Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹48.8 L+₹3.9 L (8.70%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹50.1 L+₹5.1 L (11.5%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹50.5 L+₹5.5 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹50.5 L+₹5.6 L (12.5%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 Jun 2023, 6:00 pmClosed
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
COMPREHENSIVE MAINTENANCE OF SEWAGE TREATMENT PLANT, REPAIR/MAINT OF EARTHING OF DBS AT VARIOUS LOCATIONS AND COMPREHENSIVE MAINT OF E/M MACHINERY AND OTHER MISC ITEMS AT AFS HASIMARA
2023_MES_595103_1
C/8664/23-24/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹90,000
Yes
30 Jun 2023
12 May 2023
23 Jun 2023
12 May 2023
19 Jun 2023
26 May 2023
Amount
M & L for disconnecting all electric and water supply connections and other related items and lifting the unserviceable non clog Submersible motor and pump of capacity 7.5HP, 3 phase, 415 V, from sewage sump by mechanical/manual method and dismantling the column pipe line, shafts stage and keeping the same in safe custody for reuse including transportation of the defective pump set and motor from pump house to workshop for repair and back and lowering and re-installation the same on exisisting position after necessary repair including testing, complete all as specified and directed.
M & L for dismantling the unserviceable parts and burnt out copper winding from pump and motor of capacity 7.5 HP, 3 phase, 415V, and rewinding the motor with supper enamelled copper wire of suitable gauge including heating, varnishing, replacement of defective spare parts, re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence at site, complete all as specified and directed. (Note:- (i) Spare/parts, copper winding wire shall be measured & paid seperately as supply only under respective item. (ii) Labour charge for fixing parts shall deemed to be included in the unit rate.)
Supply only copper winding wire with supper enamelled copper wire of suitable gauge as per capacity/rating of motor, complete all as specified and directed.
Taking down the unserviceable parts from the non clog submersible pump of capacity 7.5 HP, 3 phase, 415 V including over hauling, servicing/cleaning throughly discharge/suction cases, impellers, shaft and re-assembling pump carefully including servicing , cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repair/replacement of unservicable parts as required at site etc and re-assembling/re-installing the pump, complete all as specified and directed. (Note:- (i) Spare/parts shall be measured & paid seperately as Supply only items (i) Labour charge for fixing parts shall deemed to be included in the unit rate.)
M & L for machine work to the worn out portion of non clog submersible pump shaft of capacity 7.5 HP capacity including metalling, cutting, polishing and checking the accuracy on the lath machine, complete all as specified and directed.
Supply only ball bearing for non clog submersible motor as per existing, complete all as specified and directed.
Supply only mechanical seal for non clog submersible motor as per existing, complete all as specified and directed.
Supply only hydraulic oil for non clog submersible motor as per existing, complete all as specified and directed.
Supply only impeller as per existing, complete all as specified and directed.
Supply only impeller key as per existing, complete all as specified and directed.
Dismantling the induction motor from sewage sump/STP taking out burnt out winding wire from the stator of induction motor upto 3 HP and 1450 RPM of any make and rewinding with super enamelled copper wire of appropriate size and number of turns as per manufacturers specifications including heat varnishing and testing of 3 phase, 415/440 volt and refixing after repair, complete all as specified and directed. (Note:- (i) Copper winding wire shall be measured & paid seperately as Supply only. (ii) Labour charge for fixing parts and transport shall deemed to be included in the unit rate.)
All as per item No 11 here-in-above but for 5 HP induction motor, complete all as specified and directed.
All as per item No 11 here-in-above but for 7.5 HP induction motor, complete all as specified and directed.
All as per item No 11 here-in-above but for 10/12.5 HP induction motor, complete all as specified and directed.
Taking out vertical non-clog pump set upto 10 HP capacity from sewage sump/STP, dismantling pump complete after disconnecting all electrical connections and repair/overhauling including replacement of worn out parts, complete all as specified and directed. Note : (i) Spares required for replacement shall be measured and paid as 'Supply only' under respective items. (ii) Reassembling, lowering in sewage sump to its original place, testing and transport will be included in quoted rate.
Supply only gun metal bush of vertical non-clog pump set upto 10 HP capacity, complete all as specified and directed. Make: (Kirloskar/Bharat)
All as per item No. 16 here-in-above but impeller, complete all as specified and directed.
All as per item No. 16 here-in-above but impeller key, complete all as specified and directed.
All as per item No. 16 here-in-above but neck ring (bronze), complete all as specified and directed.
All as per item No. 16 here-in-abov but guide ring, complete all as specified and directed.
All as per item No.16 here-in-above but lock bolt for impeller , complete all as specified and directed.
All as per item No. 16 here-in-above but shaft sleeve, complete all as specified and directed.
All as per item No. 16 here-in-above but oil seal for L B H, complete all as specified and directed.
All as per item No. 16 here-in-above but oil seal for I B H, complete all as specified and directed.
All as per item No. 16 here-in-above but grease pot for ball bearing, complete all as specified and directed.
All as per item No. 16 here-in-above but shaft coupling (screwed), complete all as specified and directed.
All as per item No. 16 here-in-above but coupling pin & bush, complete all as specified and directed.
All as per item No. 16 here-in-above but ball bearing, complete all as specified and directed.
All as per item No. 16 here-in-above but engine oil, complete all as specified and directed.
All as per item No. 16 here-in-above but lock bolt for shaft coupling, complete all as specified and directed.
All as per item No. 16 here-in-above but top shaft, complete all as specified and directed.
Taking out centrifugal non-clog horizontal type pump from STP repair/overhauling/servicing of pump set by dismantling all components, re-metalling of worn out portion of shaft and grinding/polishing, replacement of bush, gland packing, gland studs, impeller key including filling of fresh lubricating oil in pedestal bearing oil chamber up to required level and greasing of bearing at non-diving end pump capacity upto 12.5 HP, complete all as specified and directed. Note : (i) Spares required for replacement shall be measured and paid as 'Supply only' under respective items. (ii) Reassembling, lowering in sewage sump to its original place , testing and transport will be included in quoted rate.
Supply only bearing ring for suction cover for horizontal pump sets capacity upto 12.5HP, complete all as specified and directed.
All as peritem No. 33 here-in-above but gasket (asbestos), complete all as specified and directed.
All as peritem No. 33 here-in-above but gland cover with stuffing box, complete all as specified and directed.
All as peritem No. 33 here-in-above but gland packing (5 Nos in one set), complete all as specified and directed.
All as peritem No. 33 here-in-above but ball bearing (N.D.E), complete all as specified and directed.
All as peritem No. 33 here-in-above but thrust bearing (D.E), complete all as specified and directed.
All as peritem No. 33 here-in-above but grease cup, complete all as specified and directed.
Supply and fix in repair rubber coupling/spider coupling, flexible type suitable for upto 10 HP pump set, complete all as specified and directed.
Supply and fix in repair DOL starter along with single phase preventor in sheet steel enclosure , 3 phase, 415 volts with contactor suitable for 1 to 6 HP electric motor, complete all as specified and directed Make : L&T model No. MK1 DOL or equivalent model of make BCH/Havells
Supply and fix in repair fully automatic (FASD) star delta starter along with single phase preventor in powder coated enclosure with PU gasket suitable upto 6 HP to 10 HP including all electric connection with ammeter and volt meter on/off & trip indicator including protection against phase failure, phase imbalance, phase reversal, complete all as specified and directed. Make : L&T model No. MK1 FASD or equivalent model of make BCH/Havells
S&F in repair cast iron sluice valve in double flanged complete with brass spindle, iron wheel handle clock wise closing with drilled hole flanged heavy duty PN 1.6 of 100mm bore including rubber gasget, nut, bolts, washers including taking down unserviceable sluice valve, complete all as specified and directed. (Make Kirloskar/Leader/Upadhyay.
All as per item No 43 here-in-before but 150mm bore, complete all as specified and directed.
M & L for repair/servicing of existing sluice valve of 100mm bore after dismantling of upper cover ,remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.
M & L for repair/servicing of existing sluice valve of 150mm bore after dismantling of upper cover ,remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.
Dismantling of any type angle iron or MS sheet, complete all as specified and directed.
Material and labour for mild steel work comprising of MS sheet, bracings, supports, clamps and back plates fabricated from structual steel sections including nuts,bolts washers,welding ,bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one coat of synthetic enamelled paint (1st grade quality), complete all as specified and directed.
Material and labour for taking out primary and secondary bio filters assembly complete for overhauling dismantling its components, replacing of gaskets, applying of grease to the steel balls, replacing of U/S steel ball, and re-assembling after completion of overhauling, complete all as specified and directed.
Supply and fix GI pipe heavy class of 100mm dia including painting with one coat of synthetic enamel paint (1st grade quality) of approved tint including preparation of surface, complete all as specified and directed.
Supply and fix GI pipe heavy class of 150mm dia including painting with one coat of synthetic enamel paint (1st grade quality) of approved tint including preparation of surface, complete all as specified and directed.
Supply and fix GI nozzle with provision of new GI nipple 40mm dia including dismantling old one, complete all as specified & directed.
Bailing out the sludge/containminated water (organic or inorganic) including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and removing the same within 50m distance and disinfecting the area with sufficient quantity of bleaching powder and including removing and refixing of manhole covers as required, complete all as specified and directed. (Note: (i) The cost of temporary barricade and providing sufficient bleaching powder shall deem to be included in the unit quoted rate (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate and nothing extra shall be paid on this account) (iii) This operation shall be carried out once in every three month every time shall be paid and measured saperately.
Taking out/bailing out the sludge/semi solid materials including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and taking out sludge/semi solid materials/any other foreign materials from septic tanks etc and removing the sludge within 50m distance and deposited in a pit to be excavated and disinfecting the area with sufficeint quantity of bleaching powder over the earth fill and covered with earth filling upto 30cm depth of pit including removing and refixing of manhole covers as required, complete all as specified and directed. (Note: (i) The cost of Excavation and earth work for pit, bamboo matting, temporary barricade of the pit and providing sufficient bleaching powder shall deem to be included in the unit quoted rate (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate and nothing extra shall be paid in this account) (iii) This operation shall be carried out once in every three month every time shall be paid and measured saperately.
S&F PVC insulated, PVC sheathed , stranded copper conductor as in flat submersible water proof cable of size 2.5 Sqmm 3 core 1100 volts grade including taking down old unserviceable cable, complete all as specified and directed.
S&F PVC insulated, PVC sheathed, stranded copper conductor as in flat submersible water proof cable of size 6 Sqmm 3 core 1100 volts grade including taking down old unserviceable cable, complete all as specified and directed.
M&L for testing and submit raw sewage water and treated water and submit the following test results:- (a) Samples to be taken from sewage pumping station Near Bala Ji Mandir, Near DSC accn, Near R S Ground, Near FWC & treated water from Main STP . (b) Submit all samples at the nearest Govt Test lab. The test for the following parameters has to be carried out:- (i) BOD (ii) COD (iii) Oil & Grease (iv) PH Value (v) TSS (vi) Feacel Colliform (vii) Residule chlorine (c) Submit the test report duly signed by appropriate Govt authority in every three month, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level,using galvanised iron strip 25×4mm as earthing lead with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 40mm dia and watering pipe medium grade of 20mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, complete all as specified and directed.
All as per item No.58 herein-above but with galvanised earth lead wire of 4.0mm dia, complete all as specified and directed.
Taking out existing boulders (75 to 200mm) complete from primary bio filter bed of dia 8.20m, depth of boulders bed 1.6m, cleaning the boulders using fresh water, cleaning bottom surface of the filter bed and re-filling the filter bed after cleaning boulders and removing the wastage/sediments out side defence land, complete all as specified and direccted.
All as per item No 60 here-in- above but from secondary bio filter of dia 10.10m and depth of boulders 1.6m, complete all as specified and directed.
Supply and lay boulders of size 75mm to 200mm in primary and secondary bio - filters, complete all as specified and directed.
Supply and fix in repair column pipe 80mm bore heavy duty both end threaded with socket, including painting with two coats of black bituminus paint over a coat of red oxide zinc chrome primer including taking down old pipe from exosting pump suction line from sewage sump, complete all as specified and directed.
S & F in repair voltmeter digital type, complete all as specified and directed.
S & F in repair ammeter digital type, complete all as specified and directed.
Supply and fix in repairs on-off push button pendants with elements red /green/orange, complete all as specified and directed.
Supply & fixing MCB single pole and neutral (SPN) of capacity 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position, complete all as specified and directed.
Supply & fixing MCB single pole (SP) of capacity 6 Amps to 32 Amps, 240 Volts AC, breaking capacity 10 KA, 'C' series, fixed in proper position, complete all as specified and directed.
Taking down old unserviceable any type of earthing complete with all connected items, complete all as specified and directed.
Taking dwon old unserviceable GI wire with all connected materials, complete all as specified and directed.
Taking down old unserviceable GI strip 32 x 6mm, complete all as specified and directed.
Taking down old unserviceable copper strip 32 x 6mm, complete all as specified and directed.
Taking down old unserviceable copper strip 20 x 3.15mm, complete all as specified and directed.
M&L for earthing of equipment complete with copper earth plate electrode 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 5 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including copper earth strip 20 x 3.15mm, 40mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of soil to a distance not exc 50 mtr and necessary testing on completion, complete all as specified and directed. Note : Earth result after installation completely should be less than 5 Ohm.
M&L for testing and earthing of machinery/equipment installed at power house/Sub Stn/ DB complete with steel earth plate electrode 60 × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 5 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including galvanised earth lead wire 4.0mm, 40mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer-in-charge. Note : Earth lead strip/wire beyond 7.5 mtr shall be measured under respective items of schedule.
All as per item No 75 here-in- above but using galvanised iron strip 32×6mm as earthing lead, complete all as specified and directed.
Supply and fixing in repair 32x6mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip, complete all as specified and directed.
All as per item No 77 here-in- above but copper strip 20 x 3.15mm, complete all as specified and directed.
All as per item No 77 here-in- above but copper strip 32 x 6mm, complete all as specified and directed.
All as per item No 77 here-in- above but galvanised wire 4mm dia, complete all as specified and directed.
S&F HDPE pipes 40mm bore of pressure rating 6 kgf/cm2 laid in trenches/walls and ceilings by MS iron clamp nuts bolts etc, with all fitting and fixed, complete all as specified and directed. Note : Rates inclusive of earth work, cutting chases to walls/ceiling/floor etc.
All as per item No 81 here-in- above but 15mm bore, complete all as specified and directed.
Taking down existing broken earth pit and M & L for new earthing pit in PCC (1:3:6) type C-1 pre-cast RCC cover slab of size 300 x 300 x 50mm with one handle made out of 8mm dia round bar, 20mm dia GI pipe of light grade for watering funnels, wire mesh three coats of white wash on plastered surfaces (exposed surfaces), complete all as specified and as directed.
Supply and fixing porcelain vitreous white/brown/green spacers insulator of size 75mmx35mmx40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50mm long including washers and drilling holes for holding/foxomg aluminium strip/roof conductor as required including taking down the broken insulator, complete all as specified and directed.
M & L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed.
M & L for brazing of copper strip including removing of nut, bolt, washer, from excavation etc and connecting with equipment directly from earthing, complete all as specified and directed.
Servicing, repairing & maintenance of electrically operated over head travelling cranes (EOT), double girder type (normal/flame proof) of 2.0 to 10.0 tonne capacity comprising of electric motor for long travel, cross travel, hoist motion, creeping micro speed and electrical control panel consisting of MCCBs/main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, oil levels, motor bed ends, electrical control cables etc including lubrication/greasing/oiling complete for smooth operation of cranes by skilled service engineer/mechanic, complete all as specified and directed.
All as per item No. 87 here-in- above but HOT/goliatch crane, complete all as specified and directed. Notes for Srl No 87 & 88:- (i) Spare parts replaced shall be measured and paid separately . (ii) The record of servicing shall be maintained by the contractor and shall be produced at the time of payment duly signed by the users, AGE and contractor . (iii) The parts to be checked included in the quoted rates are as under :- (a) Motors- check terminal connections slip rings, carbon bushes alignment of motors, couplings, clutches, brakes if any tight/adjust if required. (b) Wire Rope – check lubrication and number of broken wires. (c) Hook – check for free rotation of hook, lubrication/ greasing/ oiling of moving parts. (d) Electrical – check contactor tips limit switch operating mechanism including connections & testing of LT panel of crane complete. (e) Cleaning of all parts and rail/wheel of cranes. (f) Checking of all movement i.e Long Travel, Cross travel/ lifting and/or any other part(s) as decided by the GE/AGE. (g) Oiling/greasing of bearing of all wheel LT/CT motion mechanism included in the quoted rate.
Material and labour for Load testing of EOT/HOT gantry for cranes of 2 to 10.0 tonne capacity at full load capacity including making arrangements of dead load, complete all as specified and directed. Notes for Srl No 89.00 - (i) The load for load testing and shifting arrangements of load shall be made by the contractor and quoted rates are deemed to be included for this aspect. (ii) The load testing for LT/CT/hoist motion shall be done in the presence of Users and Engr-in-Charge . (iii) A proforma for load testing of each crane shall be maintained and all the parameters mentioned in the proforma shall be tested by the contractor and the record of load testing shall be maintained,duly signed by all concern.
Attending complaints of EOT/HOT crane at AF stn Hasimara, of any capacity, of any nature on emergency call given by concern Engr-in-Charge, JEs by providing skilled service engineer/ mechanic for locating the electrical and mechanical fault and rectification the fault to the entire satisfaction level of the executives, complete all as specified and directed. Notes:- (i) Spare parts required for rectification of fault shall be measured and paid separately as supply and fixing in replacement. (ii) The complaints shall be attended by the contractor within three days. A penalty of Rs. 500/- per day will be recovered/made for not attending the complaint/non rectification of fault beyond Three days, after intimation of concerned AGE/JE in writing. (iii) A penalty of Rs. 6000/- per day (for every 24 hours) will be made for not attending the complaint beyond 7 days. (iv) The contractor will be responsible for providing T & P to the personal deployed, as per requirements for rectifying the fault(s). (v) If the nature of fault for which rectification is involved comes beyond the scope of contract , the same shall not be considered for any type of penalty. (vi) Any minor parts which is not included in BOQ but required for satisfactory operation of EOT crane deemed to be included in quoted rate.
Supply and fixing in repair HRC fuse contacts suitable for 2.0 to 5.0 ton EOT gantry with base, 5 to 16 Amp capacity, complete all aspecified and directed.
Supply and fixing in repair step down transformer suitable for 2.0 to 5.0 ton EOT gantry, complete all aspecified and directed.
Supply and fixing in repair single phase preventer suitable for 2.0 to 5.0 ton EOT gantry, complete all aspecified and directed.
Supply and fixing in repair timer relay suitable for 2.0 to 5.0 ton EOT gantry, complete all aspecified and directed.
Supply and fixing in repair HRC fuse contacts suitable for 2.0 to 5.0 ton EOT gantry with base, 20 to 40 Amp capacity, complete all aspecified and directed.
Supply and fixing in repair brake shoe thrust assembly with lining set suitable for main hoist and for vertical drive of size 2.0/2.5 ton capacity, complete all aspecified and directed.
Supply and fixing in repair brake shoe thrust assembly with lining set suitable for main hoist and for vertical drive of size 5.0 ton capacity, complete all aspecified and directed.
Supply and fixing in repair brake liners of elctro thruster brake assembly for crane of capacity 2.0/2.5 ton, complete all aspecified and directed.
Supply and fixing in repair brake liners of elctro thruster brake assembly for crane of capacity 5.0 ton, complete all aspecified and directed.
Supply and fixing in replacement flame proof push button for pendant and making necessary connections including testing, complete all aspecified and directed.
Supply and fixing in replacement flame proof emergency stop switch for pendant and making necessary connections including testing, complete all aspecified and directed.
Supply and fixing in replacement contactor 3 phase, 415 volts, 30 Amps, type ML 2, complete all aspecified and directed.
Supply and fixing in replacement contactor 3 phase, 415 volts,16 Amps, type ML 1, complete all aspecified and directed.
Supply and fixing in replacement contactor 3 phase, 415 volts,12 Amps, type ML 0, complete all aspecified and directed.
Supply and fixing in replacement over load electro pneumatic relay contactor, mounting type,capacity 8-12 Amps, complete all aspecified and directed.
Supply and fixing in replacement over load electro pneumatic relay contactor, mounting type,capacity 5-8 Amps, complete all aspecified and directed.
Supply and fixing in replacement over load electro pneumatic relay contactor, mounting type,capacity 2-3 Amps, complete all aspecified and directed.
Supply and fixing in replacement over load electro pneumatic relay contactor, mounting type,capacity 1.25 to1.5 Amps, complete all aspecified and directed.
Supply and fixing in repair breaking resister 415 Volts,3 phase, for 2 HP Motor capacity, complete all aspecified and directed.
Supply and fixing in repair breaking resister 415 Volts, 3 phase, for 3 HP Motor capacity, complete all aspecified and directed.
Supply and fixing in repair breaking resister 415 Volts, 3 phase, for 5 HP Motor capacity, complete all aspecified and directed.
Supply and fixing in repair flame proof limit switch, 40 amps rating with one NO & one NC for long travel & cross travel, complete all aspecified and directed.
Supply and fixing in repair flame proof limit switch,40 amps rating with rotory gear of main hoist, complete all aspecified and directed.
Supply and fixing in repair variable speed drive in weather proof sheet metal enclosure suitble for electric operated 2.0 / 2.5 tonne capacity of 3 HP crane installed at site to control cross travel speed and making necessary connections including testing, complete all aspecified and directed.
Supply and fixing in repair variable speed drive in weather proof sheet metal enclosure suitble for electric operated 2.0 / 2.5 tonne capacity of 5 HP crane installed at site to control cross travel speed and making necessary connections including testing, complete all aspecified and directed.
Supply and fixing in repair flame proof pendant suitable for 2.0/2.5 ton capacity gantry, complete all aspecified and directed.
Supply and fixing wheel bearing size 6207 after taking down unserviceable/wornout wheel bearing as existing at site, complete all aspecified and directed.
Taking down/out existing long travel wheel, cross travel wheel from gantry for repair by filling of bronze material by welding & brazing, turning, grinding and refixing the same to make it functional, complete all aspecified and directed. Note: Cost of To & Fro to workshop shall deemed to be included in quoted rate.
Rewinding of motor capacity 2 HP/3 HP, 415 volt, 3 phase with and including super enameled copper conductor as per existing weight, size and design etc including varnishing baking and testing after taking down unserviceable/wornout winding of flame proof/non flame proof motor mounted on rail, complete all aspecified and directed.
Supply and fixing in repair control cable, 1.5 Sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLSH PVC insulated PVC sheathed with supporting steel/GI wire for fixing, complete all aspecified and directed.
Supply and fixing in repair control cable, 2.5 Sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLSH PVC insulated PVC sheathed with supporting steel/GI wire for fixing, complete all aspecified and directed.
Supply and fixing in repair control cable, 4.0 Sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLSH PVC insulated PVC sheathed with supporting steel/GI wire for fixing, complete all aspecified and directed.
Supply and fixing in repair control cable, 1.0 Sqmm 16 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing, complete all aspecified and directed.
Supply and fixing steel wire rope 10mm dia with hemp core rope made in 6x36 pattern length of existing make & specification suitable for 2.0/2.5 tonne capacity gantry fixed with suitable size 'D' clamp, nuts, bolts and washers after taking down unserviceable/wornout/damaged rope as existing at site, complete all aspecified and directed.
Supply and fixing steel wire rope 12mm dia with hemp core rope made in 6x36 pattern length of existing make & specification suitable for 2.0/2.5 tonne capacity gantry fixed with suitable size 'D' clamp, nuts, bolts and washers after taking down unserviceable/ wornout/ damaged rope as existing at site, complete all as specified and directed. Note for srl No. 124.00 & 125.00 :- Nuts, bolts & washers shall be measured & paid seperetely.
Taking down/out travelling crab of double girder 2.5/2.0 tonne capacity, electric operated gantry for rectification of fault and re-installing with and including replacing bearing 5607- 01 No, bush- 01 No, gear- 01 No of make and size as exists,welding, turning,grinding etc and making necessary connections including testing, complete all aspecified and directed.
Dismantling & taking out of gear box of EOT grantry 2500/2000/1000/500 Kg capacity, for rectification of fault & re-installing the same including replacing of unserviceable bearing, buss, gears of existing make and size including turning, welding, grinding and testing, complete all aspecified and directed.
Opening of gear box of EOT crane capacity 0.5/1.0/2.0/2.5 ton, tracing fault of oil leakage, rectifying the same with and including replacement of oil seal/gasket to make it functional, complete all aspecified and directed.
Topping up gear oil with fresh/new gear oil HD90 suitable for gantry, complete all aspecified and directed.
Supply and fixing in repair bearing block of existing make & size at site, complete all aspecified and directed.
Supply and fixing hexagonal or square nuts, bolts with hexagonal or square heads at one end and screwed the other, or screwed both ends, and washers of any size,any type after taking down nuts, bolts and washers etc as exists at site, complete all aspecified and directed.
M&L for dismantling of unserviceable rotating shaft & keyways from travelling crab and transporting to & fro to workshop for checking & repairing and making new keyways including inserting new key as per existing/site requirement for fully functional of EOT crane, complete all aspecified and directed.
M&L for checking electric circuits of any EOT crane and locating the fault, rectifying the fault and replacing the unserviceable parts if required and ensuring furntionality of EOT cranes. Note (i): Parts to be measured and paid seperately under relevant items Note (ii): An amount of Rs.65731.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
SHRI PARTHA DUTTA
BHARAT ELECTRIC
M/S BISHAL ENTERPRISES
M/S. KUMAR CONSTRUCTION CO.
Shri T P ANIL KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .