Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
1 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CM PPD
Administration Building,Sheva
Quotation for Development of Additional Liquid Cargo Jetty at JN Port Electrical works.
2022_JNPT_719074_1
PPD/M-I/Quotation/ALCJ/ Electrical/2022/975
Open Tender
Electrical Works
Works
JAWAHARLAL NEHRU PORT AUTHORITY, SHEVA
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
2 Nov 2022
20 Oct 2022
2 Nov 2022
20 Oct 2022
1 Nov 2022
20 Oct 2022
Amount
Supply of 3Cx300 Sq.mm, Al, XLPE insulation, Flat strip armoured, PVC outer sheath, 18/30kV (E) , FRLS Cable Specification: Cables shall be XLPE insulated, PVC inner sheathed (extruded), armoured, FRLS PVC outer sheathed, stranded compacted aluminium conductor conforming to IS: 7098. 33 kV cables shall be suitable for earthed system. The conductor screen and insulation screen shall both be of extruded semi-conducting compound and shall be applied along with the XLPE insulation in a single operation of triple extrusion process. The metallic screen of each core shall consist of copper tape with minimum overlap of 20% copper screen which shall be capable of carrying the system earth fault current for 2 seconds. Outer sheath shall be FRLS PVC. Approved makes: Havells,Ravin,Gemscab,Gloster,Grandlay,Paramount
Supply of 7CX2.5 sq mm, CU,PVC insulation ,Round wire armoured, PVC outer sheath,1.1KV ,HR+FRLS Cable Specification: Control cables shall be of 1. I kV grade, multicore, PVC insulated, PVC inner sheathed, armoured, FRLS PVC outer sheathed, stranded copper conductor conforming to IS: 1554 Part-I. Up to 5 cores it shall be colour coded and above 5 cores shall be numbered. Approved makes: Havells,Ravin,Gemscab,Gloster,Grandlay,Paramount
Supply of perferated hot dip galvanized GI Cable tray of 600X50 with joints, cover and all required accsesseries. Specification: Supply of perferated hot dip galvanized GI Cable tray of 600X50 with joints, cover and all required accsesseries. Approved makes: Ercon , Indiana , Sumip Composites , Sintex.
150 DIA HDPE DUCT
50 x 10 mm, GI strip GI
Straight through joints for 3cx300 HT XLPE cable considering drum length of 500m Specification: HV Cable termination kit Heat shrinkable type (suitable for indoor installation, ) for 33 kV (E) voltage grade, Al conductor, XLPE insulated, screened, armoured, FRLS PVC outer sheathed power cable with all accessories. Approved makes: Raychem,M-Seal (3M)
Cable termination-3Cx300 Sq.mm, Al, XLPE insulation, Flat strip armoured, PVC outer sheath, 18/30kV , FRLS Cable Specification: HV Cable termination kit Heat shrinkable type (suitable for indoor installation, ) for 33 kV (E) voltage grade, Al conductor, XLPE insulated, screened, armoured, FRLS PVC outer sheathed power cable with all accessories including suitable tinned aluminium lug for cable termination. Approved makes: Raychem,M-Seal (3M)
Cable gland -3Cx300 Sq.mm, Al, XLPE insulation, Flat strip armoured, PVC outer sheath, 18/30kV (E) , FRLS Cable Specification: Supply of nickel-plated, double compression type, Industrial, IP55, brass cable glands, all accessories and fixing material including PVC shrouds suitable for Indoor/outdoor terminations of Al/Cu conductor, XLPE insulated, PVC inner sheathed, galvanised steel armoured, FRLS PVC outer sheathed, power cables as per drawings and documents, for cable sizes as stated below Approved makes: Jainsons,Dowells,Gripwell,SMF.
Installation,Testing and commisioning of 3Cx300 Sq.mm, Al, XLPE insulation, Flat strip armoured, PVC outer sheath, 18/30kV (E) , FRLS Cable with all accsesseries and standerd as per tender Specification: While finalizing Cable routing layouts, consideration shall be given to the requirements of Safety, Reliability and Convenience of cable laying and termination. Where duplicate drives/auxiliaries are provided for reliability, cable routing shall be segregated to the extent practically possible.In cable trenches, distance between bottom most tier and bottom of trench shall be 150 mm.The trunch should be filled with crush sand before laying of cable. clearance from top most tray to top of trench cover shall be 400 mm. Distance between two tiers shall be minimum 250 mm. PCC flooring of built-up trenches shall be sloped in longitudinal and also in transverse direction for effective drainage system. Cables should not be laid directly in the trench floor. Cables trenches should be provided with strong & effective covers with water & fire proof sealing arrangement at trench entry & exit points.
stage.html
html • 0.02 MB
finance_756308.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .