NIT 1166 PMGSY Road Renewal Maintenance PKG No CG 16-M-51 District- Surguja
196210
NIT 1166 PMGSY Road Renewal Maintenance PKG No CG 16-M-51 District- Surguja
RESTRICTED TENDER
WORKS
PERCENTAGE
6 days
CHIEF ENGINEER ( TENDER CELL)
Required Past Technical Experience: As per Tender document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Panchayat and Rural Development (PARD)
WORKS
MS PRIYANKA SHARMA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CHIEF ENGINEER ( TENDER CELL)
TENDER CELL
CGRRDA RAIPUR
90
06
No
1
196210
11 Aug, 2026 5:30:00 PM IST
14 Aug, 2026 6:05:46 PM IST
27 Jul, 2026 5:30:00 PM IST
NIT 1166 PMGSY Road Renewal Maintenance PKG No CG 16-M-51 District- Surguja
NIT 1166 PMGSY Road Renewal Maintenance PKG No CG 16-M-51 District- Surguja
959000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
47951000.00
2
14 Aug, 2026 5:30:33 PM IST
47951000
AS PER NIT
AS PER NIT
As per Tender document
5000.00 INR
14d 23h 52m
15 documents required · 14 mandatory · 1 optional
₹5,000
₹9.6 L
27 Jul 2026
27 Jul 2026
14 Aug 2026
27 Jul 2026
14 Aug 2026
Providing & Fixing of PMGSY 'Logo' boardProviding and fixing of typical PMGSY logo board as per MoRD specifications and drawings.
Kilometer Stone Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (II) Ordinary Kilometer Stone (Precast)
Kilometer Stone Reinforced cement concrete M15 grade kilometer stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (III) 200 m stone (precast)
Providing and Fixing Informatory and Logo Board of PMGSY Project (B) Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Cautionary, mandatory, informatory direction and place identification sign boards. A Semi-Reflective Traffic signs upto 0.90 sqm Direction and place identification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Guard stones Providing and fixing guard stones on curves or at any other place as directed by engineer incharge made of 220 X220X1000 mm hammer dressed stones / RCC M-15 and fixed 400mm into the ground in morum and broken agreegates block of size 500X500X500mm and painted with white and black bands in 2 coat with redimix enamel paint including excavation of pit etc. complete.
Cutting of branches of trees shrubs and trimming of grass and weeds
Restoration of Rain Cuts. Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and technical specifications Clause 1902
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.(B) Cement Concrete
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.(C) Up to 600 mm dia
Excavation for Structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 (I)Nominal Mix 1:3:6(with 40mm Graded meta
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II. P.C.C grade M 15(Nominal mix (1:2.5:5)
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawin
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and lying reinforced cement concret pipe NP3 for culverts on first class bedding of granular material in single row including fixing coller with cement morter 1:2 but including excavation works backfilling concrete and masonary
field crossing 600 mm dia
field crossing 300 mm dia
Maintenance of hume pipe cluverts by way of clearing erosion repair, repairs to cracks parapet wall and protection work as per drawing and Technical Specification Clause 1908
Maintenance of Slab cluverts by way of clearing erosion repair, repairs to cracks parapet wall and protection work as per drawing and Technical Specification Clause 1909
White washing of parapet walls of CD work and tree trunks , white washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause1915
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307
Construction of embankment with approved material obtained from borrow pits, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 (Beyond 250m)with all leads as per Technical Specification Clause 301.5(Having CBR more than 5)
Scarifying Existing Granular bituminous Surface to a Depth of 100 mm Scarifying existing granular/bituminous surface upto a depth of 100 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) Construction of granular sub-base by providing well graded material having CBR 20 or more, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100KN static weight to achieve the desired density, complete as per Technical Specification Clause 401. For Grading mentioned in table 400.1 (Grading III)
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.For Item No.3.12(a) & (b)
Excavation for Structure as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom a
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 (I)Nominal Mix 1:3:6(with 40mm Graded metal
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, (I).P.C.C. grade M 10, (i) Nominal mix (1:3:6)
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (II) P.C.C grade M 15 (Nominal mix (1:2.5:5)
Filling annular space around footing in rock as per technical specification Clause 1203.4.3.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204,For height upto 5 m, (I) P.C.C grade M 15 (Nominal mix (1:2.5:5)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, (II) R.C.C M 25 (Design mix)
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2
Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawin
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8, (II) Sandy material
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Maintenance of WBM road including filling up of pot holes, ruts and rectifying corrugated surface, damaged edges and raveling as per technical specification Clause 1906..
Prime Coat Providing and applying primer coat with bitumen emulsion(SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Macadam Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504 ii. Bitumen (CG-30)
Pre-mix carpet using bituminous (penetration grade modified bitumen) binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of aggregate 13.2mm size (passing 22.4mm size sieve & retained on 11.2mm sieve and 11.2mm size (passing 13.2mm sieve and retained on 5.6mm sieve) either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. ii. Bitumen (CG-30)
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510, Viscocity grade (VG) Bitumen specification as per IS 73:2006Case - II : Type B (II) Bitumen (VG-30)
Road marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.)
For Routine maintenance
Asst. Engineer CGRRDA, PIU-1, Ambikapur
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.11 MB
1588435723018103103_159177_1278507194557121433_80616_Guidelines to Bidders.pdf
NIT • 0.13 MB
7262198408766140541_196210_NIT 1166 Tender Document Renewal Maintenance Final.pdf
NIT • 1.73 MB
3293172819892633014_196210_BOQ CG 16 M 51.xlsx
BOQ • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].