| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹44.6 L+₹3.6 L (8.80%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹45.0 L+₹3.9 L (9.62%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹46.4 L+₹5.3 L (13.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹47.9 L+₹6.9 L (16.8%)Rejected-AOC OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC Rejected |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Jun 2024, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
ROOF TREATMENT/ REPAIR TO ROOF SHEETS AND CONNECTED WORKS UNDER AGE B/R-II OF GE(N) MAMUN
2024_MES_656890_1
GE(N)/M-15/2024-25
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹1 L
6 Sept 2024
30 May 2024
20 Jun 2024
30 May 2024
18 Jun 2024
13 Jun 2024
Amount
Note for Ser item No 02 to 04 :- 1.1 The guarantee period of water proofing treatment as executed under relevant items of Sch `A` shall be 05 years (or as per manufactures gurantee which ever is more) and the contractor shall be responsible to keep the entire bldgs free from leakage/seepage for a period of 05 years after the certified date of completion of the work. An amount of Rs 18000/- to as per scale of performance security i.e of total of sum of quoted rates of these items which-ever is more shall be kept reserved out of contractor`s final bill as security deposit during Guarantee period of 05 years. The contractor may give a separate interest bearing security deposit to GE valid for 05 years for this amount alternatively. 1.2 Should the GE at any time during or prior to expiry of said Guarantee period of 05 years, find that leakage/seepage has been caused to the bldgs, the contractor, on demand in writing from the GE will forthwith undertake to carryout water proofing treatment at his own expense till expiry of the Guarantee period of 05 years. In the event of contractor`s failure to comply with GE`s direction within the stipulated period, the work shall be carried out at the risk and cost of the contractor. The liability of the contractor shall not however extend beyond of the period of 05 years from the certified date of completion, unless the notice was served to the contractor previously to rectify such defects. 1.3 Work under these items shall be executed through authorised applicater of the main manufacturer, approved by the GE.
M&L for water proofing to internal surfaces of walls using white cementituous one component waterproof coating in two coats complete all as specified and described below :- (a) Remove all the loose adhering material like dirt, dust, organic solvent and oil etc. from the surface using emery papers, chiesel, or wire brush etc.completly. (b) Wash surface properly with clean water, allow the surface to dry completely before application of the product (incase of efflorescence, surface should be cleaned throughly to remove all loose particles from Interior surface). (c) Surface cracks shall be filled (< 3mm) by crack filler products and bigger cracks, damaged portion and hollow areas shall be repaired by white level plast. (d) Apply first coat on the cleanand dry surface uniformly with the help of painting brush after thorough mixing white cementituous one component waterproof coating. Apply 2nd coat cross wise after 4 to 6 hrs when the coated surface is completly dry (The total thickness of both the coats shll be limited to maximum 1.5mm).
M&L for water proofing to external surfaces of walls using white cementituous one component waterproof coating in two coats complete all as specified and described below :- (a) Remove all the loose adhering material like dirt, dust, organic solvent and oil etc. from the surface using emery papers, chiesel, or wire brush etc.completly. (b) Wash surface properly with clean water, allow the surface to dry completely before application of the product (incase of efflorescence, surface should be cleaned throughly to remove all loose particles from Interior surface). (c) Surface cracks shall be filled (< 3mm) by crack filler products and bigger cracks, damaged portion and hollow areas shall be repaired by white level plast. (d) Priming coat with cementituous one component heat reflecting waterproof mix with 100% of water (e) Apply first coat on the clean and dry surface uniformly with the help of painting brush after thorough mixing white cementituous heat reflecting waterproof coating mixed with water 60-65% of water . Apply 2nd coat cross wise after 10 to 12 hrs when the coated surface is completly dry. (The total thickness of both the coats should be limited to maximum 1 mm)
M&L for water proofing to external surfaces (horizontal surfaces or on roof) using white cementituous one component waterproof coating in two coats complete all as specified and described below :- (a) Remove all the loose adhering material like dirt, dust, organic solvent and oil etc. from the surface using emery papers, chiesel, or wire brush etc.completly. (b) Wash surface properly with clean water, allow the surface to dry completely before application of the product (incase of efflorescence, surface should be cleaned throughly to remove all loose particles from Interior surface). (c) Surface cracks shall be filled (< 3mm) by crack filler products and bigger cracks, damaged portion and hollow areas shall be repaired by white level plast. (d) Priming coat with cementituous one component heat reflecting waterproof mix with 100% of water. (e) Apply first coat on the clean and dry surface uniformly with the help of painting brush after thorough mixing white cementituous heat reflecting waterproof coating mixed with water 60-65% of water . Apply 2nd coat cross wise after 4 to 6 hrs when the coated surface is completly dry. (The total thickness of both the coats should be limited to maximum 1 mm)
Dismantling of brick tile or terracing tiles with bedding layer of mortar etc and removal of rubbish beyond MOD land complete all as specified & directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish beyond MOD land complete all as specified and directed.
M&L for brick tiles terracing with 40mm thick brick tiles bedded on 15mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified & directed.
M&L for brick tiles terracing (using old tiles obtained from dismantling) bedded on 15mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified & directed.
M&L for PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof mixed with WPC as per manufacturer's instruction, surface finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately.
M&L 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth mixed with liquid water proofing compound as per manufacturer instruction including raking out joingts, hacking for key, scrubbing down with water etc complete all as specified and directed. Note : WPC shall be measured separately.
M&L for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet walls to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP having a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm using butane torch by torch application with 10cm side laps and 15cm end overlap of membrane.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet walls to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP having a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm using butane torch by torch application with 10cm side laps and 15cm end overlap of membrane. (d) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm or as prescribed by manufacture of membrane/ directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified & directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, and removal of rubbish complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating 275 GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed.
All as per item No 16 but 0.50mm thick plain pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L false ceiling of 8mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders of standard galvanised sections in a grid size of 600x600mm, complete all as specified and directed. Make: M/s Saint Gobain or equivalent of Armstong/Everest
S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) fixed with self tapping screws complete all as specified and directed.
M & L Plain cement concrete 1:5:10 type E2 using 40mm graded crushed stone aggregate as in sunken floors portion including demolition of PCC & removal of rubbish complete all as specified and directed.
M&L 10 mm thick cement plaster in cement mortar 1:3 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid separately)
M&L for bitumen blown of any grade, applied hot, two coats to concrete/plastered surfaces at the rate of 1.5 Kg per sq m per coat and applying polythene film black, 50 micron complete for sunken floor slab and embedded in side wall / covered fillet complete all as specified and directed.
Dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 15mm thick screed bed or bedding layer of mortar in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450x300x7mm set and jointed (joint free) in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltr capacity, inlet and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and directed.
S&F in repair vitreous china, squatting Pan 'Orissa' pattern 'white' size 580mm x 440mm white with integral footrest including provision of lean concrete bedding, connection to drain out pipe, flush pipe, flush pipe and anti syphonage pipe etc, making good to floor where required complete all as specified & directed.
S&F in repair Vitreous china wash down water closet pan pedestal pattern, white (excluding supply of flushing cistern and flush pipes, but including fixing thereof), including making connections to trap, and to flush pipe including plastic seat and cover with stainless steel or aluminised hinging device and fixed complete all as specified and directed.
S&F plastic water closet seat cover, closed pattern with flat bottom and cover (as per sample) and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed.
M&L for 15mm thick plaster in two layers (10+5mm) in cemet mortar 1:4 external layer of plaster shall be mixed with liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc, surface finished even and smooth with using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid for separately.
M&L for preparing new plastered surface of wall and appying two coats of cement base paint mixed with silicon based water repellent compound over a coat of primer by roller/brush complete all as specified & as directed.
M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of walls, applying wall care putti to make the surface smooth and applying two coats of oil bound distemper complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on concrete surface of ceiling, chajja etc, finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered ceiling surface and applying three coats of white wash complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing of pipe 15mm bore complete all as specified and directed.
S&F 15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.
Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing of pipe 20mm bore complete all as specified and directed.
S&F 20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.
Refixing of old steel tubing 20 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc all as specified
Dismantling of water tank RCC/HDPE/Ferrocrete etc of size 250 Ltrs to 500 Ltrs capacity, removal from site and disposal beyond MOD land complete all as specified and directed.
Dismantling of water tank RCC/HDPE/Ferrocrete etc of size 500 Ltrs to 1000 Ltrs capacity, removal from site and disposal beyond MOD land complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) two layers, Capacity 500 litres, ISI Marked including all accessories, hoisted and fixed in position all as specified in SSR Part-I land complete all as specified and directed..
M&L for Rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) two layers, Capacity 1000 litres, ISI Marked including all accessories, hoisted and fixed in position all as specified in SSR Part-I land complete all as specified and directed..
Disconnecting water tank (from Roof Slab/staging of single/double/Triple story bldg), float valve with float arm, outlet pipe from PVC service water tank, emptying stored water through wash outlet, cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes finally washing the internal surfaces with bleaching powder, closing wash outlet, re-fixing water tank, float valve and out let in proper position, replacemt of old PVC top cover with proper hinge type cover as per sample including minor repairs if required and testing of capacity 250 litres to 500 liters complete all as specified and directed.
Disconnecting water tank (from Roof Slab/staging of single/double/Triple story bldg), float valve with float arm, outlet pipe from PVC service water tank, emptying stored water through wash outlet, cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes finally washing the internal surfaces with bleaching powder, closing wash outlet, re-fixing water tank, float valve and out let in proper position, replacemt of old PVC top cover with proper hinge type cover as per sample including minor repairs if required and testing of capacity 500 litres to 1000 liters complete all as specified and directed.
S&F 20mm bore dia ball valve (minimum weight- 210 gms), high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete, fixed in repair all as specified & directed.
S&F in repair 20mm bore dia gun metal globe or gate valves (as per sample) cast copper alloy chromium plated fancy type, ISI marked with crutch or butter fly handleswith iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fitting, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.
S&F for 75mm bore PVC(SWR) rainwater pipes including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.
S&F for 110mm bore PVC(SWR) rainwater pipes including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.
S&F PVC (SWR) 110mm bore bends any radius, complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius, complete all as specified and directed.
S&F PVC (SWR) 110mm bore junction single, (Single T) equal or unequal with acces door complete all as specified and directed.
S&F PVC (SWR) 75mm bore junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F in repairs Grating doom 125 mm dia with waste hole/ without hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
S&F in repair 15mm bore dia Bib taps long body, cast copper alloy, chromium plated fancy type ISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore dia angle valve / stop valve cast copper alloy chromium plated (as per sample)fancy type, long shank ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair over head shower rose 125mm size (square/circular as per sample) for 15mm bore pipe, cast copper alloy Chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union complete all as specified & directed. Make - Jaquar, Marc and Johnson
S&F in repair towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed.
Cleaning of water tank at existing position( at Roof Slab/staging of single/double/Triple story bldg), emptying stored water through wash outlet, cleaning and removing all sludge, scale and dirt, etc. from tanks, washing the internal surfaces with bleaching powder of capacity 500 litres to 1000 liters including writing the date of cleaning on tank with white synthetic enamel in prescribed manner complete all as specified and directed.
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 75,421.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
Abrol construction co
M/S DUGGAL CONSTRUCTION CO
dadwal engineers
M/s Northern India Construction co
WALIA ENTERPRISES
kailu construction co
KEWAL SONS
RD Engineers
AV ENTERPRISES
KUMAR TRADING CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .