| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Finance | -24.96% | ₹5.2 L | L1 | Admitted-Finance |
| 2 | L2₹5.9 LAdmitted-Finance | -15.10% | ₹5.9 L | L2 | Admitted-Finance |
Tender Value
₹6.9 L
EMD Value
₹13,882
Closing Date
29 Jun 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Comprehensive and routine maintenance of AC
2026_PWD_294155_1
32/EE (E)/PWD EMD South West/2026-27
Open Tender
Electrical Works
150 days
works
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹13,882
1 Jul 2026
23 Jun 2026
29 Jun 2026
23 Jun 2026
29 Jun 2026
23 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive & Routine maintenance of 135 Nos. WTAC / STAC / Tower AC (as per Inventory attached) i/c attending day to day complaints from 9 AM to 5 PM by deputing minimum following staff (to report to JE(E) daily) and rectify the defects i/c replacement of wornout parts such as starting / running capacitors, starting relays, overload relay, tharmostat, selector switches, sleeves, knobes, connector and associated control wiring, filter, drain pipe, man leads etc which required to be replace during routine maintenance and monthly cleaning of filters etc. (Replacement of compressor, condensor unit, cooling coil unit, blower, fan blower motor, front grill, gas charging etc not covered under routine maintenance) complete as per terms & conditons and Engineer-in-Charge.
(a) AC Mechanic - 1 No.
(b) Khallasi - 1 No | 5 | Month | 60,885 | ₹3,04,425 |
| 2 | Servicing of existing installed WTAC / STAC / Tower AC of 1.5 TR & 2.0 TR capacity AC i/c checking for unit, inspection, greasing, oiling etc i/c chemical cleaning of the condensing coil with high pressure pump changing the air filter, checking & tightening all electic connection, testing the machine etc as reqd. | 135 | Each | 772 | ₹1,04,220 |
| 3 | Dismantling & Re-installation of exisiting installed STAC / WTAC of 1.5 TR & 2.0 TR capacity with outdoor unit from its location to another location, unloading for reinstallation checking for unit, inspection and reconnection of drainage pipe, reconnection and tightening the loose connection, testing the machine etc as reqd. | 8 | Each | 1,116 | ₹8,928 |
| 4Supply of following capacity compressor in the existing WTAC / Split AC making copper pipe connection, brazong pressure testing and supplying and charging M-22 refrigerant gas charging i/c cutting the copper piping dismantling etc complete as reqd. | |||||
| 4.01 | Compressor - 1.5 TR | 5 | Each | 5,394 | ₹26,970 |
| 4.02 | Compressor - 2 TR | 6 | Each | 6,214 | ₹37,284 |
| 5 | Supply of WTAC /STAC fan motor capcity 1/4 to 1/8 HP i/c fixing of new motor making connection, testing complete etc as reqd | 8 | Each | 2,312 | ₹18,496 |
| 6 | Supplying & charging of M-22 / R-22 /R-32 gas in the exising WTAC / STAC of 1.5TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd. | 20 | Each | 2,504 | ₹50,080 |
| 7 | Supplying & charging of M-22 / R-22/R-32 gas in the exising WTAC / STAC of 2 TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd. | 25 | Each | 2,778 | ₹69,450 |
| 8 | Repair of damaged PCB of indoor and outdoor unit i/c tightening the loose connection, testing the machine etc as reqd. | 12 | Each | 1,076 | ₹12,912 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.67 MB
BOQ_391067.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid