Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.8 L+₹1.8 L (3.98%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹48.2 L+₹2.2 L (4.81%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹48.4 L+₹2.5 L (5.34%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.3 L+₹3.3 L (7.27%)Rejected-Finance 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | L5 | Rejected-Finance Being higher bid value |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
18 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8954/E8
2021_MES_445821_2
GE/ALP(8954) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
334 days
GE ALIPORE KOLKATA
Class D and Category b i
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹92,000
Yes
27 Sept 2021
29 Jul 2021
20 Aug 2021
29 Jul 2021
18 Aug 2021
12 Aug 2021
60 days
Amount
Comprehensive maintenance of Central Gas supply System complete and its allied equipments including minor repair of manifold panel for Oxygen- 200 Points, Nitrus Oxide-12 and vaccum system-165 Points, Air 51 points, CO2 -07 Points, pipe line, Three nos Air Compressor pump/motor and cylinder and empty indication system for a period of 11 calender months. Note : Unit rates shall deemed to be inclusive of taking down unserviceable defective parts/accessories and replacement with new one, including fixing of spare parts as and when required including welding/soldering etc for smooth and efficient functioning of the system ,changing of lubricating oil (Castor-30) of two nos vaccum pump once in a year ,complete all as specified and directed at site. (New spare parts shall be measured and paid separately as supply only under relevent item here-in-after) and if any spare required except undermentioned here-in-below is included with the quoted rates.
Supply only OR - 14 regulator for oxygen & Nitrious control pannel as per sample. Complete all as specified and as directed.
Supply only gauge for oxygen & Nitrious 0 to 14 Kg as per sample. Complete all as specified and as directed.
Supply only non Return valve for oxgen & Nitrious manifold as per sample. Complete all as specified and as directed.
Supply only self seal double lock valve for oxygen as per sample. Complete all as specified and as directed.
Supply only self seal double lock valve for Nitrious as per sample. Complete all as specified and as directed.
Supply only self seal double lock valve for vaccum as per sample. Complete all as specified and as directed.
Supply only safety keyed plugh for oxygen as per sample. Complete all as specified and as directed.
Supply only safety keyed plug for Nitrious as per sample. Complete all as specified and as directed.
Supply only safety keyed plug for Vaccum as per sample. Complete all as specified and as directed.
Supply, Installation, Jointing, Testing and Commissioning in repair of following Medical grade Copper Pipe line with suitable fiittings. .Copper pipe shalll be solid drawn,seamless,deoxidized,non arsenical,half hard,tempered and degreased material conforming to BS:EN:13348:2001+A1:2005. Fittings would be made of copper and suitable for a steam of working pressure of 17 bar and conforming to BS:864 with specially made for brazed socket type connection.Complete all as specified and as directed. (Certified 18-04-57). Make- Metal Alloys/Max flow or equivalnet certified manufacturer.
42mm OD X 1.2mm wall thickness
28mm OD X 0.9mm wall thickness
22mm OD X 0.9mm wall thickness
15mm OD X 0.9mm wall thickness
12mm OD X 0.7mm wall thickness
Supply, installation, testing and commissioning in repair of Gas outlet points/terminal units with matching probes for Oxygen, Nitrous Oxide, Medical Air 4 Bar/7 Bar, CO2, front loading type, BS type. Complete all as specified and as directed.
Oxygen Port.
Vacuum Port.
Supply and fixing in repair LINE ISOLATION VALVES Complete all as specified and as directed for following sizes of valves :-Make- Matrix/Hospitech service and sales/Zoloto/RN/JSI or equivalent as approved bu Accepting Officer
15 mm valve
22 mm valve
28 mm valve
42 mm valve
54 mm valve
12 mm valve
Supply only in repair adapter pipe line for oxygen as per sample. Complete all as specified and as directed.
Supply only in repair copper tail pipe for oxygen/nitrous gas including 5/8 Hex-nut, nipple, head connection with KE nipple Complete all as specified and as directed.
Supply only in repair humidyfire bottle including BPC flow meter for oxygen Complete all as specified and as directed.
Supply only in repair ward vaccum unit including regulator, gauge for showing negative pressure and 600ml receiver jar Complete all as specified and as directed.
Supply only in repair reciever Jar for ward vaccum unit 0 - 600 ml Complete all as specified and as directed.
Material and labour for applying one coat of synthetic paint to medical gas pipe line for oxygen, Nitrious & vaccum with proper colour coading (for oxygen- white colour, for Nitrious- Blue colour & for Vaccum- Yellow colour) after cleaning/scrapping of old paint Complete all as specified and as directed by the Engr-in-charge.
Cutting the existing gas/vaccum pipe line for supply, insertion of suitable size of tee for taking out new point as required including necessary arrangement like soldering/welding etc Complete all as specified and as directed.
Supply only in repair parkolet outlet valve for Medical gas as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair adaptor outlet for medical gas as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair Operation theater vacuum unit as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair line pressure gauge for control panel of O2/N20 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair bonnet for OR-14 regulator for oxygen/nitrous as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair spring for OR-14 regulator for oxygen/nitrous as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair diaphgram OR-14 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair diaphgram carrier as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair diaphgram plate as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair O-ring (big/small) as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair nipple inlet flat as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair filter inlet as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair brass ring for OR-14 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair seat nylon as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair PA screw for OR-14 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair safety valve as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair outlet Iox -69 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair outlet OR-14 as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair copper tube connection for non return as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair gasket for BPC jar as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair gasket for vacuum jar as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair HP tubing for oxy/nit/vac as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair LP tubing for BPC flow meter as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair saddle for copper tubing 12 mm dia as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair saddle for copper tubing 15 mm dia as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair saddle for copper tubing 22 mm dia as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair saddle for copper tubing 28 mm dia as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only in repair,PB Amico 02 (Wall Mounted) Outlet with 3/8 BSB thread probe Complete all as specified and as directed.
Supply only in repair, PB Amico vacuum (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed.
Supply only in repair, PB Amico Air (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed.
Supply only in repair, PB Amico N2O (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed.
Supply only in repair, PB Amico CO2 (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed.
Supply only in repair,2 Gas Alarm (Analogue type) Complete all as specified and as directed.
Supply only in repair,2 Gas Alarm (Digital type) Complete all as specified and as directed.
Supply only in repair,3 Gas Alarm (Analogue type) Complete all as specified and as directed.
Supply only, in repair,3 Gas Alarm (Digital type) Complete all as specified and as directed.
Supply only in repair,4 Gas Alarm (Analogue type) Complete all as specified and as directed.
Supply only in repair,4 Gas Alarm (Digital type) Complete all as specified and as directed.
Supply and fixing in repair, connecting and Testing a Semi Automatic oxygen control panel with following accessaries- (a)OR -14 Regulato-2 nos (b) IOX-69 Regulator-1 no (c) Line pressure Gauge-1 no. (d) pressure gauge -2 nos (d) Alarming facilities Complete all as specified and as directed. Make- Hospitech service and sales/ JAMEX/Medical Gas system/Krishna surgical/Oasis Medical/Amico/MN Life care
Supply only in repair Oxygen BPC flow meter with Humidifier bottle for bed head panels Complete all as specified and as directed.
Supply only in repair Ward vacuum unit with 600 ML receiving jar for bed head panels Complete all as specified and as directed.
Supply only in repair Modular type theatre suction unit, with central control system and with two sets 2000 MI receivig jar fixed Complete all as specified and as directed.
Dismantling and opening the motor from Air Compressor system in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same in original position. Capacity of motor is 15 HP 3 PH. Complete all as specified and as directed.
Supply only Piston with pin LP for Air Compressor (02Sets) as per sample. Complete all as specified and as directed.
Supply only Piston with pin HP for Air Compressor(01Sets) as per sample complete all as directed by Engr-in-charge. Complete all as specified and as directed.
Supply only Needle bearing with seal LP for Air Compressor (02Sets) as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only Needle bearing with seal HP for Air Compressor (01Sets) as per sample Complete all as specified and as directed by Engr-in-charge.
Supply only Cylinder LP for Air Compressor as per sample complete (02 Nos) Complete all as specified and as directed by Engr-in-charge.
Supply only Cylinder HP for Air Compressor as per sample complete (01Nos) Complete all as specified and as directed by Engr-in-charge.
Supply only Valve LP with packing set for Air Compressor as per sample complete(02Sets) Complete all as specified and as directed by Engr-in-charge.
Supply only Valve LP with packing set for Air Compressor as per sample complete (01Set) Complete all as specified and as directed by Engr-in-charge.
Supply only Filter element for Air Compressor as per sample complete (02Nos) Complete all as specified and as directed by Engr-in-charge.
Supply only pendent outlet valve for for oxygen Complete all as specified and as directed.
Supply only pendent outlet valve for for Nitrous oxyde Complete all as specified and as directed.
Supply only pendent outlet valve for vaccum. Complete all as specified and as directed.
Supply only pendent outlet valve for CO2. Complete all as specified and as directed.
Supply only pendent outlet valve for for Air Complete all as specified and as directed.
Supply only Brass non Return valve for oxgen & Nitrious for control pannel as per sample. Complete all as specified and as directed.
Supply only Air pressure controlling Regulator valve whith inlet outlet dia 20 mm for (0 to 10 Bar) Air delivery line Complete all as specified and as directed. Make - JANATICS /Hospitech service and sales or equivalent
Supply, Installation testing and commissioning in repair Fully Automatic Oxygen Control System with minimum constant flow out put 1500 lpm at 4.2 bar pressure for oxygen. It shall comprises with the manifold shall be a fully automatic type and shall switch from "Bank in use" to "Reserve Bank" without fluctuation in delivery supply line pressure and without the need for external power. After the switch over the reserve bank shall then become the Bank in use and vice versa. The control panel incorporates 3 large Red illuminated LED Display for the left Bank, the right bank and for the supply pressure complete with all necessary items required for execution. Complete all as specified and as directed. Fully autyomatic oxygen control pannel should comply with the following features :- (a) Fully automatic self contained shuttle-calue. (b) Fully automatic changeover No valve or lever to reset after each changeover. (c) Dual line pressure regulators. Make- Medical Gas system/Activa/Krishna surgical/Oasis Medical/Amico/MN Life care/Hospitech service and sales/ JAMEX Note- Material shall be purchased from authorised dealer or directly from Company.Purchase vouchar and all test certifuicates shall be submited to Engineer in charge before execution of work.
Supply and fixing in repair oxygen manifold system consisting of (6 X 4) Nos. of oxygen cylinders. Manifold should be suitable to withstand a pressure of 145 Kg/cm2, along with high pressure copper annealed tail pipe with SS breading and end brass adapter suitable for oxygen cylinders and manifold. Top frame comprising of high pressure copper pipe of size 1/2" ID X 15 SWG with high pressure brass fittings made of high tensile brass and connection through non return valve high pressure copper tail pipes made of high pressure copper pipe of size 1/4" NV X 15 SWG. The design of middle and bottom frames shall be provided to fit both round and flat bottom cylinders safely. The manifold shall be tested (hydraullically) at 3500 psi and necessary test certificate acompany along with the supply. Complete all as specified and as directed. (Certified 18-04-57) Make- Medical Gas system/Activa/Krishna surgical/Oasis Medical/Amico/MN Life care/Hospitech service and sales/ JAMEX Note- Material shall be purchased from authorised dealer or directly from Company.Purchase vouchar and all test certifuicates shall be submited to Engineer in charge before execution of work.
Frazco Enterprise
Tirupati Buildcon Pvt. Ltd.
TOTCO
Shanti Construction Company
SEN ELECTRIC WORKS
NUPUR CONSTRUCTION
DK Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .