Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.5 Cr+₹17.6 L (7.66%)Rejected-AOC COLABA MUMBAI | ₹2.5 Cr+₹17.6 L (7.66%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹2.5 Cr+₹24.8 L (10.8%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹2.5 Cr+₹24.8 L (10.8%) | L3 | Rejected-AOC Rejected |
| 4 | Rejected-Technical NOT AVAILABLE | - | - | Rejected-Technical Rejected due to not enlisted in b (ii) category |
Tender Value
₹2.8 Cr
EMD Value
₹3.5 L
Closing Date
25 Jan 2020, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF INDEPENDENT 24 INCH DIA WATER SUPPLY PIPELINE FROM MANTRALAYA TO NAVY NAGAR AND ASSOCIATED WORK DEPOSIT WORK AT COLABA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2019_MES_293181_1
8165/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW NAVY NAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE NW NAVY NAGAR
₹3.5 L
Yes
27 Feb 2020
26 Oct 2019
28 Jan 2020
28 Oct 2019
25 Jan 2020
26 Dec 2019
28 Oct 2019 - 4 Nov 2019
Amount
Surface excavation in hard dense soil, not exceeding 30 cm deep and averaging 15cm deep and getting out soft / loose soil
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out in soft / loose soil
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in hard / dense soil
Material & labour for anti termite treatement by Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
Material & labour for anti termite treatement of Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed
Material & labour for anti termite treatement of Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed
Material & labour for anti termite treatement of Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Material & labour for anti termite treatement Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Material & labour for PCC 1:4:8 type D2 ( 40 mm graded aggregates) in foundations, filling and mass-concrete etc complete all as specified and directed.
Material & labour for PCC 1:3:6 type C2 (40 mm graded aggregates) Cement concrete in foundations, filling and mass-concrete etc complete all as specified and directed.
Material & labour for PCC 1:3:6 type C2 (40 mm graded aggregates) Cement concrete in surface channel and drain complete all as specified and directed.
Material & labour for reinforced cement concrete M-20 (using 20 mm graded stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
Material & labour for reinforced cement conrete M-20 (using 20 mm graded stone aggregate) as in columns pillars, posts and struts etc complete all as specified and as directed
Material & labour for reinforced cement conrete M-20 (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5 m span
Material & labour for reinforced cement conrete M-20 (using 20 mm graded stone aggregate) slabs supported on walls, in floors, roofs, landings, balconies, canopies, deck slabs and the like
Material & labour for reinforced cement conrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in chajjas complete all as specified and as directed
Material & labour for reinforced cement conrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping to manholes including weathering, slightly rounded or chamfered angles and throating as directed all as specified.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces
Use and waste of formwork to the sides of pillars, posts, struts, piers, columns
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use and waste of formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Use and waste of formwork to the sides and edges of roof slab not exceeding 20 cm thick
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges
Material & labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT bars
All as per item No 24 herein before but 5 mm dia and over upto 10 mm dia in stirrups spacers and binders
Material & labour for pre-cast cement concrete block masonry with solid blocks (PCC 1:3:6 type C-1 using 20 mm graded stone aggregate) exceeding 10 cm in width and setting in cement mortar (1:6) complete all as specified and as directed
Material & labour for Damp proof course 25mm thick to horizontal or vertical surfaces including necessary formwork In cement concrete 1:2:4, type B-0 (using 12.5 mm aggregate)
Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per Sqm
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm.in any type of soil all as specified and directed.
Removing excavated material outside MD land exceeding 1.50 km but not exceeding. 15 km and depositing where directed.
Material & labour for Rendering 15mm thick plaster in cement mortar (1:6) on brick or concrete masonry walls, finished even and fair without using extra cement complete all as specified and directed.
Material & labour for Plastering on concrete surfaces of ceiling, beams, lintels, walls etc, 20mm thick (15+5mm)in two coats in CM (1:4) , mixed with water proofing compound on fair faces of brick work or concrete surfaces, finished fair & even without using extra cement complete all as specified (WPC to be mixed in setting coat only and shall be measured and paid separately)
Supply only water proofing compound ISI marked Dr Fixit / Scott
Material & labour for plastering 5mm thick plaster in cement mortar 1:4 on concrete surfaces of ceiling , finished even and fair without using extra cement complete all as specified and directed.
Material & labour for preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of wall putty
Material & labour for preparation of new undecorated surfaces of walls, soffit and applying two coats of weather proof Acrylic based paint(100% Acrylic) exterior grade over a coat of primer complete all as per manufacturers instructions all as specified & directed by Engineer-in-Charge.
Material & labour for preparing newly plastered surfaced of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed
Material & labour for broken stone & boulders hardcore of gauge not exceeding. 63 mm, deposited, spread and levelled in layers not exceeding. 15 cm thick, watered and rammed to a true surface
Material & labour for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20 mm graded aggregates) as in sub base flooring finished even and smooth without using extra cement all as specified and directed.
Material & labour for 100 mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded aggregates) as in floors & pavings finished even and smooth without using extra cement all as specified and directed.
Supply & fix 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
Supply & fix 30 MM thk Flush shutters, solid core construction, with particle board core both face is covered with decorative face veneer with lipping/frame to match
Material & labour for MS works in holdfast made of fe -290 of length
Supply & fix Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed of length 300 mm
Supply & fix Aluminium handles, cast type, anodised of length 150 mm
Supply & fix in SS butt hinges 100 mm size
Material & labour for preparing wood or wood based material over 10 c m width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
Supply & fix Aluminium anodised section (minium thickness of anodising 15 micron) for window / ventilator etc of sliding type comprising frame, shutters, locking arrangements including necessary jamming, glazing pins, neoprene beading, glazing pin screw, rollers, handle etc complete all as specified & directed by Engineer-in-Charge. Note: (a) Glazing shall be measured separately. (b) Item shall be paid as per weight of aluminium section. (c) Rate quoted shall be inclusive of neoprene beading, glazing clips, screw etc as required which not be measured for arriving the weight. (d) Rate shall be inclusive of star locking arrangement including complete packing with silicon gel around contacting surface of aluminium and including matching the existing surface area complete all as specified. (e) Aluminium window / ventilator etc to be fixed with cadmium plated screw not more than 300mm c/c .
Material & labour for 5.5 mm thk Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane
Supply & fix Steel rolling shutters manual type, 1.25mm thick laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop at of primer; erected in position as indicated, complete: push pull or manual type
Material & labour for for preparation of new steel surface of any descriptionot exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of Red oxide primer
Supply & fix MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
Material & labour for DI specials conforming to IS - 9523 (2000), spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 300 mm bore pipes (joints and joining material shall be measured and paid seperately)
Material & labour Concrete bed to drain pipes including packing against the sides of pipes with concrete after they are laid and tested for 150mm dia pipe with cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate ) all as specified.
Material & labour Salt glazed stone ware drain pipes 150 mm dia conforming to IS grade 'A' laid in trenches and jointed as specified.
Material & labour brick work with subclass B brick straight or curved on plan exc. 6m mean radius , built in cement mortar 1:4 all as specified .
Cutting into existing manholes for connecting new drains making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 , smooth finished , and reforming benching for 200 mm dia.
Supply & fix cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles
Material & labour rendering 10mm thick on brick or concrete surface in CM 1:4 finishing surface even and smooth without using extra cement.
Supply & fix structural steel work of angle channel etc confirming to gde FE 410-W fixed independenly as in fencing brackerts etc
Excavation post holes or similar holes, each not exceeding 0.5 cum getting out in hard / dense soil, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50m and making good surface
Supply and fix galvanised 2 strand steel barbed wire 2.24mm dia barded with 2mm dia bards at 75mm spacings and straining and fixing to any type of standared rails straining bolts, including securing or tying or crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured)
Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Protection and communication Panel for panel for pump and valve automation suitable for control and/or monitoring of 02 Nos. Centrifugal pumps, 2 Nos. motorized valves, 02 Nos. priming valves, 02 Nos. air release solenoid valves, 01 Nos Ultrasonic level sensor, 01 Nos Pressure transmitters and 02 nos. level switches.The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated with angle iron supports not less than 40x40x5mm. .The Panel should comprise the following items: (a) Water Level Sensing & Display (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention (h) Manual Mode Operation (all connected sub systems including all valves (in pump houses and connected buildings / overhead tanks) and pumps from the PLC based Control Panel. Make :- Ritetork / Siemens / Honey Well
Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 300 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Input Voltage: 230 V, A.C Designed linepressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memory In built SD Card Space Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data.Mounting :Direct on valve. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply and fix ball type foot valve 10/15Kg/Sqcm (ISI marked) in position at location including Material & labour for making flanged joints of 300 mm size as directed by Engineer In Charge. Make :- Normex (Model B-5) / Kirloskar / Zoloto
Supply and fix swing type Non Return Valve of dia 300 mm Confing PN 10 with rubber slap confirming IS 1538 ,Table 4 & 6.Make:- Normax, Kirloskar, Zoloto
Construction of brick masonry valve chamber of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embedded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces excavation and earth work returning filling and removal in any type of soil complete all as specified.
Supply and lay spigot and socket ends, Ductile iron pipe K-9 conforming IS 8329 : 2000 in any length laid in trenches of 300 mm bore, 7.2mm nominal wall thickness sizes all as directed by Engineer-in-Charge. Make :- Electro steel castings Ltd / Jindal saw ltd / TATA mataliks / Electrotherm (India) Ltd.
Supply, install, test and commission centrifugal pump set of capacity 150 LPS at 37 mtr head two Stage single suction horizontal axially split volute type, suction and discharge nozzles and supporting feet cast integral with lower half casing complete with squirrel cage induction motor for operation on AC 415 Volts 50/60 Hz,Upto 150 HP with suitable RPM to drive the pump set, Complete all as per the OEM Specification /specified and directed (quated Rate include foundation and vibration pad) Make: Kirlosker Brothers Ltd / KSB / Crompton Grevees / Wilo / Best & Crompton
Supply ,install, test and commissioning LT Panel board from CPRI approved panel manufacture made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin weather and proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc provn of cable entries at bottom with cable glands including the following :- (a) MCCB 4 pole, 415V,630Amps 50 KA - 01 No (incoming)Microprocessor base release,ICS=ICU=100% Make :L&T/ABB/Siemens/legrand (b) MCCB 3 pole,415V,250mps 35 KA - 02 Nos (outgoing) adjustable thermal adjustable magnetic release,ICS=ICU=100% Make L&T/ABB/Siemens/legrand (c) Automatic star/Delta starters panel mounting suitable for 150 HP-02 Nos.Make :L&T/ABB (d) Phase indicating lamps(RYB)-03 set (e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-03 set. Make: Dip/AE/IMP (f) CTs 60/5 Amps for meters - 03 Nos.
Supply and fix PVC water storage tank (ISI marked) of capacity 5000 Ltr three layer including fixing and foundation at desire location all as per directed by Engineer-in-Charge
Supply and fix gunmetal gate vale of 50mm dia complete all as specified and directed.
Supply & Fixing of steel water tubing 50mm bore galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary fittings complete all as specified and directed.
Supply & fixing of steel water tubing 25mm bore, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary fittings complete all as specified and directed .
Supply and lay MS pipes 300mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings etc complete all as specified and directed.
Supply and lay MS pipes 250mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings etc complete all as specified and directed.
Supply & fixing on wall/ laying in trench 5 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, Copper cable. (Make: POLYCAB/FINOLEX/RR CABLE)
Supply, Installation Testing & Commissioning of pressure Transmitter with following specification including necessary power pack for supply of DC : Power supply: 10-36 V DC Process connection: G ½ “ Enclosure: whether proof IP 65 Process temperature: -30 to 120 celcius Accuracy: 0.25 % Make: Danfoss / Siemens / E & H
Supply, Installation Testing & Commissioning of motor actuated ball valve suitable for 25 mm GI pipe for priming of pump including all necessary GI fittings with following specifications: Size: 25 mm Pressure rating: 10 kg / sq. cm. Make: AVCON/ ROTEX/ ASCO/JOHNSON CONTROL/ RITETORK
Supply, Installation Testing & Commissioning of direct acting type release solenoid valve for air release during priming; with follwing specifications : Size: 10 mm Pressure rating: 10 kg / sq. cm. Type: Normally closed. Make: AVCON/ ROTEX/ ASCO/JOHNSON CONTROL/ RITETORK
Supply & fix sluice valves 300mm size flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class P N 1.6, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed
Supply and lay PVC insulated, armoured, heavy duty electric cable with copper conductor, 1100 volts grade, 3 core, cross sectional area 95 Sqm. Make :- Polycab / Havells
Supply, install, testing and commissioning of Vaccum circuit breaker panel board 11 KV, 630 Amps, 25 KA, 3 Phase, 50 Hz, AC Supply system, indoor type metal and clad totally enclosed free standing floor mounted type suitable for housing trolly mounted vaccum circuit breaker, horizontal isolation and horizontal draw out type,cubicle should be IP 65 class degree of protection 600 Amps rated copper busbar complete and comprising of the following and all as specified. Make: Siemens/ABB/Schneider Note :- (i) Cost for suitable cost of suitable base platform / founder as per excising is included in the rate quoted. (ii) Cost of extensible bus coupler to fix VCB with existing VCB shall be carried out in the quoted rate. (iii) Setting of relays to match the existing HRT network shall be done by the contractor
(A) PANEL should be comprising trolly mounted horizontally isolated, horizontally draw out type VCB 11 KV,630 Amps capacity, 25 KA completely enclosed with provision of mechanical locking and having 3 Nos vaccum interrupters of ratings 11 KV, 630 Amps, 25 KA capacity mounted on common phase segregated epoxy body for higher elect insulation and to maintain pole discrepancy as per IEC 56 and self alligned type isolating contacts, manual and motor operating (230 volt AC spring charged mechanism, manual closing and tripping push buttons, emergency trip push button, mechanical indication for circuit breaker close/open, mechanical operation counter, 08 No +08 NC breaker operating auxillary switch, spring charged/discharged indication, circuit breaker service/test position indication etc and with the following accessories :- (i) Floor mounted panel fabricated with 3 mm thick CRCA sheet duly powder coated with self contained air insulated compartments for bus bars and cable boxes with necessary supports. (ii) Fixed spout insulators with effectively covered by safety shutters automatically open/close while draw in/draw out operations. (iii) 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system in closed position for earthing/maintenance purpose. (iv) An epoxy interupter per phase all as per manufacturers design.
(m) Strip type heater 80 watt, with thermostat control and switch for breaker compartment and CT compartment - 01 set (n) Mecch (caster lock) and elect inter locking sys- 01 set (B) BATTERY BANK WITH CHARGER FOR AUXILLARY SUPPLY - 01 SET Battery bank 24 volt consisting of 02 Nos 100 AH, 12 volts cells, maint free lead acid alongwith Racks & connections with suitable rating copper bus bar covered with PVC sheet and suitabale rating of float cum boost battery charger of rating 230 volt AC i/p, protection for i/p & o/p. 2 core, 10 Sqmm, copper conductor un-armured cable (25 RM Approx) with crocodile clamps/lugs on ends from LT Panel to charger for 230 volts AC Supply and battery charger to VCB panel. Make : Exide/Amararaja/HBLNIFE (C) ALARM SYSTEM :- Common alarm with reset sys to be provided on panel bd for ckt breakers trip, DC auxilary supply failure and AC auxilary supply failure. (D) 230 VOLT AC AUXILLARY SUPPLY:- 2 Core,10 Sqmm,copper conductor, un-armoured cable from LT panel/DB to VCB panel bd 25 RM (Approx) (E) RUBBER MATTING:- (a) Rubber matting nibbed pattern suitable for 11 KV grade as per IS of size 2 m x 1m x 20mm thick - 01 Nos (F) Supply and fixing/Connecting indoor type 11 KV Single phase Resin cast dry type PT of ratio 11KV/rt3/110V/rt3 class 0.5-3, Burden 100VA insulation level 28KV/75KV voltage factor 1.2 Cont and 1.9 for 30 sec, confirming to IS-3156 - 3 Nos
Supply installation testing and commissioning of transformer step down, indoor type, with all standard fittings, 11000Volts/433 Volts, AC, 3 phase, 4 wire, 50 Hz, Copper wound, oil immersed naturally air cooled with external cooling tubes, with off load tap changer on HT side to vary secondary voltage +5 % to -10% in steps of +/- 2.5 % as per IS : 2026 of capacity 400 KVA and oil shall conform to IS 335 of 1983 including first filling of oil complete including LV and HV side cable termination end box, uni-directional roller, conservator, silica gel breather, drain and filter valves and LV cable gland all as directed. Make of manufacture :- ITL / Pactil / Voltamp / Crompton Greaves / Bharat Bijili
(a) Winding Material : Copper (b) Type of Cooling : ONAN (c) Class of Insulation : Class “A” (d) Primary Connection [HV] : Delta (e) Primary Volts : 11000 (OR) 433V (f) Primary Wires : 3 (g) Primary rated current : 26.24 A (h) Secondary Connection [LV] : Star (j) Secondary Volts : 433V (k) Secondary Wires : 4 (l) Secondary rated current : 666.71 A (m) Rating & Terminal Marking Plate -01 (n) Earthing Terminals -02 (o) Lifting Lugs -04 (p) Drain Valve with blanking plate -01 (q) Filter Valve with blanking plate-01 (r) Conservator -01 (s) Conservator Oil filling hole with cap -01 (t) Oil Level indicator with min. marking-01 (u) Dehydrating Breather-01 (v) Conservator Drain Plug -01 (w) Air Release Device -01 (x) Thermometer Pocket -01 (y) Pressure relief valve -01
(z) Roller Bi directional -04 (aa) Radiators (Weldable) -04 (ab) Cable Box HV -01 (ac) Cable Box LV -01 (ad) Separate Neutral Terminal -01 (ae) Off Circuit Tap Changer -01 (af) O.T.I with Alarm & Trip Contacts -01 (ag) Buchholz relay with Alarm & Trip Contacts -01 (ah) Marshalling Box -01 (aj) W.T.I with Alarm & Trip Contacts -01 (ak) W.T.I. Pocket One 25 Current Transformer -01 (al) Transformer oil to be filled up to the normal level as specified by the engineer in charge Note :- Routine tests such as Ratio test, Polarity, Phase angle error measurement, Vector group test, B D V of oil, I R Values, Winding resistance, Open circuit test, Short circuit & Impedance test, Separate source voltage test, Induced over voltage test etc shall be carried out at factory before despatch in presence of Rep detailed by accepting officer. necessary arrangements shall be done by the contractor and shall quote his rates accordingly.
Supply and laying in trenches/through pipes or bare in road crossings/ paths/drains/ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11KV grade, of cross sectional area 185 Sqmm, 3 core laid all as specified and directed.
Material & labour for Cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm.
Supply & fix cable route indicator made of 15cm x 15cm x 6mm thick MS plate welded with 10mm x 30cm long MS rod grouted in PCC block of size 0.2 x 0.2 x 0.3 m and writing HT cable complete all as directed.
Supply and Laying High density polyethylene pipes (HDPE) of pressure rating 10 kgf/cm2 laid in trenches of size 150 mm bore for the protection of UG cable.
Supply, install, testing and commissioning of LT distribution panel, CPRI type tested, weather/vermin proof, made out of 2 mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, indoor type, with front and backside doors with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 800 amps current carrying capacity Copper bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage complete and comprising of following switch gears and mounting the panel board on floor complete all as directed :-
Supply, install, testing and commissioning of LT, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR with incoming MCCBs, CPRI type tested, weather/vermin proof, made out of 2 mm thick CRCA sheet, factory assembled modular and non compartmentalized construction, indoor type, with front side hinged door with locking arrangement, floor mounted free standing type, duly powder coated, with Al Bus Bars and Multistrand copper cables of appropriate size for each feeder comprising of following all as dirceted:- (i) MCCB, Thermal Magnetic type, 400 Amp, 4 Pole, 36 KA - 1 No. (ii) MD-XL capacitor 440V, 2 kVAR with 10kA MCB & Capacitor dutyswitching contactor - 1 No. (iii) MD-XL capacitor 440V, 3 kVAR with 10kA MCB & Capacitor dutyswitching contactor - 1 No. (iv) MD-XL capacitor 440V, 5 kVAR with 10kA MCB & Capacitor dutyswitching contactor - 2 Nos. (v) MD-XL capacitor 440V, 10 KVAR with 10kA MCB & Capacitor dutyswitching contactor - 1 No. (vi) MD-XL capacitor 440V, 25 kVAR with 10kA MCB & Capacitor dutyswitching contactor - 1 No. (vii) MD-XL capacitor 440V, 50 kVAR with 10kA MCB & Capacitor dutyswitching contactor - 2 Nos. (viii) Microprocessor based intelligent power factor 8-Step relay with RS485 Port type RVT of ABB Make equivelent in Siemens/ Schneider (ix) CONTROL COMPONENTS: (a) CTR: 200/5A CL: 1, 5VA -3 Nos. (b) Digital Multi meter to measure Volt, amps and PF - 1No. (c) Indication Lamps for RYB (LED Type) - 3Nos. (d) Out going Indication Lamps (LED Type) - ON/OFF - 8 Nos. (e) Exhaust Fan -1 No.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 metre below normal ground level, connecting to GI strip of size 32 mm x 6 mm from earth plate to body of the equipment Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate ( 6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area 400 Sq MM 3.5 Core
Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area 10 Sq MM 4 Core
15.Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm.
Material & labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm thick, ISI mark with all accessories on wall/celling/floor/roof etc,suitable size of PVC board ISI marked for fixing of switches and sockets complete ISI marked with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- Make of cable: Finolex/L&T/Havells/Anchor. Make for PVC conduit : Poly plast/pressfit /Presto-plast/ Precision.
(a) One light/ fan/ E'fan point controlled by one switch
(b) One 3 pin socket outlet, 5 Amps on the same board with other switches.
(c) One 3 pin socket outlet, 5 Amps, independent
Material & labour for point wiring complete with proper colour coding using, 1100 volts grade, 2.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC conduit not less than 25 mm thick, ISI mark with all accessories, fixing on wall/celling/floor/roof etc,suitable size of PVC board ISI marked for fixing of switches and sockets complete ISI marked with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for 15 Amp power point.
Supply & fix switch piano, flush type, single pole, one way 5 Amps, 240 Volts. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fix switch socket combination 2 in 1, 5A flush type, ISI marked, 240 Volts, all as specified. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fix switch socket combination, ISI marked flush type, multipurpose 3 pin, 15 Amps and one pin 5 Amps controlled by one switch all as specified. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fix stepped type (5 step) electronic fan regulator 230 volts ISI marked and connecting up complete. Make: Anchor model No 1452 Delux fan regulator rotary type or equivalent in Crabtree/ Bajaj/ CG.
Supply & fix ceiling rose surface bakelite 65x50 mm with 3 terminals. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fix LED tube light fitting 4 feet long with high efficent LEDs with clear diffuser of capacity 20 watt including connection with connecting accessories and fixed on its original position all as specified and directed. Make-C & S/ Philips/Wipro/ Havells/ Bajaj.
Material & labour for sheet metal enclosure for DBs when MCB 'C' characterstic, 10 KA to be used single phase 4 way, double door,240V having Din rail, Neutral & Earthing bar as per IS-8828 of 1996 DB sheet not less than 1.2mm with powder paint, min ingress protection shall be IP20, label indicators shall be provided over all incoming/outgoing circuit complete all as specified and directed.Make - LEGRAND Cat part No: 607711 or its equivalent in Siemens/ Hagar/ Schneider.
Supply & fix MCB SPN, up to 32 Amp, 10 KA, 230 Volt.Make - LEGRAND Cat part No: 603254 or its equivalent in Siemens/ Hagar/ Schneider.
Supply & fix MCB, single pole, upto 16 Amp, 10 KA, 230 Volt.Make - LEGRAND Cat part No: 603231/33/34 or its equivalent in Siemens/ Hagar/ Schneider.
Supply & fix cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 Sqmm stranded copper conductor electric cable on wall/ roof/ duct complete and connecting to DBs with glands including taking out existing damaged cables and all as directed. Make-Polycab/plaza/Finolex.
Supply & fix ceiling fan 1200 mm sweep, 230 V, 50 Hz, minimum 5 star rating and energy saving, hanging on ceiling and connect with copper conductor multi stranded 3 core wire of size 14/0.0076 including taking out old US one. Make - Havells model No. ES 40 or equivalent to Khaitan/ CG/ Havells.
Supply & fix Exhaust fan 300mm sweep, 230 V, 50 Hz, having power input 70 W, speed 1440 RPM, with protective bird guard including connection as required at site with flexible copper cable complete all as specified and as directed by Engr-in-Charge and as per Hevells model-VENTIL AIR DB or equivalent in Khaitan/USHA/Almonard.
Material & labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth GI wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 20 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engineer-in-Charge including testing on completion.
Supply, install, commissioning & testing of diesel engine driven Generating set complete with accoustic enclosure and control system for 320 KW/400 KVA output at site, AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled complete with self starting system including foundation as per OEM specification, accessories, equipment control panel etc as per BS/IS-5514/10002. (Note : AMF Panel will be measured and paid separately) Makes :- Kirloskar Oil Engines Ltd / Greaves Cotton / Cummins India Ltd / Mahindra / Ashok Leyland / Crompton Greaves
(a) Diesel engine :- Diesel engine turbo charged water/Coolent cooled and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, eight cylinder, four storke, cold starting, 1500 RPM @ not less than 490 BHP industrial type as per BS-5514 or IS-3046 with electronic governor for G3 governing class suitable to regulate speed of DG set from No load to full load complete with fuel tank of cap as per manufactrer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc, auto start of DG Set on mains failure all as specified and directed. (b) Fuel Tank:- In built removable type sheet metal fuel tank of capacity not less than 850 Ltrs complete with fuel gauge, drain plug and fuel connection.
(e) Battery :- Exide or Tata make 150Ah, 2 x 12 Volt fully charged battery of suitable capacity as recommended by OEM of DG set . (F) Acoustic Enclosare :- Acoustic Enclosare silent canopy conforms to the latest CPCB-II emission norms. Average sound emission from the canopy at a distance of 1 meter in green field condition is less then 75 dB . (g) AMF Panel, factory made, fabricated out of CRCA sheet 2 mm thick, over an angle iron base frame made out of suitable angle iron, hinged front panel door, duly powder coated, indoor type, floor mounted, totally enclosed, free standing type, 3 phase and neutral 800 amps current carrying capacity copper bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting bus bar connection/linkage complete suitable for 400 KVA capacity DG set with bypass arrangement, with micro proccessor based controller AMF relays to control/monitor volt, amps, frequency, energy & all engine parameters with protection fuses for panel instruments, battery charging system with indicator and cut off relays, Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over kW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm, Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency, reverse current protection, duly wired with flexible copper conductor cable and cable connection with lugs / thimble complete with necessary control cabling from acoustic enclosure and to the AMF panel for all the operation and safety parameters of the DG set as recommended by manufacturer and mounting the panel board on floor, complete all as directed by Engineer-in-Charge including the following control gears :-
(i) Contactor of capacity 630 A, 4 Pole - 2 Nos (Make : L&T/Schnider/Siemens) with add on block and Mechanical interlock. (ii) MCCB, 4 Pole, AC, 415 Volt, 50 Hz, Breaking capacity 50 KA, with electronic release, 630 A capacity - 2 Nos with auxiliary contacts, to indicate tripping of respective MCB (Make ABB/Schneider/Legrand) (iii)Suitable No.of LED type indicating lamps 220 volts of make ABB/Schneider/Legrand (iv) Suitable No.of ON/OFF/Reset push buttons with element of make ABB/Schneider/Legrand (v) Suitable Number of Control MCB SP 6 amps C curve 10KA of make ABB/Schneider/ Telemecanique (vi) Suitable number of Control relays 12 volt DC of make ABB/L&T (vii) Battery charger with trickle/boost and rectifier of suitable make: - 01 nos. (viii) PVC insulated armoured copper conductor cable of size 4 Sqmm, 4 core, 1100 volt garde from AMF Panel to DG Set.
Supply & fix on walls and connecting in repair 4 core 1.5 Sqmm armoured cable with copper conductor
Supply, laying in trenches and connecting in repair 6 core 1.5 Sqmm armoured cable with copper conductor
Material and labour for rubber gasket joint of DI pipe 300mm dia complete all as specified and directed
Veer High Tech Solution
AGRAWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .