing in replacement of unservicble worm out electromagnetic flame proof thuster brakes set suitable for holding the pressure up to 18 Kg/Cm2 or as per existing sample/type along with connecting fixing accessories as per existing sample/ model suitable for 1 Ton to 10 Ton EOT cranes complete all as specified and directed
Supply and fixing in replacement of unserviceable bushed / ball bearing as per existing sample/ model suitable of oprating of traviling system for 1 ton to 10 Ton EOT crane complete all as specified and directed
Supply and fixing in replacement of unserviceable flanged type wheel ball bearing as per existing sample/ model suitable of operating of traviling system for 1 ton to 2 Ton EOT crane complete all as specified and directed. Make :SKF/NBC/ or equivalent model and make
Supply and fixing in replacement of unserviceable metal body flame proof weather proof rotary gear type limit switch assembly with having IP 65 protection as per as per existing sample/ model suitable for safe working oprating of up / down operating motion/hoisting system for EOT crane of capacity 1 Ton to 10 Ton complete all as specified and directed. Make Shyaam /Sudhir/ SKF/ SIEMENS/ Mascot/ Bharat/Duplex/Baliga/Rolex
Supply and fixing in replacement of unserviceable metal type flame proof weather proof junction box as per existing sample/ model/ make suitable for safe electric wire connection system for upto 10 Ton EOT crane complete all as specified and directed. Make Shyaam/Sudhir/ Bharat
Supply and fixing in replacement of flame proof suspension type pendent/hanging controling unit controlling unit with flame proof start/stop push buttons with indicator lamp and emergency control switch, lifting hook for UP and down, long travel motion, cross travel and conneting to controling micro speed panel suitable for safe and smooth operating system of EOT crane of 1 ton to 2 Ton capacity including making cable connection and testing complete all as specified and directed. make: BCH/ Shyam/Sudheer or equivalent model and make
Supply and fixing in replacement of unserviceable gear box oil seal, cover paking seal , gear box ball bearing etc or other defected connecting parts as requred at site as per existing sample/type and making it oil leak proof and sound less proof complete and including testing on load of 2 Ton EOT crane complete all as specified and directed
Dismantling of existing reduction gear box with device for hoist/CT/LT motion traverse for EOT cranes of load 1 Ton to 02 Ton capacity and carrying out replacement of following unserviceable Parts / Carrying out misc repair and refixing the gear box after checking alignment of brake drum & motor and motor & gearbox , in existing position, complete all as specified and directed:- (a) Replacing the worn out shaft seals & bearing (b) Replacement of internal cover gasket, (c) Replecment of Gear coupling with nuts & bolts complete.
Supply and fixing of Electro Hydraulic thruster mounting assembly complete suitable for mounting of 34 Kgs size/ capacity Hydraulic thruster all as existing type with nut, bolts etc including dismantling and removing old unserviceable thruster assembly for 02 Ton EOT Crane. complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Material and Labour for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC Casing/Caping of suitable size, ISI marked with accessories concealed in wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for the following :- Make of cable ; Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
One light point controlled by one switch SP one way.
One ceiling fan point controlled with one 5A switch
One exhaust fan point controlled with one 5A switch
One 3 pin socket outlet 5Amps on independant board.
One 3 pin socket outlet 5Amps on same board with other switches.
One bell point controlled by one bell push 5 Amps.
One 3 pin socket outlet 15 Amps on same board with other switches.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through & including PVC Casing/Caping of suitable size , ISI marked with accessories concealed in wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes conealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. Make of cable ; Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of cable ; Polycab, Finolex, Havells. Make of casing & capping : Precision, Supreme, Pressfit
Supply and fixing Modular Switch , 6Amp, One way, 1 module, ISI marked Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular Switch , 16Amp, One way, 1 module, ISI marked Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular Socket , 6 Amps, 2/3 pin combined 3 module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular Socket , 16Amps, 6 pin combined 3 module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular type bell push , 6Amp, 1 module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Bell electric AC 230Volt single pole musical type, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular type, electronic fan regulator ( 5 step ),450 Watts, 230 volts, 2 module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fixing Modular white cover plate with Frame 2 Module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular white cover plate with Frame 3 Module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular white cover plate with Frame 4 Module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular white cover plate with Frame 6 Module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular white cover plate with Frame 8 Module, ISI marked. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular white cover plate with Frame 12 Module. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fixing Modular metal flush box 2 module, ISI marked.
Supply and fixing Modular metal flush box 3 module, ISI marked.
Supply and fixing Modular metal flush box 4 module, ISI marked.
Supply and fixing Modular metal flush box 6 module, ISI marked.
Supply and fixing Modular metal flush box 8 module , ISI marked.
Supply and fixing Modular metal flush box 12 module, ISI marked.
Supply and fixing baton integral sleek extruded polycarbonate LED channel with white acrylic cover of 1x18WH with accessories internally prewired and incl connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Philips/Jaquar
Supply and fixing baton integral sleek extruded polycarbonate LED channel with white acrylic cover of 1x20WH with accessories internally prewired and incl connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Philips/Jaquar
Supply and fixing baton integral sleek extruded polycarbonate LED channel with white acrylic cover of 1x10 WH with accessories internall prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Make: Havells/Philips/Jaquar
M&L for Lamp holder, PVC/ Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by engr-in-charge.
Supply and fixing LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply. Make: Havells/Philips/Jaquar
Supply and fixing 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make: ABB, Siemens /Schneider/ GE/ Legrand
Supply and fixing MCB, DB, SPN 8 way double door with protection type IP-42 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed. make Siemens /Schneider/ GE/ Legrand
M&L for sheet metal enclosures for DB 2 way with 100 amp rated busbar of 240 V . Make: ABB, Siemens /Schneider/ GE/ Legrand
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply and fixing Submain wiring with proper colour coding, 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping of suitable size, ISI marked including 1 single core cable with stranded copper conductor of size 4 Sqmm (green colour) for earthing complete all as specified and directed. Note : 2 runs of 4 Sqmm cable, 1 run of PVC Conduit and 1 run of 4 Sqmm cable shall be measured as 1 Run.
do but As item No 65 but 06 Sqmm sub main
do but As item No 65 but 10 Sqmm sub main
Taking down old unserviceable MCCB .Supply and fixing MCCB, 415 volts, 4 pole of cap DPX 630 Amps, 50 KA, ICS = 100% ICU complete all as specified and directed. Make : L &T / Legrand /Strandred/HPL or as per existing make at site.
Taking down old unserviceable MCCB .Supply and fixing MCCB, 415 volts, 3 pole of cap 400 Amps, 50 KA, ICS = 100% ICU complete all as specified and directed. Make : L &T / Legrand /Strandred/HPL or as per existing make at site.
Taking down old unserviceable street light of any capacity from existing pole /truss of any size and height and fixing only flood light / street light of any capacity compolete all as specified and directed. Streel light issued by deptt.
S&F in Replacement LED driver for street light / highbay light fitting / flood light upto 45 watt to 120 watt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaquar
S&F in Replacement LED driver for street light / highbay light fitting / flood light 150 watt to 250 Watt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge. Make:- Havells /Philips / Jaqua
Material and labour for cleaning all dust filling cavities with filler, prepartation of surfaces, painting of ceiling fans , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed . Make : Asian Apoclite, Berger, Nerolac Hi Gloss
Material and labour for cleaning all ldust filling cavities with filler, prepartation of surfaces, painting of Exhaust fan , air circulator, wall mounting in situ with one coat of synthetic enamel paint by spray painting complete all as specified ;and directed . Make : Asian Apoclite, Berger, Nerolac Hi Gloss
M & L for rewinding of unserviceable ceiling fans lof size 1200/1400 sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing split/ quarter pins, rubber bush, capacitor 2.5 Mfd and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
M & L for rewinding of unserviceable exhaust fans lof size 225/300/450/630mm sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing nut bolts pins, rubber bush, capacitor , bearing ,m bush, frastner etc and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans. Make NBC, SKF
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans. Make NBC, SKF
Repair of Earthing pit. Taking out old broken and damaged pit cover and PCC frame complete and refix new RCC fram and cast iron pit cover and connect old uproted aluminium strip to equipment/earth test piont including excavation returning filling all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
Shree Ayyappa Engineering
Darpan Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .