Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹67.5 L
EMD Value
₹67,500
Closing Date
3 Feb 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Business Plan 24-25 (Part-2) Scheme Work of setting up LT Telnas units for the protection of medium capacity distribution transformers in areas fed by 33/11 KV power substations.
2025_PVVNL_998834_1
T-55/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹67,500
5 Feb 2025
28 Jan 2025
3 Feb 2025
28 Jan 2025
3 Feb 2025
28 Jan 2025
Amount
fctusl Iyku 24&25 ¼ikVZ&2½ ;kstuk ds vUrxZr fo|qr uxjh; forj.k [k.M&cqyUn”kgj ds dk;Z{ks= esa fofHkUu 33@11 dsoh fo|qr midsUnzksa ls iksf’kr {ks=ksa esa e/;e {kerk ds forj.k ifjorZdksa ds izksVsD”ku gsrq ,y0Vh0 VsyuSl ;wfuV LFkkfir djus dk dk;ZA
Providing, fabricating carrying & fixing of Henley type Tailless Fuse Unit hook type arrangement single circuit having 3 Phase + Neutral arrangement ( 1 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 300AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with heavy duty Aluminium lugs suitable for 300 Amp load on at least 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle frame support on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 100 kva T/f and Line side complete. All material except T/F LT PVC cable be provided by the contractor.
Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 500AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 500 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 250 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.
Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 600AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 600 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 400 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.
Providing, fabricating carrying & fixing of Henley type Tailless triple circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 3 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 800AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 800 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 630/1000 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.
NEHA ENTERPRISES (BID ID -4903642)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .