| 3 | L3₹15.1 CrRejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹15.1 Cr | L3 | Rejected-Finance Being Not Lowest |
| 4 | L4₹15.2 CrRejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 UDYAM GJ 05 0006749 24AACFK2418A1Z4 B R MSME STATUS AS VERIFIED | BHAVNAGAR | GUJARAT | 364001 | ₹15.2 Cr | L4 | Rejected-Finance Being Not Lowest |
| 5 | L5₹16.6 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹16.6 Cr | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.3 Cr
EMD Value
₹7.9 L
Closing Date
18 Sept 2020, 6:00 pmClosed
CE (AF) Gandhinagar
Lekawada Patia, Chiloda, Gandhinagar 382042
COMPLETION OF INCOMPLETE WORK FOR CONSTRUCTION OF DEFICIENT MARRIED ACCN FOR NCSE AND DSC PERSONNEL AT AF STATION MUMBAI
2019_MES_281287_2
84159
Open Tender
Civil Works
480 days
GE (AF) Thane
As per NIT and Tender Document
8 documents required · 8 mandatory
₹3,000
GE (AF) Thane
₹7.9 L
Yes
2 Mar 2021
22 Jul 2020
19 Sept 2020
22 Jul 2020
18 Sept 2020
25 Aug 2020
25 Jul 2020 - 29 Jul 2020
Amount
NOTE: Schedule ‘A’ Part I to XII are under Ser No. 2.00 to 13.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Internal Water Supply as listed inSch `A’ Part II
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part III.
Lump sum price worked out for Site Clearance & Excavation, Earth Work & as listed in Sch `A’ Part IV
Lump sum price worked out for Road, Hard standing & Culvert as listed in Sch `A’ Part V.
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI.
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII.
Lump sum price worked out for External Electrification as listed in Sch `A’ Part VIII
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part IX
Lump sum price worked out for Fire Fighting as listed in Sch `A’ Part X
Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part XI
Lump sum price worked out for Lift as listed in Sch `A’ Part XII
SCHEDULE `A' PART - XIII [ MISC items(to be quoted by tenderers)] Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
EXTERNAL ELECTRIFICATION
Supply install, test and commissioning LT Feeder distribution Panel (CPRI Approved) cubical type Indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plateof thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry
of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated ( for rust proof) sprayed of approved thickness coated complete as specified and consisting the following : -
(i) Busbar Copper TPN 800 Amps -1 Set. (ii) Incoming ACB 4 Pole 630 Amps 415 Volts, Microcessor Based, Draw Out Type -01 No. Outgoing (iii) MCCB FP 160 A 415 Volts 50 kA (with Ajustable Thermal & Magenetic Setting) - 02 Nos (Bldg). (iv) MCCB FP 200 A 415 Volts 50 KA (with Ajustable Thermal & Magenetic Setting) - 1 Nos (AMF). (v) MCCB FP 200 A 415 Volts 50 KA (with Ajustable Thermal & Magenetic Setting) - 1 Nos (APFC). (vi) MCCB FP 125 A 415 Volts 25 kA (with Ajustable Thermal & Magenetic Setting) - 01 Nos (fire Pump). (vii) MCCB TP 25 Amps 16 KA - 2 Nos (Street Light). (viii) MCB SPN 25 A 30 KA-4 Nos. (ix) VAPF Meter -01 No. (x) Indicating Lamps LED Type-03 Nos. (xi) Spare compartments for fixing of MCCB of Range 160 Amps 35 KA - 1 No
All as per item No 15 here-in-before but with the following incoming and outgoing feeders.
(i) Busbar Copper TPN 400 Amps -01No (ii) Incoming MCCB 4 Pole 200 Amps 415 Volts 50 KA (with Ajustable Thermal & Magenetic Setting) -01 No. (iii) Outgoing MCB SP 32 Amps, 10 KA - 45 Nos (iv) MCCB FP 40 A, 25 KA - 1 No. (v) VAF PF Meter -01 No. (vi) Indicating Lamps LED Type- 03 Nos. (vii) One No spare compartments for fixing of MCCB of range 63 Amps 25 KA.
All as per item No 15 here-in-before but with the following incoming and outgoing feeders.
(i) Busbar Copper TPN 400 Amps -01No (ii) Incoming MCCB 4, Pole 160 Amps, 415 Volts, 36 KA (with Ajustable Thermal & Magenetic Setting) -01 No. (iii) Outgoing MCB SP 6-32 Amps, 10 KA. - 48 Nos (iv) MCCB FP 40 A, 25 KA - 1 No. (v) VAF PF Meter -01 No. (vi) Indicating Lamps LED Type- 03 Nos. (vii) One No spare compartments.
All as per item No 15 here-in-before but with the following incoming and outgoing feeders.
(i) Busbar Copper TPN 250 Amps -1No (ii) Incoming MCCB 4 Pole 125 Amps 415 Volts 50 KA (with Ajustable Thermal & Magenetic Setting) -01 No (iii) Outgoing (a) MCCB 3 Pole 40 Amps 415 Volts 36 kA - 03 Nos (Passanger, Goods & Spare). (b) MCCB 3 Pole 25 Amps 415 Volts 25 kA - 01 No. (c) MCB SPN 16 A 230 Volts AC-06 Nos (iv) VAF PF Meter conforming to EM 6459 of Conzerv -01 No. (v) Indicating Lamps LED Type-03 Nos. (vi) One No spare compartments.
Supply and fix post top latern CFL type including all accessories and prewired suitable for and including S Type CFL 1 x 18 Watt CFL complete including clamps , Lamps, GI pipe bracket, nuts bolts washers etc necc for installation of the fitting all as directed by EIC at siteconforming to Cat No CFPT 18 of CG or equivalent from Philips, bajaj complete including clamps , GI pipe bracket, nuts bolts washers etc necc for installation of the fitting all as specified and as directed by Engr-in-Charge. .
Supply and fix street light fitting T5 Lamp type, 4x24 watts with accessories and prewired and incl Lamp conforming to IP 65 degree of protection and incluing GI steel tubing medium grade 40mm dia bent to shape of offset angle upto 45 degree for fixing of security /street light fittings including necessary MS clamps , nuts , bolts, etc all as directed by Engineer in charge. The Fitting shall conform to Cat no T5SHO424EB of CG or equivalent of Philips / Bajaj
Supply and fix FRP looping box prewired complete fitted with TPN bakelite connector block 8 Way of 20 Amps Rating with shorting strip copper, fitted with one Nos of MCB SP 6 Amps 240 Volts for termination of incoming of incoming and outgoing cables, Incluing MS clamps for mounting Looping box in Pole etc all as specified and as directed by Engr-in-Charge.
Supply and Fix Pole Mounted Out Door Type Center Openable Double Door Street Light timer Panel Fabricate from 3 mm CRCA Sheet with Powder Coated, and incluing pole mounting MS brackets/clamps with Nuts/Bolts & the following acessories:- (i) MCCB TPN 25 Amps 25 KA, 415 Volts - 1No. (ii) Timer FM 200 - 1 Nos (iii) Contactor Three Pole 415 Volts ML-2 Type - 1 No.
Material & labor for wiring with 3 Runs of 1.5 Sqmm wire in PVC conduit from Looping box mounted in pole to Street light fittings/post top lantern/security light fitting, all as specified and as directed by Engr-in-Charge.
Supply and fix obstruction light incluing die cast aluminium body, red colour polycarbonate dome, GLS lamps 2 Nos and connecting wires, mounting fixtures all Conforming to Cat no BJAOL 2 ES of bajaj or Equivalent From Philips/Crompton all as specified and as directed by Engr-in-Charge.
Supply and fix Glow sign board backlite type of size 4 ft x 2 ft in black or white GI sheet 26 guage, outside black or white powder coated frame of size 75 mm x 75 mm, GI Pipe Supports of size 50mm, fitted with tube lights (make - CG/BAJAJ/Philips) prewired complete with standard accessories, connector block, ballast etc duly written in bold, capital, including necessary armoured cable connection for supply connection of required length, connecting up complete all as directed at site by Engineer-in-Charge. The boards should be duly writtened with COTTON GREEN all as specified and as directed.
All as per item No 25 here-in-before but size of 2 feet x 2 feet and duly writtened Power house, Pump house and Fire fighting Pump house.
Material & labor for cutting into the existing road/hard standing surfaces to a depth of 60cm and 50cm wide and getting out for laying under ground cable including returning filling in, watering, well ramming in layers not exceeding 25cm in any type of soil and filling the top surface 15cm thick with PCC 1 : 2 : 4 type B1 using 20mm graded stone aggregate and finished even and fair without using extra cement including disposal of surplus soil all as directed by Engineer-in-charge.
EXTERNAL WATER SUPPLY
Supply, install, testing of centrifugal pump having Minimum discharge capacity of 12.5 LPS at minimum 60 Meter head 1500 RPM HP directly coupled with suitable induction motor AC 3 Phase, 415 Volts, 50 Cycles TEFC mounted on MS chaneel/Common base plate and fixed with suitable base bolts, grouted in PCC Foundation, 30 Cm above floor level including single core multi stranded PVC insulated copper conductor of 10 Sqmm size connection between starter & Motor Terminal, drawn through PVC conduit all as directed. Make Pump & Motor- Kirloskar/Crompton i) Brass Foot Valve (Make- Kirlosker/Venus) - 1 No Suitabe for Suction of Pump ii) Flanged CI Sluice valve - 1 Nos Suitable of Deliverry of Pump, iii) Flange CI NRV - 1 Nos, Suitable for Delivery of Pump iv) Suction pipes of Dia as Specified by Manufactures to a Length Not More than 9 Meters
(v) Delivery pipes of Dia as Specified by Manufactures to a Length Not More than 6 Meters. (vi) Burden type pressure gauge on delivery of Pump set. (vii) Interconnection of Delivery mains. (viii) 20 mm GI Pipe line fo Priming. (ixi) 20 mm Gun Metal Late Valve (Priming Valve) - 1 No.
Material and labour for Construction of valve pit chamber of follwong sizes with brick massonary, one brick thick wall in cement mortor (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in fdn, 15 mm thick cement & plaster rendering internally all arround over brick wk & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover incld 40 x 40 x 6mm MS angle frame fixed locking arrangement and painting with one coat of red oxide and two coats of black Bituminous paints of size 1200mm x 1200mm x 900mm all as specified and as directed by Engr-in-Charge.
Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 80 mm dia including necessary fittings all as specified and as directed by Engr-in-Charge. Make- Audco/Kirlosker.
Supply install, test and commissioning LT Feeder distribution Panel (CPRI Approved) cubical type outdoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall
be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated ( for rust proof) sprayed of approved thickness coated complete as specified and consisting the following :-
(i) Busbar Copper TPN 200 Amps -1No. (ii) Incoming MCCB 4 Pole 100 Amps 415 Volts 56 KA -01 No. (iii) Outgoing (a) MCCB TP 40 A 415 Volts, 25 KA - 02 Nos. (b) MCCB TP 25 A, 25 KA -1 No. (c) MCB SPN 16 A- 01 No. (iv) VAF PF Meter conforming to EM 6459 of Conzerv -01 No. (v) Indicating Lamps LED Type-03 Nos. (vi )STAR Delta Starter for 15 HP Pump - 02 Nos.
Supply, installation, testing and commissioning of Direct Cyliner Mounted type Vaccum type pressure feed ochlorination Plant having capacity of 1.00 to 1000 gms/hr compete including, gauges all as specified and as directed by Engr-in-Charge with following accessories:-
(a) Chlorinator with Chlorine Monitor & regulator panel complete with accessories Cylinder Mounted type. (b) Chlorine Injector. (c) Chlorine piping connections including fittings. (d) Water Piping Connections 25 mm PVC Flexible pipes incluing globe valves & Fittings. (e) Duly filled in Chlorine Cylinders 10 KG (along with Test Certificates) - 2 Nos (f) Chlorine gas testing kit with test capsule having range 0.1ppm to 3ppm - 01 Nos. (g) Liquid ammonia having specific gravity 0.910 (NH3 about 22 to 25% by wt) in 450ml bottle - 01 No. (h) Ortho Tolidine solution in 500ml bottle - 1 No. (j) Chlorine Cylinder Key - 1 No. (k) First Aid safety Kit - 1 No.
STAND BY POWER SUPPLY
Supply install testing and commissioning of silent diesel Engine driven generating set 100 KVA capacity, 3 phase 4 wire 415 V 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures should have salient features as modular bolted construction with fabrication on imported CNC turret punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application/installation. Integrated design thereby faciliating/easy handling installation & shifting of the eqpt
at site. The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories and installed on PCC foundation (The PCC foundation shall be up to one mtr above floor level) as recommended by manufacturer. Vibration pad sand cushioning around PCC foundation. Tools and spares as provided by manufacturer all as specified and as directed with the following specifications :- (A) ENGINE : Water cooled diesel Engine of suitable capacity to match the 100 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS-10002 ISO 3046 BS 514 the Engine shall consist of the following :- (i) Fly wheel (ii) Flexible coupling with guard bolts and nuts etc. (iii) Alternator (for battery charging) of suitable capacity.
(iv ) Air cleaner heavy duty dry type (v) Fuel injection pump. (vi) Precision governor. (vii) Fuel filter (mounted) (viii) Lubricating oil filters (ix) 24 Volts self regulating alternator belt driven by Engine. (x) Exhaust silencer heavy duty residential type (xi) Starter 24 VDC (xii) Lubricating oil cooler (xiii) Lubricating oil pump (Gear type) (xiv) Turbo charger (xv) Exhaust piping shall not be more than 3.0 meter with asbestos rope lagging covered with aluminium foil caning.
(xvi) Instrument panel electronic type with fault memory complete to be installed out side the sound proof enclosure with :- (a) Starting switch with key. (b) Lubricating oil temperature gauge. (c) Lubricating oil pressure gauge. (d) Battery charging ammeter (e) Battery charging indicating lamp (f) Hour meter with RPM Indicator (g) Safety control against low lubricating oil pressure (h) Over speed stop with double driven adopter. (j) Digital fuel balance indicator.
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to Engine through a flexible coupling and mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-4722. (ii) Type :- Self excited self regulated with automatic voltage regulator. (iii) Rating :- 100 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed :- 1500 RPM (v) System :- 433 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected dip proof. (viii) Ventilation :- Self ventilated (ix) Insulation :- Insulation Class 'H'
(C) AMF panel factory made outdoor kiosk type, free floor mounted totally enclosed fabricated out of CRCA steel 2mm thick, over an angle iron base frame made out of 50 x 50 x 6mm angle iron, hinged front panel door for easy accessibility duly powder coated complete, internal wiring with suitable size copper conductor cable, lugs, ferrules and cable glands for external connection complete suitable for 100 KVA capacity DG set with bypass arrangement complete all as per the specifications given below micro controller based AMF relay includes the parameters like volt, amps, frequency, energy & all engine parameters with protection fuses for panel instrument battery charging system with indicator and cut off relays low and high oil pressure, high speed, over load and earth fault protection, reverse current protection duly wired with flexible copper conductor cable and cable connection with lugs / thimbles complete with necessary control cabling from acoustic enclosure and to the AMF panel for all the operation of safety parameters of the DG set as recommended by manufacturer and as directed by Engr-in-Charge.
Technical specifications:- (a) Copper bus bar 3 phase, 4 wire of 400 A capacity. (b) AC/DC relay. (c) AC/ DC timer. (d) KWH meter. (e) AMF Relay including elctrical wiring. (f) Power contactor, 4 pole, 200 Amps - 02 Nos (Make _ Siemens/ABB). (g) Over load relay. (h) MCCB FP 200 Amps, 35 KA - 03 Nos (DG, Commercial Mains (Out Going ) Make ABB / Siemens. (j) Digital VAFPAF meter for mains and DG set. (k) Frequency meter. (l) Starting switcvh with key. (m) Control MCB SP / SPN 6 to 32 Amps. (n) LED indicators. (o) Battery charger unit with accessories. (p) Hotter 12 Volts. (q) Panel control wiring. (r) DG start stop push buttons.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping. (i) Level indicator. (ii) Drain plug. (iii) MS class 'C' piping for inlet from pump to tank of engine. (iv) Fuel strainer. (v) Fuel tank shall be mounted as per manufacturers instructions. (b) SEMI ROTARY PUMP:- Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5.5 mtr flexible hose pipe of suitable size heavy duty for suction of diesel from barrel. (c) BATTERY :- Maintenance free heavy duty battery two Nos 12 Volt 180 AH connected to the system with multistranded flexible copper lead complete. Make : Exide, Amaron, Standard. (d) BASE PLATE :- Fabricated out of MS channel’s and ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.
(e) TOOLS KIT :- (i) Box type spanner set consisting of 12 spanners-01 Set. (ii) -do- but double end -01 set. (iii) 1 year maintenance spare kit as per maintenance manual of manufacturer. Note:- (i) PCC foundation/platform shall be deemed to be included in the unit rate quoted for above item. (ii) Item rate include for polycarbonate sheet protection alongwith necessary angle iron / GI pipe structure, PCC work etc for protection of DG set. No extra payment shall be made on account of this.
FIRE FIGHTING
Supply and lay cable XLPE Insulated screened PVC bedded, armoured, electric power cables (heavy duty)1100 Volts grade with multi stranded Copper conductor of following sizes:-
(a) 16 Sqmm, 4 Core.
(b) 10 Sqmm, 4 Core.
Supply and lay cable XLPE Insulated screened PVC bedded, un-armoured, electric power cables (heavy duty)1100 Volts grade with multi stranded Copper conductor of size 16 sqmm, 4 Core all as specified and as directed by Engr-in-Charge.
Supply an fix Yard Hydrant/Stand post of 80 mm dia MS with double end flanged type 1.5M height including making reducer arrangement for connecting with flanged MS Pipe line of 150 mm dia all as specified and as directed by Engr-in-Charge.
Supply and fix Canvasfire hose of dia 63 mm and length 15 meter of PIL Dura type conforming to IS 636/1988 Type - A, with proper exterior and interior coatings , including binding charges all as specified and as directed by Engr-in-Charge.
Supply and fix Canvasfire hose of dia 63 mm and length 30 meter of PIL Dura type conforming to IS 636/1988 Type - A, with proper exterior and interior coatings , including binding charges all as specified and as directed by Engr-in-Charge.
Supply and fix gun metal fire hose delivery male coupling/reduced shank coupling having size of 63 mm dia conforming to IS 903 suitable for connecting to hydrant landing valves , hose coupling all incluing of binding with coppper wire all as specified and as directed by Engr-in-Charge.
Supply and fix gun metal fire hose delivery female coupling/reduced shank coupling of male insertion type having size of 63 mm dia conforming to IS 903 suitable for connecting to hydrant landing valves , hose coupling all incluing of binding with coppper wire all as specified and as directed by Engr-in-Charge.
Supply and fix rubber hose of size 20mm and length 30 Meter of type - 2 WP 10 Kgf/Cm2 for first aid hose reel drum, the hose reel shall be properly rolled and connected with inlet and delivery lines all as per IS 444/1987 all as specified and as directed by Engr-in-Charge.
Supply and fix branch pipe with Shut off nozzle 20 mm size with proper clamps for fixing with 20mm rubber hose and incorporated with arrangments for Jet stream, spray and shut off all as per IS -8090 all as specified and as directed by Engr-in-Charge.
Supply and fix Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in 100mm cast iron water supply mains all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, water CO2/Stored pressure Type of 9 liters Capacity conforming to IS : 940/6234), incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, Dry chemical powder (ABC) type of 5 Kg Capacity cnforming to IS : 2171/13849/14609) incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, CO2 type of 6.5 Kg Capacity cnforming to IS : 22878) incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix Fire extinguisher, Mechanical foam (AFFF) type of 9 Liters Capacity cnforming to IS : 10204) incluing mounting brackets all as specified and as directed by Engr-in-Charge.
Supply and fix fire Extinguisher cabniet made of 2mm thick CRCA Sheet, duly coate with fire red colour, front openable doors, provied with acrylic glass on door all for size 1200mm*1200mm*500mm size incluing bottom channels, grouting all as specified and as directed by Engr-in-Charge.
Supply and Fix internal threaded MS Flanges of size 100mm For fixing Fire hydrant landing valve all as specified and as directed by Engr-in-Charge.
Supply and fix Wall mounted Hose Box mae from MS sheet double door made out of 4mmMS Sheet, dually supported with Angle Iron Frames and painted with FIRE RED with firemen locking arrangement of size 8"X8" all as specified and as directed by Engr-in-Charge.
Supply install, test and commissioning LT Feeder distribution Panel (CPRI Approved) cubical type Indoor Confirming to IS 8623 Part 1 1993 factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming MCCB and TPN Copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle have a bottom channel of size 75x40mm duly coated with zinc metal
coating. A detachable predrilled gland plateof thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. 3 mm XLPE adhesive type gasket shall be used to make panel vermin proof , and panel shall be powder coated ( for rust proof) sprayed of approved thickness coated complete as specified and consisting the following :-
(i) Busbar Copper TPN 250 Amps -1No. (ii) Incoming MCCB 4 Pole 125 Amps 415 Volts 365kA-1No. (iii) Outgoing MCCB Four Pole 100 Amps 415 Volts 35 kA - 1 No. (iv) Automatic star delta starter suitable for Main Fire Pump with OLR,NVR, Single phase preventer -1 nos (v) MCCB Fout Pole 25 Amps 415 Volts 16 kA - 1 No. (vi) DOL starter suitable for 5 HP Jockey pump (Frequent ON/OFF Operation) -1 No. (vii) MCCB Single Pole 16 Amps 415 Volts 25 kA - 2 Nos. (viii) VAF PF Meter -01 No. (ix) Indicating Lamps LED Type-03 Nos. (x) One No spare compartments.
Supply, install, testing of MCCB TP 40 Amps, 25 KA, 440 Volt with factory fabricated Power Coated Enclosure made of 3 mm thick CRCA sheet & suitable size to accomodate MCCB. The Enclosure shall be of wall mounted type with front openable doors all as specified and as directed by Engr-in-Charge.
INTERNAL ELECTRIFICATION
Supply & Fix Fluorescent tube light fitting, single tube, 1x28W, 230V, Energy Efficient T5, surface mounted,with and including tube 28W, with automatic electronic ballasts, bipin holder, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-Charge.
Supply & fix Street Light luminaries 1 X 28 Watt with asthetically designed sheet aluminium housing and UV stabilized clear acrylic cover,with lamp and accessories and internal connection with 3 core, 1.5 Sqmm PVC insulated copper conductor cble including fixing arrangement comprising of 25 mm dia GI pipe light grade 1.2 mtr long bend at 120 degree fixed to wall with help of 02 Nos clamp made of flat iron 50x6mm and necessary nut bolt and wahser complete including 28W tube lamp. MAKE: PHILIPS Cat No HSG 120 1 x TL 528 W EBE or Equivalent from Wipro. (If Cat No is revised, equivalent Cat No from Latest Catlauge shall be considered) .
Supply & fix compact flyorescent lamp fitting witrh holder of capacity of 18W DF 3U 6500K with all accessories fixed on walls, on round block of size 80mm dia and 40mm depth open recessed type (2 Nos) and connecting up complete with 23/0.0076 (or equivalent size in mm) flexible three core twisted copper cable all as specified and as directed by Engr-in-Charge.
Supply & fix socket for coaxial cable with and including inner sheet/frame with plate for single module and metal box of size 78 x 87 x 50mm single module complete all as directed by Engr-in-Charge. Cat Part No TV socket HQAM003, cat part of inner sheet / frame with plate HWAI002 and cat part No of metal box is HWAX002 of Indoasian or equivalent make like Legrand or Anchore etc.
Supply & fix coaxial TV cable 75 Ohms double screened aluminium foix and tinned copper conductor type RG11 having signal losses 3.5 db/ 100 yds at 100 MHZ including 20mm dia PVC medium grade concealed conduit complete all as specified and as directed by Engr-in-Charge.
Supply & fix MCB DB SPN, 08 way, horizontal double door type, powder coated sheet steel enclosure - 01 No with following:- (a) MCB, SP, 20A - 01 No (b) MCB, SP, 10A - 01 No (c) MCB, SP, 6A - 03 Nos
Supply & fix MCB DB SPN, 08 way, horizontal double door type, powder coated sheet steel enclosure - 01 No with following:- (a) MCB, SP, 40A - 01 No (b) MCB, SP, 10A - 01 No (c) MCB, SP, 6A - 05 Nos
Fixing only electronic type tamper proof single phase 10 to 40 Amp current rating energy meter alongwith LCD Display and optical port duly saled in place of unservicealbe energy meter including electric connection with single core multi standard copper conductor cable of size 6 sqmm with flexible PVC conduit of proper size complete all as specified and as directed by Engr-in-Chargre. Note :- Meters shall be issued under Sch 'B' free for fixing.
Material and labour for Sub main wiring with two runs of 6 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC concealed conduit heavy duty grade ISI marked 32 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and directed by Engr-in-Charge. Note: Two run of 6 Sq mm cable, one run of 4 Sq mm cable and 1 run of conduit shall be measured as one length.
Material and labour for Sub main wiring with two runs of 4 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC concealed conduit heavy duty grade ISI marked 32 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and directed by Engr-in-Charge. Note: Two run of 4 Sq mm cable, one run of 2.5 Sq mm cable and 1 run of conduit shall be measured as one length
Laying only cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable , (heavy duty), 1100 volts grade with stranded aluminium conductor of following size all as specified and as directed by Engr-in-Charge:- Note :- (i) Cable will be issued under sch 'B' as free for laying only. (ii) Sand cushioning, cable cover & GI pipe for protection etc will be measured & paid separately under respective items of schedule 'A' Part -VIII
(a) 150 sqmm, 3.5 core.
(b) 120 sqmm, 3.5 core.
(c) 10 sqmm, 4 core.
(d) 10 sqmm, 2 core.
SCHEDULE OF CREDIT AMOUNT Rs 3540984.11
M/s Gujarat Construction Company
Vishal Builders
Krishna Construction Company
SOOD ASSOCIATES PVT LTD
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Inderjit Mehta Constructions Private Limited
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
MANGLA AMIT BUILDERS PVT LTD
ENGINEER CONSTRUCTION PVT. LTD.
Ram Parkash Constructions Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid