EXECUTIVE ENGINEER
E 400KV SUB-STATION GREATER NOIDA, GAUTAM BUDHNAGAR
Strengthening work of 220 kV Noida Sector 20 Ckt-2nd at 400 kV Substation Greater Noida under E400 kV S/S Division Greater Noida
2025_UPTCL_990471_1
T-03/2024-25EE/400KV/GN
Open Tender
Electrical Works
Item Rate
90 days
E 400KV SUB-STATION GREATER NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ELECTRICITY 400 KV S/S DIVISION GREATER NOIDA
₹2,000
25 Jan 2025
5 Jan 2025
17 Jan 2025
5 Jan 2025
17 Jan 2025
5 Jan 2025
Defective 220kV single tarantula conductor jack bus will be dismantled of Y & 13 Phase of 220 kV Noida Sector 20 Ckt 2 and Y phase of 220 kV RC Green Ckt 2 bays (Approx. Length 35 meter of 01 section respectively).
Supply of 220 kV Isolator Clamp suitable for Isolator rod/ plate and twin moose /Tarantulla conductor as per technical specification.
Supply of 220 kV Circuit breaker Clamp suitable for CB plate and twin moose conductor as per technical specification.
Stringing of twin moose conductor Jack bus will be done R phase will be done R phase of 220 kV side of 500MVA ICT S (Approx. Length 35 meter of 01 section respectively).
Supply of 220 kV BPI clamp suitable for BPI plate and twin moose conductor as per technical specification
220kV single tarantulla conductor jack bus will be dismantled of all three phase of 220 kV Noida Sector 20 Ckt 2nd (Approx. Length 35 meter of 01 section).
Stringing of twin moose conductor Jack bus will be done R phase will be done R phase of 220 kV side of 500MVA ICT S (Approx. Length 35 meter of 01 section respectively). replaced in MOM Box by New (if required) of mentioned Isolators. For Overhauling, alignment work & proper lubrication will be done of 220 kV bus & line isolators of various bays. Final testing of isolator for proper operation manually including setting right of aux. contacts in Mom box. Status of mentioned isolators will be checked in Bus bar relay for healthy operation.
Stringing of twin moose conductor Jack bus will be done all three phase will be done 220 kV Noida Sector 20 Ckt 2nd (Approx. Length 35 meter of 01 section respectively).
Opening of damage jumper/dropper (220 kV ) and Jumpering of twin moose conductor will be done of 220 kV Noida Sector 20 Ckt 2nd at 400 kV S/S Greater NoidA.
Opening of damage jumper/dropper (220 kV) and Jumpering of single/twin moose conductor will be done of 220 kV Feeders & Transformers bay at 400 kV S/S Greater Noida.
Shifting of new ACSR Moose Conductor from store to switch yard and dismantled materials from site to store. (distance approx 300Meter).
Defective& damaged NO & NC contact will be replaced by new (if required) of 220kV bus & line isolators of varioud 220 kV line & Transformer Bays. Defective parts will be replaced in MOM Box by New (if required) of mentioned Isolators. For Overhauling, alignment work & proper lubrication will be done of 220 kV bus & line isolators of various bays. Final testing of isolator for proper operation manually including setting right of aux. contacts in Mom box. Status of mentioned isolators will be checked in Bus bar relay for healthy operation.
Dismantling of indoor unit of 03 nos. air conditioner for cleaning, checking and repairing
132 KV S/S Taj (03x5.5)
132 KV S/S Bhimanagri (02x5.5)
Cleaning chechking of indoor of 05 nos. air conditioner
132 KV S/S Taj (03x5.5)
132 KV S/S Bhimnagri (02x5.5)
Repairing of leakage of indoor unit 05 nos. air conditioner
132 KV S/S Taj (03x5.5)
132 KV S/S Bhimnagri (02x5.5)
Cleaning of inside surface of air supply duct of air conditioner system spread in fall ceiling of control room building using high power vaccum air compressor, robotic camera, air hammer, special nozzles and air sweep with all other accessories required for inspection of ducts before and after cleaning
132 KV S/S Taj (03x5.5)
132 KV S/S Bhimnagri (02x5.5)
Repair and reconnecting, overhauling of fan motors of above unit
132 KV S/S Taj (03x5.5)
132 KV S/S Bhimnagri (02x5.5)
Meena Elect & Engg. Works (BID ID -4861466)
Gupta Elect and Engg Works (BID ID -4861436)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .