Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹43.1 L+₹2.4 L (6.01%)Rejected-Finance NIL | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹43.4 L+₹2.8 L (6.87%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹44.1 L+₹3.4 L (8.47%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹44.1 L+₹3.5 L (8.54%)Rejected-Finance PO BANARHAT DIST JALPAIGURI W B PIN 735202 | BANARHAT | JALPAIGURI | WEST BENGAL | 735202 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Jun 2021, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR/MAINTENANCE/ REPLACEMENT OF EXISTING ELECTRIC WORN OUT WIRING/FIXTURES LED FITTINGS WINDOW/SPLIT TYPE AC REFERIGERATORS DEEP FREEZERS WATER COOLERS FOR D ZONE MD ACCN AND CERTAIN OUTSIDE UNITS UNDER AGE E/M AT GE BENGDUBI MIL STN
2021_MES_447611_1
GE/BENG/12 OF 2021-22
Open Tender
Electrical and Maintenance Works
Works
180 days
BENGDUBI
MES Enlisted/ Un-enlisted contractor of D and above with category b(i) and c(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹80,000
Yes
6 Jul 2021
2 Jun 2021
23 Jun 2021
2 Jun 2021
21 Jun 2021
16 Jun 2021
4 Jun 2021 - 9 Jun 2021
Amount
SCHEDULE 'A'
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site complete all as specified and directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
M&L for concealed point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface for the following: -
One light point or one light point/fan point/ calling bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
M&L for concealed point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent complete all as specified and directed.
M&L for concealed point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 4 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 4 sqmm size through and including 25 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one AC/Gyser sockets outlet independent complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc for the following: -
One light point or one fan point /lightpoint/ bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
M&L for point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 4 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 4 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one AC/Gyser sockets outlet independent complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
Fixing only Switch piano any type (as retrived against item No 2.00 here-in-before) complete all as specified and directed.
S&F Switch socket combination 5 pin, 2 in 1, 5 Amp flush type complete all as specified and directed.
Fixing only Switch socket combination 5 pin, 2 in 1, 5 Amp flush type (as retrived against item No 2.00 here-in-before) complete all as specified and directed.
S&F Switch socket combination multipurpose 3 pin 16A and one 3 pin 6Amp 5 in 1 flush type complete all as specified and directed.
Fixing only Switch socket combination 5A/ 16A, 5 in 1 flush type (as retrived against item No 2.00 here-in-before) complete all as specified and directed.
Supply and fixing including connection call bell AC 230 volts, single pole, Make : ANCHOR/CONA/BAJAJ/.
Supply and fixing including connection of bell push button type 5 Amps, Make : ANCHOR/BAJAJ/CONA
S&F Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
Fixing only Ceiling rose any type (as retrived against item Ser No 2.00 here-in-before)
S&F ceiling fan regulator electronic stepping type and socket size, SP 230 Volts, suitable for 1200 mm/1400 mm sweep ceiling fan including necessary electric connection complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings including 8 Watt LED bulb all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with double pole MCB of 20 amps all as directed and specified
S&F three pole and neutral enclosure with a three pin and earth plug and socket complete with TPN MCB of 63 amps all as directed and specified
S&F LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete all as specified and directed . Make Havells cat part no. LUMILINEBS18WLED865SPWH OR EQUIVALENT MODEL OF CG /Philips.
S & F CFL light fitting,1x10W LED bulk head luminaries IP65, complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V,50HZ. make:Havells cat part no.RUGBYGENX10W or equivalent model of Philips/CG
S & F LED Tube Light luminaries with high performance LED with driver 1 x 9W (2 Feet long, Cool day/Warm white) complete all as specified and directed .make:Havells CAT PART NO.LUMILINEBS9WLED865SPCWH or equivalent model of Philips/CG
S&F 36W LED Square Type 2' x2' recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed by Engr-in-Charge.Make:crompton cat part no.LCTLRN-36-FO-CDL or Equivalent model ofPhilips/havells.
S&F 12W LED Round/Square recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed by Engr-in-Charge.make:Havells cat part GLOW DL SUR RD 12W or Equivalent model of Philips/CG
S&F Building security LED light luminaire fitting 1X20 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clam made out of MS flat of size 25X3 mm , 4 nos Anchor Bolt of suitable size etc all as specified and as directed by the Engineer-in-charge . MAKE Havells cat part no. VILUMINA 20W or equivalent model of Philips/CG.
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site complete all as specified and directed.
S&F sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Tripple pole and neutral (TPN) 415 Volt , double door, suitable for 4 way with dim rail earth and neutral bar all as specified and directed. Make - Legrand/ Havells/C&S or equivalent.
S&F sheet metal enclosure double door for DB'S 12 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes all as specified and directed.
S&F sheet metal enclosure double door for DB'S 8 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes all as specified and directed.
S&F sheet metal enclosure double door for DB'S 4 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes all as specified and directed.
S&F sheet metal enclosure double door for DB'S 2 Way when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar complete of following sizes all as specified and directed.
Supply and fixing in proper position MCB TPN 63 AMP capacity , 415 Volts with 10 kA breaking capacity all as specified and as directed.
S&F MCB Single pole and neutral 240 Volt 20 to 40 Amp capacity complete all as specified and directed.
S&F MCB Single pole 240 Volt 6 to 32 Amp capacity complete all as specified and directed.
Taking down carefully existing unserviceable tube light / LED light fitting of any watt from existing location to carry out the necessary repair like replacement of bipin holder, tubes etc and fixed to original location after made functional including necessary electric connections with 3 core flexible cable of size 23/0.0076 mm complete all as specified and directed. (Materials shall be measured and paid seperately under relevent item of Sch 'A'/BoQ)
Supply Bipin holder for 18/36/40 W tube light
Supply only of LED single tube 1 X 20 Watts,(4 Ft) 240 V Ultra bright LED polycarbonate Tubelight with very high efficacy suited for installation in existing T8 tubelight with G13 lamp holders to give glare free light (Make Havells/ Bajaj/CG/Phillips)
S&F LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete all as specified and directed . Make Havells cat part no. LUMILINEBS18WLED865SPWH OR EQUIVALENT MODEL OF CG /Philips.
S & F LED Tube Light luminaries with high performance LED with driver 1 x 9W (2 Feet long, Cool day/Warm white) complete all as specified and directed. (Make: Havells CAT PART NO.LUMILINEBS9WLED865SPCWH or equivalent model of Philips/CG)
S&F 36W LED Square Type 2' x2' recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed (Make:crompton cat part no. LCTLRN-36-FO-CDL or Equivalent model of Philips/havells).
S&F 36W LED Square Type 2' x2' surface mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed. (Make: Havells cat part no. PLANO SURFACE 2 X2 36W or Equivalent model of Philips/CG.
S&F LED post top light 30/40 Watt as suitable including all accessories as specified and directed. (Make: havells cat part no. RUBYPT25WLED830SSYMTOPC or equivalent model of philips/CG)
S&F Building security LED light luminaires fitting 1X20 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut, washer, clamp made out of MS flat of size 25X3 mm, 4 nos Anchor Bolt of suitable size etc all as specified and directed. (MAKE Havells cat part no. VILUMINA 20W or equivalent model of Philips/CG).
S&F in replacement Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S&F in replacement Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S&F in replacement Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement Modular Regulator Step Type 120 watt, 2 module complete all as specified and directed.
S&F in replacement Modular Blank plate, 1 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 2 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 3 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 4 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 6 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 2 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 3 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 4 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 6 module complete all as specified and directed.
S&F in replacement MS Box in concealed of any type and any size complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 250 x 200 x 3 mm complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 250 x 150 x 3 mm complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 100 x 100 x 3 mm complete all as specified and directed.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 175 x 100 x 50 mm deep.
S&F in replacement MCB Four pole, 415 volts, 40-63 Amps, breaking capacity 10KA Cat No 408700-02, make: Legrand or equivalent model of L&T, C&S, Indoasian
S&F in replacement MCB 'C' series Double pole 40 to 63 Amps, breaking capacity 10KA, Cat No 408637-39, make: Legrand or equivalent model of L&T, C&S, Indoasian
S&F in replacement MCB 'C' series Double pole 6 to 32 Amps, breaking capacity 10KA, Cat No 408628-36, make: Legrand or equivalent model of L&T, C&S, Indoasian
S&F in replacement MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA, Cat No 408587-95, make: Legrand or equivalent model of L&T, C&S, Indoasian
Taking out old U/S underground LT Service wire of any size, any position from trenches, floors and walls, all as specified and directed.
S&F 4 Sqmm 1100 Volts grade heavy duty cable PVC insulated multi stranded aluminium conductor of following size served with inner seathing of PVC tape and over all PVC seathed for service conection suspended by insulating hangers not more then 01 Mtr apart including 4mm dia suspension wire and twin core cable flate or circular including taking down complete as directed and specified. Make of Cable: Richa/Harsh/Finolex/RR Cable
All items as per Ser No 81 above but 6 Sqmm
All items as per Ser No 81 above but 10 Sqmm
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and directed.
Taking out Old un-serviceable / faulty cable of any size from trench / pole complete all as specified and directed.
M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm 2core laid in trench/pole/on wall completer all as specified and directed. Make:polycab/finolex/Havells.
M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed. Make:polycab/finolex/Havells.
M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 16 Sqmm 4 core laid in trench/pole/on wall completer all as specified and directed. Make:polycab/finolex/Havells.
Taking down unservisible items/Fixtures (i.e. switch, socket, ceiling rose, holder , bell, regulator, plug top etc) form existing board / location and supply and fixed same position incl electrical connection complete all as directed. (Note : Fixtures shall be measured and paid seperately supply only under relevent item of Sch 'A'/BoQ
Supply only Switch piano 5 amp flush type as specified and directed.
Supply only Switch piano 15 amp flush type as specified and directed.
Supply only Socket outlet 5 amp 5/6 pin as specified and directed.
Supply only Socket outlet 15 amp 5/6 pin as specified and directed.
Supply only Switch socket combination 6 Amp 6 pin flush type as specified and directed.
Supply only Switch socket combination 16 Amp 6 pin universal type as specified and directed.
Supply only Switch socket combination with box 6 Amp 6 pin flush type as specified and directed.
Supply only Switch socket combination with box 16 Amp 6 pin universal type as specified and directed.
Supply only Ceiling fan capcitor 2.5 Mfd for 1200 mm/1400 mm sweep ceiling fan
Supply only Ceiling fan regulator electronic stepping type, SP 230 Volts, suitable for 1200 mm/1400 mm sweep ceiling fan
Supply only PVC angular holder polycarbonate as specified and directed.
Supply only Call bell ding dong type 230/240 volt AC as specified and directed.
Supply only Plug top of 15 amps 3 pin as specified and directed
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia (THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Back Fill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC (1:2:4 Type B1) cover of size 450mm x 450 mm complete including excavation eartwork etc all as specified and directed make ASHLOK / INDELEC / JMV / TERCEL.
Dismantling of defective deep freezer of any capacity, size and type for thorough checking/ including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components and testing including transportation to whorkshop and back complete all as specified and directed (NOTE :- New accessories / components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, labour charges for fixing shall be included in the quoted rate)
Supply only relay for deep freezer of any size/capacity.
Supply only overload relay for deep freezer of any size/capacity.
Supply only Starting capacitor 60/40 Mfd.
Supply only Running capacitor 6/15 Mfd.
Supply only Thermostate for deep freezer.
Supply only Condenser fan motor 240 volt.
Supply only deep freezer compressor and testing the performance all as specified and directed for storage capacity of 300/400/500 ltrs deep fridge (Cat Part No. L-415) (Recharging of gas will be measured and paid separately).
Dismantling all electrical connection and taking out indoor/outdoor unit of split AC after disconnect suction & liquid line and repair cleaning, servicing and overhauling of the same including Air filter, blower motor (indoor/outdoor) and adjusting of remote control and checking all electrical devices including fixing cable socket/ gland etc and reassembling and fixing in position and leakage check the unit, charging refrigerant gas as required in the system complete all as directed. (Note:- (i) (NOTE :- New accessories / components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, labour charges for fixing shall be included in the quoted rate) (ii) Contractor shall attend any type of complaint as and when required and no extra payment shall be allowed)
Supply Only Running capacitor 40/50 mfd 4/6/8 pole 440 volt, AC including necessary copper wire. (Make : Sarda or Equivalent)
Supply Only Starting capacitor 100/120 mfd 230 volt 50 Hz including necessary copper wire (Make - Sarda or Equivalent).
Supply OnlyStarting capacitor 80 mfd 230 volt 50 Hz including necessary copper wire (Make - Sarda or Equivalent).
Supply OnlyAC contactor relay for split AC any make.
Supply Only Starting relay for 1.5/2.00 TR split AC (Make - Arvind or Equivalent).
Supply Only Copper pipe 1/2" for liquid line including fittings
Supply Only Copper pipe 5/8" for suction line including fittings
Supply Only PVC Fan blade suitable for outdoor condenser unit including necessary brass nut bolt etc.
Supply Only PVC drain pipe 25 mm dia suitable for spilt AC with necessary saddle screws complete.
Supply Only Outdoor unit condensor coil for Split AC 1.5 TR
Supply Only Outdoor unit condensor coil for Split AC 2.0 TR
Supply Only Air filter for Split AC of any size and make
Supply Only Indoor unit cooling coil for Split AC 1.5 TR
Supply Only Indoor unit cooling coil for Split AC 2.0 TR
Taking down old u/s remote control assembly and dismantling the unit and replaced the unserviceable item such as PCB, transformer and magnetic coil suitable for split AC and reassembling the same including testing complete all as directed.
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR and supply and install new compressor 2 TR 230 V, 50 Hz suitable for split AC including recharging of gas (M-22), mounting pad nut and bolt and reassembling all the connection in its original location and testing complete all as directed. (Make - Carrier/ Kirloskar/ Emerson).
Ditto all as per item No. 129 here - in - before but 1.5 TR capacity.
Dismantling all electrical connection from the blower motor and taking out unserviceable burnt blower motor and supply and install blower motor suitable for 2/1.5 TR split AC and reassembling all the connection in its original location and testing complete all as directed.
All as per item No. 27 here-in-before but condenser fan motor 2/1.5 TR split AC.
Supply and fixing remote control asy with control circuit or connected wire suitable for 2 TR/1.5 TR split type AC complete all as directed.
S&F swing motor (Synchronous motor) AC 220 Volt, 50/60 Hz for split type AC including necessary connection wire after taking out old one complete all as specified and directed.
S&F factory made split AC stand complete with fixing in wall with hinges, nuts and bolts complete all as directed.
S&F PCB board suitable for 1.5 /2 TR split AC/window AC complete all as directed.
S&F insulation tube for suction / liquid line complete all as directed.
Supply and charging Gas M-22 or equivalent to Split AC/Window type AC machine/Water Cooler including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Dismantling and opening voltage stabiliser 5/4/3KVA capacity single phase, 240 volts and replacement of old unserviceable worn out/defective parts and reassembling the same after necessary repair, cleaning servicing and testing on completion for its satisfactory performance all as specified and directed (Make - Raditror/ Emcon/ V-Guard/ Microtek/ Sen & Pandit or as specified). (NOTE :- New accessories / components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, labour charges for fixing shall be included in the quoted rate)
Ditto all as per item No. 139 here-in-before but 2/1/.05KVA capacity.
Supply only main transformer suitable for automatic line voltage corrector 5/4/3 KVA, 230 volts, 50 Hz complete all as specified and directed.
Ditto all as per item No. 141 here-in-above but 2/1/0.5 KVA capacity.
Supply only relay (time limit) suitable for automatic line voltage corrector of capacity 0.5 to 1 KVA all as specified and directed.
Supply only voltage regulating circuit board (PCB) of suitable size/ type including all necessary electrical components for operating the main transformer for output voltage 200 volts to 230 volts (2% tolerance) including all electrical connection complete all as specifed and directed.
Supply only voltage regulating transformer of voltage rating 220/12 volts to 6 volts bridge type or central type transformer of current carrying capacity 600 mA per second, any size to separate the regulating circuit board.
Supply only relay over load for stabilizer any type.
Dismantling of defective refrigerator of any make and capacity for thorough checking of all accessories and components, repairs and reassembling the same after repair/ replacement of defective accessories/components and testing complete all as directed by Engr-in-charge including transportation to workshop and back. (NOTE :- (i) New accessories / components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, labour charges for fixing shall be included in the unit rate. (ii) Repair of body overhauling / repair sealeds unit (compressor ) gas charging painting etc shall be measured and paid separately. (iii) Old serviceable accessories / components obtained shall be refixed as directed by the Engineer-in-charge and labour charge for refixing to be deemed to be included in unit rate quoted.
Supply only Cooling chamber including cooling coil of size shape suitable for refrigerator of size and of capacity upto 165/175/185/190/205/250 ltrs.
Ditto all as per item No. 148 here-in-before for refrigerator of capacity 260/280/290/310/315/345 ltrs.
Supply only Thermostat defrost type switch suitable for refrigerator of capacity upto 345 ltrs (Make - Whirlpool/ Godrej/ Annapurna).
Supply only Condensor coil of suitable for size of refrigeration capacity 165/175/185/190/205/250 ltrs .
Supply only Condensor coil of suitable for size of refrigeration capacity 260/280/290/310/315/345 ltrs .
Supply only Magnetic door gasket including fixing accessories for refrigerator of any apacity.( As per samples)
Supply only Capillary tube of size 0.31 for any type/size refrigerator
Supply only Door switch for refrigerator of any capacity.
Supply only Lamp holder, screwed/pin type including 15 watt, lamp 240 volts.
Supply only LED lamp for any capacity
Supply only wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
Supply only Running capacitor 6 / 10 mfd
Supply only Frost free fan motor SP 230 volts
Supply only Heating coil including fixing accessories suitable for 250/286/310/345 ltrs
Supply only gas R-134
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing compressor and testing the performance all as specified and directed by Engr-in-Charge for Regrigerator of Capaicty 165/200 Ltrs (Re Charging of gas will be measured and paid separetely)
Ditto all as per item No 59 here-in-above but for compressor of capacity of refrigerator 250/286/310 ltrs.
Vaccuming dehydration leak testing of the system as per system standard practice testing for proper cooling effected and satisfactory performance complete all as specified and as directed for refrigerator of capacity 165/175/185/190/205/250 Ltr
Ditto all as per item No. 61 here-in-before but for refrigerator of capacity 250/286/310/345 Ltr
S&F PCB board suitable for refrigerator to control temp/conversion in system of capacity 165/280/310 ltrs as per sample complete all as specified and directed.
Dismantling of defective water cooler storage type 40/40, 40/80, 60/120, 80/80 ltrs capacity for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components and testing complete all as specified and directed by the Engr-in-Charge including transportation to whorkshop and back complete. NOTE : (i) New accessories/ components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, labour charges for fixing are deemed to be included in the quoted unit rate (ii) Repair of body overhauling/repair, sealed compressor unit gas charging, painting etc shall be measured and paid separately.
Ditto all as per item No. 64.00 here-in-before but for water cooler storage type 120/120, 150/150, 150/180 ltrs capacity.
Supply only Condensor coil for water cooler 40/40, 40/80, 60/120, 80/80 ltrs capacity of similar specification as of old one (Make:- Shreeram/ USHA/ BLUE STAR/Voltas)
Ditto all as per item No. 66.00 here-in-before but water cooler of capacity 120/120, 150/150, 150/180 ltrs (Make:- Shreeram/ USHA/ BLUE STAR/Voltas)
Supply only Aluminium fan blade for blower motor for water cooler of capacity 40/80/120/150 ltrs (storage capacity) (Make:- Shreeram/ USHA/ BLUE STAR/Voltas)
Supply only Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs (cooling capacity). (Make:- Shreeram/ USHA/ BLUE STAR/Voltas)
Supply only Thermostat including plastic regulating knob for water cooler of capacity (cooling) 40/80/120/150 ltrs. (Make:- Shreeram/ USHA/ BLUE STAR/Voltas)
Supply only New compressor and testing the performance all as specified and directed. SRA-100/SRA-200 SF, 40/40, 40/80, 60/120, 80/80 ltr/hrs suitable for storage capacity. (Recharging of gas will be measured and paid separately).
Ditto all as per item No. 82.00 here-in-above but for compressor of water cooler of sotrage acapacity of 120/120, 150/150, 150/180 ltrs.
Vacumming, dehydration leak testing for the system as per standard practice, testing for proper cooling effect and satisfactory performance for water cooler of any capacity complete all as specified and as directed (Note :Refrigerant gas (R-134/M-22) will be measured and paid separately).
Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make/any type
M&L for cutting through brick wall built in cement mortar for provision of window type AC any size /capacity and making good with cement mortar 1:4 including three coat of white washing on new plastered surface wall including preparation of surface all as specified and as directed.
S&F outdoor unit of split AC 2.0 TR complete with all accessories (such as compressor, wiring, copper pipes) incl fixing on wall/floor complete. Make Samsung/LG/Whirlpool/Camipro. (Note :- Charging of gas shall be measured paid separately)
Ditto all as per item No. 87.00 but 1.5 TR.Make Samsung/LG/Whirlpool/Camipro. (Note :- Charging of gas shall measured and be paid separately)
S&F indoor unit of split AC 2.0 TR complete with necessary accessories (such as cabinet, wiring, copper pipes, remote control, swing motor) incl fixing on wall/floor complete. Make Samsung / LG / Whirlpool / Camipro. (Note :- Charging of gas shall be measured and paid separately)
Ditto all as per item No. 89.00 but 1.5 TR. Make Samsung / LG / Whirlpool / Camipro. (Note :- Charging of gas shall be measured and paid separately)
Dismantling of defective window type room air conditioner of any make and capacity for thorough checking repair of all accessories and components and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed. Note : (i) New accessories / components required shall be measured and paid separately under relevant items of Sch 'A'/BoQ, Labour charges for fixing shall be included in the unit rate. (ii) Repair of body, overhauling/repair sealed unit (compressor), gas charging, painting etc shall be measured and paid separately. (iii) Old serviceable accessories/ components obtained shall be refixed as directed by Engineer-in-charge. Labour charges for refixing to be deemed to be included in the unit quoted rate.
Supply only the following accssories/components suitable for window type air conditioner
Supply only Cooling coil assembly with copper tubes of specification similar to old one (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star)
Supply only Aluminium/PVC blade for blower motor for window type air conditioner (1.5/2 TR capacity) (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star)
Supply only Air filter of PVC suitable for AC (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star)
Supply only Aluminium runner suitable for AC (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star)
Supply only Thermostat with regulator knob (Make Infoss/Annapurna) for AC (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star)
Supply only Relay type 1622 suitable for window type air conditioner (1.5 TR/ 2TR capacity) Make - Shreeram/ Annapurna)
Supply only over load protector type DC 1622 surge voltage 250 volts RNQ suitable for window type air conditioner (1.5 TR / 2 TR capacity) Make - Shreeram).
Supply only PVC front grill suitable for window type room AC of any make any type (as per sample).
Supply only Swing motor for window type AC 1.5 ton capacity.
Supply only Wiring set complete suitable for AC.
Supply only Relay 4 pole switch for AC/refrigerator.
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR and supply and install new compessor 2 TR 230 V, 50 Hz suitable for window AC including charging of gas (M-22), mounting pad nut and bolt and reassembling all the connection in its original location and testing complete (Make - Carrier/ Kirloskar/ Emerson).
Ditto all as per item No. 105.00 here-in-above for compressor of capacity 1.5 TR.
M&L for attending,repair and rectification of any type of complaint of Window AC / Split AC / Refrigerator/ Water Cooler alongwith necessary T&P complete all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 75,012.00 (refer Tender Srl Page No 53). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
SHRI PRADEEP PARIK
SARKAR ENGINEERING CO.
BEEPEE AND COMPANY
SHRI SANJAY KUMAR GUPTA
KD SAHA and CO.INDIA
ANIL KUMAR GUPTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .