Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC C O SIMPLICITY LYNGDOH LOWER LUMPARING LABAN SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹24.1 L+₹15,750 (0.66%)Rejected-Finance RONGMEN BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹25.3 L+₹1.4 L (5.66%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹26.6 L+₹2.6 L (10.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹28.7 L+₹4.7 L (19.7%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23.9 L
EMD Value
₹47,800
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
SPL REPAIR AND ADDN ALTN TO SEWAGE LINE, SEPTIC TANK, SOAKAGE WELL AND PATH AT JTN UNDER GE UMROI
2024_MES_640797_1
8769/E8
Open Tender
Civil Works
Item Rate
180 days
Umroi
As per NIT
8 documents required · 8 mandatory
₹500
GE Umroi
₹47,800
1 Apr 2024
5 Feb 2024
27 Feb 2024
5 Feb 2024
26 Feb 2024
19 Feb 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and directed.
All as per item No 01 above but exc 1.5m dapth but n exc 3.0m depth, complete all as specified and as directed.
Demolition and breaking of drain pipe ( salt glazed wire, AC or reinforced concrete) set in cement moter for 150mm dia pipe, complete all as specified and as directed.
S&F of Double Wall Corrugated (DWC) HDPE pipes 150 mm bore SN 8.0, single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore, complete all as specified and as directed.
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforced concrete, complete all as specified and as directed.
M&L for pre-cast RCC 1:2:4 type B-1 as in cover slab for manhole drain set in cement mortar 1:4, complete all as specified and as directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
S&F TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips .
Demolition of brick work or stone/ boulder masonry built in CM including all quoins, arches, pillars etc, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removal of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed, complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks Type C1,1:3:6 (using 20mm graded stone aggregate) built in CM 1:6, exc. 10 cm in width and setting in mortar, complete all as specified and as directed.
M&L for 10mm thick plaster in cm (1:4) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement, complete all as specified and directed
Material and labour for cement concrete 1:4:8, type D2, (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils, complete all as specified and as directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point, complete all as specified and as directed.
M&L for providing PCC (1:2:4) type C1 (using 12.50 mm graded aggregate) as in surface channel and drain, complete all as specified and as directed.
M&L for Hardcore of brocken Stone of gauge n exc 63mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M&L for 100 mm thick PCC 1:3:6 Type C-2 ( using 40 mm graded crushed stone aggregate) as in sub base of floor, complete all as specified and as directed.
M&L for Sand Spreading and levelling under inter locking paver block, complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking rubber moulded paver block with grey cement and colour pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and as directed.
M&L for cement concrete 1:2:4. Type B0, (using 12.50mm graded stone aggregate) as in cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, Copings, etc, including formwork, complete all as specified and as directed.
M&L for 20mm thick cement mortar 1:6 screed bed on concrete floor for laying tiles etc, complete all as specified and as directed.
M&L for chequered cement concrete tiles with grey cement and pigment of size 30cm x30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors, complete all as specified and as directed.
M&L for 75 mm thick cement concrete, 1:3:6, type C1, (using 20 mm graded stone aggregate) as in plinth protection finished fair and even without using extra cement, complete all as specified and as directed.
M&L for RCC septic tank 50 users with up upflow filter type designated to carry sewage and sullage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth 1.5 mtr and over all depth of 3 mtr, complete all specified and shown on drawing No CESZ/2020/STD-02 Sheet 1/2 to 2/2
M&L for Construction of Brick Masonry SOAK WELL OF SIZE 2.25 M DIA & 4.50 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No CESZ/2020/TD/45 Sheet 1/2 to 2/2
Cutting of bituminous road of any thickness/depth, complete all as specified and as directed.
Schedule of Credit
M/S SUBHASH BHATTACHARJEE
M/s UB Enterprise
M/S C.M.V CONSTRUCTIONS
M/s Jaiswal and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .