Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹234.2 CrAccepted-AOC GODREJ WATERSIDE TOWER NO 1 OFFICE 803 8TH FLOOR PLOT NO 5 BLOCK DP SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | ₹234.2 Cr Quoted ₹235.1 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹258.0 CrRejected-AOC | ₹258.0 Cr | L2 | Rejected-AOC NOT LOWEST |
| 3 | Rejected-Technical PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | - | - | Rejected-Technical DOES NOT MEET THE PREQUALIFICATION CRITERIA |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
15 Mar 2021, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC PALAM, DELHI CANTT-10
CONSTRUCTION OF AERO SPACE MUSEUM AT AF STATION PALAM
2019_MES_309782_1
CEWAC/PAL/T-47/2018-19
Open Tender
Civil Works
750 days
PALAM
AS PER NIT
9 documents required · 9 mandatory
₹3,000
GE (AF) FARIDABAD
₹15 L
Yes
HQ CE (AF) WAC PALAM, DELHI CANTT-10
18 Jun 2021
26 Oct 2020
19 Mar 2021
26 Oct 2020
15 Mar 2021
20 Feb 2021
26 Oct 2020 - 3 Dec 2020
10 Dec 2020
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 6 signified this fact only.
Construction of AERO SPACE MUSEUM complete all as specified and shown on drawing.
Construction of Gate Complex Block complete all as specified and shown on drawing.
Construction of Ticket Complex complete all as specified and shown on drawing.
Construction of Electrical Substation complete all as specified and shown on drawing.
Construction of Pump Room complete all as specified and shown on drawing.
NOTE: Schedule ‘A’ Part- II to XI under Ser No. 2.01 to 2.10 are Prepriced by MES.
Lump sum price worked out by the Contractor for “ EXACAVATION AND EARTH WORK (Site Clearance and development) ” as listed in Schedule ‘A’ Part- II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part- III
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part- IV
Lump sum price worked out by the Contractor for “AREA/STORM WATER DRAINAGE ” as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part- VI
Lump sum price worked out by the Contractor for “RETANING WALLS FOR DEVELOPMENT” as listed in Schedule ‘A’ Part- VII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION, SUBSTATION EQUIPMENTS AND DG SET ” as listed in Schedule ‘A’ Part- VIII
Lump sum price worked out by the Contractor for “COMPOUND WALL, FENCING & GATE” as listed in Schedule ‘A’ Part- IX
Lump sum price worked out by the Contractor for “ROAD, PATH & HARDSTANDING ” as listed in Schedule ‘A’ Part- X
Lump sum price worked out by the Contractor for “WATER BODIES ” as listed in Schedule ‘A’ Part- XI
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
EXACAVATION AND EARTH WORK (Site Clearance and development)
Use and waste for timbering as planking and strutting for excavations in trenches in soil, including wales, struts, open poling boards, etc. as may be necessary and fixing and removal, complete all as specified and directed.
For depth exceeding 4.50 m but not exceeding 6.00 m
For depth exceeding 6.00 m but not exceeding 7.50 m
INTERNAL PLUMBING AND DRAINAGE
Sanitary Fixtures
Supplying, fixing, testing and commissioning of white vitreous china wall mounted type European water closet with built-in exposed cistern of capacity 2/6 litres with C.P. bolts, nuts, supporting arrangements, bakelite seat & cover with C.P. hinges & rubber buffers complete with all accessories. Including cutting & making good the walls & floors wherever required in all respect, complete all as specified and directed. Make: Parryware Code - C02551C + E83081C + E812099 + C8218A1 or equivalent as per list of make.
Supplying, fixing, testing and commissioning of water closet squatting pan White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, 6/3 litre dual flush low level white P.V.C.flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required, complete all as specified and directed. Make: Parryware- C0117 + E8177 or equivalent as per list of make.
Supplying, fixing, testing and commissioning of ABS Rinsing spray with regulator of approved quality with plastic flexible pipe 1.5 m long, wall hooked etc., complete all as specified and directed. Make: Parryware Code - T9803A1 or equivalent as per list of makes
Supplying, fixing, testing and commissioning of wash basin under counter basin 500mmx350mm with CP brass waste assembly, CP cast brass bottle trap with extension piece, wall flanges and rubber adapters for waste connection complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required in all respect, complete all as specified and directed. Make: Parryware Code - C04191C + T3201A1 or equivalent as per list of make.
Supplying, fixing, testing and commissioning of single hole basin mixer with pop-up waste & brass nuts complete as required, complete all as specified and directed. Make: Parryware Code - G3165A1 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of Self Closing Tap, complete all as specified and directed. Make: Parryware Code - T2022A1 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of white colour vitreous china urinal of supported by CI / MS bracket duly painted, including CP brass dome waste, spreader with connection pipe, CP cast brass bottle trap with extension piece, wall flanges complete with all accessories and as per manufacturers specifications, complete all as specified and directed. Make: Parryware Code - C0580+C8123 or equivalent as per list of make.
Supplying, fixing, testing and commissioning of battery operated infrared, touch free urinal flushing device with internal isolating valve and the control shall be comprises of plastic casing with cleaning cover, front panel with sensor, solenoid valve with filter. flushing cycle shall be including all accessories complete as required, complete all specified and directed. Make: Parryware Code - C8295 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of white vitreous china large urinal partition with concealed CI bracket, cutting and making good, complete all specified and directed. Make :Parryware Code - C057 or equivalent as per list of makes
Supplying, fixing, testing and commissioning of Stainless steel sink single bowl sink supported by C.I./M.S. Brackets duly painted, C.P. cast brass bottle trap with extension piece, rubber adaptor, wall flange, union, C.P. brass chain rubber plug & making good, complete all specified and directed. Make: Parryware Code - C852099 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of sink mixer with C.P. wall flange, overhead swinging spout complete as required and making good, complete all specified and directed. Make; Parryware Code - T3653A1 or equivalent as per list of makes.
Supplying & Fixing Recessed type toilet paper holder, complete all specified and directed. Make: Parryware Code - T6514A1 or equivalent as per list of makes.
Supplying & Fixing liquid soap Dispenser with glass bottle, complete all specified and directed. Make; Parryware Code - T6513A1 or equivalent as per list of makes.
Supplying & fixing twin coat hook, complete all specified and directed. Make; Parryware Code - T6007A1 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of 15 mm dia bib cock with C.P. wall flange of approved quality, complete all specified and directed. Make: Parryware Code - T3504A1 or equivalent as per list of makes.
Supplying, fixing, testing and commissioning of angle valve with C.P. wall flange, Nut and Washer etc, complete all specified and directed. Make:Parryware Code - T3707A1 or equivalent as per list of makes
Supplying, fixing, testing and commissioning of connecting hose 1.5 ft.(45cm) long including nuts and washers and making connection to fixtures and fittings, complete all specified and directed.
Supplying, fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, complete all specified and directed. Make: Parryware Code - FCS/AC/MIS/6022 or equivalent as per list of makes
Supplying, fixing, testing and commissioning of "No" touch operating hand drier rated for continuous repeat use, suitable for single phase, 230 volts, 50 Hz A.C with sound level 70 dBA one integral bracket including cable from drier to plug, Plug top key and lock etc., complete all specified and directed. Make: JVD, Code - 811413 or equivalent as per list of make.
Supplying, fixing, testing and commissioning of following capacity of horizontal/vertical type electric water storage heater, having rust proof powder coated outer body, 2 in 1 presence and vacuum release valve, inner container made from S.S sheet, puff insulated, thermal cutout and semi return device fixed to the wall with bolt and nuts including making connection with inlet and outlet pipe, cutting and making good the wall complete in all respects, complete all specified and directed.
5 Litre
10 Litre
15 Litre
Cold/Hot Water Supply (Internal) Supplying, fixing, jointing, testing & commissioning in position of following sizes of heavy class (Class C) MS pipes conforming to IS:1239 cut to required lengths including two coats of Synthetic enamel paint of approved shade on exposed MS Pipes as per IS:2379 over a coat of primer. All necessary fittings (All fittings shall confirm to IS:1879 - part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc. Fixing at wall/ceiling level supported by galvanized clamps, hangers etc, as per specification. Threading, jointing, and making proper connections. Cutting hole in wall / floor / slab and making good the same. MS pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end .Two coats of Synthetic enamel paint of approved shade on exposed MS Pipes (or other pipe of nearest/equivalent diameter, as applicable) as per IS:2379 over a coat of primer including painting of legends with direction arrow as per the approval, complete all specified and as directed.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
Supplying, fixing, jointing, testing & commissioning in position following sizes of CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR - 11 at a pressure rating of 28.1 kg/cm2 at 23 deg C & 8.79 kg/cm2 at 82 deg C, using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to IS 15778 ,ASTM D-2846 with only CPVC solvent cement conforming to ASTM F-493,pipe clamp with EPDM rubber lining also including cutting of chases and making good the wall etc., complete all specified and as directed.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
Supplying & fixing of following sizes of full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.(suitable for test pressure of 16 kg/cm2), complete all specified and as directed.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Supplying & fixing of following sizes of cast iron butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.(suitable for test pressure of 16 kg/cm2), complete all specified and as directed.
65 mm dia
80 mm dia
Supplying and fixing of following sizes of motorized butterfly valve with float type sensors suitable for 220 volts with working pressure rating PN 1.6 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box ( upto 6 mt approx) etc. complete. Valve shall be as per IP-67, complete all specified and as directed.
40 mm dia
80 mm dia
Design, supplying & fixing Overhead MS tank fabricated out of 10mm thick MS sheet duly painted internally with anti corrosive paint and externally with synthetic enamel paint over a coat of red oxide primer for Fire including all inlet & outlet connection and all necessary accessories as required, complete all specified and as directed.
Internal Drainage (Soil, Waste,Vent & Rain water)
Supplying, fixing, jointing, testing and commissioning of following sizes spun/centri Cast Iron pipe for soil, waste, pipes installation conforming to IS:3989 cut to required lengths including all necessary fittings and specials such as Bends, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with drip seal joint of required depth as per BIS / manufacturer. Cutting, chases/holes in floors / walls / slab. Supplying GI pipe sleeves of suitable higher size wherever pipes crossing a fire rated wall / floor slab and sealing of space around pipe and pipe sleeve with glass wool in between and fire proof sealant at either end to the satisfaction of the Project Manager / Consultants and making good the same after pipes have been duly laid and testing, complete all specified and directed.
75 mm dia
100 mm dia
150 mm dia
M&L for painting of Exposed Cast Iron pipes and fittings (after installation) of following sizes with two coats of synthetic enamel paint of approved shade over a coat of primer, all as per pipe colour code including painting of legends with direction arrows, complete all specified and directed.
75 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of 100 mm dia GI clean out plug comprising of GI epoxy coated flanged tail piece caulked to pipe and GI epoxy coated blind flange with EPDM gasket , necessary nuts, bolts and washers & socket. Including drip seal joints complete as required, complete all specified and directed.
Supplying, fixing, jointing, testing and commissioning of 100 mm dia Brass floor clean out plug comprising of GI socket caulked to pipe and brass male threaded plug with punch for opening ,suitable inlet key for opening GI class C pipe & socket. Including drip seal joint to CI pipes complete as required, complete all specified and directed.
Supplying, fixing, jointing, testing and commissioning of 100 mm inlet and 100 mm outlet CI full bore P / S trap (IS : 3989 ) of the following sizes including providing necessary galvanized steel support and as per Specification. Making proper connection with refined pig lead joints, cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. All traps shall have minimum 50 mm deep water seal, complete all specified and as directed.
Supplying, fixing, jointing, testing and commissioning of 100 mm dia G.I. inlet hopper with two or three inlets fittings to receive waste pipes from fixtures waste. The hopper shall be fabricated from 100 mm dia upto 450 mm long G.I. heavy class pipe and welded G.I. sockets, fixed to C.I. trap with drip seal joint and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 complete as required. The hopper shall be hot dip galvanized after fabrication, complete all specified and as directed.
Supplying, fixing, jointing, testing and commissioning 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe, complete all specified and as directed.
Supplying, fixing, jointing, testing and commissioning following sizes of G.I. pipe and fittings of heavy class (Class C) conforming to IS:1239 (for waste pipe from individual fixtures to floor trap / floor drain including fixing at wall/ceiling level supported by galvanized clamps and hangers etc, complete all as specified and as directed.
32 mm dia
40 mm dia
50mm dia
Supplying, fixing, jointing, testing and commissioning following size of UPVC pipe (Rain water) conforming to IS:4985 of 10 Kg/Sqcm rating cut to required lengths including all necessary fittings as IS:7834(moulded) & IS:10124 (fabricated) and specials such as Bends, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers, structural supports, fasteners, etc. Making proper connection with push on rubber type joint of required depth as per BIS / manufacturer, complete all as specified and directed.
110 mm OD (Outside Diameter)
160 mm OD (Outside Diameter)
200 mm OD (Outside Diameter)
M&L for Cutting & chasing in walls & floor for 32 mm dia to 50 mm dia waste pipes & fittings and making good the same by using 1:1 cement mortar, complete all specified and directed.
Supply, laying and testing of 250mm dia non-pressure RCC Pipes NP2 class (light duty) with single socket jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) in trenches, including testing of joints etc, complete all specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in concrete bed to drain pipes 250mm bore including packing under and hunching against the side of pipe after they are laid and tested, complete all specified and directed.
INTERNAL ELECTRIFICATION
S&F ceiling fan five star rated 1200mm sweep complete with out fan regulator 230 volts (single phase) and provisioning of PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 0.50sqmm of required length from ceiling rose or connector to ceiling fan for giving connection, complete all as specified and directed. Note: Ceiling rose shall be measured and paid separately
S&F metal exhaust fan with louvers of size 300 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 0.50sqmm from ceiling rose to exhaust fan for giving connection, complete all as specified and directed.
S&F stepped type electronic modular fan regulator 120W- 2 module, complete all as specified and directed.
S&F for 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, complete all as specified and directed.
5 to 32 Amps Singe pole MCB
63 Amps SP MCB
16 Amp TP MCB
40 Amp TP MCB
63 Amp TP MCB
S&F single pole blanking plate in the existing MCB DB, complete all as specified and directed.
S&F single pole blanking plate in the existing cover plate complete as required, complete all as specified and directed.
S&F MCB 'C' curve having rupturing capacity 10kA, double pole, 63 A, 240 V in the existing MCB DB complete with connections etc, complete all as specified and as directed
S&F four pole, 415 V, following rating isolator in the existing MCB DB complete with connections etc, complete all as specified and directed.
S&F residual current circuit breaker (RCCB), following rating, TPN (three phase and neutral), 415 V, having a sensitivity current 30 mA in the existing MCB DB complete with connections etc, complete all as specified and directed.
M&L providing and fixing 16 module heavy duty universal metal in screed back box (colour of plate shall be approved by GE) (to be provided in the main museum for 6 amps switches and socket), complete all as specified and directed.
M&L for following modular switch/ socket on and including modular cover plate of approved colour fixed on MS modular flush box of required size including connections, complete all as specified and directed
Telephone socket outlet
RJ-45 Computer Socket Outlet
T.V outlet
M&L of following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit, complete all as specified and directed. Note: Conduit and cable tray shall be measured and paid separately.
M&L for CAT 6 PVC insulated annealed copper conductor, unarmored cable in the existing surface/ recessed steel/ PVC conduit as required. Note: Conduit shall be measured and paid seperately
S & F rigid non metalic PVC conduit of following sizes including all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc, complete all as specified and directed.
25 mm dia
32 mm dia
Supply and fixing of perforated stove enamelled M.S sheet steel slotted cable trays of size 150 mm x 50 mm x 50 mm x 1.6 mm with vertical sides on both ends as per approved design and MS angle supports spaced 1000 mm apart throughout the length but 600mm from bending lines on both size of bands as specified, including the cost of 1 meter MS rod hangers, hooks, dash fasteners, painting etc. for suspension from ceiling, complete all as specified and directed.
Supply and fixing of the following sheet steel clad wall/recess/floor mounting telephone tag block of Krone made constructed from 14 SWG sheet steel, finished with red oxide coating of two coats of paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires. The cost shall be complete with fixing arrangements, foundations etc as required, complete all as specified and directed.
M&L of chemical maintenance free earthing consisting of earth electrode size 32 mm dia and 3 meter long made of high tensile low carbon steel circular rods, molecularly bonded copper on the outer suface having copper bonding thickness 250 microns to conforming with requirements of UL467-2007. The electrode shall be placed in a bore hole of 300mm dia duly filled with earth enhancing compound conforming to BS 7430 IEEE-80, earth electrode connected to copper earth lead 32x6mm upto and including test point made of copper strip, Pit in PCC 1:2:4 type B-1 all as required at site and specified in IS 3043, EP No 3 of SSR Part-1. Note: i) Cost of earth work required is deemed to be included in over all cost quoted by the contractor. ii) Resistance value of the earthing system shall be less than 1 ohm and value must be submitted by contarctor before payment is release.
Supply, laying, jointing and testing of XLPE cable of folowing cross sectional area insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with copper stranded conductor 1100 volts grade, laid in trenches, passing through ducts/pipes, fixing along poles, fixed to cable trays, wall etc, complete all as specified and directed. Note: a) Earth work, sand cushioning, brick protection, hume pipe of cable tray shall be measured and paid separately b) Pre despatch inspection by rep. of accepting officer shall be carried out within overall cost quoted for each cable size where length exceeds 500 RM. c) Color code for cable shall be finalised by G.E
2Core X 6 sqmm
2Core X 10 sqmm
2Core X 16 sqmm
4Core X 10 sqmm
4Core X 16 sqmm
3Core X 2.5 sqmm
4Core X 4.0 sqmm
4Core X 6.0 sqmm
M&L for end termination with brass compression gland, heat shrink insulating sleeves and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade, complete all as specified and directed.
2 Core X 6 sqmm (19mm)
2 Core X 10 sqmm (19mm)
2 Core X 16 sqmm (22mm)
4 Core X 10 sqmm (25 mm)
4 Core X 16 sqmm (28mm)
4 Core X 25 sqmm (28mm)
4 Core X 35 sqmm (32mm)
3½ Core X 50 sqmm (35 mm)
3½ Core X 70 sqmm (38mm)
3½ Core X 95 sqmm (45 mm)
4 Core X 6.0 sqmm
3½ Core X 150 sqmm
3½ Core X 300 sqmm
SWBD -GF-1 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note:i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. v) General Arangement drawings shall be got approved by Accepting Officer before fabrication vi) Pre - dispatch inspection of panel shall be carried out by Rep. of Accepting Officer.
SWBD -GF-2 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication vii) Pre - dispatch inspection of panel shall be carried out by Rep. of accepting officer and provision of same shall be deemed to be included within overall cost quoted by contractor.
SWBD -GF-3 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SWBD -GF-31 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii)The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position vi) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SWBD -FF1 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SWBD -FF2, SWBD -SF1 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vii) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SWBD -SF2 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc , all as specificed and directed including following accessories as below. Note:i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SUBSTATION PANEL Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc , all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
UTILITY BLOCK PANEL Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc, all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position iv) Suitable arrangement shall be made for termination of multiple incoming cables v) All kA values indicated shall be Ics breaking capacity. vi) General Arangement drawings shall be got approved by Accepting Officer before fabrication
SWBD-UPS 1 Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access Free standing/Wall mounted, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc , all as specificed and directed including following accessories as below. Note: i) All Switchboards shall have provision for entry of cables from the top or bottom as required ii) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. iii) The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. General Arangement drawings shall be got approved by Accepting Officer before fabrication
S&F sheet metal enclosures Vertical type (VTPN) double door suitable for 4 pole MCCB as incomer and outgoings TPN MCB for following ways, IP 43 protection, 415 Volts, complete all as specified and directed.
DIGITAL LIGHTING MANAGEMENT SYSTEM (FOR AUDITORIUM) Supply, Installation, Testing ,commissioning & programming of Lighting Control Panel Homework’s® QS processor with built-in astronomical clock, Processor Link- 2, RJ-45 ports with built in switch for daisy chaining processors (max 16 processors) shall have 2 links that can be individually configured as one of three types: QS Wired Link, QS Wireless Link or Panel Link. QS Wired Link: 100 devices per link, 512 zones per link, 600m max wire length Panel Link : 16 panels per link, 256 zones per link QS Wireless Link: 100 devices per link, 100 zones per link, utilizes hybrid repeater( 4 repeaters per link). + Power supply for Processor. + Low Voltage Enclousre for Processor and required software for control, complete all as specified and directed.
S&F DIN Rail mounted 4-zone Switching module, with 4 corresponding feed through 10 Amp switch outputs rated for inductive, capacitive, or resistive loads. Includes QS communication link to any QS device (max 100) and one contact closure input /output link, complete all as specified and directed.
S&F 4 Zone 0-10 volt dimming module can dim T5, FL or LEDs, with 4 corresponding feed through 10 Amp switch outputs each 0-10 volt output can source or sink 50ma per output, complete all as specified and directed.
S&F DALI Module , Controls 2 independent DALI links with up to 64 DALI ballasts per Link,max 16Scenes per Link, complete all as specified and directed.
S&F 10 Button with Artic White Finish, complete all as specified and directed.
S&F Local Enclosure Big Size, complete all as specified and directed.
Note: 1) All wiring should be as per wiring diagram, which is to be provided by manufacturer. 2) Keypads to be located in each area as per consultation with designer 3) All the lighting circuits of all the areas shall be brought to Dimming Panel 4) All the circuits should have 3-wires of 2.5 sqmm as phase, neutral and Earth. The circuits which requires Dimmable ballast for dimming and they do require two-control wire (low voltage) of 1.5 sqmm per circuits other than phase, neutral and earth in a separate conduit. 5) The cost of dimming Ballasts or dimmable LED drivers (1-10 volts) as required to be considered in above items.
DIGITAL LIGHTING MANAGEMENT SYSTEM (FOR MAIN MUSEUM)
S&F DIN-rail mounted DALI Module for DALI-compliant Digital Addressable loads. It provides DALI bus power and control for two independent DALI loops with up to 64 ballasts each. Each DALI® Bus can control a maximum of 16 zones, complete all as specified and directed.
S&F QS Sensor Module (QSM) is a ceiling-mounted device that integrates LutronR wireless sensors and controls through the QS communication link. It can received the input from wireless 10 Pico, Occupancy Sensor, Daylight sensor, complete all as specified and directed.
S&F Wireless Mullion Shadow Sensor 865 Mhz Sensors to capture cloud and shadows ,10-year typical battery life reduces maintenance costs,Single / Multi group controls available thru software,Front accessible buttons make set up easy, Interior mount ensures protection from outdoor elements,Discrete design for minimal aesthetic impact,Works with tinted and reflective glass surfaces,opening shades during cloudy conditions or in response to shadows from neighboring buildings ,lowering them in overly bright conditions such as glare reflected from neighboring buildings, complete all as specified and directed.
S&F Lutron 8 Scene Keypad with Master Raise/Lower(Plastic Finish), complete all as specified and directed.
S&F Local Enclosure (Big Size), complete all as specified and directed.
Note: 1) All wiring should be as per wiring diagram, which is to be provided by manufacturer. 2) Keypads to be located in each area as per consultation with User/MES 3) All the lighting circuits of all the areas shall be brought to Dimming Panel 4) All the circuits should have 3-wires of 2.5 sqmm as phase, neutral and Earth. The circuits which requires Dimmable ballast for dimming and they do require two-control wire (low voltage) of 1.5 sqmm per circuits other than phase, neutral and earth in a separate conduit. 5) The cost of dimming Ballasts or dimmable LED drivers (1-10 volts) as required to be considered in above items.
40 kVA UPS System Supply, installation, testing and commissioning of UPS system comprising of 2 nos 40 kVA, input 3 phase 304 to 477 volts and out put 3 phase and neutral 415 V + 1% units connected in parallel redundant configuration with load sharing mode each with internal battries suitable for backup of 30 minutes duration for full load and with all standards fittings, accessories, protection, instruments, indications and controls including but not restricted to transformer, rectifier, inverter, SMF battery with float cum boost battery charger, static bypass switch, maintenance bypass, output isolation transformer, interconnections etc. including warranty and free all inclusive comprehensive maintenance services for one year after the date of completion, complete all as specified and directed. Note; Cost of specified number of battery and MS iron stand for placing batteries is included in overall rate quoted by the contractor
LIGHT FIXTURES Supply, Installation, testing and commissioning of following light fixtures with all components and accessories having lamp holders and including cost of control gears/lamps, complete all as specified and directed. Note: For Srl Item No 11.91 to 12.34 i) Next higher wattage to be installed if specified wattage is not available with the approved manufacturer. ii) Minimum 2 year warranty certificate to be enclosed before release of payment iii) Any make from the list of make (Appendix 'D') shall be approved but equivalent to model/Cat Part No as described in each item. iv) Driver and luminaire shall be of same manufacturer.
Recess ceiling LED downlighter (15.5 W LED) CRI > 80 Make : 1. Philips : DN 394 LED 16S - 4000 PSU WH 2. Trilux : Ambella IND G3 LED 1250 - 840 E2 3. LED Liniear (Lighting Legend in drawing -RC1)
Recess ceiling LED downlighter (9 W LED) CRI>80 Make: 1. Philips : DN 392 LED 10S - 4000 PSU WH 2 Trilux : Ambella Plus IND G3 LED 1000- 840 ET 3. LED Liniear (Lighting Legend in drawing -RC2)
Recess ceiling 2Ftx2Ft light (40W LED) : CRI > 80 Make: 1. Philips RC 170B LED 29S - 4000 PSE WH 2 Trilux Enteno IND M41 OA LED 2000 - 840 ETD 3. i LED (Lighting Legend in drawing -RC5)
Recess ceiling 2Ftx2Ft light (36W LED) CRI > 80 Make: 1. Philips RC 420B LED 35 S/840 PSU W60L60 G 2 Trilux Enteno IND M41 OA LED 2000 - 840 ETD 3. i LED (Lighting Legend in drawing -RC6)
Recess ceiling 2Ftx2Ft light (38W LED) Make: CRI > 80 Make: 1. Philips CR 652 B LED 33SCRCW CA 2 Trilux Enteno IND M41 OA LED 2000 - 840 ETD 3. i LED (Lighting Legend in drawing -RC7)
Reflex Fixed round luminaire designed to use a LED lamp with C.O.B. technology. Version with rim for surface-mounting with 9.3W LED 1500lm, 3000K Optic: WF - Wide Flood 44° ADJUSTABILITY CRI > 80 Fixed Electronic Transformer included CRI > 80 Make: 1. iGuzini MV 89 2 ERCO - 45027.000 3 Zumbotal : DIMO R68LED 1700-930FLWH (Lighting Legend in drawing -RC8)
Surface ceiling LED down lighter(1x15W LED ) Make : 1. Philips DN 170C LED 10S 4000 PSU WH 2. Trulex 3 LED Linier (Lighting Legend in drawing -SC1)
Surface ceiling LED down lighter (1x18W LED ) CRI > 80 Make 1. Philips SM 251C LED 20S 4000 PSU WH 2.. Trilux 3 LED Linier (Lighting Legend in drawing -SC2)
Mirror Light (1x22W LED) CRI > 80 Make 1. Philips BN 021 LED 205 PSW NW GR 4000k 2.. Trilux TRL OTA 1800-800ET 3. Thorn (Lighting Legend in drawing -SW1)
LED Surface wall light Make : CRI > 80 Make : 1. Philips LL 199X 1X DLED 57-4000 PSE 2 Trilux 76500TR LED 500-800 ETDD 6813151 3. Thorn (Lighting Legend in drawing -SW2)
Step light Linear LED stright 5mtr (8W) CRI > 80 Make : 1. Philips LS 1515 LED6/NW 5000 IN 2 Trilux TRL OTA 1800-840 ET 3. Thorn (Lighting Legend in drawing -SW3)
Surface wall bracket Light (8W LED) Make : 1. Philips 40947 WALL DEW PHILIPS 2 Trilux 3 i LED (Lighting Legend in drawing -SW4)
LED Surface wall up/down CRI > 80 Make : 1. Philips BY 415 LED 90S CW WB FG PSU GR S2 2. Trilux LBL 11500 ET 90D - NW 3 i LED (Lighting Legend in drawing -SW5)
Pendent light 20W Endura LED Batten CRI > 80 Make : 1. Philips LL199X1D LED 57-4000 PSE OD WH 2 Trilux 76500TR LED 5500840 ETDD 6813151 3 Thorn (Lighting Legend in drawing -SW5)
Pendent light 20W Endura LED Batten CRI > 80 Make : 1. Philips BN 108C LED 20S PSU NWWH 2 Trilux 3 Thorn (Lighting Legend in drawing -PC3)
Pendent light 40W Endura LED Batten Make : CRI > 80 Make : 1. Philips BN 108C LED 40S PSU NWWH 2 Trilux: TRL OTA 3600 - 840 ET 3 Thorn (Lighting Legend in drawing -PC4)
Decorative pendent light Make : 1. Philips LED QPG 304 2 iGuzzini 3 i LED (Lighting Legend in drawing -PC7)
Decorative pendent Light (2W LED) Make : 1. Philips LED 40902 AYR PENDANT 2. iGuzzni 3 i LED (Lighting Legend in drawing -PC9)
Recess wall step light (3.6W LED) CRI > 80 Make : 1. Philips BWG 150 LED LED 50/NW PSU 220-240 IP67 7043 2. Trilux 3 Thorn (Lighting Legend in drawing -RW1)
Reflex Fixed round luminaire designed to use a LED lamp with C.O.B. technology. Version with rim for surface-mounting with 13W LED 2000lm, 3000KOptic: WF - Wide Flood 64°adjustability fixed IP 54 Electronic Transformer included CRI > 80 Make: 1. iGuzzini iGuzziniMV99 2. ERCO - 46033.000 3. Zumtobel : DIAMO R68LED 1900 930 VFL WH (Lighting Legend in drawing - RC3)
48 V, 17W/m, W830, 3000K, 2260lm/m, flexible LED strip (step measurement = 280 mm) with reflecting white surface and 3M adhesive tape on the back. Protected against electrostatic discharge +/– 2,000V. Make : 1. LED Linaer XOOMINESCENT™ HE or LED Linear - Xoominescent HE - 17W/Mtr 2. KKDC - TiMi 508 3. ACBC (Lighting Legend in drawing -L1)
48 V, 34W/m, W830, 3000K, 3630lm/m, flexible LED strip (step measurement = 280 mm) with reflecting white surface and 3M adhesive tape on the back. Japanese LEDs of the highest quality with 120° beam angle. CRI up to 85 and “One Bin Only” within 3 MacAdam guarantee constant color temperature and highest light quality at a lifetime of >60,000hrs (L80/B10). Can be used with VarioContour 007 and reflectors: 25°, 65° and Wallwash. Protected against electrostatic discharge +/– 2,000V. Made in Germany CRI > 80 Make : 1. LED Linaer XOOMINESCENT™ HE 34W/mtr 2. KKDC - TiMi 508 3 ACBC (Lighting Legend in drawing -L2)
Muna/Bos Diffused light ceiling- / wall-mounted luminaire with 21W LED 2170lm, 3000K Optic: GL - General lighting adjustability: fixed IP 40 Electronic Transformer included Size (mm): ø426x125 Make: 1. iGuzzini 5031 2. WE - EF 195-9548 3. Zumtobel - Helissa (Lighting Legend in drawing -WL1)
48V, 17 Watts/Meter, linear fixture with small form factor of 49 mm x 79 mm for indoor environment. LED modules are powered with 3 Step MacAdam, single bin high efficiency Japanese produced LM80 compliant LEDs with a lifetime of 60000 hours @ L80/B10 in accordance with standard TM-21-11. CRI > 85. This line is with integral driver, having safety protection class II, S.E.L.V. PSU as per end user requirement, and conforming to BIS norms.Length = 1135mm CRI > 80 OR LED Linear - Light Line 50 Zumtobel - SLOTLIGHT infinity Opal LTS - LK-P 070.005.1 AOB Make: 1. LED Linear Light Line 50 2 Zumtobel - SLOT Light infinity opal 3 LTS - LK P070.005.0 AOB (Lighting Legend in drawing -WL2)
Linear fixture with trim and bold form factor of 99 mm x 95 mm. in indoor environments. 3000 K delivering up to a high output of 3960 lumens/meter, CRI > 85. This line is with internal driver, Safety rotection class II. Length = 1135mm Make: 1. LED Linear LL100-HE-OW IP40 2 Zumtobel - SLOT Light infinity opal 3 LTS - LK P070.005.0 AOB (Lighting Legend in drawing -WL2A)
24 V, 25W/m, 3000K, 2910lm/m, modular, light intensive linear LED luminaire in IP20 with adjustable luminaire head (45°) and 3 highly efficient and precise reflector optics. as surface-mounted or pendant version. 2 m black cable with open end on one side. LED. CRI up to 96. Binning 3 MacAdam. Lifetime of > 60,000 hrs (L80/B10). Length = 500mm Make: 1. LED Linear - Xoolum R 2 Hydra LD25 - 25W/Mtr 3. Prolicht - Magic Wall Wash (Lighting Legend in drawing -XL2)
iPro Floodlight designed to use Warm White COB LED lamps with a wide flood optic with 35W LED 5300lm, 3000KOptic: WF - Wide Flood 48° adjustability: directional Electronic Transformer DALI/ Push Dim Dimmable includedIP66Refractor for the elliptical distribution of the light flowSize (mm): 192x192x200 CRI > 80 Make: 1. iGuzzini BX25+BZ80 2. Erco - 34622.000 3. WE-EF 146-7062 (Lighting Legend in drawing -SG1)
iPro Floodlight designed to use Warm White COB LED lamps with a medium optic with 35W LED 5300lm, 3000KOptic: M - Medium 16° adjustability:directional Electronic Transformer DALI/ Push Dim Dimmable included IP66 Size (mm): 192x192x200 Make: 1. iGuzzini BX21 2. Erco - 34620.000 3. WE-EF 146-7064 (Lighting Legend in drawing -SG2)
Palco Adjustable spotlight with adapter for installation on mains voltage track for high-performance LED with 20W LED 2000lm, 3000K Optic: S - Spot 12°Adjustability: directionalElectronic Transformer Dimmable included IP40: for optical assembly Make: 1. iGuzzini P207 2. ERCO 71239.000 3. Fagerhult - Touch Midi 58071 (Lighting Legend in drawing -TL1)
Palco Adjustable spotlight with adapter for installation on mains voltage track for high-performance LED with 20W LED 2000lm, 3000KOptic: M - Medium 20°Adjustability: directional Electronic Transformer Dimmable included IP40: for optical assembly Make: 1. iGuzzini P208 2. ERCO 71239.000 3. Fagerhult - Touch Midi 58071 (Lighting Legend in drawing -TL2)
Palco Adjustable spotlight with adapter for installation on mains voltage track for high-performance LED with 20W LED 2000lm, 3000KOptic: F - Flood 38° Adjustability: directional Electronic Transformer Dimmable included IP40: for optical assembly Make: 1. iGuzzini P209 2. ERCO 3 Fager hult (Lighting Legend in drawing -TL3)
Palco Adjustable spotlight with adapter for installation on mains voltage track for high-performance LED with 20W LED 2000lm, 3000KOptic: F - Flood 38°Adjustability: directionalElectronic Transformer Dimmable included IP40: for optical assemblySize (mm): ø102x204 Make: 1. iGuzzini P210 2 ERCO 2 Fager hult (Lighting Legend in drawing -TL4)
Angular_2 : IP20 rated Angular is a three-phase track spotlight featuring high versatility and easy installation. The sleek essential design perfectly combines with excellent light performance, ensured by a arrayLED source and by the presence of a tilting movement up to 45 degrees supported by a practical degree indicator for precise tilt adjustment. The model can be matched with three different types of optics and fitted with a variety of accessories, including flaps and anti-glare filtering systems. Passive heat dissipation, Aluminium casing, 60° Optics. Black Finish. Dimensions : Dia/length=140/200mm. Make: 1. i-Led Linealight 2 MARTINI - MIL0L139 TRACK SPOT 33288 3 AMERUX - 1 C4TV - A14/46 LED/BT/GA100/240/FL/3000K/CE (Lighting Legend in drawing -TL5)
Angular_2 : IP20 rated Angular is a three-phase track spotlight featuring high versatility and easy installation. The sleek essential design perfectly combines with excellent light performance, ensured by a arrayLED source and by the presence of a tilting movement up to 45 degrees supported by a practical degree indicator for precise tilt adjustment. complete with accessories, including flaps and anti-glare filtering systems. Passive heat dissipation, Aluminium casing, 60° Optics. Black Finish. Dimensions : Dia/length=140/200mm. C/W anti-glare screen- Make: 1. i-Led Linealight 2 MARTINI - MIL0L139 TRACK SPOT 33288 3 AMERUX - 1 C4TV - A14/46 LED/BT/GA100/240/FL/3000K/CE (Lighting Legend in drawing -TL6)
Angular_1 : IP20 rated Angular is a three-phase track spotlight featuring high versatility and easy installation. tilting movement up to 45 degrees supported by a practical degree indicator for precise tilt adjustment including flaps and anti-glare filtering systems. Passive heat dissipation, Aluminium casing, Three levels of light performances available, black finish, 15 degree optic, Dimensions : dia/length=100/153mm. C/w Anti glare screen Make: 1. i-Led Linealight 2 MARTINI - MIL0L139 TRACK SPOT 33288 3 AMERUX - 1 C4TV - A14/46 LED/BT/GA100/240/FL/3000K/CE (Lighting Legend in drawing -TL7)
Angular_2 : IP20 rated Angular is a three-phase track spotlight featuring high versatility and easy installation. The sleek essential design perfectly combines with excellent light performance, ensured by a arrayLED source and by the presence of a tilting movement up to 45 degrees supported by a practical degree indicator for precise tilt adjustment. The model can be matched with three different types of optics and fitted with a variety of accessories, including flaps and anti-glare filtering systems. Thanks to its high technical performances, Angular is particularly suitable for illuminating places of art and worship, public spaces and shops, Passive heat dissipation, Aluminium casing, Three levels of light performances available, based on the customer’s needs. 30° Optics. Black Finish. Dimensions : Dia/length=140/200mm. C/W anti-glare screen Make : i-Led, Linealight, Italy 95882.W.30 + 98504- Make: 1. i-Led Linealight 2 MARTINI - MIL0L139 TRACK SPOT 33288 3 AMERUX - 1 C4TV - A14/46 LED/BT/GA100/240/FL/3000K/CE CRI > 80 (Lighting Legend in drawing -TL8)
Ceiling surface mounted customized LED fixture, oval shaped, 3meter length with acrylic opal diffuser as per drawing with 150W LED, 3000K and integrated driver all as per drawing Make: LSI or equivalent in Bajaj, Philips, Halonix
Floor standing customized LED fixture, 3meter high with head made of acrylic opal diffuser of 1.5meter height & 450mm diameter. 25W LED, 3000K. all as per drawing Make: LSI or equivalent in Bajaj, Philips, Halonix
Amoeba light . Divinity Lights AVIVA Type light fixture with PCB mounted back plate with led lamp, System power=96W, 4000K, direct light emission, 230V, option on/off, Dimension:L=1800mm, W= 1200MM, H=90mm. all as per drawing Make : Divinity DLAAPPG1-002 or equivalent in Bajaj, Philips, Halonix
Amoeba light . Divinity Lights AVIVA Type light fixture with pcb mounted back plate with led lamp, System power=5X96W, 4000K, direct light emission, 230V, option on/off, Dimension:L=9000mm, W= , H=90mm. All as per drawing Make : Divinity DLAAPPG1-003 or equivalent in Bajaj, Philips, Halonix
Standard Grey track Electrified track made from extruded aluminium. 6 wires are housed in the track. 4 for three-phase operation, 2 for DALI operation.The wires are enclosed in rigid extruded profiles made of insulating material with high dielectric strength. Length - 3 metre. (Note : For 6 mtrs track, 2 nos 3 mtrs track will be used with 1 no. Power Supply and 1 no Joint and 1 set side caps complete with all accessories) Make : 1. iGuzzini 2. Philips 3 i-LED
Standard track Electrified track made from extruded aluminium. 6 wires are housed in the track. 4 for three-phase operation, 2 for DALI operation.The wires are enclosed in rigid extruded profiles made of insulating material with high dielectric strength. Length - 2 metre. Including 1 no. Power Supply 1 set side caps complete with all accessories) Make : 1. iGuzzini 2. Philips 3 i-LED
Standard track Electrified track made from extruded aluminium. 6 wires are housed in the track. 4 for three-phase operation, 2 for DALI operation.The wires are enclosed in rigid extruded profiles made of insulating material with high dielectric strength. Length - 1 metre. Including 1 no. Power Supply 1 set side caps complete with all accessories) Make : 1. iGuzzini 2. Philips 3 i-LED
Luminaire 70W LED >100lm/w, 5700K fixedIP68Size (mm): ø50x74 CRI>70 Make: 1. Philips BY400V LED 72S CW SY110 PSU S2 FGWH 2. Trilux 3 LED Linear (Lighting Legend in drawing -FL1)
Facade light
Linealuce Direct light luminaire, designed to use monochrome LED lamps. Ground-, wall- and ceiling-recessed with 20W LED 1740lm, 3000K Optic: Wall Grazing Adjustability: fixed Electronic Transformer included IP67 Outer casing L=1640 mm for recessed Linealuce Compact modules L=1658 mm Size (mm): 1658x101x117 Make: 1. iGuzzini BM91+BZV2 2 ERCO 320808 3 WEF 186-8503 (Lighting Legend in drawing -XFR-1)
24 V, 6W/m, 3000K, 380lm/m, flexible opal encapsulated IP67 protected LED light lines with a cross section of 16 x 15 mm (W x H) and vertical bending direction (Top View). 3M self adhesive tape on rear side. Homogeneous and dot free illumination in very low installation depths. 110 mm IP67 plug in connectors on both ends. At maximum length only one side with IP67 plug in connector male, no female connector. Lifetime of > 60,000 hours (L80/B10). rugged design for harsh environments (e. g. resistant to saltwater, UV, chlorine and solvents). Made in Germany Make: 1. LED Linear - Venus TV 1P67 2 iGUZZINI - E 443 3 KKDC - Line Glow - IP 67 (Lighting Legend in drawing -XLL-1)
Recessed luminaire with 5.5W LED 580lm, 3000K Optic: S - Spot 8°Adjustability: fixedIP68Size (mm): ø80x83 Make: 1. iGuzziniE096 2. Erco - 33589.000 3 WE-EF 185-9948 (Lighting Legend in drawing -XUL-1)
Recessed luminaire with 2W LED 195lm, 3000KOptic: SS - SuperSpot 6°Adjustability: fixedIP68Size (mm): ø50x74 Make: 1. iGuzziniE078 2. Erco - 33502.000 3. WE-EF 185-9928 (Lighting Legend in drawing -XUL1A)
iPro Floodlight designed to use 27W LED 2280lm, 3000KOptic: S - Spot 8° adjustability: directional and Electronic Transformer included IP66Size (mm): 192x192x200 Make: 1. iGuzziniBG36 2. Erco 34630.000 3 WE-EF 145-9549 (Lighting Legend in drawing -XSM)
iPro Floodlight designed to use 27W LED 2280lm, 3000KOptic: F - Flood 34°Adjustability: directional with Electronic Transformer includedIP66 Size (mm): 192x192x200 Make: 1 iGuzziniBG38 2. Erco - 34634.000 3 WE-EF 145-9549 (Lighting Legend in drawing -XSM-A) Note: For Srl Item No 12.41 to 12.46 i) Next higher wattage to be installed if specified wattage is not available with the approved manufacturer. ii) Minimum 2 year warranty certificate to be enclosed before release of payment iii) Any make from the list of make (Appendix 'D') shall be approved but equivalent to model/Cat Part No as described in each item. iv) Driver and luminaire shall be of same manufacturer.
M&L for supply and fxing of angle iron clamp duly fabricated from 40x40x6 mm size with 2 nos 16mmx150mm long nuts and bolts including drilling holes for treading for fixing of lighting track to the side and paralled of the truss beam i/c painting complete as directed.
M&L for supply and fxing of angle iron 'L' type clamp duly fabricated from 40x40x6 mm size including drilling holes for fixing of clamp along with beam i/c 6 mm dish fasteners and drilling of holes of size 2mm including threading and machine screws to hold track lighting comlete as directed.
INTERNAL FIRE HYDRANT SYSTEM Note - Complete system of fire fighting, fire detection & fire alarm shall be execuated by a firm dealing with such services. Credentials of firm shall be got vetted by GE.
Supplying & fixing Stainless steel -304 fire hydrant single landing valve with 80 NB flanged inlet, SS spindle controlled 63 mm dia Male instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290 including fixing with anchor fastner and flanged tapping from wet riser and Supplying pressure gauge with gun metal ball valve, complete all as specified and directed. Cost:- The cost of pressure gauge with gun metal ball valve shall be deemed to be included in this item.
Supplying & fixing swinging type First Aid hose reel in red colour drum with 36 mtr long and 20 mm dia heavy duty thermoplastic Hose (Textile Reinforced) Type-2 water hose, 20 mm dia globe valve stop cock, terminating with SS coupling & brass with chromium plated nozzle of 6mm outlet with shut off valve conforming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:12585, complete all as specified and directed.
Supplying & fixing non-perlocating, rubber reinforced lined fire hose pipe (as per IS : 636, Type A) of 63 mm dia and 15 m length. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & rivetted to hose pipe with SS rivets & 1.5 mm SS wire (Location : Internal fire hydrant), complete all as specified and directed.
Supplying and fixing 63 mm dia instantaneous pattern branch short Stainless steel-304 pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling, complete all as specified and directed.
Supplying and fixing standard firemans axe with heavy rubber of specification not less than 300mm in length, cutting edge 90mm and weight 600gm IS 926 Marked, complete all as specified and directed.
Supplying and fixing lockable fire hose cabinet of size 2100 mm x 900 mm x 350mm made out of SS-304 sheet of 16 gauge thickness having center opening and 5 mm thick glazed glass door. Suitably marked on the outside with the letters "FIRE HOSE" including looking arrangement with keys, complete all as specified and directed.
Supplying and fixing lockable cabinet of size not less than 750 x 600 x 250 mm made out of SS-304 sheet of 16 gauge thickness having central opening and 5 mm thick glazed glass doors (Two nos.) ,Supplying break glass box containing key for the cabinet along with hammer suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement. The cabinet shall be accommodate 2 Nos of 15 mtr long Hose pipe & 1 No of branch pipe nozzle. It shall be mounted on SS-304 supporting angle/circular section of 1 mtr height with proper arragement complete as required, complete all as specified and directed. Note: Cost of Hose Pipe and Branch pipe to be measured & paid separately.
Supplying and fixing orifice plate made out of 6 mm thick stainless steel 316 grade with orifice of 80 mm dia in between flange & landing valve, the pressure should not exceed between 5 kg/cm2 to 7 kg/cm2, complete all as specified and directed.
Supplying and fixing of 100 mm dia C.I. Dual plate NRV(non-return valve) with flanges, Nut, bolts & washers, painting etc. (suitable for test pressure of 16 kg / cm2), complete all as specified and directed.
Supplying, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200mm in diameter and 1.2 meter in height with dished end fabricated from 8mm thick MS plate with 25mm dia auto air vent valve (PN1.6) on top with ball valve, flanged inlet connection and drain arrangement with 25mm dia drain valve, pressure gauge with gun metal stop cock complete with all accessories and conforming to IS 4736-1968, complete all as specified and directed.
Supplying, fixing, testing & commissioning of 25 mm dia auto air vent valve (PN-16) on top of each sprinkler riser with ball valve, flanged inlet connection etc, complete all as specified and directed.
Supply, Installation, Testing and Commissioning of electric driven, Split Casing/end suction centrifugal pump of cast iron body, bronze impellers with carbon steel shaft & mechanical seal directly coupled with TEFC SQ cage foot mounted type induction motors suitable for operation on 3 phase, 415 volts 50 Hz AC supply with IP 55 protection for enclosure with F class insulation conforming to IS: 325 including common base frame fabricated from min. 75X50 mm M.S channel, coupling with guard foundation bolts, pressure gauge, anti-vibration pads including electrical control panel with necessary switchgear, cabling pressure switch for automatic operation of pump with incase of low pressure, cement concrete foundation etc, complete all as specified and directed. Pump shall be CED coating.(Terrace pump) Flow : 450 LPM Head :35 mts RPM: 2900
SPRINKLER SYSTEM Supplying, laying, jointing and testing of following sizes of Mild steel `C' Heavy class pipes conforming to IS-1239 & IS:3589 with all accessories like all fittings ( for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers (using anchor fastners) as per specification. G.I pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors,two coat of primer paint and sealing the sleeves with glass wool in between & fire sealent compound at either end all as directed requirements including cutting holes in brick, R.C.C work and making good the same to original conditions complete in all respects. including two coat of synthetic enamel paint of approved shade over a coat of primer to following sizes of pipes prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc.including painting of legends both direction of arrow, complete all as specified and directed. Note : The item required for wet riser System shall be measuered and paid for under these items.
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying & fixing of following size cast iron butterfly valve, with flanges, nut bolts & gaskets complete required. Butterfly valve shall be with pad locking arrangement (suitable for test pressure of 16 kg / cm2), complete all as specified and directed. Note : The item required for wet riser System shall be measuered and paid for under these items.
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying & fixing brass quartzoid sprinklers of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows :(UL LISTED)(K - 8.0)( 175 PSI), complete all as specified and directed.
upright type sprinkler (68 deg.C) quick response type.
Pendent type sprinkler (68 deg.C) quick response type.
Sidewell extended coverage (68 deg.C) sprinkler standard response type.
Supplying and fixing of chrome finish double rossettle plate for pendant sprinkler, complete all as specified and directed.
Supplying and fixing following size electrically operated water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NONC, complete all as specified and directed.
65 mm dia
100 mm dia
150 mm dia
Supplying and fixing 50 mm dia inspectors test assembly with built in test valve, sight glass, sectional drain valve, union with corrosion resistant orifice, complete all as specified and directed.
Supplying, fixing, testing & commissioning of 25 mm dia auto air vent valve on top of each sprinkler riser with stop cock, flanged inlet connection, complete all as specified and directed.
Supplying and fixing of 150 mm dia C.I. dual plate NRV (non-return valve) with flanges, Nut, bolts & washers, painting (suitable for test pressure of 16 kg / cm2), complete all as specified and directed.
Supplying & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of Supplying any short pieces, nipples, elbows etc, complete all as specified and directed.
PORTABLE FIRE EXTINGUISHERS
Supply and installation of following types of extinguisher with provision of wall bracket (fixed with anchor fastner), complete all as specified and as directed.
Water CO2 Stored Pressure type Fire Extinguisher, filled with 9 Litre capacity Fire Extinguishers. The Extinguisher will be as per BIS: 15683 bearing ISI mark, complete with all accessories, complete all as specified and as directed.
ABC Stored Pressure type Fire Extinguisher filled with 6 Kg capacity bearing ISI Mark for Fighting ABC Class of Fire. The Extinguisher will be as per BIS: 15683 bearing ISI mark, complete with all accessories, complete all as specified and as directed.
Co2 type Fire Extinguisher filled with 4.5 Kg Capacity, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge . The Extinguisher will be as per BIS: 15683 bearing ISI mark, complete with all accessories, complete all as specified and as directed.
Co2 type Fire Extinguisher filled with 3 Kg Capacity, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge . The Extinguisher will be as per BIS: 15683 bearing ISI mark, complete with all accessories, complete all as specified and as directed.
Mechanical Foam Stored Pressure Type filled with 9 Litre capacity Fire extinguisher. The Extinguisher will be Manufactured Strictly as per BIS: 15683 bearing ISI mark, complete all as specified and as directed.
Supply and Installation of Trolley mounted type Fire extingusher dry chemical power (ABC) type Fire Extinguisher,with capacity of filled with 25 kg, commplete accesaries, as per IS: 10658, complete all as specified and as directed.
Supply and Installation of Trolley mounted Fire extingusher water mist type Fire Extinguisher,with capacity of filled with 50 liters capacity, commplete accesaries, as per IS: 13385, complete all as specified and as directed.
Supply and Installation of Trolley mounted Mechanical Foam type filled with 50 liters. Capacity Fire Extinguisher, fitted with gunmetal cap, discharge hose with foam making branch pipe, mounted on rubber tired wheels, complete with initial charge of AFFF concentrate (6% 3 Liters.) and fully charged Gas Cartridge 300 Grams. Charged weight of the extinguisher 100 kgs approximately. Suitable for class ‘B’ type fire INTERNAL GAS CARTRIDGE TYPE Bearing ISI Mark conforming to IS: 13386, complete all as specified and as directed.
Supply and Installation of Trolley mounted type CO2 Fire Extinguisher, with capacity of filled with 22.5 kg, commplete accesaries, as per IS: 2878, complete all as specified and as directed.
FIRE DETECTION & EMERGENCY EVACUATION SYSTEM
Supply, installation, testing and commissioning of plug-in type intelligent addressable photo-thermal multi criteria detectors including base plate, mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of plug-in type fixed temperature intelligent addressable Heat detectors including supplying base plate, mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of plug-in type intelligent analogue addressable rate of rise cum fixed temperature Heat detectors including base plate, 75 mm dia M.S. outlet box for fixing of the detector base, mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of plug-in type intelligent analogue addressable laser detectors including base plate, mounting accessories etc, complete all as specified and directed.
Supply installation, testing and commissioning of Network panel (Fire Alarm Capability: 1 Loop x 100/125/150 detectors & 100/125/150 devices) wall recess mounting microprocessor based networkable analogue addressable Fire Control Panel expandable by minimum 1 additional loops with minimum 80 character LCD display, 4 access levels, 1000 events historical logging, flash E-PROM, 240 volts ac power supply, automatic battery charger, 24V sealed lead-acid battery suitable operating the system for 2 hours of Alarm and 6 hours of standby. The Panel shall be Integrated with the PA System and with suitable power amplifiers for hooter/strobes. The Panel shall be suitable for Integration with the BMS System and shall include any additional modules, software and interfaces as required, complete all as specified and directed.
Supply installation, testing and commissioning of Network panel (Fire Alarm Capability: 4 Loop x 100/125/150 detectors & 100/125/150 devices) wall recess mounting microprocessor based networkable analogue addressable Fire Control Panel expandable by minimum 1 additional loops with minimum 80 character LCD display, 4 access levels, 1000 events historical logging, flash E-PROM, 240 volts ac power supply, automatic battery charger, 24V sealed lead-acid battery suitable operating the system for 2 hours of Alarm and 6 hours of standby. The Panel shall be Integrated with the PA System and with suitable power amplifiers for hooter/strobes. The Panel shall be suitable for Integration with the BMS System and shall include any additional modules, software and interfaces as required, complete all as specified and directed.
Supply, installation, testing and commissioning of the manufacturer provided GUI Software Workstation for complete interactive control of the Fire Alarm System and interface with Fire Panels as per item no. 17.50 & 17.60 above. The Workstation shall provide “Take Action” messages to first responders with specific, real-time information about alarms at the site including notes about hazardous materials, vulnerable building occupants, and management contacts, Upload/download configuration files without taking the whole system off-line and shall have auto-watch option to allow the operator to automatically scan individual buildings, The Software shall be networkable with a multi-user option/client & server configuration shall include the following, complete all as specified and directed. Desktop computer Intel Core 2 Duo Processor, 2GB DDR2 RAM, 320 GB Hard Disc Drive, with out optical drive, 18.5” TFT Monitor, Ethernet, Keyboard and mouse, HP A3 Size Colour Inkjet Printer, Windows XP/Vista/7 OEM with licensed windows OS.
Supply, installation, testing and commissioning of dust and vermin proof addressable analogue Manual Pull/call stations including all required modules, mounting accessories etc with in-built isolator module in either detector or in base, complete all as specified and directed.
Supply, installation, testing and commissioning of addressable Zone Adaptor Module/Monitor Module for connecting conventional devices, complete all as specified and directed.
Supply, installation, testing and commissioning of Intelligent addressable Control Modules including all mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of Intelligent addressable Relay Modules including all mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of Intelligent addressable Fault Isolator Modules including all mounting accessories, complete all as specified and directed.
Supply, installation, testing and commissioning of recess/surface mounting intelligent analogue addressable Talk Back Jacks with stainless steel face plates for connections of Fireman's handsets including all the required modules, mounting accessories, complete all as specified and directed.
Supply installation testing and commissioning of two way Talk Back handsets to initiate audio interface, complete all as specified and directed.
Supply, installation, testing and commissioning of wall or ceiling mounted 240 Volt AC illuminated double sided pictorial exit signs provided with appropriate direction arrow painted in green on white with an 3W LED Lamp including in-built rechargeable batteries, charger and Driver suitable for 90 minute operation and including accessories for surface/ recessed or ceiling suspended mounting, complete all as specified and directed.
Supply, installation, testing and commissioning of Network Repeater panels as per item No. 17.50 & 17.60 here-in-above, complete all as specified and directed.
Supply, installation, testing and commissioning of intelligent addressable electronic high intensity hooters cum strobes/flashess suitable for recess/surface mounting complete with all mounting accessories etc, complete all as specified and directed.
Supply, installation, testing and commissioning of intelligent analogue addressable Beam detectors including of wall mounted base plates for the transmitter and receiver units and including aligning and configuring alongwith mounting accessories etc., complete all as specified and directed.
Supply, installation, testing and commissioning of metal casing wall/ceiling mounted type. 3W, 8 OHM speaker with line, complete all as specified and directed.
Supply, Installation, Testing and commissioning of analogue addressable directional sounder cum Strobe Lights of intensity as required. The strobes shall be synchronized for providing directional evacuation and include the cost of any additional modules if required, M.S. outlet box for fixing of the hooter cum strobe, mounting accessories etc., complete all as specified and directed.
Supply, installation, testing and commissioning of MS Amplifier Rack Assembly with 30 minutes power backup including 1 no. CD player unit, 2 nos 1000 W POWER AMPLIFIER (1 nos Main & 1 no. Standby), connectors, internal wiring, interconnection etc capable of voice operated priority complete as directed. (PA System fully integrated type with Fire Alarm System with facility for automatic override of music for emergency announcements) ANALOG system, complete all as specified and directed.
Supply, installation, testing and commissioning of Microphone with table stand, complete all as specified and directed.
Supply, laying, testing and commissioning of 2C x 1.5 sqmm copper conductor PVC insulated steel strip or wire armoured and overall PVC sheathed insulated cables in existing conduiting system as required and including the cost of crimped termination's, complete all as specified and directed.
Supplying and fixing heavy duty conforming to IS-9537 ISI embossed black enameled MS recessed and/or surface conduits including saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting of following sizes, complete all as specified and directed.
20 mm dia 16 SWG
25 mm dia 16 SWG
32 mm dia 16 SWG
Supply and fixing MS flexible conduit including all fittings complete as directed and of following sizes
20 mm dia 16 SWG
25 mm dia16 SWG
32 mm dia16 SWG
Supplying, laying, connecting, testing and commissioning of 4C x 1.5 sq.mm Fire Survival armoured cable (600/1000V) with copper conductor having Cross-linkable (LSZH) insulation & LSZH inner and outer sheath as per BS 7846:2009, complete all as and directed.
EXTERNAL FIRE FIGHTING
FIRE PUMPS & EQUIPMENTS
Supply, Installation, Testing and Commissioning of Factory Assembled Electrically Driven high pressure centrifugal fire hydrant /sprinkler pump, suitable for automatic operation consisting of the following : a) Horizontal, Split Casing centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (410) Shaft & Sleeve with mechanical seal, capable for delivering 2850 LPM at outlet head of 90 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or top most hydrant . The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. Pump shall be CED coated b) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. c) Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C supply, for the above pump with synchronous speed of 1400-1500 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required. d) Common base plate for (a) and (c) from M.S. Channel for required size. e) Suitable cement concrete foundation with plaster and MS angle epoxy coated edging complete with antivibration arrangement of cushy foot mountings.
Supply, Installation, Testing and Commissioning of Factory Assembled Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date. a) Horizontal, Split Casing centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (410) Shaft & Sleeve with mechanical seal, capable for delivering 2850 LPM at outlet head of 90 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. Pump shall be CED coated. b) Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. c) Heat exchanger cooled diesel engine of speed 1400 to 2100 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. of maintenance free 180 AH ,12 volt battery(as per pump model), flexible coupling, coupling guard & exhaust pipe connection complete as specified. d) Common base plate for (a) and (c) from M.S. channel of required size. e) Suitable cement concrete foundation with plaster and MS angle epoxy coated edging complete with antivibration arrangement of cushy foot mountings.
Supplying, installation, testing and commissioning of jockey pumps comprising of the following: a) Vertical Multistage centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete as required. b) The pump shall be complete in SS-304 casing,impeller & shaft. The pump shall be provided with mechanical seal The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. c) Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as required. d) Common base plate for (a) and (c) from M.S. channel as required size. e) Suitable Antivibration arrangement of cushy foot mounting. f) Suitable cement concrete foundation with plaster and MS angle epoxy coated edging complete with antivibration arrangement of cushy foot mountings. For pump defined above & of duty as follows : Flow : 180 LPM Head :90 mtr
Supplying & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine as described at srl item No 20.20 above. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope (150 mm dia or as per engine model), complete all as specified and directed.
Supplying, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 2000 mm height) made of MS sheet 10mm thick, for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required, complete all as specified and directed.
Supplying and fixing following size of heavy class MS suction & delivery headers of required length as directed conforming to IS:3589 with welded joints standard MS Fittings and with end flange connections having inlet & outlet flanged connections including GI supports from wall, floors & ceiling complete as required, Inculding two coat of paint over a coat of primer. Cost should be inclusive of all supports / clamps / brackets, anchor fastner etc. as required (all in GI), complete all as specified and directed.
300 mm dia ( 6 mm thick)
250 mm dia ( 6 mm thick)
Supplying, fixing, testing and commissioning of black steel IS; 1239 and 3589 marked Class "C" M.S pipe including all fittings (heavy class) i.e bend, tee, elbow, reducing socket, flanges, nuts & bolts etc. fixed with screwed or welded joints, hanged with clamps, hanger supports, dash fasteners, bolts, nuts, rubber insertion etc using Grooved Couplings and Fittings (FM Approved / UL Listed) with including Grooving, cutting, edge preparation, cutting & making good the wall/ floor wherever required including two coat of synthetic enamel paint of approved shade over a coat of primer to following sizes of pipes prior to application of primer the surface should should be cleaned for any dirt, rusts, rough substance etc. including painting of legends both direction of arrow complete in all respects, complete all as specified and directed.
Supplying, fixing, testing and commissioning of C.I Sluice valve OS&Y type (suitable for test pressure of 16 kg / cm2) with flanges, nut bolts, gaskets,washer etc ,of following sizes, complete all as specified and directed.
Supplying, fixing, testing and commissioning of C.I.dual plate NRV (non-return valve)with flanges, Nut, bolts & washers, etc. (suitable for test pressure of 16 kg / cm2) of following sizes, complete all as specified and directed.
Supplying, fixing, testing and commissioning of double flanged flexicon rubber expansion joint (suitable for system pressure) of standard length as per manufacturer specifications including rubber gaskets, flanges, nuts, bolts and washers etc. of following sizes, complete all as specified and directed.
Supplying, fixing, testing and commissioning of 200mm dia C.I Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and washers etc., complete all as specified and directed.
Supply, installation, testing and commissioning of sight tube (of 3.5 to 4 meter length) with isolation valve at top / bottom, demarcation on tube for making the installation of level indication on the RCC water tank, complete all as specified and directed.
Supplying, testing & commissioning of dial type pressure gauge with pressure scale of 0 to 20 kg / cm2. Provision of isolation cock suitable for maximum pressure of 20 kg/cm2 shall be included in cost.(delivery header only), complete all as specified and directed.
Supplying, fixing, testing and commissioning of 150mm dia installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications, complete all as specified and directed.
Supplying and fixing 25 mm x 3 mm GI strip on surface or in recess for connections etc, complete all as specified and as directed. Note: i) Brazing/welding shall be done between joint in strip with in overall cost quoted by the contractor. ii) Strip shall be installed and fixed over insulators along wall, floor and roof with in overall cost quoted by the contractor.
Supplying and fixing 6 SWG GI wire on surface or in recess for loop earthing alongwith existing surface/recessed conduit/submain wiring/ cable etc, complete all as specified and as directed.
Supplying and fixing of following sizes of perforated MS cable tray including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required duly suspended from the ceiling with MS Suspenders and including painting with post office red synthetic paint, complete all as specified and as directed.
150mm (W) x 50mm (D) x 1.6mm (T)
300mm (W) x 50mm (D) x 1.6mm (T)
M & L for GI strip of size 50x6mm as earth continuity conductor buried in ground or drawn in conduit/ pipe of fixed to pole or any other indicated situation for loop earthing as required, complete all as specified and as directed. Note: i) Brazing/welding shall be done between joint in strip with in overall cost quoted by the contractor. ii) Strip shall be installed and fixed over insulators along wall, floor and roof with in overall cost quoted by the contractor.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable in trenches complete all as specified and directed. Note: punned thickness of sand only shall be measured.
M&L for cover to underground cable with one layer of bricks using sub class ‘B’ bricks (Old size) laid flat across the cable complete all as specified. (Note: Excavation and earth work shall be measured separately).
M &L for chemical earthing with copper earth plate electrode 90cm x 60cm x 6 mm thick buried directly in ground vertically at a depth not less than 4.5 metre below normal ground level with top edge of earth plate at a depth not less than 10 feet below normal ground level, earth plate surrounded from all sides upto 5 feet with ground enhancing material (GEM) and electrode connections by using copper strip of 50x6 mm as earthing lead (upto the test point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 65mm dia GI pipe and including test point made of copper strip and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m, complete all as specified in IS 3043, electric plate No 3 and as directed. Note: i) Cost of earth work is included in overall rate quoted by the contractor. ii) Resistance value of the earthing system shall be less than 1 ohm and value must be submitted by the contractor before payment is release.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal ground level and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of glavanized iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron pipe light grade 15 mm bore and watering pipe 20mm dia medium grade with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B - 1 in chamber and 80 mm thick precast RCC 1:2:4 type B - 1 using XPM weighing not less than 4Kg/Sqm for cover slab/coping, complete all as specified in IS 3043, electric plate No 3 and as directed. Note:- The GI earth strip & light grade GI pipe upto 7.5 M deemed to be included in the rate quoted by the contractor. Beyonnd 7.5mm GI earth strip and GI tubing light grade shall be measured and paid under the respective item of schedule all as specified and as directed by the Engr-in-Charge.
Supplying, fixing, testing and commissioning of Pressure switch suitable for 12 Kg/cm2, complete all as specified and as directed.
EXTERNAL FIRE HYDRANT SYSTEM
Supplying, laying, jointing and testing in trenches the following sizes of MS class `C' (heavy class) pipes conforming to IS:1239 & IS:3589 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including MS pipes and fitting by applying pypkote primer @ 100 gm/sqm). Thereafter wrapping 4 mm thick pypkote (AW4mm) protection coating by thermo fusion process. Overlap shall be maintained at 20 mm including sand cushioning 50mm all around the pipe in trenches. The application shall be strictly as per manufacturers’ specificaitons, complete all as specified and as directed. Note - Excavation and earth works shall be measured & paid seperately.
80 mm dia
100 mm dia
150 mm dia
For External Hydrant System - MS `C' Heavy class pipe Supplying, laying, jointing, testing and commissioning of of following sizes of pipe confiroming to IS-1239 with all accessories like all fittings(standard MS fitting with welded jointshall be used on the pipes) including tees, elows, reducers, union, flanges, rubber gaskets, GI nuts, bolts, washer etc. including two coat of synthetic enamel paint of approved shade over a coat of primer to following sizes of pipes prior to application of primer the surface should should be cleaned for any dirt, rusts, rough substance etc. including painting of legends both direction of arrow, complete all as specified and as directed.
80 mm dia
100 mm dia
150 mm dia
Supplying & fixing of following size cast iron butterfly valve, with flanges, nut bolts & gaskets complete as required. Butterfly valve shall be with pad locking arrangement (suitable for test pressure of 16 kg / cm2), complete all as specified and as directed.
80 mm dia
150 mm dia
Supplying & fixing Stainless steel- 304 fire hydrant single landing valve with 80 NB flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. Including fixing with anchor fastner and flanged tapping from main fire ring, complete all as specified and as directed.
Supplying and Fixing 63 mm dia instantaneous pattern branch short Stainless steel -304 pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling, complete all as specified and as directed.
Supplying & fixing of 15 m length non-perlocating, rubber reinforced lined fire hose pipe (as per IS : 636, Type A) of 63 mm dia and length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & rivetted to hose pipe with SS rivets & 1.5 mm SS wire, complete all as specified and as directed.
Supplying & fixing of External Hose Box, wall mounting double door type, made out of FRP, 32” x 24” x 10” size, thickness of FRP sheet shall be 2.5 mm,front window with 3 mm Thick polycarbonate,brass handle, hinges S.S - 304, brass key, MS Galv. nozzle clamp etc to accommodate two 15m length of delivery hose and branchpipe.Internally & Externally Painted with fire red color including fixing arrangement as per manufacturer recommendation/instructions, required at site and approved by GE, complete all as specified and as directed. Note - Cost of two nos. 15 mtr hose pipe & branch pipe shall be measured seperately.
Supplying & fixing of Gun metal fire brigade connection consisting of 4 Nos. 63 mm dia instantaneous type male couplings complete with built-in check valves, 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required and as per IS:904-1963(For tank filling), complete all as specified and as directed.
Supplying & fixing Gun metal fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS: 902-1974 complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (2Nos) (I/C GI pipe & foot valve to be included), complete all as specified and as directed.
M & L for constructing of brick masonary chamber Size 1200 x 900 x 1000 mm deep (for housing valve) in brick work with bricks of class 75 in cement mortar 1:5 (1 cement:5 fine sand) 12 mm thick plaster on inside with a floating coat of neat cement &rough plaster on external faces with cement mortar 1:3 (1 cement : 3 coarse sand. Including Supplying R.C.C. top slab complete in all respect. Cost shall be inclusive of excavation in earth, shoring, dewatering, support to valve and access rungs as required to complete the work, complete all as specified and as directed.
Supplying & fixing SFRC heavy duty manhole cover with frame of 560 mm internal dia for valve chamber, complete all as specified and as directed.
Supplying and fixing 80 mm dia orifice plate made out of 6 mm thick stainless steel 316 grade with orifice of required sizes in between flange & landing valve,the pressure should not exceed between 5 kg/cm2 to 7 kg/cm2, complete all as specified and as directed.
Supplying & laying cement concrete for thrust block of 1:4:8 (1 cement : 4 fine aggregate : 8 coarse aggregate), 40mm nominal size, complete all as specified and as directed.
Supplying and fixing of 150 mm dia cast iron dual plate NRV (non-return valve)with flanges, Nut,bolts & washers, painting complete as directed (suitable for test pressure of 16 kg / cm2), complete all as specified and as directed.
SEWAGE DISPOSAL
S&F stoneware gully trap 300 x 300mm chamber with 1No.100 x 100mm size `P' trap with C.I. grating embedded in brick masonary chamber of standard design with first class bricks and trap to be set in cement concrete 1:2:4, both side 12mm thick plastering with floating coat of neat 'cement. Making necessary connections & providing water tight C.I. cover with frame of 300mm x 300mm internal size. The weight of cover to be not less than 4.5 kg & frame not be less than 2.7 kg as per standard design. Including necessary excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same, complete all as specified and directed.
Supplying and fixing stoneware gully trap of 900 x 800mm chamber with 3 No's100 x 100mm size `P' trap with C.I. grating embedded in brick masonary chamber of standard design with first class bricks and trap to be set in cement concrete 1:2:4, both side 12mm thick plastering with floating coat of neat 'cement. Making necessary connections & providing water tight including SFRC cover with frame (Light Duty) 450x600mm internal dimensions.Including necessary excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required.
AREA DRAINAGE/STROM WATER DRAINAGE
Supply, Laying and testing of following size of non-pressure RCC Pipes NP2 class (light duty) with single socket jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) laid in trenches etc, Complete all as specified and directed.
500 mm dia
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in concrete bed to drain pipes of following bore including packing under and hunching against the side of pipe after they are laid and tested, complete all as specified and directed.
500mm dia
600mm dia
Constructing brick masonary road gully chamber 50x45x40 cm deep average brick work in cement motor (1:4) with F.P.S brick of class designation 75, including 500x450mm perforated DI heavy duty horizontal grating with frame, necessary excavation and earth work in any type of soil , returning filling in approved soil, disposal of surplus soil to a distance not exc.50 mtr, PCC in foundation, 15mm thick plaster in cement mortar 1:4 internally and externally flush pointed in same mortar as the work proceeds, complete as per standard design, all as specified and directed.
S&F Medium Duty-10MT, SFRC manhole cover with frame size 450 x 600 mm, test load as per (IS-12592 Part 1), complete all as specified and direcetd.
Providing safety foot rest of approved colour and of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per design, complete all as specified and directed. Note: The items required for "Sewage Disposal and External Water Supply Schedules" shall be measuered and paid for under these items.
Providing and laying 250mm thick (compacted thickness) Granular Sub-base (below the plinth) by providing close graded material conforming to Grade-III (size range 26.5mm to 0.075 mm) having CBR Value-20 conforming to specifications, mixing in a mechanical mix plant at OMC, including carrying the mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of suitable capacity to achieve the desired density, complete all as specificed and directed.
Providing of pre-cast factory made RCC cover slabs for drains, gratings etc. in M-30 Grade including shuttering but excluding reinforcement in any size and thickness all casting arrangements like casting beds, stacking yard, etc., all necessary shuttering and formwork, curing, lifting and transportation from casting beds, Stacking yards, erection to the required heights and locations, alignment, leveling and fixing of units wherever required, in-situ welding/temporary supports for fixing the units, scaffolding/ staging, grouting of joints with 1:1 cement sand grout etc. , complete all as specified & shown on drawing and as directed. Note : i) Reinforcement steel, inserts, pipe embedment, etc. shall be measured and paid separately. ii) The items required for "Sewage Disposal" will be measuered and paid for under these items.
EXTERNAL WATER SUPPLY
Supply, laying, jointing and testing of following sizes of ductile iron pipe class K9 with spigot and socket ends centrifugally cast suitable for tyton jointing (push on rubber gasket), complete as per IS:8329, laid in trenches, complete all as specified & directed. Note: The items required for "Sewage Disposal and Area Drainage/Strom Water Drainage" shall be measuered and paid for under these items.
S&F ductile iron fittings for spigot and socketed/flanged pipes any bore such as bends (any type, radius and angle), Taper any type, (straight, bend, increasing, decreasing or double socket etc.), Tee pieces, single branch, `Y’ Junction, double branch, cross (all sockets or socket and spigot), collar, caps and plugs, complete all as specified and directed. Note: The items required for "Sewage Disposal and Area Drainage/Strom Water Drainage" shall be measuered and paid for under these items.
M&L for brick masonary valve pit of size 60 cm x 60 cm x 60 cm (internal dimension of chamber ) depth of chamber to be reckoned from the top of PCC in foundation to top the MS cover as 60 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 6 mm with fixing arrangement, hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame, necessary excavation and earth work in any type of soil , returning filling in approved soil, disposal of surplus soil to a distance not exc.50 mtr, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, brick work in cement motor (1:4), 15mm thick plaster in cement mortar 1:4 internally and externally flush pointed in same mortar as the work proceeds, 40 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, complete all as specified and as shown on drawing and directed. Note: The items required for "Sewage Disposal " shall be measuered and paid for under these items.
M&L for brick masonary valve pit of size 90 cm x 90 cm x 90 cm (internal dimension of chamber ) depth of chamber to be reckoned from the top of PCC in foundation to top the MS cover as 90 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame, necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, brick work in cement motor (1:4), 15mm thick plaster in cement mortar 1:4 internally and externally flush pointed in same mortar as the work proceeds, 40 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, complete all as specified and as shown on drawing and directed. Note: The items required for "Sewage Disposal " shall be measuered and paid for under these items.
Supplying, fixing, testing & commissioning of Factory Fitted pressure boosting system in accordance with DIN-1988 skid mounted Variable speed hydropneumatic system, ready for connection with pipe work mounted with electroytic galvanised base frame with height adjustable vibration absorbers. The system comprising of :- Vertical, inline multistage centrifugal pumping set with stainless steel SS 304 stage casing and SS 304 impellers with SS 316 shaft and suction and discharge casing shall be CI with CED Coating connected to TEFC ventilated induction motor of 2 pole, 2900 rpm, suitable for 415 Volts ± 10 % 3 phase, 50 HZ AC Supply. MS Epoxy coated bladder vessel with replaceable bladder arrangement for water Supplying pumps siutable for the specified working pressure; Complete with a control cabinet, motor protection, integrated controller and dedicated VFD for each motor, a pre-assembled and tested systems with suction & discharge manifolds in galvanised iron heavy duty pipes for water Supplying pumps, isolating valves, non-return valves, pressure gauges, Air release Valves,2 nos pump with motor & pressure transmitter. All the pump shall operate on VFD, when the system pressure reduces to the preset point. If demand escalates, the lag pumps shall commence operation on DOL as required. The system shall vary the frequency to ensure smooth operation to meet the specific demand. Under decreasing hydraulic demand, the reverse to the above description shall apply. The controllers will have following functions :- The System offers the following functions: Loop control On/Off Operation at low flow Automatic Cascade control of Pumps Automatic Pump change
Supply, fixing, testing & commissioning of Factory Fitted pressure boosting system in accordance with DIN-1988 skid mounted Fixed speed hydropneumatic system,ready for connection with pipe work mounted with electroytic galvanised base frame with height adjustable vibration absorbers. The system comprising of: Vertical, inline multistage centrifugal pumping set with stainless steel SS 304 stage casing and SS 304 impellers with SS 316 shaft and suction and discharge casing shall be CI with CED Coating connected to TEFC ventilated induction motor of 2 pole, 2900 rpm, suitable for 415 Volts ± 10 % 3 phase, 50 HZ AC Supply. Complete with a control cabinet, motor protection, integrated controller & pre-assembled and tested systems with suction & discharge manifolds in heavy duty galvanised iron pipes , isolating valves, non-returns valves, pressure gauges, Air release Valves, 2 nos pump with motor & pressure Switch. All the pump shall operate on Full Rpm, when the system pressure reduces to the preset point. If demand escalates, the lag pumps shall commence operation on DOL required. The system shall Start another Pump to meet the specific demand. Under decreasing hydraulic demand, the reverse to the above description shall apply. The controllers will have following functions :- The System offers the following functions: Loop control On/Off Operation at low flow Automatic Cascade control of Pumps Automatic Pump change Manual Operation - There are two modes of operation namely: Manual Mode Auto mode
Supplying, Installation , Testing & commissioning of End suction Back pull out type Monobloc centrifugal pumping set. Casing shall be CI with CED Coating and Bronze impellers with stainless steel SS 316 shaft as per IEC standards connected to TEFC ventilated induction motor of 2 pole, 2900 rpm, suitable for 415 Volts ± 10 % 3 phase, 50 HZ AC supply, complete with Heavy Duty GI Suction and delivery header with butter fly valve PN 10 with SS 316 grade disc, dual plate CI NRV PN10 with SS plate,prssure gauge, 2 nos pump with motor etc.Complete set system to be mounted on a common base frame of following duty. Suitable cement concrete foundation with plaster and MS angle epoxy coated edging complete with antivibration arrangement of cushy foot mountings. Following pumps are also included in overall cost quoted Filter Feed Pump for Filtration & Softning Each pump Capacity: 300 LPM,Head : 30 Metre Each pump KW : 5.0 (Approx.) or as required. Qty :2 nos (1w+1sb) Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model LBI 11L
Supply, Installation , Testing & commissioning of End suction Back pull out type Monobloc centrifugal pumping set. Casing shall be CI with CED Coating and Bronze impellers with stainless steel SS 316 shaft as per IEC standards connected to TEFC ventilated induction motor of 2 pole, 2900 rpm, suitable for 415 Volts ± 10 % 3 phase, 50 HZ AC supplying complete with Heavy Duty GI Suction and delivery header with butter fly valve PN 10 with SS 316 grade disc, dual plate CI NRV PN10 with SS plate,prssure gauge, Starter Panel , Power cable , control cable , earthing etc.,2 nos pump with motor as required .Complete set system to be mounted on a common base frame of following duty.(RV Area transfer Pump for museum block( Domestic Supply) Suitable cement concrete foundation with plaster and MS angle epoxy coated edging complete with antivibration arrangement of cushy foot mountings. Following pumps are also included in overall cost quoted Each pump Capacity: 400 LPM,Head : 50 Metre Each pump KW : 10.0 (Approx.) or as required. Qty :2 nos (1w+1sb) Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model LBI 31
Note For sr.no. 27.60 to 27.90:- .a) Cost of PCC foundations as per recommendation of manufacture is included in overall cost quoted. B) Head calculations for pump sets shall be submitted by contractor for approval of GE. However, no price adjustment shall be done if head varies upto +5 mtr.
Supply, installation , testing & commissioning of submersible pumps for suitable rating, with non-clog free flow open CI impeller, CI casing, SS-410 shaft , Pumps shall be provided with lifting chain. Pump should be capable on operation on 415 Volts ± 10 % 50 HZ A.C 3 phase supply.The pump shall be CED coated. The above pump sets must be supplied complete with following accessories:- Necessary cables from pump set to control panel -- 1 Set Electrical switch panel having all necessary accessories & safety devices of standard specifications. Panel shall be suitable for both pump work at time. (Panels with sump pumps near each sump as per site conditions) -1 No. Automatic built-up water level controller with necessary length of cable upto control panel. 80 mm dia C.I Butterfly valve (PN-1.0) - 2 Nos 80 mm dia C.I. Dual plate check valves (PN-1.0) - 2 Nos Each pump Capacity: 10.0 m3/hr, Head : 12 Metre Each pump KW : 1.5 (Approx.) or as required. Solid handling : 10 to 12 mm Quantity : 2 Nos. (1W+1SB) (Pump Room) Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model LAP 21A35
Supplying, installation , testing & commissioning of submersible pumps for suitable rating, with non-clog free flow open CI impeller, CI casing, SS-410 shaft , Pumps shall be provided with lifting chain. Pump should be capable on operation on 415 Volts ± 10 % 50 HZ A.C 3 phase supply. The pump shall be CED coated. The above pump sets must be supplied complete with following accessories:- Necessary cables from pump set to control panel - 1 Set Electrical switch panel having all necessary accessories & safety devices of standard specifications. Panel shall be suitable for both pump work at time. (Panels with sump pumps near each sump as per site conditions) -1 No. Automatic built-up water level controller with necessary length of cable upto control panel. 200 mm dia C.I Butterfly valve (PN-1.0) - 2 Nos 200 mm dia C.I. Dual plate check valves (PN-1.0) - 2 Nos Each pump Capacity: 175 m3/hr, Head : 12 Metre Each pump KW : 15.0 (Approx.) or as required. Solid handling : 10 to 12 mm Quantity : 2Nos. (1W+1SB) (Display roof area rain Water drainage) Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model LHP 61535
Supplying, installation, testing & commissioning of submersible pumps for suitable rating, with non-clog free flow open CI impeller, CI casing, SS-410 shaft , Pumps shall be provided with lifting chain. Pump should be capable on operation on 415 Volts ± 10 % 50 HZ A.C 3 phase supply. The pump shall be CED coated. The above pump sets must be supplied complete with following accessories:- Necessary cables from pump set to control panel - 1 Set Electrical switch panel having all necessary accessories & safety devices of standard specifications. Panel shall be suitable for both pump work at time.(Panels with sump pumps near each sump as per site conditions). -1 No. Automatic built-up water level controller with necessary length of cable upto control panel. 200 mm dia C.I Butterfly valve (PN-1.0) - 2 Nos 200 mm dia C.I. Dual plate check valves (PN-1.0) -2 Nos Each pump Capacity: 125 m3/hr,Head : 12 Metre Each pump KW :15 (Approx.) or as required. Solid handling : 10 to 12 mm Quantity : 2 Nos. (1W+1SB) (Back side display rain Water drainage) Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model LBH 61535
Supplying, installation , testing & commissioning of submersible pumps for suitable rating, with non-clog free flow open CI impeller, CI casing, CI cutter/griner,SS-410 shaft , Pumps shall be provided with lifting chain. Pump should be capable on operation on 415 Volts ± 10 % 50 HZ A.C 3 phase supply. The pump shall be CED coated. The above pump sets must be supplied complete with following accessories:- Necessary cables from pump set to control panel - 1 Set Electrical switch panel having all necessary accessories & safety devices of standard specifications. Panel shall be suitable for both pump work at time. (Panels with sump pumps near each sump as per site conditions). -1 No. Automatic built-up water level controller with necessary length of cable upto control panel. 80 mm dia C.I Butterfly valve (PN-10) - 2 Nos 80 mm dia C.I. Dual plate check valves (PN-10) - 2 Nos Each pump Capacity: 10 m3/hr,Head : 25 Metre Each pump KW : 4 (Approx.) or as required. Solid handling : 10 mm Quantity : 2 Nos. (1W+1SB) (Sewarage Drain) Annex block -1 & Ticket counter area.
Supply, Installation , Testing & commissioning of submersible pumps for suitable rating, with non-clog free flow open CI impeller, CI casing, CI cutter/griner,SS-410 shaft , Pumps shall be provided with lifting chain. Pump should be capable on operation on 415 Volts ± 10 % 50 HZ A.C 3 phase supply. The pump shall be CED coated. The above pump sets must be supplied complete with following accessories:- Necessary cables from pump set to control panel - 1 Set Electrical switch panel having all necessary accessories & safety devices of standard specifications. Panel shall be suitable for both pump work at time. (Panels with sump pumps near each sump as per site conditions). - 1 No. Automatic built-up water level controller with necessary length of cable upto control panel. 80 mm dia C.I Butterfly valve (PN-10) - 2 Nos 80 mm dia C.I. Dual plate check valves (PN-10) - 2 Nos Each pump Capacity: 18 m3/hr,Head : 25 Metre Each Pump KW : 4.0 (Approx.) or as required. Solid handling : 10 mm Quantity : 2 Nos. (1W+1SB) (Sewarage Drain) Annex block - 2.
Supply, installation , testing & commissioning of vertical pressure filter fabricated from high performance M.S plate (Epoxy coating) of minimum 6 mm thick for shell & 8 mm thick for dished ends with top and bottom flanged openings including top and bottom hub and lateral distribution and collection system complete with initial charge of filter media, face piping, valves, accessories, painting. (For AC plant for cooling tower) Multigrade grade sand filter media Flow rate : 300 LPM Filteration velocity : 12 cum/hr/sqm Operating Pressure: 3.0 Kg. Sq.cm. Test Pressure: 5.0 Kg. Sq.cm. Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model PTB MGF 1400
Supply, installation, testing & commissioning of chlorine dosing system consisting of one chemical grade HDPE tank of 200 liters capacity with a positive displacement diaphragm dosing pump having variable flow rate of (0-6 LPH). The motor shall be suitable for operation at 240V/ single phase/50 Hertz Supplying. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers & injection fittings for complete automatic dosing, complete all as specified and directed. Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model V 12
Supply, installation, testing & commissioning of MSRL water softening plant (suitable for 3 Kg/Sqcm working pressure) complete with initial charge with T-42 NA Resin, Diaphragm valve with built in ejector for controlling all operations), regeneration system and MSRL tank, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings and water hardness testing kit & HDPE brine tank,salt mixer with SS 316 grade shaft and agitator and gearboxes allow motors to be coupled directly to gearbox flanges or coupled via an input shaft with a flexible coupling or pulley drive with proper supporting & associated works.Including face piping, valves, such as inlet, outlet, backwash, drain, air vent etc,and one number test cock and pressure gauge etc. Softener shall be suitable for the following duty:(For AC plant for cooling tower) Capacity : 300 LPM Treated water hardness 50 Mg/L Regeneration Period 10 Hrs. Shell thickness : 8 mm. Dished ends : 10 mm Brine tank capacity - 1000 litre Resin : T- 42 NA Pump Model: Any make from list of make (Appendix 'D') shall be approved but equivalent to model PTB SOFT 1400 Note: Raw Water sample shall be got tested for design purposes and got approved from GE before placing order.
Supplying, installation , testing & commissioning of 80 mm dia C.I. Dual plate NRV(non-return valve) of PN-16, SS 316 Grade flap with flanges, Nut, bolts & washers, painting etc, complete all as specified and directed.
Supply & fixing 25 mm dia gun metal fitting for water level indicator gauge with isolation valve at top and bottom, heavy guage transparent polythylene tube of approx. 5 m length with colour indicator float clamped to teak board 100 mm wide x 20 mm with marking in KL, complete all as specified and directed.
Supplying, installation , testing & commissioning of 150 mm dia Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet basket with necessary flange / uionons nuts, bolts and wahsers, complete all as specified and directed.
Supplying, installation , testing & commissioning of dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc, complete all as specified and directed.
Supplying, installation , testing & commissioning of following size of heavy class GI suction & delivery headers of required length conforming to IS:1239 with standard GI Fittings and with end flange connections having inlet & outlet flanged connections including GI supports from wall, floors & ceiling complete as required. Cost should be inclusive of all supports/clamps/brackets, anchor fastner etc, complete all as specified and directed.
100 mm dia
150 mm dia
Supply, installation, testing & commissioning of 100 mm dia motorised butterfly valve with float type sensors suitable for 220 volts with working pressure rating of not less than 16kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, confuits, upto junction box ( upto 6 mt approx) etc. complete.Valve shall be as per IP-67, complete all as specified & directed.
Supply and fixing 560 mm dia cast iron (light duty) water tank circular cover with frame, complete in all as specified & directed.
Supply and fixing M.S. puddle flanges fabricated from 750 mm long pipe pieces madeup of R.C.C. water tanks wall / slab. The entire fitting shall be hot dipped galvanised (Flanges shall confirm to BS10 Table E) of following sizes, complete all as specified and directed.
25 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
100 mm dia (Flanged ends MS plate 6 mm thick; 250 mm x 20 mm plus dia of pipe).
150 mm dia (Flanged ends MS plate 6 mm thick; 250 mm x 250 mm plus dia of pipe).
200 mm dia (Flanged ends MS plate 6 mm thick; 300 mm x 300 mm plus dia of pipe).
m) 1 Nos 63 amps four pole(FP) MPCB as outgoing feeders for 15 KW to Irrigation pump control panel. o) Spare MCB'S of following capacities: 16 amps TPN MCB 2 No.spare 32 amps TPN MCB 1 No.spare 63 amps TPN MCB1 No.spare Notes : a) Cost of Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also included in overall cost quoted. b) All MCCB's /MPCB to be suitable for motor duty and shall be of 25 KA breaking capacity and with thermal adjustable setting.
Supplying, Installation, Testing and Commissioning of following 1100 volts grade PVC insulated sheathed copper armoured control cables including end terminations, complete all as specified and directed.
2 core x 1.5 Sqmm
2 core x 1.0 Sqmm
6 core x 1.5 Sqmm
Supplying and fixing of perforated type GI cable trays with supports, hangers, fastners of the following sizes, complete all as specified and directed.
300mm x 25 mm x 1.6 mm
150mm x 25 mm x 1.6 mm
S&F 6 SWG GI wire as earth continuity conductor buried in ground or drawn in conduit/ pipe of fixed to pole or any other indicated situation for loop earthing as required, complete all as specified and as directed.
S&F 50 x 6 mm GI strip as earth continuity conductor buried in ground or drawn in conduit/ pipe of fixed to pole or any other indicated situation for loop earthing as required, complete all as specified and as directed.
RETAINING WALL FOR DEVELOPMENT
Providing and fixing in position weep holes of 100mm diameter UPVC pipes of (4KSC class), of specified length and of approved make and quality including grouting , making good the surrounding surface, cleaning etc, complete all as specified and as directed.
Upto 300mm long
Above 300mm but upto 600mm long
Supplying, stacking and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in in the technical specifications to specified thickness, compacted to a firm condition including mechanical transportation from the location of storage / stacking / quarry, unloading, levelling, spreading, etc. complete as all specified and shown on drawing and as directed. Note: The rates shall be applicable to net quantities after deduction of prescribed percentage for voids mentioned in the specifications.
Supplying and stacking of hard stone (for stone pitching) 225 mm thick at site, complete all as specified and direcetd.
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc., complete all as specified and as directed.(Payment for Stone to be made separately). Note for item Nos.31.30 & 31.40 : Stacking of hard stone and dry stone pitching items required for "Road, Path and hard standing shall be measuered and paid for under these items.
Providing & fixing G.I. Hexagonal chicken wire mesh of 19 size of aperture (12mm x 20 gauge) confirming to IS : 3150 at the junction of dissimilar surfaces of brick / block masonry wall and RCC column / beams and the like including necessary "U" nails / screws with cleats for fixing, overlapping, necessary scaffolding etc. complete all as per specification and as directed. Note: i) The rate quoted by the contrcator shall include for all heights and all locations. ii) The items required for "Sewage Disposal, Area Drainage/Storm water Drainage, Compound wall , Road/path & hard standing and Water Bodies " shall be measuered and paid for under these items.
Providing & applying to the external surafce of concrete/masonry, (whether plastered or form finished), two coats of premium water based, 100% pure Acrylic Exterior Emulsion Paint of approved brand, shade & conforming to IS : 15489 with silicon additives conforming to IS 15489 standards, with low VOC of under 3% by mass, gloss level 4-5 at 60 degrees, GH sheen levels and applied over one coat of approved exterior acrylic primer including preparing the base surface, attending to broken edges, corners or patches of plastered surface and filling with cement sand grout, cleaning & preparing , watering & curing for the required period, manufacturer's warranty of five years for the entire paint system, necessary scaffolding / staging for all heights, leads & levels etc. complete as per manufacturer's guidelines, technical specifications and as directed. Note : The items required for "Compound wall , Road/path & hard standing will be measuered and paid for under these items.
COMPOUND WALL, FENCING & GATE
Design, supplying, fabricating, assembling and installing M.S. sheet cladding work in required architectural profile comprising of 4mm thick solid M.S. sheets CNC cut to required architectural profile and shape fixed to backing plate of 4 mm thick M.S.perforated sheets with perforations as per approved design, including approved supporting M.S. frame work. All steel surfaces shall be finished in approved polyurethane paint over a coat of anti-corrosive epoxy primer in approved colour with surface preparation by sandblasting to grade SA 2.5, texts and symbols chemically etched & filled with approved colour as instructed, all accessories such as brackets, screws, nuts, bolts etc., approved fixing arrangement to the gate structure, treatment of joints as instructed, necessary scaffolding / staging for all all heights, levels and locations as per approved shop drawings and as directed.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the specifications and as directed. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade, complete all as specified and as directed. Note : Structural steel posts, struts, PCC bed blocks, excavation, backfilling etc. shall be measured and paid under relevant items
Supplying & fixing high tensile bolts with hexagonal nuts, grade 8.8 or 10.9 and conforming to IS : 4000, IS : 1367 of approved make (Unbrako or approved equivalent) and in required diameter, length etc. for connection of structural members including plain / spring washers, complete all as specified and directed.
Supplying & fixing approved foundation bolts and nuts (conforming to IS : 5624 & of product Grade C as given in IS 1367 ( Part 2 ) : 1979 of approved quality, diameter and required length for connection of structural members including plain / spring washers etc., complete all as specified and directed.
M&L for Grouting below base plates of columns, equipments, around the foundation bolts, or locations as specified using approved pre-packed cementetious free flow non-shrink grout of approved brand and quality including preparation of surfaces, finishing the surface neat, cleaning the base by water / compressed air, pre-soaking, shuttering / formwork, mixing, placing, curing etc. complete all as per manufacturer's guidelines, complete all as specified and directed. Note: The rate quoted shall also include for pre-packed dry grout material
Mild steel work in Boundary Wall Grill Work & box frame for elevational louvers (using MS hollow tubular square/rectangular sections of YST-310 Grade conforming to IS 4923)
Mild steel frame work for Gates (using M.S. hollow tubular circular (pipe) sections of YST-240 Grade conforming to IS 1161) including M.S. drop down bolts, rails, guides, gaskets, casings, all hardware and other accessories such as nuts, anchor bolts, stiffeners, hinges, base plates & applying a priming coat of approved steel primer etc. complete
ROAD, PATH AND HARDSTANDING
Providing and constructing Sub-Grade With approved good earth (For black top roads) of required thickness satisfying the needs minimum soaked CBR value-10% with approved material as specified below including preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density) including making good the undulations, etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres including providing good earth & stacking the same at site, complete all as specified and as directed.
Providing, laying, spreading and compacting of Granular Sub Base (GSB) with material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 and conforming to Grading-II of Table 400-2 and following compacted thickness with specified closely graded stone metal and sand mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory roller having minimum 80-100 KN static weight to achieve desired density of 98% of MDD (IS 2720 part-8). The strength of each GSB layer shall be evaluated by conducting CBR (IS 2720 part-16 & 31) or plate load test using 750mm dia. plate, (IS 9214) for obtaining equivalent CBR value @ one test per 3000Sq.m compacted surface area as per the grading, including all material, labour, machinery with all leads & lifts as per Clause 401 of MORTH specification etc, complete all as specified and shown on drawing and directed.
175mm compacted thickness (For black top roads)
250mm compacted thickness (For rear plaza)
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to Wet Mix Macadam (WMM) specification of specified compacted thickness, including premixing the well graded crushed stone aggregate with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve desired density of 98% of MDD including all material, labour, machinery with all leads and lifts etc, complete all as specified, shown on drawing and directed.
75mm compacted thickness (For black top roads)
200mm compacted thickness (For all interlocking, grasscrete paved areas & plaza area)
250mm compacted thickness (For rear plaza)
Providing and applying Bituminous primer coat over granular surface with medium setting bitumen emulsion conforming to IS 8887 and spraying primer at the rate of 0.60 Kg / Sqm using mechanical means etc, complete all as specified, shown on drawing and directed. (For black top roads & rear plaza area)
Providing and applying tack coat on WMM @ 0.4 Kg / Sqm using medium setting bitumen emulsion conforming to IS: 8887, using emulsion pressure distributor including preparing the surface & cleaning with mechanical broom etc, complete all as specified, shown on drawing and directed. (For black top roads & rear plaza area)
Providing, laying, spreading and compacting stone aggregates of specific sizes by mechanical means to minimum total compacted thickness of 75mm to Water Bound Macadam specification Grading- II (Using Screening Crushable type such as Moorum or Gravel)Using Screening Type-B (11.2mm Agg.) including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding materials to fill up the interstices of coarse aggregates, watering and compacting to the required density etc, complete all as specified, shown on drawing and directed. (For black top roads)
Providing and laying in position, Dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc, complete all as specified, shown on drawing and directed.
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour ,T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc., complete all as specified, shown on drawing and directed.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications, complete all as specified, shown on drawing and directed.
60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern. (For all paved areas other than rear plaza)
80mm thick Cement concrete paver block of M-40 grade with approved colour, design & pattern. (For rear plaza)
Providing and laying at or near ground level factory made kerb stone of M-35 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required, complete all as specified, shown on drawing and directed. Note: i) Length of finished kerb edging shall be measured for payment. ii) Precast Cement Concrete kerb stone shall be approved by the GE.
Pre-cast RCC Kerb in M25 grade concrete, 150mm x 400mm deep
Pre-cast RCC Kerb and channel in M25 grade concrete of size 425mm wide base (175 kerb + 250 channel), 150mm high kerb above the base and 150mm thick overall.
Providing, laying & levelling river washed pebbles (white, black or any other approved shade) of 40 to 65mm nominal size complete as per specifications, complete all as specified, shown on drawing and directed.
Providing and laying shot blasted Kota stone slab flooring of minimum 35 mm thickness over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand), complete all as specified and as directed.
Providing and laying 18mm thick machine cut, mirror polished "Jet Black" Granite stone slabs flooring as in footpath, roadside plaza or any other similar location as per approved design, pattern and combination etc with other stone slabs, in linear as well as curvilinear profile, all complete as per the architectural drawings, using minimum 18 mm thick Granite stone slab of approved size, colour & shade laid using approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining an average bed thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, including rubbing, curing, polishing to the desired finish, making cut out for services etc., complete all as specified, shown on drawing and directed.
Providing and laying machine cut mirror pre-polished stone slab, in pieces not less than 2 m length each, with machine cut edges for treads of steps with half rounded nosing, including 6 mm wide grooves, 3 numbers, 25mm apart all complete as per the architectural drawings in required design / pattern / combination, using 30 mm thick Jet Granite stone slab of approved size laid using approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining an average bed thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, including rubbing, curing, polishing to the desired finish, joints to match with the line of floor joints, edge polishing, making cut out for services etc, complete all as specified, shown on drawing and directed.
Providing and laying machine cut mirror pre-polished stone slab, in pieces not less than 2 m length each, with machine cut edges for risers of steps all complete as per the architectural drawings in required design / pattern / combination, using 18 mm thick Jet Black Granite stone slab of approved size laid using approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining an average bed thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, including rubbing, curing, polishing to the desired finish, joints to match with the line of floor joints, edge polishing, making cut out for services etc, complete all as specified, shown on drawing and directed.
Providing and laying approved machine cut, pre-polished stone slab (as specified below) in ledges, copings, sills, over bund walls or any other location (as specified below), upto maximum 300mm width in approved design / pattern / combination as shown in drawings, using 30 mm thick Granite stone slab of approved size, colour & shade, including fixing approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining a backing coat average thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, curing, rubbing, mirror polishing, washing, cleaning, approved fixing arrangements, pre-polishing of all stone edges before fixing, edge nosing / chamfering, making grooves wherever required etc., complete as per drawings and details, and as directed. In approved machine cut pre-polished Granite stone slabs minimum 18mm thick, in dark shade for ledges, copings, sills, over bund walls etc. (Granite stone type : "Jet Black") in extrior landscaping work, complete all as specified, shown on drawing and directed.
Providing and laying 40 mm thick Indian Patent Stone (IPS) flooring using cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) mix with 20 mm nominal size stone aggregate & down, laid monolithic with concrete when the concrete is green, floated & trowelled to achieve smooth finish with a floating coat of neat cement using cement slurry @ 2.75 Kg. per Sqm. of floor area, laying the concreting in panels in 1500mm x 1500mm size using 40 x 3mm aluminium dividing strips, as per manufacturer's guidelines, cleaning the sub base, but excluding the cost of nosing of steps etc., complete all as specified, shown on drawings and as directed.
Providing and laying 25 mm thick machine cut mirror polished approved export quality Green Kota stone slabs for flooring, treads and landings etc. in 550mm x 550mm size, laid in approved design / pattern and in combination with other stones using approved polymer modified tile adhesive (of MYK Laticrete or approved equivalent as per list of make) maintaining an average bed thickness of 8 mm, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, including rubbing, curing, making cutouts for services etc., complete all as specified, shown on drawings and as directed.
Providing and laying 300 mm x 300 mm x 35 mm thick honey comb grasscrete cell panels of approved make, shade & quality with self attached anchoring pegs made of UV stabilised, high impact resistant 100% HDPE plastic, min 100 tons/sqm loading capacity, of approx weight 3kg/sqm of approved make laid at site with soil, sand and cocopeat (25%) mix bed 75mm thick as directed by manufacturer, complete all as specified, shown on drawing and directed.
Providing and installing galvanized mechanical anchors with expansion type wedge sleeve for reliable anchoring, for supporting brackets for pipes, cables, plates etc. complete including drilling holes, accessories, etc. complete as per manufacturer's specifications, detailed drawings and as directed.
12mm diameter bolts upto 300mm length
16mm diameter bolts upto 300mm length
20mm diameter bolts upto 600mm length
WATER BODIES
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the GE.The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm per coat
For horizontal surface one coat @ 1.10 kg per sqm per coat
Providing and fixing machine cut pre-polished Jet Black granite stone slab of 30 mm thickness in exterior landscaping work Cladding / dado in approved design / pattern and in combination with other stones to internal vertical masonry / concrete surfaces wherever required using 30 mm thick Granite stone slab of approved size, colour & shade, including fixing approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining a backing coat average thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, including rubbing, curing, polishing to the desired finish, making cut out for services, providing edge moulding as per approved design with polishing etc. all complete all as per approved shop drawings and as directed by the Engineer-in-Charge.The item shall include for providing and installing SS cramps / pins of approved design & conforming to SS 316 Grade with matching recesses in slabs. The holes drilled shall be grouted with nonshrink grout with matching pigment. The item shall also include for providing necessary staging / scaffolding wherever required for all heights, leads & levels, complete all as specified, shown on drawing and directed.
Providing and laying approved machine cut pre-polished Granite stone slabs minimum 18mm thick, in dark shade for ledges, copings, sills, over bund walls etc. (Granite stone type : "Jet Black") in extrior landscaping work, upto maximum 300mm width in approved design / pattern / combination as shown in drawings, using 30 mm thick Granite stone slab of approved size, colour & shade, including fixing approved polymer modified tile adhesive (of MYK Laticrete / Bal Endura / Weber) maintaining a backing coat average thickness of 8 mm, sealing the stone on the back side & four edges of the stone using approved sealer, top sealer coat applied on top of the flooring post fixing of stone, treating the joints and pointing with approved cementitious grout admixed with pigment of matching shade, curing, rubbing, mirror polishing, washing, cleaning, approved fixing arrangements, pre-polishing of all stone edges before fixing, edge nosing / chamfering, making grooves wherever required etc., complete all as specified, shown on drawing and directed.
Providing and fixing approved square bevelled high quality homogeneous combination of glass mosaic tiles of PX20.23 (20%); PX20.22 (40%); PX20.13(20%); PX20.12(20%) in flooring / cladding, using tiles of size 24 mm x 24 mm, 4 to 5 mm thick, (of Pixel Mosaic India Pvt. Ltd. or approved equivalent), shade, quality in specified combination and conforming to IS 13630 & IS 15622 and having surface scratch Mohr's hardness of 6, with grooves on its back side for better adhesion, paper mounted with 1.14 mm gap in combination as per the approved percentage, colour and texture including fixing on floors / wall surfaces with the help of approved tile adhesive (of MYK Laticrete / Bal Endura / Weber) applied at the rate of 2.5 kg per sqm and grouting the joints with approved epoxy grout mix (of MYK Laticrete / Bal Endura / Weber) of matching shade including cleaning, washing of tiles with diluted hydrochloric acid etc, complete all as specified, shown on drawing and directed.
Supply, Instalation testing and Commissioning of 7.5 hp fountain monosub pumpset in the water body suitable for operation on Three phase 50 hz AC supply with 1620 LPM at 12 mtr head, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 5 hp fountain monoblock pumpset in the water body suitable for operation on Three phase 50 hz AC supply with 22.7 LPS at 8 mtr head, complete all as specified and directed.
Supply, Installation, testing and Commissioning of Monoblock 2 HP submersible Pump with CI Impeller,CI Shaft delivering 3.5LPS @ 14 Mtrs head ,suitable for operation on 220 Volts AC Supply , mounted on base frame( For Filteration), complete all as specified and directed.
Supply, Installation, testing and Commissioning of 1 hp fountain monosub pumpset in the water body suitable for operation on Three phase 50 hz AC supply with 2.2LPS at 10 mtr head, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 40 mm dia water defuser heavy duty nozzles in SS 304 Gr, complete all as specified and directed.
Supplying and fixing of 25 mm Dia Geiser Jet heavy duty nozzles with swivel connector and flow control system with fixing etc, complete all as specified and directed.
Supply & Fixing 25 mm dia Swivel Connector for vertical alignmeent of Cascading jet heavy duty nozzles in Gun Metal chrome plated/ Stainless Steel 304 Gr, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 760 mm Dia FRP pressure High rate Sand Filter, delivering (12.5 meter cube per hour) for filteration of suspended mtrl from water body complete with 50 MM dia input and output six position multiport valve for filter, backwash, rinse, waste, recirculate and close all flow to pool the filter body manufactures in fibre glass with uV .resistance surface provided with oil pressure guage , pressure 2.5 Kg/sqcm, complete all as specified and directed. Note: Silica sand will be measured and paid seperately
Supply, Installation, testing and Commissioning of 450 mm Dia FRP pressure High rate Sand Filter (8cum) for filteration of suspended mtrl from water body complete with 50 MM dia input and output six position multiport valve for filter, backwash, rinse, waste, recirculate and close all flow to pool the filter body manufactures in fibre glass with uV .resistance surface provided with oil pressure guage, pressure 2.5 Kg/sqcm, complete all as specified and directed. Note: Silica sand will be measured and paid seperately
Supply of Silica sand for filter with granulometry between 0.4-0.8 mm, complete all as specified and directed.
Supply, Installation, testing & Coimmissioning of Mechanical on line Chlorine Dosing System including 4kg TCCA 90 / Chlorine tablets, complete all as specified and directed.
Supply only of TCCA 90 / Chlorine tablets, complete all as specified and directed.
Supply, Installation, testing & Coimmissioning of 50 mm dia ABS Floor Inlers complete with solvent fixing etc, complete all as specified and directed.
Supply & fixing of uPVC pipe for branching /distribution with all accessories like elbows, tees, sockets including cutting,threading, complete all as specified and directed.
63 mm OD(outer Dia)
110 mm OD(outer Dia)
160 mm OD(outer Dia)
Supply & fixing of 110 mm dia UPVC Butterfly Valves and accessories, complete all as specified and directed.
Supply & fixing of 90mm dia UPVC Butterfly Valves and accessories, complete all as specified and directed.
Supply & fixing of NRV UPVC Vertical of following sizes and accessories, complete all as specified and directed.
100 mm dia
50 mm dia
Supply & fixing of 50 mm dia uPVC Ball Valves with accessories, complete all as specified and directed.
Supply and fixing of 32 mm dia uPVC Ball Valves with accessories, complete all as specified and directed.
Supply & Fixing of 1.2mm thick 300x300 mm main Drain in SS 304 complete with top openable with countersunk screw with frame firmly grouted in base, complete all as specified and directed.
Supply & fixing of 100 mm dia GI pipe manifold complete with inlet 100 mm dia connections etc , complete all as specified and directed.
Supply & Fixing of SS304 Debris Collection Strainer with SS304 mesh for Suction of pumpwith ss clamps etc, complete all as specified and directed.
Supply and Fixing of PVC insulated PVC double sheathed multistranded copper conductor cables, complete all as specified and directed.
3 Core 6 sqmm Flat cables complete as required.
3 Core 4 sqmm Flat cables complete as required.
3 Core 1.5 sqmm Round Cable complete as required.
2 Core 2.5 sqmm Round Cable complete as required.
Supply & Fixing water proof LED lights WW made out of stretched stainless steel suitable for 304 GR to be fitted with emitter type power LED with all in one optical lens of 85% efficiency step tempered glass 8 mm with protection class of IP-68 as required (6x3 watt,24 Volts) (make Sunglow Green Solutions Pvt. Ltd, Meanwell or The Fountainers or any make from list of make Appendix 'D'), complete all as specified and directed.
Supply & Fixing of Linear Light 8 watt per mtr silicon filled class of IP-68 i/c connection & water proof jointing etc as required, complete all as specified and directed. Note: For Srl Item No 38.80 to 38.90 i) Next higher wattage to be installed if specified wattage is not available with the approved manufacturer. ii) Minimum 2 year warranty certificate to be enclosed before release of payment iii) Any make from the list of make (Appendix 'D') shall be approved but equivalent to model/Cat Part No as described in each item. iv) Driver and luminaire shall be of same manufacturer.
Supplying and making straight through water proof joint I/c ferrules and other jointing material for size upto 6 sq mm copper conductor submersible cable, complete all as specified and directed.
Supply & Fixing SS Stand/housing for LED lights with all accessories including nuts bolts, complete all as specified and directed.
Supply & fixing of Constant Voltage Driver(CVD) for LED lights 24 Volts 14.5amp complete as required. (make Sunglow Green Solutions Pvt. ltd, Meanwell or The Fountainers), complete all as specified and directed.
EXTERNAL ELECTRIFICATION, SUBSTATION EQUIPMENT & DG SET
Supply, Installation, testing and commissioning of following light fixtures with all components and accessories having lamp holders and including cost of control gears/lamps, complete all as specified and directed. Note: For Srl Item No 40.10 to 40.23 i) Next higher wattage to be installed if specified wattage is not available with the approved manufacturer. ii) Minimum 2 year warranty certificate to be enclosed before release of payment iii) Any make from the list of make (Appendix 'D') shall be approved but equivalent to model/Cat Part No as described in each item. iv) Driver and luminaire shall be of same manufacturer.
LED 2 X 75 Watt Bi symenteric, 30000K Lumen out put 2 X 7620 lm integrated control gear CRI>80, IP Rating 65 Make: Unilamp Small SIROCCO or iGUZZINI 448 Quid or Distano Visconti 10 cycleways Area light double side, complete all as specified and directed. (Lighting Legend in drawing -F2)
LED 75 Watt Bi symenteric, 30000K Lumen out put 7620 integrated control gear CRI>80, IP Rating 65 Make: Unilamp Small SIROCCO or iGUZZINI 448 Quid or Distano Visconti 10 cycleways Area light double side, complete all as specified and directed. (Lighting Legend in drawing- F1)
LED 9W high, power medium beam angle 48 Deg. spot light, warm white, IP65, IK 08, input voltage 220 to 240 Volts frequency 50 to 60 hz, complete all as specified and directed. Make: 1) Philips Vaya spot BGP 310 3xLED - HP/WW 220-240V 36 2) Unilamp ground washer,minibuzz ordering code 7164-0-3904-xx 3) L.S.I (Lighting Legend in drawing-B)
LED 25 W medium sonnie gear 30000K, lumen output 2350 lm integrated control gear, CRI>80 IP Rating 65, Make: Unilamp medium sonnic gear, or iGUZZINI 576 ipro, or PUK model no 101014, complete all as specified and directed. (Lighting Legend in drawing- FL)
LED 12 Watt, beam angle 38 Deg 30000K lumen output 1770 lm remote control gear, CRI>85, IP Rating 68, S.S Finish, Make : UNILAMP, or iGUZZINI water app RGB B109 , or Philips LED under water BCP 170, complete all as specified and directed. (Lighting Legend in drawing-UP-1)
LED 1 W, beam angle 19 Dg 30000K, lumen output 120 lm, remote control gear, CRI>85 IP Rating 68, S.S. Fnish Make: Unilamp Atom , or iGUZZINI water app B493 , or Philips LED under water BCP 170, complete all as specified and directed.(Lighting Legend in drawing-UP-2)
LED 2 W, warm white steplight , integrated control gear, CRI>80 Make: Philips Model No. 34151, or Unilamp 1 brick / 1,6000-0-3-935-XX, or Distano Box 1607 BOX, complete all as specified and directed.
Walk over in ground uplighter, 10 watt. LED of Philips India limited, 900 lumen, 3000 deg. K, IK 10, with all the accessories like anti-condensation kit IP-68 connection kit, 2mm slim cover plate S/S cover, ground recess housing , drainage system as per installation manual (comes with the fixture) complete with LED constant current driver 350 mA 1-15 W in IP-67 GFR polymer box, complete all as specified and directed. Make: 1. Unilamp ZETZ- R ROS ordering code - 9004-0-2 2 Philips 3. Thorn (Legend in drawing SL-1)
LED 10W , Bulk head, Colour temperature warm white, 54IP, IK09 , Housing High pressure die cast aluminum, Front Cover Poly carbonate front diffuser Glass, complete all as specified and directed. Make: 1) Philips LED Bulkhead 10W 2) Thorn 3) L.S.I (Legend in drawing W1)
LED flood light fixture, 44W, Beam angle 40 deg, IP66, CRI -80 Ra 3000 deg. K, 79 lumens/W, complete all as specified and directed. Make: 1) Philips 12NC -350000015-Ul/cUL) 2) Unilamp 3) L.S.I (Legend in drawing M1)
LED 9W high, power medium beam angle 36 deg. spot light, warm white, IP65, IK 08, input voltage 220 to 240 Volts frequency 50 to 60 hz, complete all as specified and directed. Make: 1) Philips Vaya spot BGP 310 3xLED - HP/WW 220-240V 36 2) Unilamp ground washer,minibuzz ordering code 7164-0-3904-xx 3) L.S.I (Legend in drawing R1)
30W LED Burst power core, 2700 deg. K CRI 82.6 lumen maintenance 70,000 hrs L70@ 50 deg. C, input voltage 100-277V AC auto switching, pf. 979, Die cast aluminium powder coated finish, tempered glass lens IP66, complete all as specified and directed. Make: 1) Philips ew Burst power core 2) Unilamp 3) L.S.I (Legend in drawing P1)
50W LED, 2700k, 100-277V AC,800 spread, integrated control, flood light, complete all as specified and directed. Make: 1) Philips ew blast power case gen 4 2) Unilamp 3) i.Guzzini (Legend in drawing G1)
Supply, installation, errection, testing and commissioning of Galvanized steel octagonal pole overall length 4.5 metre (sheet thickness 3mm), top dia.(A/F) 70mm and bottom dia. (A/F)130mm with base plate dimensions 200mm x200mm x 12mm thick conforming to IS 2629/IS 2633/ IS4759. The pole shall be in single piece (single hot dip galvanized) and shall be tapered towards the top.The bottom section shall have open able slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall also be suitable arrangement for the purpose of earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts.The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity, complete all as specified and as directed. Note: 1) Cost of earth work and PCC foundation in 1:2:4 shall be measured and paid separately 2) Cost of four no. of foundation bolts each of 16 mm dia and 450mm length is included in overall cost quoted by contractor.
Supply and laying of FRLS PVC 3 x 2.5 sq. mm (for Pole and Boundry Wall light) insulated and overall sheathed copper conductor cable in the existing surface/ recessed steel/ PVC conduit pole, complete all as specified and directed.
Supply and fixing of 16 A DP MCB, mounting DIN rail and connecting links for 2 nos 2 core cable in the junction box / slit window in the existing poles, complete all as specified and directed.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and including excavation and earth work 300x300x300mm any type soil and properly grouting in PCC (1:3:6) type C-1 20mm graded stone aggregate, complete all as specified and directed.
Street Light Feeder Pillar Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated front access 3.15 thick steel enclosed, dust and vermin proof, Feeder Pillars suitable for outdoor installation IP 54 protection with hinged and lockable doors complete with interconnections with copper wire, copper crimping lugs, brass glands, bonding to earth and painting, suitable for use at 415 volts, 3 phase 50 Hertz system. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided. The breaking capacity given under are the Ics values INCOMING 1 nos 100 amp 25 kA FP MCCB with thermal magnetic and short circuit release. BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 150 amps having a maximum current density of 160 amp / sq cms. The neutral busbar is to be of 100% capacity. OUTGOINGS 15 nos 6 to 32 amp 10 kA DP MCB with thermal magnetic releases Note for item no. 40.80 & 40.90 - Drawings for feeder pillar boxes shall be approved by AO before fabrication
M&L of supplying and fixing of thermoplastic box IP-65 of size 167x125 mmx82 mm deep complete with thermoplastic cover and with terminals cable entry max M32 as per catalogue no Hensel K8105, complete all as specified and directed. (to be provided at the bottom of panel of compound wall)
S&F rigid non metalic PVC conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc. complete all as specified and directed
SUB STATION EQUIPMENTS
Design, Manufacture, supply of a Five panel Vacuum circuit breaker indoor totally enclosed sheet steel clad floor mounting, vermin proof, IP-4X fully interlocked Horizontal isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having double isolation features complete with circuits as detailed below. The switchboard shall be complete with necessary PVC insulated aluminium busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11kV 3 phase, 50 cycle, earthed system with a rupturing capacity of 500 MVA at 11 kV,fault level 25 kA for 3 sec or 21 kA for 1 sec consist of following:- (A) FIVE PANEL BOARD I) 2 NO INCOMING PANEL EACH COMPRISING OF i) Air insulated metal clad housing - 1 no ii) Three phase PVC insulated copper busbars 630 amps rating - 1 set iii) Single pole cluster type isolating contacts i.e. plug and switches- 6 nos iv) Triple pole draw out truck mounted 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices and earthing truck - 1 no v) Trip free, motor charged spring release closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical 'OFF' & 'ON' indicator - 1 no vi) 30 Volt DC shunt trip coil - 1 no vii) 230 volt motor wound spring charged mechanism - 1 no viii) Dual Core Cast resin CT of ratio 200:5, one core class 1.0, 15 VA burden for metering and second core class 5P10, 15 VA for protection - 3 nos ix) Three Phase cast resin horizontal draw out line potential transformer ratio 11 KV:110 volts, connected star/star with H.V. and L.V. connections, H.V. fuses and L.V. fuses MCB, isolating plugs for H.V. and L.V. Connection of adequate burden - 1 no x) Strip heater to prevent absorption of moisture- 1 no
II) BUSBAR 630 A TP Cu busbar with current density of 1.6 A per sq.mm, suitable to with stand symmetrical fault level of 350MVA at 11 kV. III) BUS COUPLER (One no) i) Air insulated metal clad housing - 1 no ii) Three phase PVC insulated copper busbars 630 amps rating - 1 set iii) Single pole cluster type isolating contacts; i.e. plug and switches - 6 nos iv) Triple pole drawout truck mounted 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices - 1 no v) Trip free, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator - 1 no vi) Red/Green indicating lamps for close and open position - 1 set vii) White indicating lamps one per phase -1 set viii) Blue indicating lamp for spring charged - 1 no ix) Amber indicating lamps for trip circuit healthy - 1 no x) Clear indicating lamp for auto trip -1 no INTERLOCKING Two incomers & One Bus Couplers shall be interlocked electrically & mechanically so that only two out of three shall be switched on at a time. IV) TWO NOS OUTGOING BREAKERS FOR TRANSFORMER EACH EQUIPPED WITH i) Air insulated metal clad housing - 1 no ii) Three phase PVC insulated copper busbars 630 amps rating - 1 set iii) Single pole cluster type isolating contacts; i.e. plug and switches - 6 nos iv) Triple pole drawout truck mounted 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices -1 no v) Trip free, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator -1 no vi) 30 volts DC shunt trip coil - 1 no vii) 230 volt motor wound spring charge mechanism - 1 no
Note: a) Drawings for HT panels shall be approved by GE before placement of order b) All HT panels shall be suitable for "INTERNAL ARC TEST" of 25 kA for 1 sec c) Pre- dispatch inspection of HT panels shall be carried out at manufacturerer permises by Rep. of Accepting officer within overall cost quoted d) Pre-commissioning test shall be carried out by SEI from HQCEWC within overall cost quoted
Supplying, installation, testing and commissioning of 1600 KVA, 11/0433 KV, 3 Phase, 50 Hz, DYN 11, Indoor ONAN type, copper wound transformer as per IS 1180 part I, level II as latest ammendment with ON load automatic tap changing arrangement on HV side in steps of 2.5% for -10% to +5% , having cable end boxes on HV side suitable for 3x 240 sqmm XLPE cable of 11 KV grade and suitable arrangement for 2500Amp bustrunking on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site Note: a) Make; Schneider/ Crompton/ ABB/ Siemens/ Voltamp b) The Transformers should be suitable for paralled operation c) Drawings for transformers shall be approved by GE before fabrication d) Pre- dispatch inspection of transformers shall be carried out by Rep. of accepting officer within overall cost quoted e) Pre-commissioning test shall be carried out by SEI from HQCEWC within overall cost quoted
MAIN LT PANEL Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, rear access free standing, dust and vermin proof (IP 42 ingress protection) main panel suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. All Switchboards shall have provision for entry of cables from the top or bottom as required All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. GA drawings shall be got approved from AO before fabrication Pre- dispatch inspection shall be carried out by Rep. of accepting officer within overall cost quoted
DG SYNCHRONIZATION PANEL Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. All Switchboards shall have provision for entry of cables from the top or bottom as required All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. GA drawings shall be got approved from GE before fabrication Pre- dispatch inspection shall be carried out by Rep. of accepting officer within overall cost quoted Plastering in C.M 1:5-12 mm thick with including cost and conveyance of all materials required
CAPACITOR PANEL (500 KVAR) Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. Encloser portion of panel housing should be IP 65 class of protection. All Switchboards shall have provision for entry of cables from the top or bottom as required All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. GA drawings shall be got approved from AO before fabrication Pre- dispatch inspection shall be carried out by Rep. of Accepting officer within overall cost quoted
k) 50 kvar heavy duty polystrene filled capacitor with inbuilt protective devices. Capacitors shall be complete with detuned copper wound reactor filters - 3 nos l)100 TP MCCB with Thermomagnetic based releases control unit for protection - 1 No b) 70 amp TP contactor for capacitor switching - 1 no m)On/Off push buttons - 1 no n)Red/Green On/Off indicating lamps - 1 no. o)25 kvar heavy duty polystrene filled capacitor with inbuilt protective devices. Capacitors shall be complete with detuned copper wound reactor filters - 1 no p) 63 TP MCCB with Thermomagnetic based releases control unit for protection - 1 No q) 40 amp TP contactor for capacitor switching- 1 no r)On/Off push buttons - 1 no s) Red/Green On/Off indicating lamps - 1 no. t)15 kvar heavy duty polystrene filled capacitor with inbuilt protective devices. Capacitors shall be complete with detuned copper wound reactor filters - 1 no u) 40 TP MCCB with Thermomagnetic based releases control unit for protection - 1 No b) 25 amp TP contactor for capacitor switching - 1 no v)On/Off push buttons - 1 no w) Red/Green On/Off indicating lamps - 1 no x)10 kvar heavy duty polystrene filled capacitor with inbuilt protective devices. Capacitors shall be complete with detuned copper wound reactor filters - 1 no The Switchboard shall be complete with all interconnections, risers, internal wiring, labels etc. complete as required
Supply, laying, jointing and testing of XLPE cable of following cross sectional area insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with copper stranded conductor 1100 volts grade, laid in trenches, passing through ducts/pipes, fixing along poles, complete all as specified and directed. Note: a) Earth work, sand cushioning, brick protection, hume pipe and cable tray shall be measured and paid separately b) Pre despatch inspection by rep. of Accepting officer shall be carried out within overall cost quoted for each cable size where length exceeds 500 RM. c) Color code for cable shall be finalised by G.E
2 core 2.5 sq mm
4 core 2.5 sq mm
12 core 2.5 sq mm
Supplying installation, testing and commissioning of sandwich bustrunking including vertical and horizontal bends, adopter box, flange end and flexible joint with suitable earthing strips having 50 kA breaking capacity and having IP 54 protection, complete all as specified and directed.
2500A with aluminum busbar
Copper Flexibles for 2500A
Supply of trolley mounted carbon di-oxide 9 kgs capacity fire extinguisher, made of mild steel with brass CO2 valve fitted with braided hose. The extinguisher is internally & externally coated with fire red paint and cylinder bearing no. IS 2678 and the gascartiridge bearing with IS certification mark, complete all as specified and directed.
M & L for Insulating mat 2.5 mm thick for 3.3 kV to 11 kV of 1 mtr width x 2m long, complete all as specified and directed.
M & L and fixing standard shock treatment charts in English & Hindi mounted on wooden frame with glass, complete all as specified and directed.
S&F for Danger notice plate of size 25 x 20 cm, made of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with and including mild steel clamps, bolts and nuts of approved size for LT/HT poles, complete all as specified and directed.
Supplying First Aid Box Complete with first aid mediciane , bandage etc in a woodern box of suitable size, complete all as specified and directed.
M & L and fixing fire buckets each painted red with fire written out complete with sand filling, floor/wall mounting brackets, complete all as specified and directed.
Supplying rubber hand gloves 11000 volt grade, complete all as specified and directed.
M & L and fixing wooden key board of size 90x60cm, with glazed door having locking arrangement, including key hanging arrangement duly numbered for Keys as required, complete all as specified and directed.
Supply, fixing and fabricate of fire bucket stand of 5 nos in one row made with MS angle & hook, complete all as specified and directed.
DG SET
DG SETS Supplying, installing, testing and commissioning of ‘Silent Type’ Diesel Generating set alongwith having Prime Power Rating of 750 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: (a) Diesel Engine: Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. (b) Engine mounted Instrument Panel fi tted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip indication (ix) Engine Hours indication (c) Alternator :Synchronous alternator rated at 750 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(d) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (e) Fuel Tank: Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories all as specified (f) Exhaust System:Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor. (g) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp. Hour capacity sealed maintenance free type) as required as per specifications. (h) Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications.
Supplying, installing, testing and commissioning of ‘Silent Type’ Diesel Generating set alongwith having Prime Power Rating of 625 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: (a) Diesel Engine:Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. (b) Engine mounted Instrument Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip indication (ix) Engine Hours indication (c) Alternator :Synchronous alternator rated at 625 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-H insulation.
(d) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement whichs hall be installed on suitable cement concretef oundation and vibration isolation arrangement as per recommendations of manufacturer. (e) Fuel Tank: Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifi cations. (f) Exhaust System:Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor. (g) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp. Hour capacity sealed maintenance free type) as required as per specifications. (h) Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifi cations.
Notes for S.No. 43.10 to 43.21 a) Cost of PCC foundation as per recommendation of manufacturer is included in overall cost quoted by contractor b) Pre- despatch inspection at manufacturer premises shall be done by rep. of A.O within overall cost quoted by contractor c) Pre commissioning test of DG sets shall be carried out by rep. of A.O within overall cost quoted by contractor d) Cost of all accessories such as residential type silencer is included in overall cost quoted by contractor e) All 5 nos of DG sets shall be suitable for parallel operation f) Proportionate loading of DG sets shall be included in overall cost quoted g) It is the responsibility of the Contractor to carry out all necessary works to achieve the smooth operation of D.G sets synchronization panels, Auto load management, Auto load sharing, AMF and Auto start/stop of all Auxiliaries with fully coordinated and trouble free operation of the D.G sets (up to the Main LT Panel)
Supplying and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50 mm thick wiremesh & aluminum cladding etc., all as specified
Supply, installation, testing and commissioning of SS flexible bellow 250mm dia, complete all as specified and directed.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5Core X 240 sq. mm XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 kV grade, complete all as specified and directed.
Supply and erection of canopy type MS structure made out of 40 mm medium class MS pip (class B), 25 x 25 x 3 mm angle iron from work and 14 SWG GI sheet structure shall be grouted in 1:2:4 CC foundation for hanging 8 nos 9 lit each fire fighting buckets including supply of buckets with two coats of anticorrosive paints etc, complete all as specified and directed.
Supplying and fixing NO SMOKING & DANGER ZONE self luminous signages, of size 300x150mm, complete all as specified and directed.
Supply and fixing of dry chemical fire extinguisher 4 kg made of mild steel with brass valve as per IS 2171 : 1976 mounted on wall hook. The extinguisher is to be coated with fire red paint externally and internally, complete all as specified and directed.
Supplying & Fixing 25 mm x 5 mm Copper strip and including 40 mm size medium class G.I. Pipe from earth test point, complete all as specified and directed.
BMS SYSTEM
CENTRAL CONTROL STATIONS (INDIGENOUS)
Supply, installation, testing and commissioning of Intel Core i3-4150 Processor ( 3MB, 3.50GHz w/HD4400 Graphics) (338-BEED), 8GB Dual Channel DDR3L 1600MHz (4GBx2) (370-AAPE), Intel Integrated Graphics, 128GB Solid Drive (400-ADLX), Windows 7 Professional, English, 64bit, US English (QWERTY) Dell KB212-B QuietKey USB Keyboard Black (580-AAQX), Up to 90% efficient PSU Base 49.5cm (19.5 INCH) Non-touch with Camera, Integrated (321-BBGU), 8x Slimline DVD+/-RW Drive (429-AAMY), OptiPlex 3030 Resource DVD (340-AIQP), Dell USB Optical Mouse MS111 (570-AACR), ENERGY STAR Version 6.0 (387-BBEZ), System Power Cord (Philipine/TH/US) (450-AAOJ), Safety/Environment and Regulatory Guide (English/French/Dutch) (340-AGIK), 1-Watt BIOS (340-ABMZ), Heat Sink for Integrated Graphics (412-AADE), AIO Stand OptiPlex 3030 (575-BBCG), 19" TFT monitor
Supply, installation and commissioning of Ink Jet Colour Printer with all accessories and compatible to the computer system as described in Srl item No 45.10 above.
SOFTWARE
Supplying, Testing and Commissioning of the Graphical Software providing the facility to create / provide the following, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, with minimum of 1 user license configurable password protection for Building Automation System as per Specifications.The BMS platform shall natively support standard communication protocols such as Lontalk® and BACnet™. The software should be Web Based Software Required to remotely monitor the system for 5 concurrent users. The BMS software should have email facility for sending critical alarms, complete all as specified and directed.
Supplying, Testing and Commissioning of the necessary Hardwares/ Softwares for Integrating it with 3rd party Devices on Bacnet/Lonworks/ Modbus, complete all as specified and directed.
CONTROLLERS
Supply, Installation, Testing & Commissioning Network controller - Providing, installing, testing and commissioning of Network Supervisory Controller unit for connecting all controllers to it and transferring data to PC platform.(A) The unit shall comply following codes and standards: UL and CE.(B) The unit shall support OPEN STANDARD protocol BACnet and LONTALK (C) Shall be able to store reports and event logs.(D) WEB ENABLED.The controller shall capable of connecting the future expansion DDCs / Integrators. The Controller shall be able to support both Lontalk & BACnet controllers. It should be able to connect atleast 120 controllers. It should have at least one LON port and it should be capable of connecting at least 20 LON devices. It should have 2 links for connecting BACNET/MSTP controllers & both link should be capable to work as Modbus links. Each link should be able to take at least 60 DDCs in a single loop. It should be capable of storing data at least for 72 hours without any battery in case of power failure. It should be web enabled and should be able to work with any kind of search engine, it should have wi-fi capability to connect with remote devices. It should freely support Android and MAC mobile applications for remotely managing the system through GPRS for wi-fi connectivity without any additional cost. It should have a feature to be used as a gateway/router for 3rd party applications on BACNET. It should be web enabled and should not require any software for controlling/monitoring of hard wired points, complete all as specified and directed.
Supply, Installation, Testing & Commissioning Programmable and Application specific controller - Providing, installing, testing and commissioning of filed mounted controllers of the following configurations and as per below specifications: (A) The programmable controllers processors shall be 32-Bit, 50 MH, LONchip BACnet Compatible.The DDC Controllers should be on BACnet & UL listed. The DDC controller shall be as per the I/O Summary. Main DDC Controller(FOR AHU) should have atleast 19 Input/Output point with atleast 8 Universal Inputs(UI), 6 Analog Outputs/Universal Inputs(AO/UI), 4 Digital outputs(DO) And 1 Pressure Input (PI) AND Main DDC Controller should have atleast 21 Input/Output point with atleast 3 Digital Inputs(DI), 2 Universal Inputs(UI), 2 Analog Outputs(AO), 5 Analog Inputs(AI)-Dedicatedly for temperature Input, 9 Digital outputs(DO) The above controllers shall be housed in a vandal proof, lockable and secure MS cabinets to be supplied along with the Controllers.Maximum 2 AHUs per controller/set of controllers to be connected.
SENSORS & FIELD DEVICES
Supply, installation, testing & commissioning of the following Sensors, complete all as specified and directed.
Immersion type temperature sensors for measuring Chilled water & condenser water supply and return temperature (Range 32-140 deg. F)
Duct type temperature sensors for measuring Return air temperature at the Air Handling Units (Range 45-150 deg. F)
Outside Temp. & Rh Sensor
Differential Pressure switch across the Air Handling Units & Ventilation Fans for indicating the Fan & Filter Status
Duct Static Pressure Transmitter
Level switches for indicating water levels in cooling towers
Float Type Level switches for indicating water levels in Tanks
Voltage Transducer
Current Transducer
Flameproof Level Switch
Current Relay
Ultrasonic Flow Meter
Flameproof Level Transmitter
CABLING & CONDUTING
Supply, Installation, Testing & Commissioning of the following cables, complete all as specified and directed.
Unshielded Signal Cables, 2 Core X 1.0 Sq.mm stranded tinned Cu 0onductor, flexible, PVC sheathed type. Signal Cable from Controllers to Sensors shall be used.
Shielded Communication Cables, 2 Core X 1.0 Sq.mm stranded tinned Cu conductor, flexible, PVC sheathed. Communication Cable from Controllers to Controllers & to Third Party Devices shall be used
Supplying, installing, testing and commissioning of FRLS Heavy Duty Rigid PVC Conduits of following dia, with all accessories, complete all as specified and directed.
25 mm dia
20 mm dia
LIFTS AND ESCALATOR
LIFTS
The lift shall be provided with the following:- a) Fireman switch at ground floor to bring the lift at ground floor in case of fire b) Automatic rescue devise unit during power failure including mannual operation provision battery operated type c) Emergency light (LED), battery operated alarm, and stop button in car with rechargeable arrangement d) One light duty fan in false ceiling e) Aluminium chequered plate (3 mm thick) as flooring f) Non stop button/in dependant operation and over load device with alarm g) Over load warning indicator both audio and visual type h) Front door, operations with a minimum time of 10 seconds and up to maximum time of 30 seconds i) Car size shall be in conformity with IS-3534-1976 and body to be stainless steels of 16 gauge with mirror finish j) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS k)Specification plate and intercom hands free press and speak type l) Wire rope of 13 mm dia of suitable length and human interface sensor device for immediate opening of door m) Other standard fixtures and fittings like sheaves, counter weights with guards, buffers, guides, gears, brakes, control panel, motor, locks, governor, car operational panel, power, control and trailing cables complete including minor civil works.
The lift shall be provided with the following:- a) Fireman switch at ground floor to bring the lift at ground floor in case of fire b) Automatic rescue devise unit during power failure including mannual operation provision battery operated type c) Emergency light (LED), battery operated alarm, and stop button in car with rechargeable arrangement d) One light duty fan in false ceiling e) Aluminium chequered plate (3 mm thick) as flooring f) Non stop button/in dependant operation and over load device with alarm g) Over load warning indicator both audio and visual type h) Front door, operations with a minimum time of 10 seconds and up to maximum time of 30 seconds i) Car size shall be in conformity with IS-3534-1976 and body to be stainless steels of 16 gauge with mirror finish j) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS k) Specification plate and intercom hands free press and speak type l) Wire rope of 13 mm dia of suitable length and human interface sensor device for immediate opening of door m) Other standard fixtures and fittings like sheaves, counter weights with guards, buffers, guides, gears, brakes, control panel, motor, locks, governor, car operational panel, power, control and trailing cables complete including minor civil works.
Notes for item 46.20 to 46.31 1) Pre- dispatch inspection shall be carried out by the rep of Accepting officer within overall cost quoted 2) Pre- commissioning test of lifts shall be carried out by rep. of A.O. within overall cost quoted 3) Drawings for lifts shall be vetted by GE before procurement by contractor 4) Any clearance required from "STATE LIFT INSPECTOR" shall be arranged by contractor within overall cost quoted by contractor 5) After issue completion certificate, contractor shall impart training to MES personal for a period of sixteen weeks on operation & maintenance of lifts. Nothing extra shall be payable on this account.
ESCALATORS
Design, manufacture supply, installation, testing, commissioning, approvals and handing over in satisfactory working condition of upto 6000 persons per hour capacity 0.5 mps nominal speed Escalators with steps of 1000 mm width, inclination of 30 degree to the horizontal, vertical rise and length as given below including all controls, accessories, fittings and safety devices complete as per specifications and drawings as given below:-. General No. of escalators Ground floor to 1st floor - 1 no 1st floor to 2nd floor - 1 no Capacity : To carry upto 6000 persons per hour Vertical rise Ground floor to 1st floor - 4.35 m 1st floor to 2nd floor - 4.35 m Inclination - 35 degree Ground floor to 1st floor - 35 Deg. to horizontal 1st floor to 2nd floor - 35 Deg. to horizontal Speed - 0.5 mps nominal Step width - 1000 mm Step band speed - 0.5 mps Step band radius at upper and lower ends - 1000 mm Horizontal steps at upper and lower ends - 2 step horizontal 1000 mm horizontal run
Drive mechanism Power supply - 415V/240 V, 50 Hz Acceptable fluctuation Voltage - +10% Frequency - +5% to -5% System -Planetary/worm and wheel geared drive system transmission direct through shaft for simultaneous drive of step banned and handrail. Lubrication - Effective continuous automatic (life time) lubrication system with non inflammable bio-degradable lubrication. Motor Motor type- Low slip AC squirrel cage DOL starter induction motor suitable for continuous operation. Controller - Microprocessor based controller located inside truss upper landing. Ingress protection For motor - Minimum IP 55 For Controller - Minimum IP 54 Visual features Balustrade height - 1000 mm throughout Balustrade panel material - Glass Panels Glass cladding shall be provided so that the complete mechanism /moving parts are visible Skirting material - SS hair line finish Handrail colour - Black rubber Handrail profile - SS hairline finish Steps - Silver painted ribbed aluminium Operating and safety devices Starting switch - Key operated Emergency stop button - At top and bottom entries Auto operation - This is to stop after predetermine time when there is no passenger on escalator. To start when somebody steps/approaches escalator
Notes 1) Pre- dispatch inspection shall be carried out by the rep of Accepting officer within overall cost quoted 2) Pre- commissioning test of Escalators shall be carried out by rep. of A.O. within overall cost quoted 3) Drawings for lifts shall be vetted by GE before procurement by contractor 4) Any clearance required from "STATE LIFT/ESCALATOR INSPECTOR" shall be arranged by contractor within overall cost quoted by contractor 5) After issue completion certificate, contractor shall impart training to MES personal for a period of Twelve weeks on operation & maintenance of lifts. Nothing extra shall be payable on this account.
M&L of chemical maintenance free earthing consists of earth electrode size 32 mm dia and 3 meter long made of high tensile low carbon steel circula rods, molecularly bonded copper on the outer suface having copper bonding thickness 250 microns to conforming with requirements of UL467-2007 The bore dia for the electrode shall be 6 inches and quantity of Power fill tirm shall 100 lbs application standard of back fill shall be BS 7430 IEEE -80 Note: Cost of earth work as required is deemed to be included in over all cost quoted by the Contractor. Note: i) Cost of earth work is included in overall rate quoted by the contractor. ii) Resistance value of the earthing system shall be less than 1 ohm and value must be submitted by the contractor before payment is release.
RAIN WATER HARVESTING SYSTEM
Construction of ground water re-charge pit size 6.0 mtr x 2.0 mtr x 2.5 mtr effective depth with following specifications and including supplying, installation & execution of all jobs, complete all as specified, shown on drawings and directed. Peripheral brick masonry in cement mortar 1:4 ( 1cement: 4 coarse sand) with necessary 15 mm thick cement plaster 1:3 neat finish( 1 cement : 3 fine sand). Foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (200mm thick). Three layer of media ,top layer shall be Vary coarse sand/pea gravel with 300 mm thick, Middle layer shall be gravel dry stone aggregate bed ( 5 to 10 mm nominal grade) with 300 mm thick and Bottom layer layer shall be boulder 50 to 150 mm size with 300 mm thick. Harvesting top shall be cover with RCC cover with 2 Nos SRFC heavy duty conforming to IS 12592, 560mm dia circular manhole cover with frame in top slab,10- 12 mm thick cement plaster 1 :3 ( 1 cement : 3 fine sand ) mixed with water proofing compound on top of R.C.C slab, finished smooth. complete as required.2 nos,110 mm OD, uPVC perforated solid pipe laid vertically upto 2 mtr above under ground aquifer,with 200 mm dia bore hole in ground in all kinds of soil as directed by the Engineer-in-charge. Making all inlets & outlets in brick masonry walls including cutting holes& making good the same.Constructing brick masonry sedimentation chamber of 2.0 mtr X 2.0 mtr X 2.5 mtr deep size in brick work of class 75 in cement mortar 1:5 (1 cement & 5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), RCC foundation slab 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, PVC foot rests at 300 mm spacing, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required.
AIR CONDITIONING (HVAC) Notes :- i) Cost of any minor parts requied for successful operation of plant is deemed to be included in overall cost quoted. ii) Complete plant shall be run for a peroid of four months, post issue of provisional completion by GE nothing extra shall be payable on this account. iii) Drawings prepared by contractor for air distribution system (duct, grill, trenches etc.) shall be approved by GE before execution.
AIR CONDITIONING EQUIPMENTS Supplying, installing, testing and commissioning of compressor AHRI Certified SCREW WATER CHILLING UNITS each complete with 300 TR capacity actual under condition screw compressors with VFD, Even Pass water cooled condenser and chiller, insulated chiller, flow switch at chiller and condenser, vibration isolators, integral refrigerant piping and power / control cabling from starter to unit, BMS interface unit grooved couplings for condenser and cooler water in/out connections, complete factory charged of refrigerant and oil, accessories as required and called for, automatic and safety controls mounted in central micro-processor based console panel with LCD Display - Touch Screen Type and all mounted on a steel frame complete as per specifications. Chiller and condenser shall be with Higned Marine Water Boxes. Motor shall be suitable for 415±10% V, 50 cycles, 3 phase AC supply and motor cable terminal box shall be suitable to connect Aluminium Cabling. Refrigerant used shall be Ozone friendly HFC-134a as detailed in specifications.
Chiller Chiller Water IN 56°F Chilled Water OUT 44°F Pressure Drop 5 M of WC Fouling factor 0.0005 ft 2.h.oF / Btu Water Flow 720 USGPM Condenser Condenser Water IN 88°F Condenser Water OUT 98°F Pressure Drop 8 M of WC Fouling factor 0.001 ft2.h.oF / Btu Water Flow 1200 USGPM Maximum Power Consumed (Not greater than 0.7 in IkW/TR) Minimum COP (At AHRI 550 / 590 conditions) : 5.75 Minimum IPLV (AHRI 550/590)- 0.40 Notes:- a) The contractor shall also include cost of foundation as recommonded by manufacturer. b) Next higher capacity of chiller can be supplied within overall cost quoted. c) Predispatch inspection at manufacturer permises shall be carried out by rep. of Accepting officer within overall cost quoted by contractor. d) The Chiller shall be authorized AHRI 550/590 test be tested
Primary Chilled water pumps Water flow rate = 720 USGPM Head = 12 m of WC Motor KW = 22.0
Condenser water pumps Water flow rate = 1200 USGPM Head = 25 m of WC Motor KW = 37.0
Hot water pumps Water flow rate = 500 USGPM Head = 20 m of WC Motor KW = 7.5
Supply, Installation, testing and commissioning of package type 500 kW Electric Hot Water Generator constructed out of MS 10 mm thickness sheet (as per specifications) having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with minimum 75 mm thick fibre glass insulation 48 kg density finished with 0.8mm / 22G Aluminum cladding sheet. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in Six steps complete with manual/auto rotary switches. The hot water generator shall be thyristor controlled, complete all as specified and directed. Hot Water Generator capacity shall be suitable for following duty conditions : a. Water ‘IN’ temperature : 110 deg F. b. Water ‘OUT’ temperature : 120 deg F c. Heater Bank to be provided with Six Note: The rate quoted by the contractor shall also include cost of foundation as recommonded by manufacturer.
45000 CFM , 30mm ESP
35000 CFM, 30 mm ESP
26000 CFM , 30mm ESP
23000 CFM , 30mm ESP
20000 CFM , 30mm ESP
18000 CFM , 30mm ESP
15000 CFM , 30mm ESP
12000 CFM, 30 mm ESP
10000 CFM , 30 mm ESP
Supply, installation, testing and commissioning of HDPE expansion tank of capacity 1500 Liter complete with suitable with FR XLPE/XPE 19mm thick of minimum bulk density 28+_4 Kg/cum covered with vapour barrier and finished with 0.5mm thick Al cladding and applied with pidilite SR 99 and complete with float valve, quick fill and control valve etc, complete all as specified and directed . Notes:- i) Total capacity mentioned above is minimum required for the system. ii) Calculation for same shall be submitted by contractor for approval of GE no financial adjustment shall be done for capacity variation upto plus 10 percent.
Supply, installation, testing and commissioning of three layer HDPE make up tank of capacity 10,000 Ltr. complete with air vent and drain connection & overflow, make up connection with float valve & foundation etc, complete all as specified and directed.
Supply, installing, testing and commissioning of horizontal FAN COIL UNITS 1.5 TR (For BMS) with 5mm ESP, blow thru type, each complete with 4 rows deep Chilled Water Coil, centrifugal fan/s, cleanable fabric filters, insulated main condensate extended SS drain pans to cover the uninsulated pipe and valves complete with set of ball valve, 2 way on/off type pressure independant control valve with digital thermostat and electromotive actuator including internal wiring, as described in specifications, casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in conduit upto thermostat box.All fan coil units shall be suitable for 220±6% volts, 50 cycles, single phase power supply, complete all as specified and directed.
CONDENSOR WATER PIPING Supplying and fixing in position the following size of MS heavy class pipes cut to required lengths and installed with all welded joints, providing and fixing in position the necessary fittings like elbows, tees and reducers, mating flanges & sockets with supporting structure as per specification, pipe upto150 mm dia shall be as per IS1239, Upto 350 mm dia minimum 6.35 mm thickness, 400 mm & above minimum 7.0 mm thickness, complete all as specified and directed.
500 mm dia MS pipes
250 mm dia MS pipes
125 mm dia MS pipes
100 mm dia MS pipes
50 mm dia MS pipes
25 mm dia MS pipes
Supplying and fixing in position the following cast iron butterfly valves (PN10) with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
250 mm dia MS pipes.
125 mm dia MS pipes.
100 mm dia MS pipes.
50 mm dia MS pipes.
Supplying, installation, testing and commissioning in position of 250 mm dia cast iron Manual Balancing Valve (PN10) with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
Supplying, Installation, testing and commissioning of 250 mm dia Motorised butterfly valve (PN10) with counter flanges and accessories with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
Supplying and fixing in position of 25 mm dia brass Ball valves (PN10) with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
Supplying and fixing in position of 250 mm dia cast iron Check valves (PN10) with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
Supplying and fixing in position of 250 mm dia MS/CI ‘Y’ Strainers (PN10) with with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
Supply, installation, testing and commissioning of Rubber type expansion bellows of PN 10 pressure rating to be installed at inlet and outlet of each chiller, pump and cooling tower and expanssion joint with counter flanges, nuts & bolts and gasket to suit pressure rating, complete all as specified and directed.
250 mm dia pipes
200 mm dia pipes
125 mm dia pipes
Supplying, installation, testing and commissioning of Auto air vents for 25 mm dia pipes, complete all as specified and directed.
Supplying and fixing ultrasonic/Turbine type Flow meter suitable for 150 mm dia or above with clampon type and below 150 mm dia inline type as per pipe size to measure the flow in Condenser water, Chilled water and Hot water pipe lines. The flow meter shall be provided with necessary fittings & electronic digital read out, complete all as specified and directed.
Clampon type suitable for 150mm dia or above.
Clampon type suitable for 125mm dia
Supplying and fixing in position SS 304 the industrial dial type pressure gauges with gun metal valves, complete all as specified and directed.
Supplying and fixing in position SS 304 the mercury-in- glass industrial dial type thermometers, complete all as specified and directed.
CHILLED WATER PIPING Supplying and fixing in position the following MS heavy class pipes cut to required lengths and installed with all welded joints, providing and fixing in position the necessary fittings like elbows, tees and reducers, mating flanges & sockets with supporting structure as per specification, pipe upto150 mm dia shall be as per IS1239, Upto 350 mm dia minimum 6.35 mm thickness, 400 mm & above minimum 7.0 mm thickness pipe shall be duly insulated with closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously, all as specified and repairing damage to building etc, complete all as specified and directed.
350 mm dia MS pipes with 32mm thick insulation
300 mm dia MS pipes with 32mm thick insulation
250 mm dia MS pipes with 32mm thick insulation
200 mm dia MS pipes with 32mm thick insulation
150 mm dia MS pipes with 32mm thick insulation
125 mm dia MS pipes with 25mm thick insulation
100 mm dia MS pipes with 25mm thick insulation
80 mm dia MS pipes with 25mm thick insulation
65 mm dia MS pipes with 25mm thick insulation
50 mm dia MS pipes with 25mm thick insulation
For Buried Pipe with Insulation: Supplying and fixing in position MS heavy class pipes 350 mm dia with 75mm thick insulation cut to required lengths and installed with all welded joints, providing and fixing in position the necessary fittings like elbows, tees and reducers, mating flanges & sockets with supporting structure as per specification, pipe upto150 mm dia shall be as per IS1239, Upto 350 mm dia minimum 6.35 mm thickness, 400 mm & above minimum 7.0 mm thickness. Supplying, installing and testing of 25/50/75 mm thick (pre-moulded pipe section over MS heavy class pipes for chilled water flow of T.F. quality expanded polystyrene, 24 Kg / M3) insulation on chilled water piping and fitting like valves, flanges union, etc. as per the approved drawings, complete all as specified and directed.
Supplying and fixing in position the following cast iron butterfly valves (PN10) with insulation as indicated in chilled water piping, complete all as specified and directed.
200 mm dia MS pipes.
125 mm dia MS pipes.
100 mm dia MS pipes.
80 mm dia MS pipes.
65 mm dia MS pipes.
Supplying, installation, testing and commissioning in position the following cast iron Manual Balancing Valve (PN10) with insulation as indicated in chilled/ hot water piping, complete all as specified and directed.
200 mm dia.
125 mm dia.
100 mm dia.
80 mm dia.
65 mm dia.
Supplying, Installation, testing and commissioning of Motorised butterfly valve with insulation as indicated in chilled/ hot water piping of following sizes, complete all as specified and directed.
350 mm dia Valves.
200 mm dia Valves.
125 mm dia Valves.
Supplying and fixing in positionm of 25 mm dia brass Ball valves with (PN10) insulation as indicated in chilled/ hot water piping, complete all as specified and directed.
Supplying and fixing in position the following cast iron Check valves (PN10) with insulation as indicated in chilled/ hot water piping, complete all as specified and directed.
200 mm dia valves
125 mm dia valves
Supplying and fixing in position the following MS/CI ‘Y’ Strainers (PN10) with insulation as indicated in chilled/ hot water piping, complete all as specified and directed.
200 mm dia Y Strainer
125 mm dia Y Strainer
100 mm dia Y Strainer
80 mm dia Y strainers
65 mm dia Y strainers
Supply, installation, testing and commissioning of 2 Way Pressure Independent, Control cum Balancing Valve (PICV)/High Rangeability Control Valve with thermostat of following size for AHUs & FCUs. The actuator shall be capable of accepting 2-10 VDC/ 4-20 mA electric signal and shall provide similar transduced feedback output signal to control system for flow measurement. Contractor shall show actual flow measurement v/s flow indicated by valve for atleast 5% of the valves. Necessary instruments for manual flow measurement shall be included. The minimum close off pressure actuator must be 1.5 times shut off head of pump OR 5 bars whichever is maximum. The actuator shall be electromotive type. The valve and thermostat should have necessary arrangements to operate for cooling as well as heating application, complete all as specified and directed.
100 mm dia pipes.
80 mm dia pipes.
65 mm dia pipes.
Supply, installation, testing and commissioning of digital display type thermostat for return air of various air handling Units. The thermostat shall have provision of setting of space temperature by controlling the airflow of AHU, complete all as specified and directed.
Supplying and fixing in position of GI class ‘B’ pipes with specified insulation of following size cut to required lengths and installed with all screwed joints, and providing and fixing in position the necessary elbows, tees and reducers as per specifications for AHU / FCU drain including insulation with 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously, all as specified and repairing damage to building etc, complete all as specified and directed.
50 mm dia
40 mm dia
32 mm dia
25 mm dia
AIR DISTRIBUTION 'Factory fabricated ducts Supply, fabrication, Installation and testing of factory fabricated sheet metal ducts in accordance with shop drawings and specifications, and shall also conform to the SMACNA (adapted & modified herein) specifications including manufacturer's standard accessories(C&S joint not to be used), complete all as specified and directed.
0-450 mm GSS (26 G)
451-1000 mm GSS (24 G)
1001-1800 mm GSS (22 G)
1801-2100 mm GSS (20 G)
2101 mm & above GSS (18 G)
Site fabricated / Round duct To-suit at site Supply, fabrication, Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces, complete all as specified and directed.
0-450 mm GSS (26 G)
451-1000 mm GSS (24 G)
1001-1800 mm GSS (22 G)
1801-2100 mm GSS (20 G)
2101 mm & above GSS (18 G)
Supply, installation, testing and commissioning of 25mm thick acoustic insulation of duct with 25 mm thick resin bonded fibre glass, of 48 kg/cum density and covered with 28 G Aluminium perforated sheet, complete all as specified and directed.
Supply, installation, testing and commissioning of 13mm thick thermal insulation on Supply/Return duct as shown on drawing with 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously, all as specified and repairing damage to building etc, complete all as specified and directed.
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply and return air Grilles in accordance with shop drawings, complete all as specified and directed.
Powder coated extruded aluminiums grilles with volume control damper.
Powder coated extruded aluminium grilles without volume control damper.
Supply, installation, testing and balancing of Powder coated fresh air aluminium louver, volume control damper and pre filter in accordance with shop drawings, complete all as specified and directed.
Supplying, installation, testing and commissioning of powder coated extruded Aluminium linear grills, complete all as specified and directed.
Supplying, installation, testing and commissioning of Extruded aluminium dampers in supply air collars, complete all as specified and directed.
Supply , Installation & testing of GI volume control damper within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per shop drawings, complete all as specified and directed.
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape ceiling diffusers with removable core, anti smudge ring & with volume control dampers as per shop drawings, complete all as specified and directed.
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape diffusers with removable core, antismudge ring & without volume control damper as per shop drawings , complete all as specified and directed.
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape Jet nozzle diffuser with volume control damper, complete all as specified and directed.
Dia 280mm jet nozzle, 800 CFM, 12 meter throw
Dia 315mm jet nozzle, 1000CFM, 20 meter throw
Dia 380mm jet nozzle, 1250CFM, 25 meter throw
Motorised Fire Damper Supply, installation, testing and commissioning of motorised Fire damper, inter connecting wiring at locations shown in drawings, complete all as specified and directed.
Supply, installation, testing and commissioning of Actuators for motorised damper, complete all as specified and directed.
ELECTRICAL WORKS FOR REFERIGERATION (HVAC) Supply, installation, testing & commissioning of front operated front access cubical type indoor duty floor / wall / recess/ surface mounting, totally enclosed dust and vermin proof (minimum protection IP 54) panels with neoprene gaskets, fabricated from 2 mm thick CRCA sheets with powder coated finish (minimum thickness 50 micron) suitable for 415 volts 3 phase 4 wire 50 Hz system to withstand symmetrical fault level of 50 KA at 415 V including interconnections, bonding to earth etc. and flush doors conforming to relevant IEC/IS (viz. IEC 60439, IS 8623 etc.) standard including the earth leakage protection complete as per specification & drawings as required and as given below. All internal wiring in the panels shall be carried out using high temperature FRLS wires. The Switchboards shall be provided with detachable gland plates for entry of cables from the top/bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars shall be insulated with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports suitably spaced shall be used. Hinged doors with padlocking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.
The panel shall have aluminium busbars with bar type feeder connections, spacers etc. Earthing all components, frame etc. to a common internal earth bar of minimum size 50 x 6 mm GI or equivalent copper / aluminium bar All accessories & supporting structures such as channels, ISMC base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc as required. Each incomer and outgoing feeder shall be provided with multiple LED/neon type status indication lamps suitable for 230 V, AC as approved The makes of components and accessories shall, to the extent practically feasible, be same for panels and boards for uniformity, standardisation and replaceability and shall be applicable to all panels/ boards under the scope of work Switchboard including interconnections, labeling, earthing,associated foundation / masonary work & erection etc. complete as required. All MCCBs shall be current limiting type microprocessor based, rated for requisite specified Service short circuit breaking capacity (Ics suitable for isolation conforming to latest IEC947-2/IS13947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V, insulation voltage (Ui) 690 V and with trip free mechanism, handle indicating ON/OFF/tripped position. The breaking capacity as mentioned shall be Ics values. MCCBs shall be compact, suitably designed to provide protection of motors, cables, busbars to suit rated current, unbalanced power distribution as required and with front adjustable overload and short circuit releases and minimum electrical endurance of the order of 7000-8000 operation cycles (higher shall be preferred) for capacity of 100-250 amps. All the MCCBs shall be provided with potential free contacts for connectivity to BMS System
MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 9/10 kA at 415 V AC, current limiting type lower powerloss appx 40 -70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for moter application duty, with minimum Electrical endurance of the order of 20000 operation cycles. Panel/board design shall be compact and components / accessories of compact sizes be used to economies the room space available. All incomer ACB's shall be provided with minimum 2 NO + 2 NC auxiliary contacts and all MCCBs shall be provided with 2 NO+ 2NC auxiliary contacts, and there should be provision to add min. 6 Auxlary contacts. All 4-pole ACBs shall have fully rated neutral pole Interface with BMS contractor for complete integration of system shall be included. Space provision in all panels shall be made. Various panels/boards as given below: MAIN PANEL INCOMING 2 nos 1600 A, 415V, 50kA, 4P ACB complete with microprocessor based over current, short circuit and earth fault protection :Each ACB complete with 1- set Red/Green ON/OFF indicating lamps 1- set of three phase (red, yellow, blue) indicating lamps Amber healthy trip indicating lamps 3 nos. cast resin current transformers of 1600/5 ratio with 15 VA Burden & Class 5P10 for protection and metering 3 nos. cast resin current transformers of 1600/5 ratio with 15VA burden and Class 1.0 for measurement terminals to receive alum. XLPE armoured cables BUS COUPLER:1 no 1600 amp 415 volt operating voltage, 50 kA, 4 Pole ACB with ON/OFF indicating lamp
Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall Standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. All Switchboards shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables.
AHU STARTER PANEL FOR DISPLAY AREA Panel general description shall be as per item-52.90 above but with the following 1 no 100 Amp 4P Load Break Isolator 1no VFD suitable for 22 kW Motor Shall be be comprise with a) Built in Dual 5% impedence DC link reactor (Harmonic filters) on the Positive & Negetive rails of DC Bus of the VFD with max. 5% THD. b) Built in EMC Filters( Electromagnetic compatibility filter) forVFD for restiction of conducted controller having capacity to simultaneously accet 3 feedback signals from temperature sencors or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs. c) 3 no. PID controllers (Proportional integral deviation controller) to control external devices such as chilled water modulating valve, fresh air damper, etc thus reducing the number of I/O in DDC controller and improving reliability d) Automatic Energy Optimization/Load dependednt flux optimization functionality for maximum energy saving. e) Open protocol system BMS (Building management system) & VFD (Variable frequency drive) Digital Ammeter with CT of 100/5 ratio, Class 1.0 with 3 way OFF Seletor Switch. Digital Volt Meter 0-500V with 3 way OFF Seletor Switch. 1 Set ON/OFF LED indicating lamps Ventilation louvers and exhauts fan. The Starter Panel shall be complete with all interconnections, risers, Busbar (150A), internal wiring, labels etc complete as required
AHU STARTER PANEL FOR FIRST AND SECOND FLOOR LOBBY, INDOOR DISPLAY AREA Panel general description shall be as per item-52.90 above but with the following 1 no 63 Amp 4P Load Break Isolator 1no VFD suitable for 15.0 kW Motor Shall be be comprise with a) Built in Dual 5% impedence DC link reactor (Harmonic filters) on the Positive & Negetive rails of DC Bus of the VFD with max. 5% THD. b) Built in EMC Filters( Electromagnetic compatibility filter) forVFD for restiction of conducted controller having capacity to simultaneously accet 3 feedback signals from temperature sencors or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs. c) 3 no. PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc thus reducing the number of I/O in DDC controller and improving reliability d) Automatic Energy Optimization/Load dependednt flux optimization functionality for maximum energy saving. e) Open protocol system BMS & VFD. Digital Ammeter with suitable rating of CT of Class 1. with 3 way OFF Seletor Switch. Digital Volt Meter with 3 way OFF Seletor Switch. 1 Set ON/OFF LED indicating lamps Ventilation louvers and exhauts fan. The Starter Panel shall be complete with all interconnections, risers, Busbar(100A), internal wiring, labels etc complete as required
AHU STARTER PANEL FOR GROUND, FIRST AND SECOND FLOOR INTERNAL DISPLAY, AUDITORIUM, RESTAURANT, LOBBY, HISTORY AREA Panel general description shall be as per item-52.90 above but with the following 1 no 63 Amp 4P Load Break Isolator 1no VFD suitable for 9.3 kW Motor Shall be be comprise with a) Built in Dual 5% impedence DC link reactor (Harmonic filters) on the Positive & Negetive rails of DC Bus of the VFD with max. 5% THD. b) Built in EMC Filters( Electromagnetic compatibility filter) forVFD for restiction of conducted controller having capacity to simultaneously accet 3 feedback signals from temperature sencors or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs. c) 3 no. PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc thus reducing the number of I/O in DDC controller and improving reliability d) Automatic Energy Optimization/Load dependednt flux optimization functionality for maximum energy saving. e) Open protocol system BMS & VFD. Digital Ammeter with of CT of 63/5 ratio,Class 1.0 with 3 way OFF Seletor Switch. Digital Volt Meter 0-500V with 3 way OFF Seletor Switch. 1 Set ON/OFF LED indicating lamps Ventilation louvers and exhauts fan. The Starter Panel shall be complete with all interconnections, risers, Busbar (100A), internal wiring, labels etc complete as required
AHU STARTER PANEL FOR GROUND FLOOR LOBBY, SOUVENIRS AREA Panel general description shall be as per item-52.90 above but with the following 1 no 40 Amp 4P Load Break Isolator 1no VFD suitable for 5.5 kW Motor Shall be be comprise with a) Built in Dual 5% impedence DC link reactor (Harmonic filters) on the Positive & Negetive rails of DC Bus of the VFD with max. 5% THD. b) Built in EMC Filters( Electromagnetic compatibility filter) forVFD for restiction of conducted controller having capacity to simultaneously accet 3 feedback signals from temperature sencors or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs. c) 3 no PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc thus reducing the number of I/O in DDC controller and improving reliability d) Automatic Energy Optimization/Load dependednt flux optimization functionality for maximum energy saving. e) Open protocol system BMS & VFD. Digital Ammeter with CT of 40/5 ratioClass 1. with 3 way OFF Seletor Switch. Digital Volt Meter 0-500V with 3 way OFF Seletor Switch. 1 Set ON/OFF LED indicating lamps Ventilation louvers and exhauts fan. The Starter Panel shall be complete with all interconnections, risers, Busbar (80A), internal wiring, labels etc complete as required
Supply, laying, jointing and testing of Cable end termination of the following 660/1100 volts XLPE insulated Almunium conductor armoured cables including supplying and fixing of crimping lugs, double compression glands, cable sockets, insulation tape etc, complete all as specified and directed.
3.5 core 300 Sq.mm
4 core 6 Sq. mm
4 core 10 Sq. mm
4 core 16 Sq. mm
4 core 25 Sq. mm
4 core 50 Sq. mm
Supply installation of following size of ladder type MS painted cable tray including factory built Tee, bends, elbows etc., supproting structure with GI angle rod, flat, complete all as specified and directed.
Notes for Srl No 48.0 to 53.15 :- i) Cost of any minor parts requied for successful operation of plant is deemed to be included in overall cost quoted. ii) Complete plant shall be run for a peroid of four months, post issue of provisional completion by GE nothing extra shall be payable on this account. iii) Drawings prepared by contractor for air distribution system (duct, grill, trenches etc.) shall be approved by AO before execution
VENTILATION FANS FOR SMOKE EXHAUST AIR Supply, installation, testing and commissioning of ceiling mounted Tube Axial Flow Fans with adjustable pitch blade, MS / GI long casing ( 2 mm thick upto 800 mm dia fan, 3 mm thick from 900 to 1250 mm dia & 4 mm thick above 1300 mm dia ), cast aluminum alloy impeller complete with TEFC Sq. Cage Induction Motor suitable for 415 Volts ± 10%, 50 HZ ± 3%, three phase A.C. supply with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep ( Inlet & Outlet as required ), bird screen ( Inlet & Outlet as required ) etc., of following capacity. The complete fan along with motor shall be suitable for 250 °C temperature rated for 2 hours. Axial Fan shall be AMCA Certified for Air Sound performance in accordance to AMCA 210 andAMCA 300. Complete certified model appearing on AMCA web site shall be accepted. Complete Fan shall be tested and approved by UL in accordance with “Power Ventilators for Smoke Control Systems” for 250 °C for 2 hours, complete all as specified and directed. Note: Fan to have Gravity Louver on exposed face.
Smoke Exhuats for Museum Area Air Qty. = 25000 CFM Static Pressure = 25 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 7.5 Kw. Fan Dia = Not more than 900 mm Tube Axial Fans as described above.
Smoke Exhuats/Fresh air for Auditorium Area Air Qty. = 10000 CFM Static Pressure = 25 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 3.7 Kw. Fan Dia = Not more than 900 mm Tube Axial Fans as described above.
Smoke Exhuats for Attrium Area Air Qty. = 22000 CFM Static Pressure = 25 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 7.5 Kw. Tube Axial Fans as described above.
DG Exhaust Air Qty. = 48100 CFM Static Pressure = 20 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 15.0 Kw. (EFF-1) Fan Dia = 1400 mm Tube Axial Fans as described above.
Kitchen Exhaust Air Qty. = 9000 CFM Static Pressure = 30 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 2.2 Kw. (EFF-1) Noise level = 77 dbA at 3m distance Fan Dia = 710 mm Tube Axial Fans as described above.
Restoration lab Air Qty. = 16660 CFM Static Pressure = 20 mm Wg Fan Speed = Not exceeding 1450 rpm Motor = 5.5 Kw. (EFF-1) Noise level = 77 dbA at 3m distance Fan Dia = 710 mm Tube Axial Fans as described above.
Supply , Installation , testing & commissioning of Ceiling mounted Inline fans with decorative panel of following capacity and spring loaded back draft dampers and complete with ducting, grill/diffuser with damper, motor, supporting frame, gravity louvers, Single Phase etc. as per drawings, complete all as specified and directed.
2200 CFM, static pressure 20mm
1400 CFM, static pressure 20mm
1200 CFM, static pressure 20mm
500- CFM, static pressure 10 mm
450- CFM, static pressure 10 mm
300- CFM, static pressure 10 mm
Supply, Installation, Testing, Commissioning of factory fabricated Air-washer of 8000 CFM, 50mm static pressure comprising of DIDW GI fan, Backward curved, complete with base frame, casing made out of 16G galvanised sheet powder coated having flanged and bolted panels , wet section & tank shall be made of 2 mm thick GI with FRP coating. The Air-washer shall be complete with fill of depth 200 mm & face velocity across the fill shall be limited to 500 FPM. The complete Air-washer shall be as specified in the tender specifications & Schedule of Equipments The Air-washer shall have an efficiency of 90% & shall be complete with motor, belt drive package, GI B Class interconnecting piping Aluminum viscous filters, float valve, quickfill, overflow and drain connections, spray headers, strainer of fine mesh brass screen etc. & of the following capacities. The airwasher shall be complete with 1No. water circulation pump . The blower motor shall be TEFC sq. cage induction suitable for 415V + 10% 50 Hz. 3 phase electric supply, complete all as specified and directed.
Supply, installation, testing and commissioning of 900 mm long air curtains electrical driven single phase, 220V, 50 Hz each complete with 3 pin sockets, stainless steel body, complete all as specified and directed.
600 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
450 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
380 mm dia 900/1450 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
300 mm dia 900/1450 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
225 mm dia 900/1450 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.
Supply, Installation, Testing and Commissioning of Scrubber 9000 CFM air quantity each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications. Electrostatic section shall be made of 18 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh pre filters, Ionizing-Collecting cell(s) shall be of one-piece construction minimum 13.38” inches deep in direction of airflow. All support framing, end plates and ionizer ground electrodes shall be 0.090 inch thick aluminum. Both repelling and collector plates shall be 0.020 inch thick aluminum, 9.125 inch deep in direction of airflow and rigidly retained in place with tubular spacers and tie rods. Spacing between plates shall be no less than 0.175 inch. Ionizing electrodes shall be heavy duty tungsten wire rigidly supported both vertically and laterally. High voltage support insulators shall be of made of Teflon, including center hole, glazed to enhance dielectric strength and retard tracking. Insulators shall be mounted out of the airstream, to reduce contaminant buildup. All high voltage electrical connections within each tier of cells, shall be between cells and automatically made when cells are installed. Average efficiency of 90% to 95% for single pass base on ASHRAE test method at flow rates of 800 –1500CFM per module. Power supplies shall be 100% solid state CE Listed, Module of capacity above 3000 CFM shall be equipped with Pulse width modulating (PWM)The system should be fitted with interlock switch for safety . The system should allow connection to a fan section to achieve 500 FPM velocity across the air cleaner. All units shoud have Arc Supression & Auto Restart, BMS (Building Management System) interface, Performance Indicator Lights to indicate the status of the air cleaning system. Power Consumption should not be more that 50 watts per ESP cell. Operating Voltage : 220V, 50 Hz Ionizing Voltage : 12.5 to 13 KVDC Collector Cell Voltage : 6 to 6.5 KVDC Power Consumption : Not more than 50W per cell.
AIR DISTRIBUTION Factory fabricated ducts Supply, Fabrication , Installation and testing of factory fabricated sheet metal ducts of following sheet thickness in accordance with the approved shop drawings, specifications and shall also conform to the SMACNA (adapted & modified herein) specifications including manufacturer's standard accessories (C&S joint not to be used), complete all as specified and directed.
0-450 mm GSS (26 G)
451-1000 mm GSS (24 G)
1001-1800 mm GSS (22 G)
1801-2100 mm GSS (20 G)
2101 & above GSS (18 G)
Site fabricated / To-suit ducts. Supply, fabrication, Installation and testing of sheet metal ducts of following sheet thickness in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces, complete all as specified and directed.
0-450 mm GSS (26 G)
451-1000 mm GSS (24 G)
1001-1800 mm GSS (22 G)
1801-2100 mm GSS (20 G)
2101 mm & above GSS (18 G)
Supply, installation, testing and balancing of powder coated Extruded Aluminium supply and return air Grilles in accordance with the drawings, complete all as specified and directed.
Powder coated extruded aluminiums grilles with volume control damper.
Powder coated extruded aluminium grilles without volume control damper.
Supply, installation, testing and balancing of Powder coated fresh air aluminium louver, volume control damper and pre filter in accordance with the drawings, complete all as specified and directed.
Supplying, installation, testing and commissioning of powder coated extruded Aluminium linear grills, complete all as specified and directed.
Supplying, installation, testing and commissioning of Extruded aluminium dampers in supply air collars, complete all as specified and directed.
Supply , Installation & testing of GI volume control damper within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per drawings, complete all as specified and directed.
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape ceiling diffusers with removable core, anti smudge ring & with volume control dampers as per drawings, complete all as specified and directed.
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape diffusers with removable core, antismudge ring & without volume control damper as per specifications, complete all as specified and directed.
Motorised Fire Damper Supply, installation, testing and commissioning of motorised Fire damper, inter connecting wiring at locations shown in drawings and as per specifications, complete all as specified and directed.
Supply, installation, testing and commissioning of Actuators for motorised damper, complete all as specified and directed.
ELECTRICAL WORK FOR VENTILATION
Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall Standing, dust and vermin proof (IP 42 ingress protection) main switchboards indoor type suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. All Switchboards shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. Ventilation Panel for Smoke Venting fan of Museum INCOMING 2 nos 800 A, 415V, 35kA, 4P ACB complete with thermal overload and magnetic short circuit release:Each with 1- set Red/Green ON/OFF indicating lamps 1- set of three phase (red, yellow, blue) indicating lamps Amber healthy trip indicating lamps
3 nos. cast resin current transformers of 800/5 ratio with 15VA burden and Class 1.0 for measurement Terminals to receive aluminium XLPE armoured cables BUS COUPLER : 1 no 800 amp 690 volt 35 kA, 4 Pole ACB with ON/OFF indicating lamp BUSBAR: Electrolytic high conductivity aluminium three phase and neutral bus bars rated at 1200 amps having a maximum current density of 1 amp per sq. mm suitable to with stand symmetrical fault level of 35 KA for 1 second. at 415 volts. The neutral bus bars is to be of 100% capacity. BUS SECTION-I:20 nos MPCB working and 3 nos. MPCB spare with short circuit magnetic releases suitable for motors 7.5 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter BUS SECTION-II: 20 nos MPCB working and 3 nos. MPCB spare with short circuit magnetic releases suitable for motors 7.5 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter. Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system. Two incomers and bus coupler shall have interlocking such that only two can be switched ON at a time.
Ventilation Panel for Smoke Venting fan of Auditorium Panel general description shall be as per item no-55.20 & 55.21 above but with the following 1 nos Motor Protection Circuit Breakers with short circuit magnetic releases suitable for motors 3.7 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter and complete with the following Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system.
Ventilation Panel for Smoke Venting fan of Attrium Panel general description shall be as per item no-55.20 & 55.21 above but with the following 1 nos Motor Protection Circuit Breakers with short circuit magnetic releases suitable for motors 7.5 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system.
Ventilation Panel for Kitchen Exhaust Panel general description shall be as per item no-55.20 & 55.21 above but with the following 1 nos Motor Protection Circuit Breakers with short circuit magnetic releases suitable for motors 3.7 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system.
Ventilation Panel for Restoration lab Panel general description shall be as per item no-55.20 & 55.21 above but with the following 1 nos Motor Protection Circuit Breakers with short circuit magnetic releases suitable for motors 5.5 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter Automatic DOL starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system.
Ventilation Panel for DG Venting fan Panel general description shall be as per item no-55.20 & 55.21 above but with the following 5 nos MCCB with short circuit magnetic releases suitable for motors 15.0 kW motor complete with automatic direct online complete with bimeticalic overload releasee and NO/NC for remote control,single phase preventer and ammeter Automatic Star delta starter contactor with bimetal overload releases and NO/NC for remote operation. Single Phase preventor Ammeter The Switchboard shall be complete with all interconnections, risers, internal wiring, labels, interlocking etc. with fire alarm panel system. Note for Srl item No 55.20 to 55.70 Drawing for all theses panels shall be got approved from AO before placing an order to their manufacturer/panel builder.
Supplying and fixing MS poweder coated sheet steel (as per IS standards) Ladder type cable trays fabricated from sheet steel having suitable runners and rungs, with all factory made MS poweder coated accessories such as horizontal cross, vertical elbow, horizontal elbow, tees, reducers etc. including the cost of providing 2 nos. 25 mm x 6 mm GI earth strips on support arrangement of approved design fabricated from hot dip GI angles/flats/rods including jointing the steel sections of the support arrangement with nuts & bolts as per specifications and as directed.
100 mm wide
150 mm wide
300 mm wide
450 mm wide
600 mm wide
750 mm wide
900 mm wide
1000 mm wide
1200 mm wide
Supply, laying, testing and commisioning of the GI strip of the following sizes for interconnecting the earthing station and panels on cable tray/surface/ground complete with all accessories and as required, complete all specified and directed.
50x6 mm GI strip
25x6 mm GI strip
25x3 mm GI strip
M&L for MS bracket including wooden block and fastener of suitable size for saddling of duct, etc. complete all as specified and as directed.
M&L for wooden block of suitable size for saddling of chiled water pipe etc. complete all as specified and as directed.
Boom Barrier and bi-parting sliding door
Supplying, installing, testing & commissioning, of approved electromechanical intensive usable Boom Barrier constructed out of galvanized steel painted barrier case, aluminum Boom bar, intelligent safety features, LED signaling lights, various operating and safety features, boom bar support, automatic diagnostics during operation, with differentiated visual signals according to the type of fault, operation in power failure by internally fitted, rechargeable batteries, protected manual key release device and advance features integrating the various optional and safety accessories etc. complete all as per approved shop drawings, manufacturer's specifications and as directed by the GE with detailed salient features enumerated as under: i) Barrier : Galvanized steel painted barrier in the form of cuboid shaped unit with advance control features to integrate various operating and safety accessories including provision of limit switches for speed and slowdown during both opening and closing which shall be adjusted both mechanically and electronically. ii) Boom Bar : Rectangular shaped painted aluminum boom bar with signaling lights and pneumatic edge upto 6 m length & with easy balancing by linear adjustment of the spring including boom connectors and aluminium painted boom skirting also available if required. iii) Safety Features : Intelligent safety features on opening and closing (If boom gets obstructed it shall immediately move in upward direction with signaling by the LED lights). iv) Automation System : Automation system with advance features such as : a) Single phase 230 V with minimum opening time of 1.5 to 10 seconds as per boom size with protection grade IP 44 & work cycle ranging from 250 to 600 (cycles/hour),b) Incorporated control unit for signaling that the power supply is correct when started and that the control unit is functioning correctly, c( Automatic diagnostics during operation with differentiated visual signals according to the type of fault d) Control unit to automatically correct any eventual fault / discrepancy, e) Automatic programming and single push button press limit switch setting, f) Protected manual key-operated release for emergency operation and in case of power failure Note: Drawing and design shall be got approved from GE before placing order.
In 3 metres long boom barrier
In 5.50 metres long boom barrier
Designing, supplying, fabricating, assembling, installing, testing and commissioning in required position, top mounted "motorized bi-parting sliding door" of approved make and quality made out of 6mm thick polycarbonate sheets / panels on both sides with high precise double modular main sliding track and heavy duty dual type top rollers and bearings, nylon stoppers provided at middle and end of top sliding track to restrict sliding of door beyond limit, automation system with advance control to integrate range of operating and safety accessories etc. complete all as per approved shop drawings, manufacturer's specifications and as directed by the GE with detailed salient features enumerated as under : i) Panel Profile : Frame shall be made out of super durable polyester powdercoated mild steel tubular sections with provision for fixing polycarbonate sheets of 6mm thickness on both sides Thickness of powder coating shall be minimum 60 microns.ii) Door Panel : Door panels shall be made out of 3mm / 6mm thickness polycarbonate sheets /panels of approved make, shade & qualityiii) Main Sliding Track with roller assembly : High precise double modular main sliding track for full sliding width and dual type double bearing zinc plated top rollers. The track shall be fitted on steel or RCC surface with steel cleats at top.iv) Automation System : Electric motor operated drive unit of approved imported make, power supply 230 VAC Single/ Three Phase 50/60 Hz, inbuilt magnetic limit switch and control panel, protection class IP 44, metal rack bolted to bottom member of gate frame for interlocking with motor gear stimulating rack and pinion mechanism. The width of metal rack shall equal the gate width. In the event of power failure the release device shall make it possible to operate the gate manually. v) Standard Accessories : One 3 way Push button standard with automation system Note: Drawing and design shall be got approved from GE before placing order.
Designing, supplying, fabricating, assembling, and installing in required position, "Motorised Double Wall Rolling Insulated Shutter of 6000 mm x 7200 mm size", vertical rolling type, used for internal and external application comprising of various components such as aluminium slats, bottom profile, side guides, brackets, shaft assembly, GI hood cover and hardwares, imported make automation system, safety and all accessories etc. complete all as per approved shop drawings, manufacturer's specifications and as directed by the Engineer with detailed salient features enumerated as under : Slat Curtain : Aluminium double wall slat profile with insulation, microprofiled slat section continuous in single piece without any joint, end cap provided at both ends for interlocking slats. Bottom Profile : Super durable polyester powder coated aluminum bottom profile with rubber safety edge for dust protection and sealing and interlocked with bottom most slat section by end caps. Powder coating shall be minimum 60 microns thickness and in approved colour. Side Guides : Super durable polyester powder coated aluminum side guide of minimum 3mm thickness & width of 105 mm with rubber edge sealing on both ends for full height of side guide, provision of rollers at the top of side guides for noiseless smooth movement of shutter. Powder coating shall be minimum 60 microns thickness and in approved colour. Bracket Plate : Epoxy coated Mild Steel bracket plates of minimum 3 mm thickness. Wand of required size. The load of slat curtain shall transfer through side brackets provided with bearings for smooth rolling movement. Roller Shaft : Epoxy coated Mild Steel hollow tubular pipes of diameter ranging from 100 mm to 300 mm as required with machined shaft and flange welded at respective ends of tubular pipe. The slat curtain shall be fixed to the roller shaft through supporting slat by nut & bolts.
Hood Cover : GI sheeted hexagonal shaped hood cover of 0.8 mm thickness to cover shaft and bracket assembly. Automation System : Electrically operated motor indirect drive of approved imported make and operating on 220 V / 380 V, 1 phase or 3 phase. The motor shall be mounted parallel to the roller shaft. the emergency operation shall be by chain wheel drive. The motor shall be connected to shaft assembly via sprocket and chain. The motor shall be equipped with inbuilt approved safety & thermostat devices. Control : Inbuilt basic control card with integerated limit switch Standard Accessories : One 3 way standard Push button provided with the automation system
Globalzone Sanitory Infrastructure Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid