Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAdmitted-Finance | ₹9.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.7 Cr+₹95,687.26 (0.10%)Admitted-Finance 504 MANGAL MURTI HEIGHTS RANI BAGAN HARMU ROAD RANCHI | RANCHI | JHARKHAND | 829205 | ₹9.7 Cr+₹95,687.26 (0.10%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Seth Kumar L1 | ANAND CONSTRUCTION INFRASTRUCTURE PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 722.22 | Cum | 200 ₹1,44,444 | 159.26 ₹1,15,020.76 Lowest |
| 2.00 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) | 209.08 | Cum | 30 ₹6,272.4 | 16.27 ₹3,401.73 Lowest |
| 3.00 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). | 440.37 | Cum | 200 ₹88,074 | 135.2 ₹59,538.02 Lowest |
| 4.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 1,014.14 | Cum | 750 ₹7,60,605 | 618.4 ₹6,27,144.18 Lowest |
| 5.00 | Extra for flooring work for each consecutive floor above first floor complete as per direction of E/l | 270 | Sqm | 30 ₹8,100 | 21.38 ₹5,772.6 Lowest |
| 6.00 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 7,892.41 | Sqm | 450 ₹35,51,584.5 | 346.53 ₹27,34,956.84 Lowest |
| 7.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 533.85 | Sqm | 550 ₹2,93,617.5 | 368.99 ₹1,96,985.31 Lowest |
| 8.00 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. | 626.36 | Meter | 2,250 ₹14,09,310 | 1,516.61 ₹9,49,943.84 Lowest |
| 9.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1%:3 (1 Cement: 1% coarse sand (zone-lll) : 3 graded stone aggregate
20 mm nominal size} | 424.8 | Cum | 6,200 ₹26,33,760 | 5,204.85 ₹22,11,020.28 Lowest |
| 10.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | 285.57 | Cum | 6,200 ₹17,70,534 | 4,327.56 ₹12,35,821.31 Lowest |
Tender Value
Refer Docs
EMD Value
₹9.2 L
Closing Date
28 Feb 2023, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya Dhurwa, Ranchi-834004.
Remaining work of Community Health Centre, Bhawnathpur, Garhwa
2023_JSBCC_66162_2
JSBCCL/150/ 2022-23
Open Tender
Civil Works - Buildings
Item Rate
365 days
Garhwa
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹9.2 L
19 Apr 2023
8 Feb 2023
2 Mar 2023
8 Feb 2023
28 Feb 2023
8 Feb 2023
Amount
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Extra for flooring work for each consecutive floor above first floor complete as per direction of E/l
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1%:3 (1 Cement: 1% coarse sand (zone-lll) : 3 graded stone aggregate 20 mm nominal size}
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll} : 3 graded stone aggregate 20 mm nominal size}.
Providing 25mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips coarse sand of 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3.0 including screening shuttering mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Centring and shuttering icluding strutting propping etc and removal of form for foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams. girders. bressumers and cantilevers.
Extra for brick work for each consecutive floor above first floor including watering and scafolding, all complete as per direction of E/l.
Extra for R.C.C. or P.C.C. work for each consecutive floor above first floor complete as per direction of E/l.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern
Providing Tor steel reinforcement of all dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for Tata (Tiscon),SAIL,JSPL,Electrosteel Steel Ltd.Bokaro &Vizag ( RINL)
Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 do-do
Providing Tor steel reinforcement of 10mm.,28mm,32mm Dia. bars as per approved design and drawing -do- -do -
Providing Tor steel reinforcement of 12mm,16mm,20mm,25,Dia. bars as per approved design and drawing -do- -do-
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :v) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.vi) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.vii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area.viii) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd./ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green.
1st coat should be applied @1.50 kg/SQM/coat For the purpose of measurernent tte entire treated surface will be measured."(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ SQM/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.The Watqrproofing Brand:*Sil<a Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)D Protection of treated with pcc :-
The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltemsall corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening, shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curing,taxes and royality all complete as per buitding specifiction and direction of E/l.Panels that has been left should be casted next day. There should be 6 mm gap between Panels .Brand?Sika _Plastocrate plus, MYK proof WP10, Fosrac- Conplast X421 ic , Dr Fixit Pidiproof LW
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing & mixing liquid integral water proofing compound in concrete or plaster all complete as per bldg.specification and direction E/I
Provrding and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 125 mm thick reinforced designation 75A brick work in C.M. { 1:4} in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/l.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
|Providing 1.5mm. cement punning including curing, carriage of water withall leads and lifts as per building specification and direc?tion of EA,
Providing 12mm. thick water proof cement plaster (1:3) with clean coarse sand of F,M 1.5 with 5% cico or any other approved water proofing compound including. including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in wall dado,skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l
Providing and laying 25 mm thick white makrana marble stone slab flooring of approved quality over 19mm. thick base of lime mortar (1:1:1) ( Lime putty : surkhi: coarse sand ) laid and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. 300X300MM SINGLE
Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19mm. thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specificationand direction.{iv} 600x600 mm size
Providing and laying 25mm. thick kotah stone tiles in risers of steps, skirting and pillars of approves size, texture and colour laid over 12mm. thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing te granolilthic finish with approved quality -do?
Providing and laying 6mm. precast white glazed tiles in walls over 12mm. cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes, and royalty all complete as per building specification and direction and of E& l.
With "A" grade white Tiles.
With commercial grade colour
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete
Providing and laying 6mm thick mosaic flooring of approved texture and colour over 25 mm thick P.C.C. (1:2:4) base with 10 mm down stone chips and sand of F.M. 2.5 to 3 rubbed and polished to granolilthic finish with approved quality of carborandum stone, top layer of 6 mm. being laid with 4 mm and down marble chips of approved quality and shade in ratio (1:2) cement and marble dust mixed in ratio of (3:1) by weight of marble chips including casting in approved block, curing, taxes and royalty all complete as per building specification and direction of E/l (b) With 100% white cement:-
Providing and laying 6mm thick mosaic in skirting dado, steps and pillars of approved yexture and colour over 12mm thick cement plaster (1:3) base with sand of F.M. 1.5 rubbed and polished to granolithic finish, with approved quality of carborandum stone top layer of 6mm being laid with 4mm and down marble chips of approved quality and shade in ratio (1:2) cement and marble dust mixed in ratio (3:1) by weight of marble chips including cost of curing, royalty and taxes all complete as per building specification and direction of E/I.(b) With 100% white cement:-
Providing & Fixing flexible Conductive PVC sheet flooring of Armstrong/ Forbo/ Polyflor having a total thickness of 2mm and weight of 3kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REACH Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Equivalent to Armstrong PASTELL. Installation:It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be leveled by self leveling compound.
The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room.
Providing and laying of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge.
Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing & fixing Rockfone Stonewool Acotsical Ceiling PACIFIC High NRC (0.80), Fire Rating A1 (EN 13501-1), RH 100% (No visible deflection in high humidity), Superior Class Light Reflection, Sag Resistant 12mm thick Ceiling Tiles of size 600x600 A-Edge (Square) with AntiBacterial Properties & M1 Class Emission Certification made up with Natural Stone (Bassalt Rock) a complete Green Product & perfect suitable for any kind of False Ceiling application in builiding & costruction. The Visible side is a smooth white painted fleece, the Rear side: back fleece with complete facctory finish Painted edges.
Supply and installation of Wallflex PUR Vinyl Sheet wall covering manufactured by Armstrong World Industries, Inc, 1.5m wide, having a nominal total thickness of 1mm. The nominal thickness of the wear layer would be 1mm. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors shall be dispersed throughout the thickness of the wear layer. Wallflex shall conform to Group M of Wear Resistance as per EN 660-2, Fire resistance of group 2 as per AS/NZS3837, Residual indentation of ≤0.10mm as per EN433, curling after exposure to moisture ≤8mm as per EN434, Seam strength of mean≥240N/50mm as per EN684.Make of : Armstrong/Polyflor/Forbo
Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100x16x3mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15x10x10 cm size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/l.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l.
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
Providing G.I pipe hand rails with 40 mm dia G.I. pipe of I.T.C. or equivalent make properly fitted and fixed in position to rail posts with all necessary accessories and taxes all complete as per building specification and direction of E/l.
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:"Profile B"
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing wooden moulded beading to door and window frameswith iron screws, plugs and priming coat on unexposed surface etc.complete :50 x 20 mm
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Providing 50x150mm teak wood Handrail with good quality of teak wood of av. 2. 5M. length with smooth finishing and rounded edges properly fitted to the railing including cost of spirit polishing of approved shade and make all complete as per drawing specification and direction of E/l.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer’s specification and direction of Engineerin-Charge
Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm,painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and jointwith the help of PVC solvent cement & self driven self tapping screws.Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge.Non decorative finish
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing LEAD LINED DOOR,including hinges, jamb, lock jamb, bead and if required hinges 2.5 mm thick with mortar guards,lock,closer,all complete as per derection by Engineer-in-charge: LEAD LINED DOOR
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing in position about 50mm thick border and 35mm thick design Jali at all levels made from Glass fibre reinforced concrete (GFRC) using white cement, Quartz Sand, AR Fibres, Water Plasticizers & pigments in approved shape, size and length as per the design and drawings and as per specifications, mix design and test results given below. The typical Screen should be of sizes as per the drawings. Fixing of GRC Jali shall be with help of S.S. Screws Fixtures, M.S Angle Cleats, Fissure Plug, and Dowel Pin proper alignment as per drawings (Shop drawings to be Submitted by the contractor before the work start). As per approved paint, shade & Finishing with GRC powder & filling the joints with Epoxy sealant neatly between GRC screen and primary structures. The Screen should be in absolute straight plumb line and length and joins between channels should be neatly filed to make seamless uniform surface across the entire elevation of the building without any visibility to joints. Any framework to be paid extra as per item.(GRC Screen)
Carriage of Materials
Local Sand-Lead 6 Km
Coarse Sand-Lead 8 Km
Stone Chips-Lead 20 Km
Stone Metal- Lead 20 Km
Bricks- Lead 8 Km
Suppling all materials, labpour and toools & equipment for drilling 200X15mm dia bore well in all kinds of soil & rock by using & D.T.H. supering machine all complete as per approved design, building specification and direction of E/I.
From 0-50 meter
From 51-100 meter
From 101-150 meter
From 151-200 meter
From 201-250 meter
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Suppling & commissioning of 5H.P submershible pump of reputed made ISI Marked suitable for 200mm X 150mm dia tube well head of 90 mtr. With lowering 50mm dia coloumn pipe 60 mtr. 4sq mm finolex cable with pannel board, main switch,starter, voltmeter, aminator, on- off switch H.R.C. fuse unit, lighting arrangement all complete as per building specificatuion & direction of E/I.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 14.14.2-150 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
PLUMBING WORK
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Supplying, fitting and fixing vitreous white glazed earthen ware l.W.C. of parry Hindustan or any other l.S.S.approved make with 100mm H.C.l. 'p'trap lS litres C.l. pull and let go flushing cistern of names or other l.S.S.equivalent make, complete with allfittings,C.l. or C. C.brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.l. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 1Smm C.l. body brass spindle stope cock of weight not less than SOgrms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(c) V)/ith 10lit. low level PVC cistern
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other l.S.S. approved make supported on painted C.l. or R.S. brackets 32mm C.l.brass waste, 15 mm dia C.l. body brass spindle stop cock of approved quality of weight not less than 350gpms, 32mm PV.C. waste pipep0mm long with biais coupling at oileend and making plumber joint$etc. all complete as per specification and direction of E/1.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing P.T.M.T flange 15mm dia 56mm long suitable for 15mm taps and weighing not less than 5 gram(Prayag or equivalent).
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Cutting holes up to 30x30 cm in walls including making good the same:
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia with 25 mm waste hole
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Supplying fitting and fixing C.P brass towel rail 20x600mm with bracket container as per specification and direction of E/I.
Supplying fitting and fixing C.P brass towel rail 20x600mm with bracket container as per specification and direction of E/I.
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Supplying fitting and fixing C.P brass shop dish container medium size with screw and hinges as per specification and direction of E/I.
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
15 mm dia nominal bore
20 mm dia nominal bore
Supplying laying & fixing G.I pipes with red lead and yarn of following nirmal bore with screwed and socketed joints on walls ceilling and floor including suppplying and fitting of wall hooks or pipes clamps, wooden plug cutting pipe of size and threading ends if required etc. all complete as per specification & direction of E/I.
15mm nominal bore.
20mm nominal bore.
25mm nominal bore.
Supplying and fitting gun Metal following valve of approved quality all complete as per specification & direction of E/I.
20mm dia
25mm dia
Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. 15mm dia
Supplying and fixing G.I fittings of approved make all complete as per specification & direction of E/I.
ELBOW
Tee Plain
Reducing Socket
Nipple
Union Socket
Jam Nut
Socket plain
Cutting chajja or concrete for laying G.I pipe and restoring the same with R.C.C (1:2:4) brick work in cement mortar (1:4)and cement plaster (1:4) as per specification and direction E.I.
Making hole in wall for G.I pipe and restoring the same all cost complete 250mm thick
U-PVC pipes (working pressure 4 kg / cm²) Single socketed pipe 110 mm dia
Supplying and fixing P.V.C fittings of approved make confirming to ISS 1729 including supplying nails and bobbins lead and yarn for making lead candled joints including earth work for providing scaffoldingas the case may be all complete as per specification and dire ction of E/I
a) P.V.C single junction with ear & door 100mm dia(wt.20.5 Kg app.)
b) P.V.C plane tee - 100mm dia.
c) P.V.C plane bend - 100mm dia.
d) P.V.C double junction with door & ear- 100mm dia.
e) P.V.C door bend - 100mm dia.
f) P.V.C side door bend (Right/Left) - 100mm dia.
g) P.V.C cowel - 100mm dia.
h) Floor trap- 100 mm dia
i) Ring rubber
j) Solvent cement
k) Lubricant-
l) Door piece-
32mm ball valve
25mm ball valve
C.P. flange
White cement
Providing & fixing special type bath room fittings all complete.Special type of C.P. Bath room fittings for V.l.P. Buildings (JAL, Jaquar, Marc or equivalent make) (lSl Marked)
vi) Angular Stop Cock (Long Thread) (lSl Marked)
xviii) Shower with revolving joints
Supplying material and labor for constructing inspecction chamber of designation class 75A bricks size 750mm deep 600X450 mm internal dia mention having 250 mm wall thickness in cement mortar (1:6) including 12mm cement platser (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I cover with frame (weight not less than 36 Kg) along with P.C.C (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
construction of P.C.C Pedestal all r.C.C (1:2:4) 5'-0")and +3" thick with cement plaster and punning all cement complete.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
25 mm dia nominal bore
32 mm dia nominal bore metre 424.70
40 mm dia nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameterand 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm
Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required :
Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.(i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.
Single tee with door (110x110x110 mm)
Single tee without door(110x110x110 mm)
Bend 87.5°(110 mm bend)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 100mm P.V.C. plain bend with door and ear
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.Rectangular shape 600x450 mm internal dimensions
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
ELECTRICAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2X1.5sq.mm-+ 1X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2X1.5sq.mm-+ 1X 1.5 sq. mm earth wire
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group-A
Group-B
Group-C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. .
Wiring for light) power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2x1.5sq.mm+1x1.5 sq.mm.earth wire
2x2.5sq.mm+1x2.5 sq.mm.earth wire
2x6sq.mm+1x6 sq.mm.earth wire
4x2.5sq.mm+2x2.5 sq.mm.earth wire
4x6sq.mm+2x6 sq.mm.earth wire
4x10 sq.mm+2x10 sq.mm.earth wire
4x16 sq.mm+2x16 sq.mm.earth wire
4x25sq.mm+2x25 sq.mm.earth wire
Supplying and drawing following pair 0.6 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25mm PVC conduit
32mm PVC conduit
MB-supplying fitting and fixing of metal box of 150mm x150mmx60mm size etc.as requried with taxes all complete as per approved design,drawing and electrical specification and direction of E/I
100mmx100mmx60mm
150mmx150mmx60mm
200mmx300mmx100mm
250mmx350mmx100mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amp switch
15/16 mp switch
4-3 pin 5/6 amp socket outlet
5-6 pin 15/16 amp socket outlet
Telephone socket outlet
Supplying fitting and fixing of metal box of 150mmx75mmx60mm size deep(nominal size)on surface or in recess with suitable size phenolic and fixing 6 pin 5/6 or 15/16 socket outlet and 15/16 piano type switch connection,painting etc.as required with taxes all complete as per approved desiggn,drawing and electrical specification and direction of E/I
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing brass batten / angle holder including connection etc as required.
Supplying and fixing call bell/buzzer forDC/AC single phase230 volt complete as required.
Installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper cond.
Istallation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. upto 450 mm sweep
Supplying and fixing of following way rewired single pole and neutral sheet steel M.C.B. sonumer unit with 240 volts on surface/recess complete with tinned copper bus-bar,earth bar,din bar,hinged front acrylic cover for the MCB knobs detachable gland plate interconnections including painting earthing etc.as required with taxes all complete as per approved design drawing and electrical specifaction and direction of E/i(with set/RCCB Isolator) 2x8 way
Supplying and fixing of following way three pole and neutral prewired sheet steel M.C.B.distribution board 415 volts on surface/recess complete with loose wire box terminal blocks,duly prewitred with suitable size F.R.PVC insulated copper conductor uoto terminal blocks tinned copper bus-bar,neutral link earth bar din bar detachable gland plate interconnections phospatised and power painted including earthing etc. as required with taxes ,all complete as per approved design drawing and electrical specifaction and direction of E/i(with set/RCCB Isolator)
4 way (4+12)double door
6 way (4+18)double door
Supplying installation testing and commissioning of surface/recess founting vertical type 415 volt prewired TPN MCB distrubution board of sheet steel dust protected duly phosphatised and powet painted inclusive of 200 amps tinned copper bus bar for mounting MCB's detachable gland/knock out plate and with built in loose wire box and superior make terminal connector for all incoming and outgoing circuit duly prewired with adequate size of F.R.PVC insulated copper conductor uptoo the terminal connector/neutral link and ready for installation of following ways etc.as required with taxes allcomplete as per approved design drawing and electrical specification and direction of E/I(but without MCB and incomer) 4 way (4 + 12), Double door
Supplyingand fixing plug in box with supplying, installation testing and commissioning of TPN plug in box of following capacity on existing overhead bus bar system complete with HRC fuse links, electrical interconnection, erathing etc. as required with taxes all completeas per approved design, drawing and electrical specification and direction of E/I. 32 amps
MCCB.Supplying and fixing 5 amps to 32 amps rating, 240 volts, "B" series ,miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. with taxes ,all complete as per approved design drawing and electrical specifaction and direction of E/i(with set/RCCB Isolator)
Supplying and fixing following raiting four poles 415 volt isolator in the in the existing MCB DB complete with connection testing and commissioning etc. as required. with taxes ,all complete as per approved design drawing and electrical specifaction and direction of E/i(with set/RCCB Isolator)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 300milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
EAR8GCUWR-Supplying and laying 8 SWGcopper wire at 0.50 mtr below ground level for conductor earth electrode including soldering etc.as required with taxes allcomplete as per approved design drawing and electrical specification and direction of E/I.
Providing and fitting of lighting conductor final made of 25mm dia 300mm long etc. as required with taxes all complete as per approved design, drawing and electrical specifications and direction of E/I.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells .
S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required.
60W LED Street Light
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm).
1m Single Arm Suitable for 70MM Top
Supply Installation, testing and commissioning of floowing rating surface mounted LED tube light fitting suitable for 230V 50H2, single phase supply etc. complete as required.
Bulk Head fitting with 9/10Watt LED.
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. Make :- Usha/Crompton / Havells .
1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
Supply Installation, testing and commissioning of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary acc$sories as required.I'x 2' LED Panel light
Supply Installation, testing and commissioning of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary acc$sories as required.I'x 2' LED Panel light
Supply Installation, testing and commissioning of floowing fitting with 9/10 Watt CFL/LED.
TRANSFORMER Design, manufacture, supply, installation, testing and commissioning of 200 KVA, 11 KV /0.415 KV, 3 phase, 4.5 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with off Load Tap changing arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 10% in steps of 2.5% each, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level 2 [0.78 KW at 50% load & 2.23 KW at 100% load shall not exceeds by 5.0% (@ 11 KV) of the maximum total loss values.Transformer 200KVA
DIESEL GENERATING SET Supply, Installation, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 14 / 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
200 KVA With AMF Panel
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)
150 mm dia (wall thickness - 4.8 mm)
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
MAIN L.T. PANEL WITH PLC BASED LOAD MANAGER
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel , floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required.
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.
The breaking capacity specified for all ACB's and MCCB's breakers is Ics value (service rating).
Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose.
All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
INCOMERS from 1 Nos. 200 KVA Transformer
1 No. 400 Amp FP Moulded Case Circuit Breaker & 1 No 400 Amp 4 Pole Contactor.
Protection releases / relays, Metering & Accessories for each Transformer incomers
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Master trip relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 200/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 200/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 no. CT's of ratio 200/5A, Class 5P10 for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Power factor meter.
Frequency meter.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from 1Nos. 200 KVA D G sets
1 No. 400 Amp FP Moulded Case Circuit Breaker & 1 No 400 Amp 4 Pole Contactor.
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Trip Circuit Supervison relay.
Reverse power relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 600/5A , Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 600/5A , Class 5P20 accuracy 20 VA each burden for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (250 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers.
1 nos. 100 amp FP MCCB (25 KA) with KWH meter for Solar Incomer.
BUS COUPLER
1 nos 630 AMP Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.
OUTGOINGS:
01 Nos. 315 Amp TP MCCB (25 KA)
04 Nos. 250 Amp TP MCCB (25 KA)
01 Nos. 200 Amp TP MCCB (25 KA)
01 Nos. 160 Amp TP MCCB (25 KA)
07 Nos. 100 Amp TP MCCB (25 KA)
02 Nos. 63 Amp TP MCCB (25 KA)
Main LT Panel as described above
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 75 KVAR A P F C Panel consisting of 5 / 10 / 25 KVAR (at 415 Volts rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 .
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
All out going MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.
AC3 duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.
INCOMING
Incomer circuit breaker has been included in the main panel.
1 set- 3 CTs , ratio 160 / 5A Class 1.0 accuracy 15 VA burden for metering.
Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 6 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.
BUS BARS
200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints.
OUTGOINGS
Capacitor Panel as described above
DISTRIBUTION PANEL-
L+P PANEL (CHC BLOCK )
INCOMING
1 No. 250 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 160 Amp FP MCCB (25 KA)
01 Nos.63 Amp FP RCCB (300 mA).
06 Nos. 25 Amp FP MCB (10 KA)
02 Nos. 40 Amp FP MCB (10 KA)
14 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
UPS PANEL
INCOMING
1 No. 160 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP Copper busbar with coloured heat shrinkable sleeve.
OUTGOING
01 No. 63 Amp FP MCCB (25 KA)
06 Nos. 25 Amp FP MCB (10 KA)
08 Nos. 40 Amp FP MCB (10 KA)
06 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
AC PANEL-01 (OUT DOOR TYPE)
INCOMING
1 No. 200 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
02 Nos.63 Amp FP RCCB (300 mA).
03 Nos.40 Amp FP RCCB (300 mA).
Panel described as above
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker (25 KA) with 100 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 40 Amp DP MCB (10 KA)
Panel described as above
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 240 Sqmm, 11 KV XLPE
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 35 sq.mm PVC Insulated cu wire including termination etc.
Supply Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.
4 core, 2.5 sq.mm.
10 core, 2.5 sq.mm.
12 core, 2.5 sq.mm.
Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
FIRE FIGHTING WORKS
PUMPS
1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra.
2. All the Fire Fighting works shall be done in compliance of Fire Fighting authority requirement.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
CONTROL PANELS
Supplying,Installation,testing & commissioning of dust & vermin proof double door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCA sheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.
Incomming
100 Amps. 16ka breaking capacity 4 pole MCCB-1 Nos.
Set of 3 phase indication lamp-1 Set
100 Amps. 4 strip insulated bus bars-1 Nos.
Outgoing
63 Amps. 10ka breaking capacity 3 pole MCCB--2 Nos.
Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.- 2 Set
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 x 25 sqmm ( 28 mm )
3.5 x 50 sqmm ( 35 mm )
3 X 10 sq. mm (22mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.
4 core, 25 sq.mm. Aluminium Armoured
3.5 core, 50 sq.mm. Aluminium Armoured
3 core, 10 sq.mm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (PDowncomer/Floor)
25 mm dia
100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65 mm dia
80 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe. (FOR FHC )
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.
150 mm dia
80 mm dia
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 25 mm Dia
Supply & Fixing of 6 Kg ABC MAP-50% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2018 Marked. Location : Open General Area, Inside FHC,
Providing and Fixing of CO2 Portable 4.5 Kg Fire extinguisher, Carbon-Dioxide type Flat base Horn Including Valve, High Pressure Rubber Wire Braided Discharge Hose of not less than 10 mm dia. & complete in all respects including initial fill with CO2 Gas confirming to IS:15222. and IS 15683:2018 Marked. Location : Inside Electrical Room, Pump Room,
Providing and Fixing of Portable 4kg Clean Agent HFC-236fa Fire Extinguisher, Gas UL Listed under EPA SNAP, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), Suitable for Class A,B and C & Electrically Started Fires, Conforming to IS 15683:2018 Marked. Location : General Office Area, Inside of Critical Rooms i.e. Server Room, UPS Near Rooms, Fire Control Room etc.
HVAC WORK
Air Cooled Inverter Ductable Unit Supplying, installing, testing and commissioning of Air Cooled Invertor Split type Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expension kit to connect with DX AHU, and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonary Pedastal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM represantative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
11.0 TR Ductable Split Unit -Only Condensing
DIRECT EXPENSION FLOOR MOUNTED AHU (DX FMAHU)
Supply, installation, testing and commissioning of factory fabricated Double Skinned DX Type Air- handling unit floor mounted fabricated out of extruded aluminium section with 0.8mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm polished SS sheet inside with backward curved fan in supply and forward curved in exhaust with fan section and fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 row cooling made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc. without face and bypass dampers. The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS The complete AHU shall conform to standard specication with starter Panel. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
AHU Units Mounted on MS Frame/Masonary Pedastal with required anti-vibration mounting.
3000 CFM Supply Air, 8 Row CC, 125 mm St. Pr., For Supply Fan, Supply Fan, 1000 CFM Ex. Air Blower, 40 mm St. Pr. for Exhaust fan with other accessories as specified)
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene40 mm ID
Supply. Installation, testing and commissioning of factory fabricated G.I. Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Grills and Dampers G.I construction Duct Dampers / Volume Control Damper
Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification.
Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioning as per specification.
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille. 200 mm
Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep.
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50mm
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure of suitable for VRV Outdoor Unit. 63A 4P MCCB(16 KA)
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.
A) Power cabling (XLPE insulated Aluminum / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc. as per specification.
Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment's (Indoor & Outdoor) shall be done by HVAC Contractor.
4C x 16 Sq. mm Copper Conductor (Armoured) For VRF Unit
4C x 10 Sq. mm Copper Conductor (Armoured) For AHU/Vent
4C x 6 Sq. mm Copper Conductor (Armoured) For AHU/Vent
4C x 4 Sq. mm Copper Conductor (Armoured) For AHU/Vent
MEDICAL GAS PIPE LINE
Supply, Installation, Testing and Commissioning of Medical Gases Pipeine System .Oxygen System
4 + 4 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes as per Technical Specifications enclosed.
Semi Automatic Control Panel for Oxygen with inlet for Liquid Oxygen Tank, as per Technical Specifications enclosed
1 + 1 Cylinders Emergency Oxygen Manifold with two stage High flow rate regulator with NRV for every cylinder and copper tail pipes as per Technical Specifications enclosed
Terminal Units (Gas Outlets) with probes/Adaptors ,CE certified , as per Technical Specifications enclosed.
Oxygen Flowmeter with Humidifier Bottle as per Technical Specification enclosed
Oxygen H.P Antiastic rubber tube
Compressed Air System including Duplex 36.66 cfm , 2 HP Motor, air cooled, oil free compressors and Air Drier, After Cooler, Moisture Saprater and 1# Air Receiver & Filteration system as per Technical Specification enclosed,
Terminal Units (Gas Outlets) with probes/Adaptors CE Marked, as per Technical Specifications enclosed.
For C.Air ( 4 bar)
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded as per Technical Specification enclosed.
Vacuum System Duplex V X 15 Vacuum Pumps of Ingersoll with Motor each with receiver vessel, with bacteria filter capacity as per Technical Specification enclosed.
Terminal Units (Gas Outlets) with probes/Adaptors CE Marked, as per Technical Specifications enclosed.
Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with bracket as per Technical Specification enclosed,
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded as per Technical Specification enclosed.
Combined Electrical Control Panel for Compressed Air System and Vaccum System as per Technical Specification enclosed.
Copper Pipes used will be solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased, manufactured as per EN 1057 part I, Table-X of 1971 and chemical composition as per BS-6017 of 1981, Table 2, Cu-DHP.
42mm OD X 1.2mm thk
28mm OD X 1 mm thk
22mm OD X 0.8 mm thk
15mm OD X 0.7 mm thk
12mm OD X 0.7 mm thk
Valves Boxes with Pressure Gauges as per Technical Specifications.
2 Gas Services ( O2, Vac, Air 4)
3 Gas Services ( O2, Vac, Air 4)
Area Alarm as per Technical Specifications enclosed
2 Gas Services ( O2, Vac, Air 4)
3 Gas Services ( O2, Vac, Air 4)
Isolation Valves as per Technical Specifications enclosed
Bed Head Panels
Horizontal Bed Head Panel (Al Extruded) 4 ft. Long Provision for Gas Outlet, Electrical Switch & Socket, Nurse Call, etc
MAJOR OT
Laminar Air Flow System Providing & installation of Planair Ceiling System. Constrcuted out of 2 mm thick extruded aluminium sheets of size 2,400 x 2,400 mm having 2 nos. of Hepa Filters. The Hepa Filters having dust spot efficiency of 99.99%, 0.3 microns. Provided with Perforated Aluminium Air Diffuser for the plainair ceiling to give a Laminar Flow of filtered Air. Air Supply System and ducting work including return air duct to be done by Air Conditioning Contractor.
Manual Sliding Door System Supply, installation, testing & commissioning of sliding type Hermatically Manual OT door having high density particle board cores, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H). Manual Door (1500 mm x 2100 mm)(
Surgeon Control Panel SITC OF Surgeon Control Panel membrane type, mounted flush in the theatre wall, comprising of the following: 1 No. Day Time Clock 1 No. Elapse Time Clock 1 No. Medical Gas status/ alarm 1 No. HEPA status/ alarm 1 set indicator only fortemperature and humidity display Size ‐ 650 X 650 X 115 m
Storage Unit Supply & instalaltion of Storage Unit size 1666 x 865 x350mm having two shelves, made 1.5 mm thick EGP with 120 microns. With Antifungal and Antibacterial surface coating. Having 5 mm thick acrylic sheet & mounted flush with the theater wall.
Single Arm Pendant Providing & fixing of double arm multi moveable surgeons pendant as per technical specs attached.
OT Light OT Light with Provision of Camer Operating Room Surgical Lighting System provide an ideal combination of brightness, maneuverability, and shadow resolution without sacrificing colour accuracy through a consistent LED technology. Such Lighting System have the following technical specifications • Number of Light heads : Two per suspension • Color Temperature range: 3500K to 4500K • Field Size Diameter : Small field D50: 18cm / Big field D10: 26cm • Working Range : 750 to 1100mm (+/- 10%). • Illumination Level :Focusmatic technology, we should provide 160 000 lux at the central illumination spot (Ec) at small field AND big field. There not be drastic loss of illumination level at the central illumination spot (Ec) when shifting to big field Controls : On/off + Endo Mode button & 3 optical sensors to control in a touchless and sterile way the following parameters: light intensity (6 steps from 50 000 Lux to 160 000Lux), colour temperature (3500 K, 4000 K & 4500 K) & • Surgical Light System be compliant with relevant CE Marked
OT Table Universal General Purpose Operating table having five section top,perineal cut,detechuing leg section provided with mattress,Dimesnsion should be 1830 x 485 x 767 mm,Trendelburg's position 30vdeg reverse Trendelburg's position 30vdeg ,Lateral tilting position 20 deg either side and lifting position should be 225mm,flex position 90 degree,reflex position 220 degree& Head movement 20 degree up and 90 degree down.
MINOR OT
Antibacterial / Antifungal Paint Providing and applying Antibacterial Paint: The internal surfaces of the room.walls will be sprayed with water based liquid plastic, wall glaze or equivalent anti-bacterial paint, approved by the architect to a minimum dry film thickness of 300 microns. The plastic coating will overlap the floor covering ceiling system and doorframes by 25mm to provide a continuous sealed surface. The plastic coating will be non- reflective and the Colour will be submitted to the architect for approval.
Dimmable Peripheral Lights Peripheral Lights non hygroscopic peripheral lights peripheral lights for clean room application, low power consumption with dimmer control (suitable for clean room application). The luminaries to be provided in such a way to achieve light intensity of 350 Lux at 1m from floor. Dimmable Peripheral Lights will be CE certified and in compliance under Class 1 Medical devices
Storage Unit Storage Unit of size (1050 x 2100 x 350) .The storage unit cabinet will be finsihed in Powder coat .The unit will be divided into 2 equal parts and each part will have individual glass doors with locking system .Each part will have racks to keep surgical medicines etc.Storage Unit will be CE certified and in compliance under Class 1 Medical devices
Single Arm Moveable Pendant - CE Marked Single Arm Pendant will have 1000mm arms with Horizontal movement having load carrying capacity of 100kgs. The Single arm will be rotated upto 330degree to 340 degree . Pendant will have 1 arms with two shelves as per points : 1) 5/15 Amp Electrical sockets without switches - 8 to 10 nos., 2) shelfs with side rails - 2 nos. 3) Provision to fix 3 Nos Gas Outlets.
X-Ray View Screen X-ray view box:- Twin Plate X-Ray viewing screen with flicker free dimming light range from 15 to 100% with complete accessories as required to view the X-ray film.
OT Table Universal General Purpose Operating table having five section top,perineal cut,detechuing leg section provided with mattress,Dimesnsion should be 1830 x 485 x 767 mm,Trendelburg's position 30vdeg reverse Trendelburg's position 30vdeg ,Lateral tilting position 20 deg either side and lifting position should be 225mm,flex position 90 degree,reflex position 220 degree& Head movement 20 degree up and 90 degree down.
SIGNAGE WORK
Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. 10Feet by 3 Feet
Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. 9 Feet by 2 Feet
Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. 4 Feet by 3 Feet
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 2 Feet
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 2 Feet
Laser Cut 5 mm Acrylic Letters with Pasted over 5 mm Acrylic Sheet with 6 studs .4 Feet by 3 Feet
Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back.4 Inch18 Inch by
Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back.4 Inch18 Inch by
Aluminum Flat Plain Profile with Sliding Acrylic 3 mm for changeable doctors name (Min. 3 Doctors Name Plate).12 Inch by 4 Inch
3 mm Acrylic with Desired Color with Plotter Cut Vinyl Letters.6 Inch by 3 Inch
5 mm Acrylic with Desired Color with Plotter Cut Vinyl Letters.2 Feet by 1 Feet
Audio & Video work
Supply, laying, testing and commissioning of with power and control cabling as per specification all completed as per direction engineer in charge.
42" LED Display
Display Manager with Splitter
Application - (Customized)
HDMI Extender
HDMI Cable Set
Installation & Configuration
HOSPITAL FURNITURE
NICU BED Plastic/ABS Head NICU BED Size of 830 L x 600 W x 600 H Pre trated and Epoxy Powder Coated,Manually Operated four function bed featuring,Trendelenburg's reverse with Hi-Lo postion Frame & Plateform should be made of CRCA steel with IV Rod and Split Rolling Function,Castor should be 125mm
FOWLERS BED Plastic/ABS Bed Head Panels Size of 2030 L x 900 W x 600 H Pre trated and Epoxy Powder Coated,Manually Crank Operated with Hi-Lo postion Frame & Plateform should be made of CRCA steel with100 mm Swivel castor
LABOUR TABLE Size of 2030 L x 900 W x 600 H Pre trated and Epoxy Powder Coated,CRCA Steel Tube Frame,SS Three section top,Leg section should be slides completely under the trunk section.Labour table should be Adjustable back on rachect ,padded Lithotomic cructhes mattress,hand grips on either side.
BED SIDE LOCKER Single Storgage box,Size of 400 L x 400 Wx 800 mm H epoxy powder coated ,Frame should be CRCA Sheet/Tube closed on threeside with SS top,having two PVC shpe and two 50 mm castors.
OVER BED TABLE Frame made of CRCA steel tube with epoxy powder coated,laminated wooden board with adjustable gear.Dimension of top : 750 L x 400 w mm ,Table stand on 50 mm castors.
SS STOOL Pre treted epoxy powder coated SS revolving stool made of CRCA steel tube with four leg height adjustable upto 675mm,reinforced with steel frame.Foot rest ring on PVC shoes.
IV STAND Made of CRCA tube ,pre tyreted epoxy powder coatedwith plastic 5b progned base.SS rod with double hook with height adjustable knob upto 2025mm approx on 50mm castors.
Add 18% GST
Add 1% Labour cess 1%
ANAND CONSTRUCTION INFRASTRUCTURE PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .