Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹87.4 CrAdmitted-Finance B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | -18.10% | ₹87.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹92.3 CrAdmitted-Finance | -13.51% | ₹92.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹93.0 CrAdmitted-Finance 1C 1D VINDHYA TELELINKS LIMITED UDYOG VIHAR REWA MADHYA PRADESH 486006 | REWA | MADHYA PRADESH | 486006 | -12.80% | ₹93.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹94.8 CrAdmitted-Finance | -11.12% | ₹94.8 Cr | L4 | Admitted-Finance |
Tender Value
₹106.7 Cr
EMD Value
₹1.1 Cr
Closing Date
22 Apr 2026, 5:00 pmClosed
Superintending Engineer
Office of The Superintending Engineer, Construction Circle, U.P. Jal Nigam (Urban), Varanasi.
Survey Soil investigation, Design, Supply of all materials etc. Required for construction of Over Head Tanks, CWR, Tube well, Pump House, SCADA room, Rising Main, Distribution Network, House connection, Boundary wall, MS gate, SCADA automation etc.
2026_UPJNM_1129114_1
498/08-081-005/124 Dt. 20.03.2026
Open Tender
Civil Works - Water Works
540 days
Nagar Nigam Varanasi
As per Tender Notice and Tender Document.
2 documents required · 2 mandatory
₹23,600
E E CD II UPJN (Urban) Varanasi
₹1.1 Cr
Varanasi
11 Jun 2026
23 Mar 2026
23 Apr 2026
23 Mar 2026
22 Apr 2026
23 Mar 2026
1 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Civil Work | ||||||
| 1.01 | OVERHEAD TANKS | - | - | - | - | - |
| 1.02 | Investigate the soil bearing capacity by only nationalised institute and If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. Design, Supply of all materials labour T&P etc. required for complete construction of R.C.C. Over Head Tank of following capacity and staging as specified in bid document as per direction of Engineer-in-charge. The key feature, but not limited to, pertaing to design and construction of OHT are as follows:
1. The finished floor level of OHT shall be min 0.3m above the finished ground level of the campus.
2. Soil investigation and bearing capacity.
3. Structural design and drawing confirming to IS: 456, IS: 3370, IS: 1893, IS: 875 & Other relevant IS Code.
4. Grade of concrete M30 for water retaining structure and concrete grade for other components shall not be less then M25.
5. Saprete two column based RCC stair case of width minimum 1m.
6. 1m wide R.C.C. M30 balcony, SS ladder inside the tank from top dome to bottom dome shall be made of 50x50x6 mm angle section with hand rails of 20mm SS pipes. The grade shall be SS 316.
7. Railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m.
8. Proper ventilator at top dome in circular shape of 1.2 m dia. | - | - | - | - | - |
| 1.03 | 9. Food Grade epoxy coating of FOSROC / Ciba-Geigy or reputed brand on inside surface area of water container after testing of water tightness, two coat of apex painting over one coat of primer of approved colour after finishing of RCC surface with grinder.
10. Repairs of pin holes, unevenness of all concrete surface.
11. Ultra Sonic Water level indicator fabricated with sensor connecting to automation
12. Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309‐1969 and ISS 3013‐1966.
13. C.I. manhole of min 60x60cm size with locking arrangement.
14. Supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout with Bell Mouth as per latest / relevant I.S. specifications with all jointing materials for proper completion of work. 15. Construction of 120mm thick RCC floor in 1:1.5:3 with cement, coarse sand, approved stone grit and reinforcement t@8mm dia @250mm c/c both way over 100mm thick PCC 1:4:8.
16. Supply, fixing of D/F Sliuce Valve with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specifications with all jointing materials for proper completion of work.
17. Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing. | - | - | - | - | - |
| 1.04 | 18 . Supply of 200 mm dia PVC pipe for disposal of water from washout chamber to suitable point outside the water works compound.
19 .MS steel box type enclosure of at the entrance of the staircase having locking arrangements.
20 .The C.I (D/F)pipe dimensions for inlet,outlet,washout,overflow will be decided as per site requirements. For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determined after soil investigation / 8 tonne/sqm Note :- The bid price of Over Head Tanks is to be submitted considering that the design of over head tank will be done by retired / working Associate proffessor of any IIT and it shall be vetted by a working professor also of IIT and The net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work. | - | - | - | - | BI01010001010000000000000515BI0100001112 |
| 1.05 | Construction of R.C.C. Over Head Tank 1200 KL/25 mtr including all Materials, Labours, T & P etc. Complete. For Zone-2 | - | Nos | - | - | BI01010001010000000000000515BI0100001113 |
| 1.06 | Construction of R.C.C. Over Head Tank 1300 KL/25 mtr including all Materials, Labours, T & P etc. Complete. For Zone-3 | - | Nos | - | - | BI01010001010000000000000515BI0100001118 |
| 1.07 | Construction of R.C.C. Over Head Tank 1300 KL/23 mtr including all Materials, Labours, T & P etc. Complete. For Zone-4 | - | Nos | - | - | - |
| 1.08 | Construction of R.C.C. Over Head Tank 1100 KL/25 mtr including all Materials, Labours, T & P etc. Complete. For Zone-5 | - | Nos | - | - | - |
| 1.09 | Construction of R.C.C. Over Head Tank 1200 KL/27 mtr including all Materials, Labours, T & P etc. Complete. For Zone-6 | - | Nos | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.50 MB
BOQ_2106242.xls
BOQ • 0.68 MB
Lamhitenderdoc.pdf
Tender Documents • 10.16 MB
Download all tender documents and submit your bid