Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹10.7 CrAccepted-AOC HAIBORGAON CITY TOWN NAGAON P O HAIBORGAON P S NAGAON PIN 782002 DISTRICT NAGAON ASSAM | NAGAON | ASSAM | 782002 | ₹10.7 Cr | L2 | Accepted-AOC Work Order Issued |
| 2 | L1₹10.7 CrRejected-AOC | ₹10.7 Cr | L1 | Rejected-AOC L1 |
| 3 | L3₹11.9 CrRejected-AOC NAGAON ASSAM | BONGAIGAON | ASSAM | 783371 | ₹11.9 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹11.9 Cr
EMD Value
₹23.8 L
Closing Date
30 Oct 2023, 2:00 pmClosed
CE, PWD (Roads), Assam, Chandmari, Guwahati-3
O/O The CE, PWD (Roads), Assam, Chandmari, Ghy-3
Package No. RIDF-XXIX/Morigaon/01 Const of (i) RCC Br. No.47/1 A on Nagaon Bhuragaon Road (ii) RCC Br. No. 1/1 on Tengaguri Falihamari Road (iii) RCC Br. No. 2/2 on Barashibandha Dikhoumukh Road (iv) RCC Br. No. 3/1 on Autolabori to Chetuakhaity Road
2023_PWD_32932_7
CE/STBR/RIDF XXIX/NIT/23/23-24/2 Dtd 30-09-2023
Open Tender
Civil Works – Roads
730 days
Morigaon
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
₹23.8 L
Yes
30 Mar 2024
10 Oct 2023
1 Nov 2023
10 Oct 2023
30 Oct 2023
10 Oct 2023
10 Oct 2023 - 30 Oct 2023
Amount
Construction of (i) RCC Br. No.47/1 A on Nagaon Bhuragaon Road. Labour for dismanteling all members of the timber bridge (except piles) and stacking them at sutiable places as directed( all members will be under custody of the contractor till taken over by th department.)scarfing and joining piles 25 cm to 30 cm dia Dressed to heartwood 90 cm. In length includng supplying, fitting and fixing with 2 nos. of 50 mmX 10 mm MS FI clamps and 16 mm dia MS bolts and nuts etc. complete as directed
Labour for taking out old piles of the bidge and stacking them at suitable place as directed
Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work.
Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification.
Providing and constructing one span service road to reach island location from one pier location to another pier location
Carrying out Sub Soil Investigation (SSI) for all types of soil (except boring in rock) upto a depth of 30m or refusal (N-100) for each foundation location as per IRC:78-2000 and submission of SSI report to the engineer in charge for approval. Preparation & submission of Design calculation & Drawings of foundations, sub Structure , Super Structure as per relevent IRC Codes and SSI report 2 (Two) Copies each of Design & drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competant authority.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (A) Manual Means (i)In ordinary soil (I) Without dewatering (I)Up to 3 m depth.
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test in single vertical pile in accordance with I.S.2911(Part-IV) a) Initial & Routine Load Test
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. 1100,1500 & 1700. B) RCC grade M-25 (i) Using concrete mixure.
Levelling course for Pile cap
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (A) With Crushed Stone. Iv)RCC grade M-25 (i) Height upto 5.0 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (ii) Sandy materials
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without Plasticiser (B) RCC Grade M25, (Case-I): Using Concrete Mixer (II) For T-beam & Slab. (a) Height upto 5.0 M
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a)TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying cement concrete wearing coat M-30 grade including reinfor-cement complete as per drawing and technical specification clause 800 & 1206.3. (B) With crushed stone.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage spouts complete as per approved drawing and technical specification clause 1209.
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification, (A) With crushed stone (ii) TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means (a) In area of non thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p gto meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i)Private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (ii) For Grading II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) (II) Grading- II Using Screening Crushable type such as Moorum or Gravel
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) III. Grading-III, Using Screening Crushable type such as Moorum or Gravel
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I: By Manual Means (i) Bitumen (S-90)
Case - III : Type C: Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 (A) By Manual Means, Case - I : Type A (i) Bitumen (S-90)
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing not less than 25 kg, laid dry complete as per drawing and Technical Specification Clause 1301
Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and Technical Specification Clause 1302 I. Stone/Boulder
Construction of (ii) RCC Br. No. 1/1 on Tengaguri Falihamari Road. Labour for dismanteling all members of the timber bridge (except piles) and stacking them at sutiable places as directed( all members will be under custody of the contractor till taken over by th department.)scarfing and joining piles 25 cm to 30 cm dia Dressed to heartwood 90 cm. In length includng supplying, fitting and fixing with 2 nos. of 50 mmX 10 mm MS FI clamps and 16 mm dia MS bolts and nuts etc. complete as directed
Labour for taking out old piles of the bidge and stacking them at suitable place as directed
Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work.
Carrying out Sub Soil Investigation (SSI) for all types of soil (except boring in rock) upto a depth of 30m or refusal (N-100) for each foundation location as per IRC:78-2000 and submission of SSI report to the engineer in charge for approval. Preparation & submission of Design calculation & Drawings of foundations, sub Structure , Super Structure as per relevent IRC Codes and SSI report 2 (Two) Copies each of Design & drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competant authority.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (A) Manual Means (i)In ordinary soil (I) Without dewatering (I)Up to 3 m depth.
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test in single vertical pile in accordance with I.S.2911(Part-IV) a) Initial & Routine Load Test
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. 1100,1500 & 1700. B) RCC grade M-25 (i) Using concrete mixure.
Levelling course for Pile cap
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (A) With Crushed Stone. Iv)RCC grade M-25 (i) Height upto 5.0 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (ii) Sandy materials
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without Plasticiser (B) RCC Grade M25, (Case-I): Using Concrete Mixer (II) For T-beam & Slab. (a) Height upto 5.0 M
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a)TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying cement concrete wearing coat M-30 grade including reinfor-cement complete as per drawing and technical specification clause 800 & 1206.3. (B) With crushed stone.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage spouts complete as per approved drawing and technical specification clause 1209.
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification, (A) With crushed stone (ii) TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means (a) In area of non thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p gto meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i)Private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (ii) For Grading II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) (II) Grading- II Using Screening Crushable type such as Moorum or Gravel
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) III. Grading-III, Using Screening Crushable type such as Moorum or Gravel
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I: By Manual Means (i) Bitumen (S-90)
Case - III : Type C: Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 (A) By Manual Means, Case - I : Type A (i) Bitumen (S-90)
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing not less than 25 kg, laid dry complete as per drawing and Technical Specification Clause 1301
Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and Technical Specification Clause 1302 I. Stone/Boulder
Construction of (iii) RCC Br. No. 2/2 on Barashibandha Dikhoumukh Road Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work.
Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification.
Providing and constructing one span service road to reach island location from one pier location to another pier location
Carrying out Sub Soil Investigation (SSI) for all types of soil (except boring in rock) upto a depth of 30m or refusal (N-100) for each foundation location as per IRC:78-2000 and submission of SSI report to the engineer in charge for approval. Preparation & submission of Design calculation & Drawings of foundations, sub Structure , Super Structure as per relevent IRC Codes and SSI report 2 (Two) Copies each of Design & drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competant authority.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (A) Manual Means (i)In ordinary soil (I) Without dewatering (I)Up to 3 m depth.
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test in single vertical pile in accordance with I.S.2911(Part-IV) a) Initial & Routine Load Test
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. 1100,1500 & 1700. B) RCC grade M-25 (i) Using concrete mixure.
Levelling course for Pile cap
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (A) With Crushed Stone. Iv)RCC grade M-25 (i) Height upto 5.0 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (ii) Sandy materials
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without Plasticiser (B) RCC Grade M25, (Case-I): Using Concrete Mixer (II) For T-beam & Slab. (a) Height upto 5.0 M
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a)TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying cement concrete wearing coat M-30 grade including reinfor-cement complete as per drawing and technical specification clause 800 & 1206.3. (B) With crushed stone.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage spouts complete as per approved drawing and technical specification clause 1209.
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification, (A) With crushed stone (ii) TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means (a) In area of non thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p gto meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i)Private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (ii) For Grading II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) (II) Grading- II Using Screening Crushable type such as Moorum or Gravel
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) III. Grading-III, Using Screening Crushable type such as Moorum or Gravel
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I: By Manual Means (i) Bitumen (S-90)
Case - III : Type C: Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 (A) By Manual Means, Case - I : Type A (i) Bitumen (S-90)
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing not less than 25 kg, laid dry complete as per drawing and Technical Specification Clause 1301
Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and Technical Specification Clause 1302 I. Stone/Boulder
Construction of (iv) RCC Br. No. 3/1 on Autolabori to Chetuakhaity Road Labour for dismanteling all members of the timber bridge (except piles) and stacking them at sutiable places as directed( all members will be under custody of the contractor till taken over by th department.)scarfing and joining piles 25 cm to 30 cm dia Dressed to heartwood 90 cm. In length includng supplying, fitting and fixing with 2 nos. of 50 mmX 10 mm MS FI clamps and 16 mm dia MS bolts and nuts etc. complete as directed
Labour for taking out old piles of the bidge and stacking them at suitable place as directed
Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work.
Carrying out Sub Soil Investigation (SSI) for all types of soil (except boring in rock) upto a depth of 30m or refusal (N-100) for each foundation location as per IRC:78-2000 and submission of SSI report to the engineer in charge for approval. Preparation & submission of Design calculation & Drawings of foundations, sub Structure , Super Structure as per relevent IRC Codes and SSI report 2 (Two) Copies each of Design & drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competant authority.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (A) Manual Means (i)In ordinary soil (I) Without dewatering (I)Up to 3 m depth.
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test in single vertical pile in accordance with I.S.2911(Part-IV) a) Initial & Routine Load Test
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. 1100,1500 & 1700. B) RCC grade M-25 (i) Using concrete mixure.
Levelling course for Pile cap
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (A) With Crushed Stone. Iv)RCC grade M-25 (i) Height upto 5.0 M
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (ii) Sandy materials
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (N) Without Plasticiser (B) RCC Grade M25, (Case-I): Using Concrete Mixer (II) For T-beam & Slab. (a) Height upto 5.0 M
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a)TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying cement concrete wearing coat M-30 grade including reinfor-cement complete as per drawing and technical specification clause 800 & 1206.3. (B) With crushed stone.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage spouts complete as per approved drawing and technical specification clause 1209.
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification, (A) With crushed stone (ii) TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(I) By Manual Means (a) In area of non thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p gto meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i)Private land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (ii) For Grading II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) (II) Grading- II Using Screening Crushable type such as Moorum or Gravel
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) III. Grading-III, Using Screening Crushable type such as Moorum or Gravel
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I: By Manual Means (i) Bitumen (S-90)
Case - III : Type C: Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 (A) By Manual Means, Case - I : Type A (i) Bitumen (S-90)
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing not less than 25 kg, laid dry complete as per drawing and Technical Specification Clause 1301
Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and Technical Specification Clause 1302 I. Stone/Boulder
Rishabh Jain
Ramesh Kr. Agarwalla
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid