Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 24 FLOWER STREET FLOWER STREET SAIDAPET CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹26.2 L
EMD Value
₹52,484
Closing Date
25 Nov 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical Tender)
O/o Sr. Chief Engineer (Electrical), BSNL TamilnaduElectrical Zone, 5th Floor Tamilnadu Telecom Complex,No.60,EthirajSalai,Chennai - 600008
Operation of all EM Services, mtce of EI and fans and comprehensive mtce of Substation, pumps,S/T AC units ,W/TAC unit , cassette type AC units , DG sets, AFD system and lightning conductor at RGMTTC , Chennai for 24 months.(2024-2026)
2024_BSNL_214539_1
48/CEE/BSNL-TNEZ/2024-25
Open Tender
Electrical Works
Item Rate
730 days
Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash), O/o CGM, BSNL, Chennai
₹52,484
26 Nov 2024
14 Nov 2024
26 Nov 2024
14 Nov 2024
25 Nov 2024
14 Nov 2024
14 Nov 2024 - 18 Nov 2024
SUB HEAD- I Providing need based operation of the following electro mechanical services from 6 am to 8 pm including sundays/ holidays as per the standard procedures and carrying out scheduled maintenance activities given in the of relevant sections of specifications/condition of contract and inventory of equipment attached by deploying the required staff including specialised manpower and by arranging required tools and plants etc., to keep all the services operational up to the required standards, complete as required for RGMTTC Chennai. This scope includes attending the breakdown faults in EMS components also for which materials shall be supplied vide Sub Head III of this schedule. a) EI & fans i/c compound lighting b) Pumps-8 nos c) 11 KV/400 V , 2 Nos x 400 KVA transformer Sub station system i/c outdoor structure and all accessories of HT panels,MV panels, changeover panel and capacitor panels * d) Engine Alternator sets - 2 nos ( 200 KVA & 350 KVA**) e) Automatic Fire Detection system. *Note: HT to LT Conversion is in progress, operation of substation is to be carried out till the LT conversion work is completed. After LT Conversion, MV Panels, changeover panel and Capacitor panels will remain in the scope of operation. ** Agency has to do the general maintenance of 350KVA EA set(excluding spares) and test run the 350KVA engine once in a month by connecting the battery available with 200KVA engine and keep the EA set in proper working condition. All the above consists of 1 job
SUB HEAD- II Providing Comprehensive maintenance of the following Split type AC units i/c stabilizer/starter/MCB ( whichever is available) as per the detailed specifications to keep all the services operational up to the required standards, complete as required
1.0 TR Split type AC Unit of life more than 5 years from installation ( i/c compressor )
1.5 TR Split type AC Unit of life more than 5 years from installation ( i/c compressor )
1.5 TR W/T type AC unit Life more than 5 years from installation ( i/c compressor )
1.5 TR Inverter type Split Type AC Units less than 5 years from installation ( excluding Compressor since guranteed for 5 years by AC manufacturer )
1.5 TR Inverter type Split Type AC Units more than 5 years from installation (i/c Compressor )
Providing Comprehensive maintenance of following electromechanical services (as per the inventory list attached) situated in the RGMTTC , Chennai as per specifications/ conditions of contract & as per the details given in relevant sections by deploying the required staff including specialized man power and by arranging required spares, tools and plant etc. to keep all the services operational up to the required standards, complete as required.
200 KVA Engine Alternator Set - 1 no
Pumps of following capacity
1.5 HP Submersible in ground (Bore well)
1.5 HP Jet pump near Auditorium/Block8 (Bore well)
1.5 HP Jet pump at Type 'D' qtrs (Open well)
3HP Mono bloc pumps at Type 'D' qtrs'(open well)
3HP Open well submersible at Type 'D' Qtrs
3HP Mono bloc at CV Raman Hostel (Open well)
1.5 HP jet pump at CV Raman Hostel (Open well)
Automatic Fire Detection system.
Lightning conductor
SUB HEAD - III Supplying the following accessories in the existing Fitting, Fan, switch board, MCB DB and Submain distribution Board switches etc as required. Note: These items shall be replaced only if the items under maintenance becomes faulty & with the consent of EE (E) /SDE(E) / JTO(E).
36 W/ 40W Fl. Tubes
Starters for FL. Fittings
28W T-5 Tubes (Philips or SS make)
2.5 mfd capacitor for ceiling fan
Replacing of bearings in the fan
Rewinding of coil in the Ceiling/Wall mounting /pedestal fan
Bearing for 18" exhaust fan
Rewinding of 18" exhaust fan
Bearing for 12" exhaust fan
Rewinding of 12" exhaust fan
5A one way piano type switch (Make:Anchor or SS make)
5A, 5 pin socket (Make:Anchor or SS make)
15A one way piano type switch (Make:Anchor or SS make)
5/15 A 5 pin socket (Make:Anchor or SS make)
100 W fan regulator suitable for 230 V , 50 HZ (Make: Anchor or SS make)
11W / 9W CFL Lamp
18W CFL lamp
5W LED lamp for Night Lamp fitting
9W LED lamp for Study/Reading Lamp fitting
11 watts PLC lamp 2 pin ( Make Philips or SS make )
11 watts PLC lamp 4 pin ( Make Philips or SS make )
5-32A C series SP MCB (Make:Standard or SS make)
5-32A TP MCB (Make:Standard or SS make)
63A TP MCB (Make:Standard or SS make)
100A 4P isolator (Make:Standard or SS make)
63A 4P isolator (Make:Standard or SS make)
40A DP Isolator (Make:Standard or SS make)
63A DP isolator (Make:Standard or SS make)
32 A , TPN SDFU of open execution type (Make: L&T model FN 32 TPN or SS make)
63 A , TPN SDFU of open execution type (Make: L&T model FN 63 TPN or SS make)
125 A , TPN SDFU of open execution type (Make: L&T model FN 125 TPN or SS make)
32A HRC fuse ( Make: L&T or SS make )
63A HRC fuse ( Make: L&T or SS make )
100A HRC fuse ( Make: L&T or SS make )
125A HRC fuse ( Make: L&T or SS make )
Heavy duty , 3 KVAR Power capacitor suitable for 440 V (Make: L&T box series or SS make)
Heavy duty , 5 KVAR capacitor suitable for 440 V (Make: L&T box series or SS make)
LED driver suitable for 30W street light fitting
LED driver suitable for 60 W street light fitting
20 Watts - 4 feet - LED type Tube Fitting including LED lamp (Make: Crompton Order code - LDDR20-CDL or Similar Superior make)
60W-LED type Street Light fitting with all accessories ( Make : Havells ENDURASUNDOWNSL60WLED765PASYBOTG or SS make)
Fire Extinguishers & its Accessories.
Pre charged 4.5 Kg CO2 type Fire extinguisher with Controllable Discharge Mechanism, Discharge Hose & Horn confirming to IS etc. as required. (Make: ISI marked) (Explosive certificate from the competent authority shall be produced).
ISI marked dry Chemical Powder fire extinguisher of 5 Kg capacity with all accessories etc., as required.
PVC Horn & Hose with suitable length suitable for the existing Fire extinguisher cylinders
Fire Buckets of capacity 9 Ltrs (2nos) as per IS
Refilling of 4.5 Kg Co2 type extinguishers in the existing Cylinder , including engaging suitable man power/ensuring safety measures & using specialized tools & safety gears if any, i/c testing and transportation etc as required.
Wiring with 3x1.5 Sq.mm PVC insulated copper wire i/c suitable size PVC conduit
Wiring with 3x6 Sq.mm PVC copper wire i/c suitable size PVC conduit
Wiring with 3x4 Sq.mm PVC copper wire i/c suitable size PVC conduit
S/D of 1 x 1.5 sq,.mm PVC copper wire in existing conduit
S/D of 14 SWG copper wire for loop earthing
S/L of 3 x 1.5 Sq.mm PVC insulated and FR PVC Sheathed 1.1 KV grade Copper Cable for compound lighting
Providing Suitable end terminations for 3 x 1.5 Sq.mm PVC insulated and FR PVC Sheathed 1.1 KV grade Copper Cable
Providing General oil service for the existing 350 KVA EA set by providing "B" check kit comprising of Fuel filters, Air filters, Lub oil filters,super bypass filters, set of "O" rings,gaskets etc complete removing the old elements replacing with new elements,i/c supplying and filling of 15W/40 Lub oil, coolant in the cummins Engine upto required level, draining and buyback of old lub oil testing the engine for 10 minutes on load by engaging skilled manpower etc complete as required.
SAIDAPET ELECTRICALS CHN PVT LTD (BID ID -771092)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .