Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹15.5 L+₹37,633 (2.49%)Rejected-Finance PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹16.8 L+₹1.7 L (11.2%)Rejected-Finance | L3 | Rejected-Finance Being not L1. | |
| 4 | L4₹17.6 L+₹2.5 L (16.6%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance Being not L1. | |
| 5 | L5₹21.6 L+₹6.5 L (43.0%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L5 | Rejected-Finance Being not L1. |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
27 Mar 2023, 6:00 pmClosed
GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
DAY TO DAY MAINTENANCE OF ELECTRICAL FITTINGS AND FIXTURES AT SECTOR 28, 31 AND 47 UNDER GE (AF) MC CHANDIGARH
2023_MES_583370_1
GE (AF) MC /CHD-78/2022-2023
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹48,000
Yes
26 Apr 2023
28 Feb 2023
29 Mar 2023
28 Feb 2023
27 Mar 2023
14 Mar 2023
Amount
To attend elect complaints under sector 47 of any nature pertaining to internal electrification, ceiling Fan/Geyser/exhaust fan/or, fault finding, short circuiting, No light of any nature any where reported by users,bldg light, LT control panel, main distribution board, sub distribution board and connected wiring/control LT cables of size of any type and and any location and locating the fault and rectification of the fault and replacing the burnt out items as per site requirement incl making connection and testing after completion of job complete all as specified and directed by Engr-In-Charge.
To attend elect complaints under sector 28 & 31 of any nature pertaining to internal electrification, ceiling Fan/Geyser/exhaust fan/or, fault finding, short circuiting, No light of any nature any where reported by users,bldg light, LT control panel, main distribution board, sub distribution board and connected wiring/control LT cables of size of any type and and any location and locating the fault and rectification of the fault and replacing the burnt out items as per site requirement incl making connection and testing after completion of job complete all as specified and directed by Engr-In-Charge.
Note for item 1 & 2:- (i) The T&P items and testing lamp shall be provided by the Contractor at his own cost. (ii) Any spare required for rectification/replacement will be paid under ser no 3 to 62 items. (iii) The Contractor or his authorized representative (with mobile phone) shall remain in the complaints cells of GE (AF) MC Chd located in Sec 47 daily for collection of complaint slip from the concerned JE E/M. (iv) Contractor will supply following well experienced and well conversant team against GENERAL NATURE COMPLAINTS at 1000 Hrs to 1700 Hrs & URGENT NATURE COMPLAINTS –24 Hrs. at a time for attending elect complaints all working days including Sunday & all Holidays. (v) The date/time and nature of complaint URGENT or GENERAL shall be indicated on each complaint slip by JE E/M. (vi) Replacement of the items shall be measured and paid seperately under serial item no 3 to 62. (vi) All complaint slip shall be returned by the contractor in the complaints cells of GE (AF) MC Chd located in Sec 47 daily or same day upto 1700 Hrs to the JE E/M or his representative after necessary repair/replacement have been carried out and signature of the user on the complaint slip. It is responsibility of the contractor for rectification of complaint to be satisfied by the users. the contractor's dues. URGENT NATURE OF COMPLAINT: Within 02 Hrs AND GENERAL NATURE COMPLAINTS : Upto 1700Hrs. In Case of failure to rectify the defect in complaints within this time, recovery shall be made from the Contractor`s @ Rs 500/- per Hrs for Each urgent nature complaint & @ Rs200/- per day for each general nature complaints. A pucca bound register shall be maintained for this purpose which shall always be kept in custody of JE E/M indicating date. A recovery of missing complaints slip shall be made at rate of @ Rs10. from the contractor. In case of absent of team Rs. 1000/day per person shall be recovered from contractor's dues.
Supply and fix in replacement of Energy saving 20 watts Retro fit LED tube rod T8 1200 mm long complete all as specified and directed .
Supply and fix in replacement of 04 feet 20 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K ,PF >0.9 complete all as specified and directed .
Supply and fix in replacement of 02 feet10 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K ,PF >0.9 complete all as specified and directed .
Supply and fix in replacement of Indoor decorative aluminium extruded 5 watt T5 LED surface mirror fixture having system efficiecy >80,power factor>0.9,THD,10%,surge protection 2.5KV with diffuser and decorative end caps(6500K) complete all as specified and directed.
Supply and fix in replacement of Recess mounting 36 watt LED of size 2x2 feet slim ceiling light with extruded aluminium housing powder coated, milky diffuser, operating voltage 120V-280V, power factor>0.95, inbuilt Short circuit protection and surge protection, soft and uniform light distribution, system lumen more than 100lm/W,CRI>80, integrated constant current electronic driver with 2 year warranty complete all as specified and directed.
Supply and fix in replacement of LED Bulk head Luminaire made of PDC aluminium hosing with polycarbonate diffuser 7 watt LED and heat sink integrated housing system ,colour temp, 6500K, PF >0.9 complete all as specified and directed .
Supply and fix in replacement of LED ADORE 9 watt B22ww 3 star lamp complete all as specified and directed .
Supply and fix in replacement of PVC casing caping 32x16mm complete with fixing nails complete all as specified and directed
Supply and fix in replacement of PVC insulated copper wire FRLS of size 1.5 Sqmm (nominal area), single core for repair of no light complaint as required at site complete all as specified and directed
Supply and fix in replacement of PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) single core for repair of no light complaint as required at site complete all as specified and directed .
Supply and fix in replacement of PVC insulated copper wire FRLS of size 4.0 Sqmm (nominal area), single core for repair of no light complaint as required at site complete all as specified and directed .
Supply and fix in replacement of PVC insulated copper wire FRLS of size 6 Sqmm (nominal area) single core for repair of no light complaint as required at site complete all as specified and directed .
Supply and fix in replacement of of modular metal flush box 3 module complete all as specified and directed.
Supply and fix in replacement of of modular metal flush box 4 module complete all as specified and directed.
Supply and fix in replacement of of modular metal flush box 6 module complete all as specified and directed.
Supply and fix in replacement of modular cover plates suitable for modular switch sockets complete for 2 module the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of modular cover plates suitable for modular switch sockets complete for 3 module the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of modular cover plates suitable for modular switch sockets complete for 4/5 module the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of modular cover plates suitable for modular switch sockets complete for 6/8 module the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
S&F in replacement of 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm square type including sufficient no. of machined screw required at site complete all as specifed and directed..
S&F in replacement of 3 mm thick plastic laminated sheet cover of size 175 x 100 mm rectangular including sufficient no. of machined screw required at site complete all as specifed and directed..
S&F in replacement of 3 mm thick plastic laminated sheet cover of size 200 x 250 mm rectangular including sufficient no. of machined screw required at site complete all as specifed and directed.
Supply and fix in replacement of modular switch one way 6 Amp. And one module, the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of modular switch two way 6 Amp. And one module,the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of modular switch one way 16 Amp. And one module, the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of Modular bell push 6Amp, sinle one way , one module, the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of Modular socket 6 Amp 2/3 Pin combined the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of Modular socket 6A/16A 2/3 pin combined 2 module multipurpose the same as required at site as per original make/size complete with fixing screws complete all as specified and directed ..
Supply and fix in replacement of modular type fan regulator 5 step high speed 100 / 120 W, 230 V, the same as required at site as per original make/size complete with fixing screws complete all as specified and directed .
Supply and fix in replacement of switch piano flush type 5 Amps single pole one-way, complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 15 Amp single pole one way, complete all as specified and directed.
Supply and fix in replacement of Bell push switch piano flush type, 5 Amps complete all as specified and directed.
Supply and fix in replacement of socket outlet flush type 2-in-1, 3 pins 5 Amps multipurpose complete all as specified and directed.
Supply and fix in replacement of socket outlet flush type 2-in-1,3 and 5 pins 15 Amps multipurpose complete all as specified and directed.
Supply and fix in replacement of fan switch/socket type Regulator electronic stepped type 300 watt 240 volts including dismantling of old unserviceable regulator complete all as specified and directed.
Supply and fix in replacement of electric Bell Ding Dong single phase 230 volt complete all as specified and directed .
Supply and fix in replacement of lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
Supply and fix in replacement of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity SP 6 To 32 AMP in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fix in replacement of isolator 2 pole 40 Amps complete all as specified and directed.
Supply and fix in replacement of isolator 2 pole 63 Amps complete all as specified and directed.
Supply and fix in replacement of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity SPN 40 to 63 AMP in the MCB DB complete with connection testing and commissioning complete all as specified and directed..
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity TPN/FP 40 to 100 AMP in the DB complete withnconnection testing and commissioning.
GEYSER
Supply and fix in replacement of Heating element 2000 Watt triangular/ Round type, complete all as specified and directed
Supply and fix in replacement of Thermostate for 25 / 50 Ltrs capacity geyser and making connection complete, complete all as specified and directed
Supply and fix in replacement of indicator lamp any size / type 230 Volts.for geyser complete all as specified and directed
Supply and fix in replacement of PVC connection 600 mm long with PTMT symet nut on both ends suitable to carry water at 60 temp, complete all as specified and directed .
Supply and fix in replacement of safety valve ISI Marked for any cap geysers complete all as specified and directed
Supply and fix in replacement of non - return valve 15 mm dia horizontal / verticle type ISI Marked,for any cap geysers complete all as specified and directed
Supply and fix in replacement of sheet metal including single pole and neutal with 02 Pin and earth plug and socket complete with 01 single pole 20 Amps 240volts, MCB complete incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed
Supply and fix in replacement of 3 core flexible cable of size 1.5 Sqmm with FR PVC round sheathed multi copper conductor complete all as specified and directed
Supply and fix in replacement of MS stove enamelled fastner 100 mm long complete with nut, washer & Split pin complete all as specified and directed
CEILING FAN AND EXHAUST FAN
Supply and fix in replacement of capacitor suitable for 230 volt single phase for ceiling fan 2.5 mfd. complete all as specified and directed
Supply and fix in replacement of capacitor suitable for 230 volt single phase for exhaust fan 3.15 mfd. complete all as specified and directed
Supply and fix in replacement of self adhesive PVC insulation tape 1.8 cmx25mtr x0.125mm size complete all as specified and directed ,
Supply and fix in replacement of ball bearing of Ceiling fan any sweep suitable size complete all as specified and directed .
Supply and fix in replacement of top or bottom ceiling fan canopy any make/size as as required at site complete all as specified and directed .
Supply and fix in replacement of heavy duty shackle type rubber reel complete with clamps. nut, bolt with split pin and washers complete all as specified and directed .
Supply and fix in replacement of 6 Sqmm twin core weather proof aluminium conductor cable complete all as specified and directed
Note:- Amount of credit of Rs. 29910.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S ASHWANI KUMAR & CO.
Sharma Electrical and Engineering Works
GS Engineers
Electromech Engineers
MAGOTRA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .