Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
11 Oct 2023, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Public Works Department
EXECUTIVE ENGINEER
Shifting existing 11KV line & Providing & Erection of new lines, Transformers & Accessories form new bypass road to Vinayak Nagar cross & hospet to Ballari, Main Road & Ambedkar circle to Kuduthini Substation 110kv Muss (Kampli Road) & also providing additional Phase line to shifting existing adjacent wards of main road and 11Kv line of F-4 Kudutini Town and F-1. IPset,LINE & F-2 Njy,F-3 Pamoil Factory feeders due to road widening works at KUDUTHINI existing,110KV Kudithini MUSS Due to Road widening works through Subdivision Bly, at Kuduthini Patana panchaythi Kuduthini village in O&M Kudithini section of RSD GESCOM Bellary under 8443-DMF (Deposit Contribution) Action plan-VI for the year 2020-21 to 2022-23.
PWD/2023-24/EL/WORK_INDENT4258/CALL-2
PWD/2023-24/EL/WORK_INDENT4258/CALL-2
Open
Electrical
Two Tender Document System(Two Cover)
PWD Division Office Ballari
4 documents required · 0 mandatory · 4 optional
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 22018-19, 2019-20, 2020-21, 2021-22 and 2022-23 - achieved in at least two financial years an annual financial turnover (in all classes of civil engineering construction works only) of Rs.301.00 Lakhs.
To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2018-19, 2019-20, 2020-21, 2021-22 and 2022-23 - satisfactorily completed as prime contractor, at least one similar work such as - SHIFTING / ERECTION OF NEW HT ELECTRICAL LINES, TRANSFORMERS & ACCESSORIES WORKS not less than Rs.75.50 Lakhs.
Total value of civl engineering works executed and payments received in the last five years (year-wise)
Liquid Assets and /or availability of credit facilities of not less than Rs.75.50 Lakhs (Credit Lines/letter of credit/ certificates from the banks for meeting the fund requirement etc.,)
Copy of Registration for having registered in KPWD/GESCOM
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
₹3,760
₹2.3 L
1 Oct 2023
1 Oct 2023
12 Oct 2023
7 Oct 2023
4 Oct 2023
Estimate A PART-A Material Cost
200010-11Mtrs. Long PSC pole of worki
200107-RCC Pole-9.5M Long, 350 kg WL
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911104-9 Mtr RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
301056-LT Distribution Box for 250 KV
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
3214400-250kVA, Aluminium Wdg, BEE 4 S
357510-L.T. Electronic Tri-Vector Met
358071-With CT ratio 400/5 for 250 kV
82193003-AL lead wire- 240sqmm
Estimate A PART-A Labour Cost
Errection of 11 mtr PSC pole with working load of 365kg in a pit of 2 mtrs depth.
Erection of RCC poles 9.5 mtr long 350Kg WL but in a pit of 2.0 mtr depth for 33KV lines
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole 100 to 250 kVA with 9 mtrs. RCC pole
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit/Distribution Box via metering box.
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
Fixing LT Distribution box for 100/ 250 / 500 KVA DTCs (Excluding wiring)
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
c) Erection of 200-250 kVA Transformer on Transformer structure.
LT Electroic Tri-Vector Meter 5A, Class-0.5/1.0 Accuracy
LT Metering Box For Housing ETV Meter with CT
Estimate A PART-B Material Cost
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911104-9 Mtr RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
301107-L.T.Protection kit
301230-L.T.Distribution Box for 100 /
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
321439-100kVA, Aluminium Wdg, BEE 4 S
357510-L.T. Electronic Tri-Vector Met
358066-With CT ratio150/5 for 100 kVA
Estimate A PART-B Labour Cost
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole 100 to 250 kVA with 9 mtrs. RCC pole
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
Fixing of LT Protection Kit
Fixing LT Distribution box for 100/ 250 / 500 KVA DTCs (Excluding wiring)
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
b) Erection of 100 kVA Transformer on Transformer structure.
LT Electroic Tri-Vector Meter 5A, Class-0.5/1.0 Accuracy
LT Metering Box For Housing ETV Meter with CT
Estimate A PART-C Material Cost
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911102-9 M RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
285555-95 Sq.mm (P.G. Clamps Rabbit
301107-L.T.Protection kit
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
321438-63kVA, Aluminum Wdg, BEE 4 Sta
357510-L.T. Electronic Tri-Vector Met
358061-With CT ratio 100/5 for 50/63
358078-SMC Street lighting metering B
900276.125 watts a)Group A.
900279.250,WATTS a)Group.A
284108.Rabbit Conductor
82193001-AL lead wire 95 sq mm
82193001-AL lead wire 96 sq mm
Estimate A PART-C Labour Cost
Fixing Danger Board
G.I. Barbed Wire (12 Ms/1kg)
Erection of pole Upto 63 kVA with 9 Ms. RCC pole
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
Fixing of LT Protection Kit
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
a) Erection of 25-63 kVA Transformer on Transformer structure.
LT Electroic Tri-Vector Meter 5A, Class-0.5/1.0 Accuracy
LT Metering Box For Housing ETV Meter with CT
SMC Street lighting metering B fixing charge
900276.125 watts a)Group A.
900279.250,WATTS a)Group.A
for Rabbit ACSR
for Rabbit ACSR
Estimate B PART-A Material Cost
200010-11Ms. Long PSC pole of worki
200107-RCC Pole-9.5M Long, 350 kg WL
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911104-9 M RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
285565-240Sq.mm (P.G. Clamps Rabbit t
288536-240 Sq.mm Copper terminals (Lo
301056-LT Distribution Box for 250 KV
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
3214400-250kVA, Aluminium Wdg, BEE 4 S
358071-With CT ratio 400/5 for 250 kV
82193003-AL lead wire- 240sqmm
Estimate B PART-A Labour Cost
Errection of 11 mtr PSC pole with working load of 365kg in a pit of 2 mtrs depth.
Erection of RCC poles 9.5 mtr long 350Kg WL but in a pit of 2.0 mtr depth for 33KV lines
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole 100 to 250 kVA with 9 mtrs. RCC pole
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
Fixing LT Distribution box for 100/ 250 / 500 KVA DTCs (Excluding wiring)
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
c) Erection of 200-250 kVA Transformer on Transformer structure.
LT Metering Box For Housing ETV Meter with CT
LT Metering Box For Housing ETV Meter with CT
Estimate B PART-B Material Cost
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911104-9 Mtr RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
285557-120Sq.mm (P.G. Clamps Rabbit
288532-120 Sq.mm Copper terminals (Lo
301107-L.T.Protection kit
301230-L.T.Distribution Box for 100 /
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
321439-100kVA, Aluminium Wdg, BEE 4 S
357510-L.T. Electronic Tri-Vector Met
358066-With CT ratio150/5 for 100 kVA
Estimate B PART-B Labour Cost
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole 100 to 250 kVA with 9 mtrs. RCC pole
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
Fixing of LT Protection Kit
Fixing LT Distribution box for 100/ 250 / 500 KVA DTCs (Excluding wiring)
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
b) Erection of 100 kVA Transformer on Transformer structure.
LT Electroic Tri-Vector Meter 5A, Class-0.5/1.0 Accuracy
LT Metering Box For Housing ETV Meter with CT
Estimate B PART-C Material Cost
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911102-9 M RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
285555-95 Sq.mm (P.G. Clamps Rabbit
301107-L.T.Protection kit
302122-11kV Class, Solid core
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
321438-63kVA, Aluminum Wdg, BEE 4 Sta
321466-63 Kva,Aluminium wdg,star 2(5
284108.Rabbit Conductor
82193001-AL lead wire 95 sq mm
Estimate B PART-C Labour Cost
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole Upto 63 kVA with 9 mtrs. RCC pole
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
Fixing of LT Protection Kit
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
a) Erection of 25-63 kVA Transformer on Transformer structure.
a) Erection of 25-63 kVA Transformer on Transformer structure.
for Rabbit ACSR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bank gurantee format (emd).doc
Others - bank guarantee • 0.39 MB
eproc_formats(new).xls
Others - formats • 0.11 MB
road specific.pdf
Others - specifications • 1.52 MB
environemnt management system - regulatory requirements.doc
Others - ems • 0.21 MB
4258 Bid document KW-4.doc
Others - Bid document • 6.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .