| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.3 L+₹70,065.94 (2.64%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹28.1 L+₹1.5 L (5.74%)Rejected-Finance HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹30.4 L+₹3.8 L (14.5%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹61,320
Closing Date
1 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
PROVN OF CERTAIN SENCTION LBW WORK IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
2021_MES_427818_1
GE SGNR/ TOK-53 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a (i) , b(i) and for un-enlisted, refer NIT para 8.
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹61,320
Yes
10 Apr 2021
4 Mar 2021
3 Apr 2021
4 Mar 2021
1 Apr 2021
11 Mar 2021
60 days
Amount
Excavating over areas, n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Excavating over areas, exc 1.5 m but n exc 3 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
Surface dressing n. exc. 15 cm deep in soft/loose soil and watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
Spreading and levelling in layers n exc. 25 cm thick for well ramming including watering as required in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
M & L for sand filling ( 25 mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
M & L for sand filling ( 40 mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L for 100 mm thick hard core of gauge n. exc 63 mm, deposited spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed by Engineer - in - Charge.
M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundation complete all as specified and directed by Engineer - in - Charge
M&L for Providing precast cement concrete 1: 5:10 Type E-2 (40mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting as in curb stone complete all as specified and directed by Engineer - in - Charge
M & L for PCC 1:1.5:3 Type B –0 (12.5mm graded stone aggregate)as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer - in - Charge.
M & L for PCC 1:2:4 Type B –0 (12.5 mm graded stone aggregate)as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer - in - Charge.
M&L for Providing precast cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting as in curb stone complete all as specified and directed by Engineer - in - Charge
M&L for Providing precast cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and setting in CM (1:4) complete with joints to match complete all as specified and directed by Engineer - in - Charge
M&L for Providing precast cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone wallin). corbels, brackets etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM (1:4) complete with joints to match complete all as specified and directed by Engineer - in - Charge
M&L for Providing precast cement concrete 1: 2:4 Type B-0 (12.5mm graded stone aggregate) 40 mm thick jallies (mea sured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately and setting in CM (1:4) complete with joints to match complete all as specified and directed by Engineer - in - Charge
M&L for reinfoced cement concrete Type B-1 (1:2:4) Nominal Mix (20mm graded stone aggregate) as in slabs suphorted on wall, beams and columns in floor/roofs landings, balconies deck slabs, lintels, bands, capings and in shelves and similar work complete all as specified and directed by Engineer - in - Charge.
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in - Charge
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer - in - Charge
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Engineer - in - Charge.
M&L for Damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, 40 mm thick, type B-0 including necessary formwork complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for form work to sides & soffits of suspended slab such as roof slabs, floor slabs, landings and similar work; n. exc. 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for formwork to to sides of pillars, posts, struts, piers, columns and stanchions including for edges for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
S & F alluminium anodised barrel tower bolts 150mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer - in - Charge.
S & F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge
S&F alluminium body door closer hydraulically regulated, designation No. 2, universal type, suitabel for door shutters upto 701 to 850 mm in width and of weight not more than 36 to 60 kg complete all as specified and directed by Engineer-in-charge.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-charge.
M&L for TMT bars 8 to 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in - Charge.
M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specifed and directed by engineer-in-charge.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay with glazing bars, complete all as specified and directed by Engineer - in - Charge.
S&F powder coated aluminium door shutters of aluminum section weighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, handels 2 nos in each door, hinges, powder coated aluminium beading, screw etc. complete all as specified and directed by Engineer - in - Charge.
S&F powder coated aluminium windows and ventilator shutters, side hung type without sash bars, aluminium saction weighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as aluminium peg stay 150mm long (1No), powder coated aluminium hinges type B-21 100 mm long (2No), suitable powder coated aluminium handle -(1No), and powder coated aluminium self closing tower bolt 75mm long (1No) complete all as specified and directed by Engineer - in - Charge.
S&F anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer - in - Charge.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by Engineer - in - Charge.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed by Engineer-in-charge.
M & L for 75 mm thick cement concrete 1:3:6 type C –2 (40mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge.
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in flooring, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 25 mm thick cement concrete 1:2:4, Type B-0 (20 mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for 25 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded aggregate) as in flooring finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for virified ceramic tiles 10mm thick (square / rectangular) area of each tile exc. 0.18 sqm but n. exc 0.36 Sqm in floors etc. laid over and including 15 mm thick screed bed in CM 1:4, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge
M&L for virified ceramic tiles 10mm thick (square / rectangular) area of each tile exc. 0.18 sqm but n. exc 0.36 Sqm in skirting/dado etc,. laid over and including 10 mm thick backing coat in CM 1:4, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles interior grade, of size 450x600x7 mm thick as on vertical surfaces like dados or skirting laid over and including 15mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 5 mm thick rendering in CM 1:3 on ceiling surfces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for rendering 20mm thick in CM 1:4 on fair faces of brick work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plaster surfaces of walls and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, over a coat of chalk whiting complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of chalk whitingcomplete all as specified and directed by Engineer-in-Charge.
S & F 4mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in suqares n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer - in - Charge
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge
S & F Galvanised steel water tubing 20 mm bore light grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in cable crossing and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings to laid in trenches complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded white colour polyethylene water storage tank 500 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as secified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having three layres )
S & F 15mm bib tap cast copper alloy,brass chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge.
S & F 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. Make:- Parryware cat part no-T3501A1, Prayag cat part No- 8304, CREA cat part No. -F3002101
S&F 15 mm bore stop cock / valve fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore stop cock / valve concealed fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer - in - Charge.Note:- (Minimum weight 15mm-90gms/ 20mm- 92gms)
S&F 15mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer - in - Charge.Note:- (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
S&F PVC connections 15mm size with PTMT nut of length 600mm complete all as specified and directed by Engineer-in-Charge.
S&F 100mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 100mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
M & L for 100 mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer - in - Charge.
M & L for PCC 1:3:6 type C –2 bed to drain pipes 150 mm including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer - in - Charge.
M&L for Salt - glazed stone ware drain pipes 150mm bore laid in trenches and jointed complete all as specified and directed by Engineer - in - Charge
S&F vitreous china urinal, bowl type (back or corner wall type), complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plug with and including 60mm long brass screws and brackets, 32mm bore LDPE flush pipe of pressure rating 6 Kg/ Cm2 and grating and union for discharge pipe, waste coupling of PTMT minimum weight 60 gm, including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer - in - Charge.
S&F water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests and CI 'P' trap and proper connecting to flushing cistern complete all as specified and directed by Engineer-in-charge.
S&F 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 32mm dia and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
S&F vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
Demoliton of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer - in - Charge
S&F drapery curtain rod 25 mm dia , fancy type, fabricated out of chromium plated sheet not less than 20 guage, including brackets and pair of decorted end knobs (finials), stop roller etc, pretreated powder coated natural color complete all as specified and directed by Engr-in-charge.
S&F factory made powder coated aluminium grills to aluminium windows of size 50mmx5mm thick including all necessary fixing arrangments complete all as specified and directed by Engineer - in - Charge.
Providing and fixing PVC false ceiling consisting of 600mmx600mmx6 mm thick plain PVC sheet used as panel insert in a framework made using powder coated aluminium T-section of sizes(25mmx25mmx1mm thick) in square pattern of grid sizes of (600mmx600mm). The aluminium framework is supported from the ceiling with the help of GI hook and GI wire/ 6mm MS rods of required sizes to maintain proper level etc. The aluminium framework is supported on the wall side with use of aluminium L section of size (25mmx25mmx2mm thick) angles etc complete all as specified and directed by Engineer - in - Charge. (PVC ceiling Make : Rajshree or equivalent of Sintex or Polycon, Aluminium T and angle Make:-Hindalco,Indalco,Jindal).
S & F mild steel clamps made out of 40x6 mm by 5 mm flat iron in two halves for tapping through 100 to 300 mm bore GI/DI water pipe line including drilling and welding of 15/20 mm GI socket and necessary rubber insertion, nut, bolts & wahers complete all as specified and directed by Engineer-in-charge.
M&L for bends, Tapers, Tee pieces (single and double branch), nipple any type and angle/reduis and straight connecting pieces complete all as specified and directed by Engineer - in - Charge
S & F Fiber Glass Reinforced plastic (FRP) Door Frames of required colour of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides, MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge
S & F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge.
M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -99 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -99 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 99 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 99 here in before but one light point controlled by two (2) ways switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 99 here in before but one call bell point complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S & F modular switch 5/6 Amp single pole one way one module with white cover plate with frame, alongwith metal flush box 1/2 module complete all as specified and directed by Engineer - in - Charge
S & F modular switch 5/6 Amp single pole two way one module with white cover plate with frame, alongwith metal flush box 1/2 module complete all as specified and directed by Engineer - in - Charge
S & Fmodular switch socket combination 5 pin, 5/6 Amps 5 in 1 with white cover plate with frame, 3 module alongwith metal flush box 3 module flush type complete all as specified and directed by Engineer - in - Charge
S & F modular switch socket combination 6 pin 5/16 Amps with white cover plate with frame, 3 module alongwith metal flush box 3 module flush type complete all as specified and directed by Engineer - in - Charge.
S & F modular Socket outlet 5 pin 5 Amps with white cover plate with frame, alongwith metal flush box 1x2 module flush type complete all as specified and directed by Engineer - in - Charge.
S & F modular bell push with white cover plate with frame, alongwith metal flush box 1/2 module flush type 5 Amps complete all as specified and directed by Engineer - in - Charge
S & F modular stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F electronic bell AC 230 volt single pole ding dong type complete all as specified and directed by Engineer - in - Charge
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F industrial socket metal clad plug and socket with MCBs single pole 20 Amps complete all as specified and directed by Engineer - in - Charge.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
S & F sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn and including steel 25 mm dia "medium quantity" PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surface and white wash or existing colour, necessary junction box and cover including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
Supplying, laying and testing in replacement 6 Sqmmx 2 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
Supplying, laying and testing in replacement 16 Sqmmx 2 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F in replacement water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S&F ceiling fan of size 1200 mm sweep with BEE 5 star rating single phase 230 volts, 50 Hz complete 3 blades including canopy, fan hook, hanging rod, fan regulator stepped type complete all asspecified and directed by Engineer - in - Charge.
S&F wall mounting fan of size 400 mm sweep with BEE 5 star rating single phase 230 volts, 50 Hz complete 3 blades including canopy, fan hook, hanging rod, fan regulator stepped type complete all asspecified and directed by Engineer - in - Charge.
S&F security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M
S & F recess mounting 2x2 feet 36 watt LED luminaire with powder coated CRCA housing with LEDs, seamless front frame with high transmission acrylic cover and fixed electronic driver (surge protector ) complete all as specified and directed by Engineer - in - Charge . Make :-crompton cat part No. LCTLRNE-36-FO-CDL or equivalent make in Bajaj , havells
S&F Exhaust fan with high speed noiseless motor of size 280 to 300 mm sweep,900 rpm metlic body, heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.02 mm of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
S&F Exhaust fan with high speed noiseless motor of size 300 mm sweep,900 rpm PVC body, heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.02 mm of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
Supplying, laying, jointing, testing and commissioning single face sluice gate as per IS 3042 rising spindle type 600x700 mm with head stock and hand wheel and bevel gear box operated with cast iron frame, door, head stock and head wheel as per IS 210 FG 200, brass seat as per IS 291, ss spindle 1.5 meter as per AISI 410, carbon steel bolts and nuts as per IS 1367 complete all as specified and directed by Engineer-in-Charge.
Structural steel work welded in bulit up section, trusses and frame work including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Note : Amount of credit of Rs 0.00 for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
M/S BUDHRAM BISHNOI
R B Infrabuilders
KHANNA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .