Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹6.2 L
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification of new Labs and Electric renovation of Library cum Conference hall in the Department of Zoology at main Campus
2022_UDJK_160948_1
F(E.Tend)(UCD)/KU/92/21
Open Tender
Electrical Works
Item Rate
45 days
Main Campus
As Per NIT
3 documents required · 3 mandatory
₹300
Registrar University of Kashmir
Exempted
28 Feb 2022
17 Feb 2022
28 Feb 2022
17 Feb 2022
26 Feb 2022
17 Feb 2022
120 days
Amount
Supply , laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 70 sqmm 3 1/2 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 70 sq. mm
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Double pole
Providing and fixing of 12 way Double door distribution Board (PDB/ LDB)
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links. 160 Amp 25KA 4 pole (for Servo IN)
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links . 100 Amp 25KA 4 pole (for UPS IN)
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 - 160 Amp 4 P MCCB
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description for the follwing items
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring (submain panel to PVTPN/DB)
4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects note: all items included like Conduit, wire, MS box, switches etc.
Providing and fixing of Lighting point wiring with 1.5 mm2 PVC insulated copper wire of FRLS through heavy duty PVC conduit pipe with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular switches, plate & MS box of required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, MS junction box, wire, box, switches etc.
Providing and fixing of fan/ light point wiring with 1.5 sq. mm PVC insulated copper wire of FRLS through heavy duty PVC conduit with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular plate & MS boxof required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, Junction box, wire, box, switches etc.
Providing and fixing of UPS power point with 1.5 sq. mm PVC insulated copper wire , through PVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 1 nos. recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 1.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned note: all items included like Conduit, wire, box, switches etc.
Providing, fixing of 2ft x 2 ft 36W LED slim 230V , complete in all respects. With 2kv surge protection. industrial
Providing/fixing of 4 ft LED slim 16 watt 110lm/w 230V Batten type lights(T5), complete in all respects. With 2kv surge protection. Industrial
Providing and fixing of 12”x12” Metalic type exhaust fan complete with all accessories includindg Frame etc .
Providing and fixing of 48 inches Sweep energy efficient ceiling fan of approved sample at site including wiring the down rods of standard length (30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc including Fan Junction MS box as required.
Providing and fixing of Fan dimmer electronic regulator Including MS box and Modular Plate 5Ampere 3 pin type.
Supplying and fixing 2.5 ft fan rods MS as per site requirement
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in heavy duty PVC conduit (conduit included) as required. 1 run of cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supply and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. D-link Single outlet faceplate with RJ-45 jack
Dismantaling of old electric wiring and set righting as per site requirements
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
Supplying and laying of 2 x 10 sq mm FRLS 1.1 KV grade through medium class PVC conduit ( conduit included) as main earth wires
universal marketing co
M/S WANI ELECTRIC AND MECHANICAL ENGINEERS
M/s J. K. Electrical Works
stage.html
html • 0.02 MB
finance_367556.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .